A Simple and Effective Surface Defect Detection Method of Power Line Insulators for Difficult Small Objects
1
作者 Xiao Lu Chengling Jiang +2 位作者 Zhoujun Ma Haitao Li Yuexin Liu 《Computers, Materials & Continua》 SCIE EI 2024年第4期373-390,共18页
Insulator defect detection plays a vital role in maintaining the secure operation of power systems.To address the issues of the difficulty of detecting small objects and missing objects due to the small scale,variable... Insulator defect detection plays a vital role in maintaining the secure operation of power systems.To address the issues of the difficulty of detecting small objects and missing objects due to the small scale,variable scale,and fuzzy edge morphology of insulator defects,we construct an insulator dataset with 1600 samples containing flashovers and breakages.Then a simple and effective surface defect detection method of power line insulators for difficult small objects is proposed.Firstly,a high-resolution featuremap is introduced and a small object prediction layer is added so that the model can detect tiny objects.Secondly,a simplified adaptive spatial feature fusion(SASFF)module is introduced to perform cross-scale spatial fusion to improve adaptability to variable multi-scale features.Finally,we propose an enhanced deformable attention mechanism(EDAM)module.By integrating a gating activation function,the model is further inspired to learn a small number of critical sampling points near reference points.And the module can improve the perception of object morphology.The experimental results indicate that concerning the dataset of flashover and breakage defects,this method improves the performance of YOLOv5,YOLOv7,and YOLOv8.In practical application,it can simply and effectively improve the precision of power line insulator defect detection and reduce missing detection for difficult small objects. 展开更多
关键词 Insulator defect detection small object power line deformable attention mechanism
下载PDF
A Two-Layer Active Power Optimization and Coordinated Control for Regional Power Grid Partitioning to Promote Distributed Renewable Energy Consumption
2
作者 Wentao Li Jiantao Liu +3 位作者 Yudun Li GuoxinMing Kaifeng Zhang Kun Yuan 《Energy Engineering》 EI 2024年第9期2479-2503,共25页
With the large-scale development and utilization of renewable energy,industrial flexible loads,as a kind of loadside resource with strong regulation ability,provide new opportunities for the research on renewable ener... With the large-scale development and utilization of renewable energy,industrial flexible loads,as a kind of loadside resource with strong regulation ability,provide new opportunities for the research on renewable energy consumption problem in power systems.This paper proposes a two-layer active power optimization model based on industrial flexible loads for power grid partitioning,aiming at improving the line over-limit problem caused by renewable energy consumption in power grids with high proportion of renewable energy,and achieving the safe,stable and economical operation of power grids.Firstly,according to the evaluation index of renewable energy consumption characteristics of line active power,the power grid is divided into several partitions,and the interzone tie lines are taken as the optimization objects.Then,on the basis of partitioning,a two-layer active power optimization model considering the power constraints of industrial flexible loads is established.The upper-layer model optimizes the planned power of the inter-zone tie lines under the constraint of the minimum peak-valley difference within a day;the lower-layer model optimizes the regional source-load dispatching plan of each resource in each partition under the constraint of theminimumoperation cost of the partition,so as to reduce the line overlimit phenomenon caused by renewable energy consumption and save the electricity cost of industrial flexible loads.Finally,through simulation experiments,it is verified that the proposed model can effectively mobilize industrial flexible loads to participate in power grid operation and improve the economic stability of power grid. 展开更多
关键词 Renewable energy consumption active power optimization power grid partitioning industrial flexible loads line over-limit
下载PDF
A Miniaturized Broadband Wilkinson Power Divider Using Micro-Strip Branch Lines
3
作者 Taifu Zhou 《Journal of Computer and Communications》 2023年第12期102-108,共7页
A miniaturized broadband Wilkinson power divider is proposed. Micro-strip branch lines are introduced to replace multiple resistors used in multi-stage Wilkinson power dividers to increase the bandwidth of single-stag... A miniaturized broadband Wilkinson power divider is proposed. Micro-strip branch lines are introduced to replace multiple resistors used in multi-stage Wilkinson power dividers to increase the bandwidth of single-stage Wilkinson power dividers. To demonstrate its performance, an improved single-stage Wilkinson power divider with four micro-strip branch lines was designed. Simulated results show that the insert loss is better than 3.2 dB, the input return loss, output return loss, and isolation are better than 15 dB respectively, across a 76% bandwidth from 18 to 40 GHz. . 展开更多
关键词 BROADBAND Micro-Strip Branch lines power Divider
下载PDF
Performance Evaluation for Medium Voltage MIMO-OFDM Power Line Communication System 被引量:10
4
作者 Yingxue Li Min Zhang +3 位作者 Wenguang Zhu Mengyuan Cheng Cheng Zhou Yongpeng Wu 《China Communications》 SCIE CSCD 2020年第1期151-162,共12页
Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)s... Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)scenario due to the fast development of in-home PLC.The aim of this paper is to evaluate the link-level performance of a medium voltage(MV)MIMO-OFDM communication system based on transmission link under underground power line channel.The MIMO channel is modeled as a modified multipath model in the presence of impulsive noise and background noise.We first perform a measurement on the practical MV MIMO channel parameters for a section of buried cable of 1 km long in Ganzhou city,Jiangxi province,China.Based on the measured channel,we design the frame structure based on an IEEE standard for broadband over power line networks[1]to support MV MIMO-OFDM transmission.According to designed frame structure,we design an encoder and a decoder for a dual binary tail-biting turbo code and optimize some key decoder parameters for low bit error rate performance.Finally,the link-level performance for both spatial multiplexing and spatial diversity are evaluated.Numeral results show that MV MIMO-OFDM is a promising approach to provide both high data rate and link reliability for PLC. 展开更多
关键词 power line communication(PLC) MIMO-OFDM multi-conductor medium voltage underground cables turbo code
下载PDF
Dynamic Balance Control Based on an Adaptive Gain-scheduled Backstepping Scheme for Power-line Inspection Robots 被引量:6
5
作者 Songyi Dian Lin Chen +2 位作者 Son Hoang Ming Pu Junyong Liu 《IEEE/CAA Journal of Automatica Sinica》 EI CSCD 2019年第1期198-208,共11页
This paper presents an adaptive gain-scheduled backstepping control(AGSBC) scheme for the balance control of an underactuated mechanical power-line inspection(PLI) robotic system with two degrees of freedom and a sing... This paper presents an adaptive gain-scheduled backstepping control(AGSBC) scheme for the balance control of an underactuated mechanical power-line inspection(PLI) robotic system with two degrees of freedom and a single control input.First, a nonlinear dynamic model of the balance adjustment process of the PLI robot is constructed, and then the model is linearized at a nominal equilibrium point to overcome the computational infeasibility of the conventional backstepping technique. Second, to solve generalized stabilization control issue for underactuated systems with multiple equilibrium points,an equilibrium manifold linearized model is developed using a scheduling variable, and then a gain-scheduled backstepping control(GSBC) scheme for expanding the operational area of the controlled system is constructed. Finally, an adaptive mechanism is proposed to counteract the impact of external disturbances. The robust stability of the closed-loop system is ensured by Lyapunov theorem. Simulation results demonstrate the effectiveness and high performance of the proposed scheme compared with other control schemes. 展开更多
关键词 Adaptive BACKSTEPPING BALANCE control gain-scheduled inspection robot power line
下载PDF
The changing process and trend of ground temperature around tower foundations of Qinghai-Tibet Power Transmission line 被引量:3
6
作者 YanLi Xie QiHao Yu +2 位作者 YanHui You ZhongQiu Zhang TingTao Gou 《Research in Cold and Arid Regions》 CSCD 2019年第1期13-20,共8页
After the construction of Qinghai-Tibet Highway and Railway, the Qinghai-Tibet Power Transmission(QTPT) line is another major permafrost engineering project with new types of engineering structures. The changing proce... After the construction of Qinghai-Tibet Highway and Railway, the Qinghai-Tibet Power Transmission(QTPT) line is another major permafrost engineering project with new types of engineering structures. The changing process and trend of ground temperature around tower foundations are crucial for the stability of QTPT. We analyzed the change characteristics and tendencies of the ground temperature based on field monitoring data from 2010 to 2014. The results reveal that soil around the tower foundations froze and connected with the artificial permafrost induced during the construction of footings after the first freezing period, and the soil below the original permafrost table kept freezing in subsequent thawing periods. The ground temperature lowered to that of natural fields, fast or slowly for tower foundations with thermosyphons,while for tower foundations without thermosyphons, the increase in ground temperature resulted in higher temperature than that of natural fields. Also, the permafrost temperature and ice content are significant factors that influence the ground temperature around tower foundations. Specifically, the ground temperature around tower foundations in warm and ice-rich permafrost regions decreased slowly, while that in cold and ice poor permafrost regions cooled faster. Moreover, foundations types impacted the ground temperature, which consisted of different technical processes during construction and variant of tower footing structures. The revealed changing process and trend of the ground temperature is beneficial for evaluating the thermal regime evolution around tower foundations in the context of climate change. 展开更多
关键词 Qinghai-Tibet power Transmission line TOWER FOUNDATION ground temperature change CHARACTERISTIC TREND
下载PDF
Extraction and analysis of tree canopy height information in high-voltage transmission-line corridors by using integrated optical remote sensing and LiDAR
7
作者 Jinpeng Hao Xiuguang Li +4 位作者 Hong Wu Kai Yang Yumeng Zeng Yu Wang Yuanjin Pan 《Geodesy and Geodynamics》 EI CSCD 2023年第3期292-303,共12页
Traditional inspection methods cannot quickly and accurately monitor tree barriers and safeguard the transmission lines.To solve these problems,in this study,we proposed a rapid canopy height information extraction me... Traditional inspection methods cannot quickly and accurately monitor tree barriers and safeguard the transmission lines.To solve these problems,in this study,we proposed a rapid canopy height information extraction method using optical remote sensing and LiDAR,and used UAV optical imagery with LiDAR to monitor the height of trees in a university and a high-voltage transmission line corridor in the Ningxia region.The results showed that the relative error of tree height extraction using UAV optical images was less than 5%,and the lowest relative error was 0.11%.The determination coefficient R^(2) between the optical image tree height extraction results and the measured tree height was 0.97,thus indicating a high correlation for both.In the field of tree barrier monitoring,the determination coefficient R^(2) of tree height extracted using airborne LiDAR point cloud,and canopy height model(CHM)and of the measured tree height were 0.947 and 0.931,respectively.The maximum and minimum relative error in tree height extraction performed using point cloud was 2.91%and 0.2%,respectively,with an extraction accuracy of over 95%.The experimental results demonstrated that it is feasible to use UAV optical remote sensing and LiDAR in monitoring tree barriers and tree height information extraction quickly and accurately,which is of great significance for the risk assessment and early warning of tree barriers in transmission-line corridors. 展开更多
关键词 UAV LIDAR power line Tree height
下载PDF
Minimization of Electric Power Losses on 132 kV and 220 kV Uganda Electricity Transmission Lines
8
作者 Ounyesiga Living Stephen Ndubuisi Nnamchi +2 位作者 Kelechi John Ukagwu Abubakar Abdulkarim Zaid Oluwadurotimi Jagun 《Energy and Power Engineering》 CAS 2023年第2期127-150,共24页
The classical minimization of power losses in transmission lines is dominated by artificial intelligence techniques, which do not guarantee global optimum amidst local minima. Revolutionary and evolutionary techniques... The classical minimization of power losses in transmission lines is dominated by artificial intelligence techniques, which do not guarantee global optimum amidst local minima. Revolutionary and evolutionary techniques are encumbered with sophisticated transformations, which weaken the techniques. Power loss minimization is crucial to the efficient design and operation of power transmission lines. Minimization of losses is one way to meet steady grid supply, especially at peak demand. Thus, this paper has presented a gradient technique to obtain optimal variables and values from the power loss model, which efficiently minimizes power losses by modifying the traditional power loss model that combines Ohm and Corona losses. Optimality tests showed that the unmodified model does not support the minimization of power losses on transmission lines as the Hessian matrix portrayed the maximization of power losses. However, the modified model is consistent with the gradient method of optimization, which yielded optimum variables and values from the power loss model developed in this study. The unmodified (modified) models for Bujagali-Kawanda 220 kV and Masaka West-Mbarara North 132 kV transmission lines in Uganda showed maximum power losses of 0.406 (0.391) and 0.452 (0.446) kW/km/phase respectively. These results indicate that the modified model is superior to the unmodified model in minimizing power losses in the transmission lines and should be implemented for the efficient design and operation of power transmission lines within and outside Uganda for the same transmission voltages. 展开更多
关键词 MINIMIZATION power Losses Transmission lines Corona and Ohms Losses Transmission Model
下载PDF
Multi-Equipment Detection Method for Distribution Lines Based on Improved YOLOx-s
9
作者 Lei Hu Yuanwen Lu +2 位作者 Si Wang Wenbin Wang Yongmei Zhang 《Computers, Materials & Continua》 SCIE EI 2023年第12期2735-2749,共15页
The YOLOx-s network does not sufficiently meet the accuracy demand of equipment detection in the autonomous inspection of distribution lines by Unmanned Aerial Vehicle(UAV)due to the complex background of distribution... The YOLOx-s network does not sufficiently meet the accuracy demand of equipment detection in the autonomous inspection of distribution lines by Unmanned Aerial Vehicle(UAV)due to the complex background of distribution lines,variable morphology of equipment,and large differences in equipment sizes.Therefore,aiming at the difficult detection of power equipment in UAV inspection images,we propose a multi-equipment detection method for inspection of distribution lines based on the YOLOx-s.Based on the YOLOx-s network,we make the following improvements:1)The Receptive Field Block(RFB)module is added after the shallow feature layer of the backbone network to expand the receptive field of the network.2)The Coordinate Attention(CA)module is added to obtain the spatial direction information of the targets and improve the accuracy of target localization.3)After the first fusion of features in the Path Aggregation Network(PANet),the Adaptively Spatial Feature Fusion(ASFF)module is added to achieve efficient re-fusion of multi-scale deep and shallow feature maps by assigning adaptive weight parameters to features at different scales.4)The loss function Binary Cross Entropy(BCE)Loss in YOLOx-s is replaced by Focal Loss to alleviate the difficulty of network convergence caused by the imbalance between positive and negative samples of small-sized targets.The experiments take a private dataset consisting of four types of power equipment:Transformers,Isolators,Drop Fuses,and Lightning Arrestors.On average,the mean Average Precision(mAP)of the proposed method can reach 93.64%,an increase of 3.27%.The experimental results show that the proposed method can better identify multiple types of power equipment of different scales at the same time,which helps to improve the intelligence of UAV autonomous inspection in distribution lines. 展开更多
关键词 Distribution lines UAV autonomous inspection power equipment detection YOLOx-s
下载PDF
Steady-state voltage-control method considering large-scale wind-power transmission using half-wavelength transmission lines 被引量:3
10
作者 Hao Tian Hongzheng Liu +3 位作者 Huan Ma Pengfei Zhang Xiaohui Qin Changhui Ma 《Global Energy Interconnection》 EI CAS CSCD 2021年第3期239-250,共12页
Half-wavelength transmission can transmit large-scale renewable energy over very long distances.This paper proposes an improved steady-state voltage-control method for half-wavelength transmission systems considering ... Half-wavelength transmission can transmit large-scale renewable energy over very long distances.This paper proposes an improved steady-state voltage-control method for half-wavelength transmission systems considering largescale wind-power transmission.First,the unique voltage characteristics of half-wavelength lines are deduced based on the distributed parameter model.In the secondary voltage-control level,reactive power-transmission limits of half-wavelength lines are introduced as another control objective except for tracing the pilot bus voltage reference.Considering the uncertainty and fluctuation of wind power,the overvoltage risk-assessment method of half-wavelength lines is presented to determine specific voltage-control strategies.Simulation results demonstrate that the proposed voltage-control method delivers superior tracking performance according to a voltage reference value and prevents the overvoltage risk of halfwavelength lines effectively in different wind-power penetrations. 展开更多
关键词 Half-wavelength lines Secondary voltage control Wind-power transmission Reactive power regulation
下载PDF
A FAST BIT-LOADING ALGORITHM FOR HIGH SPEED POWER LINE COMMUNICATIONS 被引量:2
11
作者 Zhang Shengqing Zhao Li Zou Cairong 《Journal of Electronics(China)》 2012年第5期461-468,共8页
Adaptive bit-loading is a key technology in high speed power line communications with the Orthogonal Frequency Division Multiplexing (OFDM) modulation technology. According to the real situation of the transmitting po... Adaptive bit-loading is a key technology in high speed power line communications with the Orthogonal Frequency Division Multiplexing (OFDM) modulation technology. According to the real situation of the transmitting power spectrum limited in high speed power line communications, this paper explored the adaptive bit loading algorithm to maximize transmission bit number when transmitting power spectral density and bit error rate are not exceed upper limit. With the characteristics of the power line channel, first of all, it obtains the optimal bit loading algorithm, and then provides the improved algorithm to reduce the computational complexity. Based on the analysis and simulation, it offers a non-iterative bit allocation algorithm, and finally the simulation shows that this new algorithm can greatly reduce the computational complexity, and the actual bit allocation results close to optimal. 展开更多
关键词 power line communications Orthogonal Frequency Division Multiplexing (OFDM) Bit-loading
下载PDF
抑制风电场经LCC-HVDC并网系统交流过电压的无功功率分散协同控制方法
12
作者 赵东君 郭春义 +3 位作者 叶全 樊鑫 赵峥 李探 《电力自动化设备》 EI CSCD 北大核心 2024年第1期88-94,共7页
针对风电场经基于电网换相换流器的高压直流(LCC-HVDC)并网系统换相失败导致的送端交流过电压问题,提出了无功功率分散协同控制方法。首先,研究了换相失败期间送端交流系统公共连接点(PCC)处电压和盈余无功功率特性。然后,从PCC处电压... 针对风电场经基于电网换相换流器的高压直流(LCC-HVDC)并网系统换相失败导致的送端交流过电压问题,提出了无功功率分散协同控制方法。首先,研究了换相失败期间送端交流系统公共连接点(PCC)处电压和盈余无功功率特性。然后,从PCC处电压和无功特性出发,基于无功-电压耦合关系及交流侧潮流方程,分别确定了基于本地功率电压特征的LCC整流站触发角及风电场站无功功率参考值,通过分散控制LCC和风电场实现协同抑制PCC处过电压的目的。最后,在PSCAD/EMTDC中搭建了风电场经LCC-HVDC并网系统模型并进行了仿真研究,结果表明所提出的分散协同控制方法可以有效抑制换相失败后恢复期间的交流过电压水平。 展开更多
关键词 风电场 电网换相换流器 交流过电压 无功功率分散 协同控制 换相失败
下载PDF
基于改进U-Net的轻量级输电线分割算法
13
作者 胡冠华 张永雷 申立群 《电子测量与仪器学报》 CSCD 北大核心 2024年第1期211-218,共8页
为了提高输电线路的巡检效率,保证输电线的分割精度和速度,本文提出基于改进U-Net的轻量级网络GU-Net。首先,以U-Net网络为基础,在编码器部分引入轻量化主干提取网络Ghost-Net;然后采用双线性插值方法完成上采样,并利用深度可分离卷积... 为了提高输电线路的巡检效率,保证输电线的分割精度和速度,本文提出基于改进U-Net的轻量级网络GU-Net。首先,以U-Net网络为基础,在编码器部分引入轻量化主干提取网络Ghost-Net;然后采用双线性插值方法完成上采样,并利用深度可分离卷积代替部分普通卷积;最后在训练过程引入多损失函数以解决输电线和背景像素占比不平衡问题,并采用迁移学习策略训练模型。在E-Wire输电线数据集上测试,GU-Net网络的MIoU和F1-score分别为80.04%和87.77%,与现有的轻量化输电线语义分割网络Wire-Detection相比分别提升了4.26%和2.96%,且分割速度几乎没有损失,参数量约是它的20%。实验结果表明,本文提出的算法能够实现快速高效、轻量化地分割出复杂图像中的输电线。 展开更多
关键词 深度学习 语义分割 编解码网络 轻量化 输电线路
下载PDF
A new type of Wilkinson dual-frequency power divider with symmetrical transmission line stubs
14
作者 丁尧舜 DONG Gang YANG Yin-tang 《Journal of Chongqing University》 CAS 2014年第1期17-25,共9页
To realize equal power splitting at two arbitrary gigahertz-frequencies, this paper presents a new type of Wilkinson dual frequency power divider, consisting of three-section transmission lines and a series RLC(resist... To realize equal power splitting at two arbitrary gigahertz-frequencies, this paper presents a new type of Wilkinson dual frequency power divider, consisting of three-section transmission lines and a series RLC(resistor, inductor and capacitor)circuit. By equating the [ABCD] matrix of the proposed circuit to that of the quarter-wave impedance transformer, coupled with even/odd mode analyses, the design equations of the proposed network are derived. For verification, two dual-frequency power dividers with dual-band operating frequencies at 0.6 GHz and 3.0 GHz, and 3.8 GHz and 10 GHz respectively are designed and simulated. Simulation results show that the dual-band ratio of the proposed power divider can be as large as 5. Comparisons of the simulation results at X-band and S-band with different power dividers indicate that the proposed dual-band power divider performs better under the scenario of the upper operating frequency extending to X-band. 展开更多
关键词 DUAL-FREQUENCY symmetrical transmission line stubs power divider ARBITRARY
下载PDF
Phase-Locked Loop Based Cancellation of ECG Power Line Interference
15
作者 LI Taihao ZHOU Jianshe +2 位作者 LIU Shupeng SHI Jinsheng REN Fuji 《ZTE Communications》 2018年第1期47-51,共5页
Power line(PL)interference is one significant artifact in electrocardiography(ECG)that needs to be reduced to ensure accurate recording of cardiac signals.Because PL interference is non-stationary and has varying freq... Power line(PL)interference is one significant artifact in electrocardiography(ECG)that needs to be reduced to ensure accurate recording of cardiac signals.Because PL interference is non-stationary and has varying frequency,phase,and amplitude in ECG measurement,adaptive techniques are often necessary to track and cancel the interference.In this paper we present a phase-locked loop(PLL)-based adaptive filter to cancel PL interference.The PLL obtains the reference signal that is fed into the adaptive filter to remove the PL interference at the central frequency of 50 Hz.It is found that the technique can effectively cancel PL interference in real ECG signals and,when compared with some existing techniques such as least mean squares(LMS)adaptive filter,the new technique produces better results in terms of signal-to-interference ratio(SIR). 展开更多
关键词 phase-locked LOOP ECG adaptive FILTER power line cancella-tion
下载PDF
Polar codes based OFDM-PLC systems in the presence of impulsive noise
16
作者 周玉 LI Yue +4 位作者 ZHAO Shuangshuang GAO Fan ZHOU Chao MU Zhuowen CHEN Rui 《High Technology Letters》 EI CAS 2024年第2期188-198,共11页
Power line communication(PLC)has the potential to become the preferred technique for providing broadband communication to homes and offices with advantage of eliminating the need for new wiring infrastructure and redu... Power line communication(PLC)has the potential to become the preferred technique for providing broadband communication to homes and offices with advantage of eliminating the need for new wiring infrastructure and reducing the cost.But it suffers from the impulsive noise because it introduces significant time variance into the power line channel.In this paper,a polar codes based orthogonal frequency division multiplexing(OFDM)PLC system is proposed to deal with the impulsive noise and thereby improve the transmission performance.Firstly,the impulsive noise is modelled with a multi-damped sine function by analyzing the time behavior of impulse events.Then the polar codes are used to combat the impulsive noise of PLC channel,and a low complexity bit-flipping decoding method based on CRC-aided successive cancellation list(CA-SCL)decoding algorithm is proposed.Simulations evaluate the proposed decoding algorithm and the results validate the suggested polar codes based OFDM-PLC scheme which can improve the BER performance of PLC with impulsive interference. 展开更多
关键词 orthogonal frequency division multiplexing(OFDM) polar code impulsivenoise power line communication(PLC) bit-flipping
下载PDF
Design of Power Supply for On-line Monitoring System of Transmission Lines
17
作者 Kai Chen Zi-jian Zhao +2 位作者 Yu-ning Zhang Yang-chun Cheng Yuan Dai 《Energy and Power Engineering》 2013年第4期570-574,共5页
This paper uses CT to gain the energy directly from the high-voltage transmission line, to address the problem of power supply for monitoring system in high voltage side of transmission line. The draw-out power coil c... This paper uses CT to gain the energy directly from the high-voltage transmission line, to address the problem of power supply for monitoring system in high voltage side of transmission line. The draw-out power coil can induce voltage from the transmission line, using single-chip microcomputer to analog and output PMW wave to control the charging module, provides a stable 3.4 V DC voltage to the load, and solve the problem of easy saturating of core. The power supply based on this kind of draw-out power coil has undergone the overall testing, and it is verified-showing that it can properly work in a non-saturated status within the current range of 50 - 1000 A, and provide a stable output. The equipment also design protection circuit to improve the reliability to avid the impacts of the impulse current or short-circuit current. It effectively solves the problem of power supply for On-line Monitoring System of Transmission. 展开更多
关键词 Monitoring System power Supply of HIGH-VOLTAGE Transmission line Draw-out power Coil SINGLE-CHIP MICROCOMPUTER
下载PDF
基于直流线路互联的区-隧供电系统弹性恢复策略
18
作者 孔惠文 马静 +1 位作者 程鹏 贾利民 《电工技术学报》 EI CSCD 北大核心 2024年第7期2089-2103,共15页
在“双碳”目标下,以服务区光伏车棚、光伏隧道为代表的能源交通融合供电场景逐步普及,这使得形态开放且布局分散的区-隧供电系统在面临极端灾害或人为攻击时更为脆弱。为此,该文提出一种基于直流线路互联的区-隧供电系统弹性恢复策略... 在“双碳”目标下,以服务区光伏车棚、光伏隧道为代表的能源交通融合供电场景逐步普及,这使得形态开放且布局分散的区-隧供电系统在面临极端灾害或人为攻击时更为脆弱。为此,该文提出一种基于直流线路互联的区-隧供电系统弹性恢复策略。根据灾害前对直流线路的改造与韧性加固计划,首先,提出了基于直流线路被优先遍历的可行拓扑搜索策略,用于保障所提系统在极端灾害后的有效互联;其次,基于对故障负荷重要级权重的多层级分类策略,该文先后以重要负荷恢复量最大化和系统额外损耗最小化为目标构建了故障恢复目标函数,共同保证极端灾害发生后系统基于稀缺分布式能源的最大弹性恢复;再次,基于传统二阶锥松弛方法可能挣脱原始约束的缺陷,提出通过约束额外损耗中流经电流分量实现对混合整数二阶锥规划问题的收敛,确保所提模型在不同初始条件下的稳定适用;最后,通过涵盖区-隧供电系统的改进IEEE 123节点配电网进行仿真,验证了所提策略的有效性。 展开更多
关键词 -隧供电系统 直流线路互联 深度优先遍历 弹性恢复
下载PDF
Science Letters:A power divider based on a new kind of composite right/left-handed transmission line (CRLH TL) unit 被引量:2
19
作者 李九生 邹勇卓 何赛灵 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2006年第1期1-4,共4页
A new power divider, composed of a novel composite right/left-handed (CRLH) transmission line (TL) unit, is proposed. The properties of the power divider based on four CRLH TL unit cells are investigated theoretically... A new power divider, composed of a novel composite right/left-handed (CRLH) transmission line (TL) unit, is proposed. The properties of the power divider based on four CRLH TL unit cells are investigated theoretically. By adjusting the parameters of the capacitors and the inductors, the power divider shows perfectly symmetric power division at 5.13 GHz, return loss up to ?24 dB, with the transmitted power being close to ?3.1 dB. The phenomena are demonstrated by simulation results. Being compact in size and low-cost, the proposed power divider is very suitable for microwave and millimeter wave integrated circuits. 展开更多
关键词 输电线路 CRLH 功率分配器 电容器 感应器
下载PDF
Low Complexity Discrete Bit-loading for OFDM Systems with Application in Power Line Communications
20
作者 Khalifa S. Al-Mawali Amin Z. Sadik Zahir M. Hussain 《International Journal of Communications, Network and System Sciences》 2011年第6期372-376,共5页
Adaptive bit-loading algorithms can improve the performance of OFDM systems significantly. The tradeoff between the performance of the algorithm and its computational complexity is essential for the implementation of ... Adaptive bit-loading algorithms can improve the performance of OFDM systems significantly. The tradeoff between the performance of the algorithm and its computational complexity is essential for the implementation of loading algorithms. In this paper, we present a low complexity non-iterative discrete bit-loading algorithm to maximize the data rate subject to specified target BER and uniform power allocation. Simulation results show that the proposed algorithm outperforms the equal-BER loading and achieves similar rates to incremental allocation, yet with much lower complexity. 展开更多
关键词 Bit-Loading OFDM power line COMMUNICATIONS
下载PDF