Transmission line(TL)Parameter Identification(PI)method plays an essential role in the transmission system.The existing PI methods usually have two limitations:(1)These methods only model for single TL,and can not con...Transmission line(TL)Parameter Identification(PI)method plays an essential role in the transmission system.The existing PI methods usually have two limitations:(1)These methods only model for single TL,and can not consider the topology connection of multiple branches for simultaneous identification.(2)Transient bad data is ignored by methods,and the random selection of terminal section data may cause the distortion of PI and have serious consequences.Therefore,a multi-task PI model considering multiple TLs’spatial constraints and massive electrical section data is proposed in this paper.The Graph Attention Network module is used to draw a single TL into a node and calculate its influence coefficient in the transmission network.Multi-Task strategy of Hard Parameter Sharing is used to identify the conductance ofmultiple branches simultaneously.Experiments show that themethod has good accuracy and robustness.Due to the consideration of spatial constraints,the method can also obtain more accurate conductance values under different training and testing conditions.展开更多
Transformers are required to demonstrate the ability to withstand short circuit currents.Over currents caused by short circuit can give rise to windings deformation.In this paper,a novel method is proposed to monitor ...Transformers are required to demonstrate the ability to withstand short circuit currents.Over currents caused by short circuit can give rise to windings deformation.In this paper,a novel method is proposed to monitor the state of transformer windings,which is achieved through on-line detecting the leakage inductance of the windings.Specifically,the mathematical model is established for online identifying the leakage inductance of the windings by applying least square algorithm(LSA) to the equivalent circuit equations.The effect of measurement and model inaccuracy on the identification error is analyzed,and the corrected model is also given to decrease these adverse effect on the results.Finally,dynamic test is carried out to verify our method.The test results clearly show that our method is very accurate even under the fluctuation of load or power factor.Therefore,our method can be effectively used to on-line detect the windings deformation.展开更多
Line parameters play an important role in the control and management of distribution systems.Currently,phasor measurement unit(PMU)systems and supervisory control and data acquisition(SCADA)systems coexist in distribu...Line parameters play an important role in the control and management of distribution systems.Currently,phasor measurement unit(PMU)systems and supervisory control and data acquisition(SCADA)systems coexist in distribution systems.Unfortunately,SCADA and PMU measurements usually do not match each other,resulting in inaccurate detection and identification of line parameters based on measurements.To solve this problem,a data-driven method is proposed.SCADA measurements are taken as samples and PMU measurements as the population.A probability parameter identification index(PPII)is derived to detect the whole line parameter based on the probability density function(PDF)parameters of the measurements.For parameter identification,a power-loss PDF with the PMU time stamps and a power-loss chronological PDF are derived via kernel density estimation(KDE)and a conditional PDF.Then,the power-loss samples with the PMU time stamps and chronological correlations are generated by the two PDFs of the power loss via the Metropolis-Hastings(MH)algorithm.Finally,using the power-loss samples and PMU current measurements,the line parameters are identified using the total least squares(TLS)algorithm.Hardware simulations demonstrate the effectiveness of the proposed method for distribution network line parameter detection and identification.展开更多
We present an exercise that intends to establish a relationship between the strength of nebular emission lines and optical stellar features in the spectrum of a galaxy. After accurately subtracting the stellar continu...We present an exercise that intends to establish a relationship between the strength of nebular emission lines and optical stellar features in the spectrum of a galaxy. After accurately subtracting the stellar continuum and the underlying stellar absorption, we made reliable measurements of the emission lines of all the galaxies in the Sloan Digital Sky Survey Data Release 2 (SDSS DR2). More than 4000 star-forming galaxies with high S/N ratio of both the stellar spectrum and the emission lines are selected. These galaxy spectra are fitted with the 10 PCs of Yip et al., after all the emission line regions have been filtered out. We find that the flux of hydrogen Balmer emission lines, Ha and Hβ can be well recovered from the PCs, while the metal lines are not well reproduced. The fluxes of Ha and Hβ measured from the PC-reconstructed spectra and from the observed spectra agree well with an rms scatter of only - 0.1 dex. This result suggests that, with moderate spectral resolution and S/N ratio, the optical stellar spectrum of a galaxy can serve as an indicator of star formation rate.展开更多
Phasor measurement units(PMUs)provide useful data for real-time monitoring of the smart grid.However,there may be time-varying deviation in phase angle differences(PADs)between both ends of the transmission line(TL),w...Phasor measurement units(PMUs)provide useful data for real-time monitoring of the smart grid.However,there may be time-varying deviation in phase angle differences(PADs)between both ends of the transmission line(TL),which may deteriorate application performance based on PMUs.To address that,this paper proposes two robust methods of correcting time-varying PAD deviation with unknown parameters of TL(ParTL).First,the phenomena of time-varying PAD deviation observed from field PMU data are presented.Two general formulations for PAD estimation are then established.To simplify the formulations,estimation of PADs is converted into the optimal problem with a single ParTL as the variable,yielding a linear estimation of PADs.The latter is used by second-order Taylor series expansion to estimate PADs accurately.To reduce the impact of possible abnormal amplitude data in field data,the IGG(Institute of Geodesy&Geophysics,Chinese Academy of Sciences)weighting function is adopted.Results using both simulated and field data verify the effectiveness and robustness of the proposed methods.展开更多
A novel approach to design Internal Model Controller(IMC)is proposed in this paper directly from measuredinput and output plant data,which are assumed to becontaminated by measurement noise.In order to avoidthe compli...A novel approach to design Internal Model Controller(IMC)is proposed in this paper directly from measuredinput and output plant data,which are assumed to becontaminated by measurement noise.In order to avoidthe complicated structure-identification problem inmost cases,two Finite Impulse Response(FIR)modelsare taken to represent the plant model and the internalmodel controller respectively.Taking account of mea-surement noise both in the plant input and its output,anESD based Total Least Squares(TLS)solution is appliedfor the unbiased identification of the plant model and itsinverse model,the latter constitutes the internal modelcontroller according to the principle that the internalmodel controller approximates the inverse dynamics ofthe plant model.Simulations are given for a testifica-tion.展开更多
基金supported by the National Natural Science Foundation of PR China(42075130)the Postgraduate Research and Innovation Project of Jiangsu Province(1534052101133).
文摘Transmission line(TL)Parameter Identification(PI)method plays an essential role in the transmission system.The existing PI methods usually have two limitations:(1)These methods only model for single TL,and can not consider the topology connection of multiple branches for simultaneous identification.(2)Transient bad data is ignored by methods,and the random selection of terminal section data may cause the distortion of PI and have serious consequences.Therefore,a multi-task PI model considering multiple TLs’spatial constraints and massive electrical section data is proposed in this paper.The Graph Attention Network module is used to draw a single TL into a node and calculate its influence coefficient in the transmission network.Multi-Task strategy of Hard Parameter Sharing is used to identify the conductance ofmultiple branches simultaneously.Experiments show that themethod has good accuracy and robustness.Due to the consideration of spatial constraints,the method can also obtain more accurate conductance values under different training and testing conditions.
基金This work was supported in part by National Natural Science Foundation of China(No.50577050).
文摘Transformers are required to demonstrate the ability to withstand short circuit currents.Over currents caused by short circuit can give rise to windings deformation.In this paper,a novel method is proposed to monitor the state of transformer windings,which is achieved through on-line detecting the leakage inductance of the windings.Specifically,the mathematical model is established for online identifying the leakage inductance of the windings by applying least square algorithm(LSA) to the equivalent circuit equations.The effect of measurement and model inaccuracy on the identification error is analyzed,and the corrected model is also given to decrease these adverse effect on the results.Finally,dynamic test is carried out to verify our method.The test results clearly show that our method is very accurate even under the fluctuation of load or power factor.Therefore,our method can be effectively used to on-line detect the windings deformation.
基金supported by the National Key Research and Development Program under Grant 2017YFB0902900 and Grant 2017YFB0902902。
文摘Line parameters play an important role in the control and management of distribution systems.Currently,phasor measurement unit(PMU)systems and supervisory control and data acquisition(SCADA)systems coexist in distribution systems.Unfortunately,SCADA and PMU measurements usually do not match each other,resulting in inaccurate detection and identification of line parameters based on measurements.To solve this problem,a data-driven method is proposed.SCADA measurements are taken as samples and PMU measurements as the population.A probability parameter identification index(PPII)is derived to detect the whole line parameter based on the probability density function(PDF)parameters of the measurements.For parameter identification,a power-loss PDF with the PMU time stamps and a power-loss chronological PDF are derived via kernel density estimation(KDE)and a conditional PDF.Then,the power-loss samples with the PMU time stamps and chronological correlations are generated by the two PDFs of the power loss via the Metropolis-Hastings(MH)algorithm.Finally,using the power-loss samples and PMU current measurements,the line parameters are identified using the total least squares(TLS)algorithm.Hardware simulations demonstrate the effectiveness of the proposed method for distribution network line parameter detection and identification.
基金Supported by the National Natural Science Foundation of China.
文摘We present an exercise that intends to establish a relationship between the strength of nebular emission lines and optical stellar features in the spectrum of a galaxy. After accurately subtracting the stellar continuum and the underlying stellar absorption, we made reliable measurements of the emission lines of all the galaxies in the Sloan Digital Sky Survey Data Release 2 (SDSS DR2). More than 4000 star-forming galaxies with high S/N ratio of both the stellar spectrum and the emission lines are selected. These galaxy spectra are fitted with the 10 PCs of Yip et al., after all the emission line regions have been filtered out. We find that the flux of hydrogen Balmer emission lines, Ha and Hβ can be well recovered from the PCs, while the metal lines are not well reproduced. The fluxes of Ha and Hβ measured from the PC-reconstructed spectra and from the observed spectra agree well with an rms scatter of only - 0.1 dex. This result suggests that, with moderate spectral resolution and S/N ratio, the optical stellar spectrum of a galaxy can serve as an indicator of star formation rate.
基金This work was supported by the National Key Research and Development Program of China(2017YFB0902901)National Natural Science Foundation of China(51627811).
文摘Phasor measurement units(PMUs)provide useful data for real-time monitoring of the smart grid.However,there may be time-varying deviation in phase angle differences(PADs)between both ends of the transmission line(TL),which may deteriorate application performance based on PMUs.To address that,this paper proposes two robust methods of correcting time-varying PAD deviation with unknown parameters of TL(ParTL).First,the phenomena of time-varying PAD deviation observed from field PMU data are presented.Two general formulations for PAD estimation are then established.To simplify the formulations,estimation of PADs is converted into the optimal problem with a single ParTL as the variable,yielding a linear estimation of PADs.The latter is used by second-order Taylor series expansion to estimate PADs accurately.To reduce the impact of possible abnormal amplitude data in field data,the IGG(Institute of Geodesy&Geophysics,Chinese Academy of Sciences)weighting function is adopted.Results using both simulated and field data verify the effectiveness and robustness of the proposed methods.
文摘A novel approach to design Internal Model Controller(IMC)is proposed in this paper directly from measuredinput and output plant data,which are assumed to becontaminated by measurement noise.In order to avoidthe complicated structure-identification problem inmost cases,two Finite Impulse Response(FIR)modelsare taken to represent the plant model and the internalmodel controller respectively.Taking account of mea-surement noise both in the plant input and its output,anESD based Total Least Squares(TLS)solution is appliedfor the unbiased identification of the plant model and itsinverse model,the latter constitutes the internal modelcontroller according to the principle that the internalmodel controller approximates the inverse dynamics ofthe plant model.Simulations are given for a testifica-tion.