期刊文献+
共找到90篇文章
< 1 2 5 >
每页显示 20 50 100
Treating oil wastewater with pulse electro-coagulation flotation technology
1
作者 向亚芳 谢昭明 +1 位作者 ZOU Yong 《Journal of Chongqing University》 CAS 2010年第1期41-46,共6页
Pulse electro-coagulation flotation was used to treat oil wastewater of high oil content.Different operational conditions were examined,including current density,reactive time,electrode distance,pH and pole switching ... Pulse electro-coagulation flotation was used to treat oil wastewater of high oil content.Different operational conditions were examined,including current density,reactive time,electrode distance,pH and pole switching time.Orthogonal tests were carried out to identify the optimal operational conditions for this technique.Considering the treatment cost and efficiency together,the optimal operational conditions were an electrode distance of 3.3 cm,pH of 4,current density of 49.38 mA/cm2,reaction time of 15 min and pole switching time of 10 s.The removal efficiency of oil wastewater under normal conditions reached up to 96.21%.The influences of different factors on removal efficiency were in the following decreasing sequence:pH> current density > pole switching time > reactive time > board distance. 展开更多
关键词 oil wastewater electro-coagulation flotation oil removal efficiency
下载PDF
电解-Fenton法处理油田含油污水 被引量:13
2
作者 王永广 杨剑锋 柯洪 《扬州大学学报(自然科学版)》 CAS CSCD 2004年第4期79-82,共4页
采用电解-Fenton法进行了油田含油污水处理的试验研究.结果表明:该法对油田含油污水的处理效果显著,1 h反应后,污水中COD、含油量、细菌总数的去除率分别大于90%,95%,99%,反应形成的Fe(OH)3经过絮凝和酸度调节后可重复使用,污泥产量少.
关键词 油田含油污水 电解-Fenton法 去除率
下载PDF
聚结-气浮装置处理含油污水试验研究 被引量:5
3
作者 齐玉成 赵会军 +3 位作者 张璇 王永浩 彭浩平 丁宇 《安全与环境工程》 CAS 2016年第4期51-55,62,共6页
为提升聚结分离器除油效果并减少污水处理过程中化学药剂的投放,结合聚结和气浮技术研发出紧凑、高效型聚结-气浮分离装置,通过室内试验,考察入口流量、板间距、溶气压力、气浮水回流比4个因素对聚结-气浮装置除油率的影响规律,并对其... 为提升聚结分离器除油效果并减少污水处理过程中化学药剂的投放,结合聚结和气浮技术研发出紧凑、高效型聚结-气浮分离装置,通过室内试验,考察入口流量、板间距、溶气压力、气浮水回流比4个因素对聚结-气浮装置除油率的影响规律,并对其结构和工艺操作参数进行探索和优化。试验结果表明:聚结-气浮装置处理含油污水的油水分离效果明显好于聚结装置;聚结-气浮装置的除油率随入口流量、气浮水回流比的增加,均先增加后减小,并随溶气压力的增加而逐步提高,但当溶气压力为0.4MPa时继续加压,除油率变化不明显,且板间距越小,除油效果越好;综合除油效率和能耗,选用入口流量为0.3m3/h(折合板间流速为2.85m/h)、板间距为0.9cm、溶气压力为0.4MPa、气浮水回流比为20%时,聚结-气浮装置除油率可达92%,且对粒径大于18μm的油滴去除效果明显。 展开更多
关键词 聚结-气浮 油水分离 除油率 操作参数
下载PDF
旅大10-1平台污水处理效果影响因素分析 被引量:10
4
作者 段明 王虎 +2 位作者 张健 赵文森 檀国荣 《中国海上油气》 CAS 北大核心 2010年第6期420-423,共4页
对旅大10-1平台生产污水水质劣化、污水处理难度增大、处理后水质也时有超标情况发生的原因进行了分析。污水处理设施运行数据统计结果表明,三级处理中斜板除油器的除油率仅为40%左右,远低于设计水平;采用计算流体力学软件Fluent对斜板... 对旅大10-1平台生产污水水质劣化、污水处理难度增大、处理后水质也时有超标情况发生的原因进行了分析。污水处理设施运行数据统计结果表明,三级处理中斜板除油器的除油率仅为40%左右,远低于设计水平;采用计算流体力学软件Fluent对斜板除油器内部油水流动特性进行模拟分析认为,斜板除油器内波纹板的竖放方式是导致油水分离效率低的根本原因。在用清水剂BHQ-09的效能受到产出聚合物的影响。清水剂与防垢剂、防垢剂与杀菌剂之间不配伍进一步影响了污水处理效果。 展开更多
关键词 旅大10-1油田 污水处理 斜板除油器 油水分离效率 清水剂效能 化学剂配伍性
下载PDF
生物-非离子型表面活性剂对土壤石油污染的清除 被引量:6
5
作者 龙绛雪 傅海燕 +2 位作者 高攀峰 李岱霖 陈振兴 《湖北农业科学》 北大核心 2014年第6期1277-1280,1326,共5页
为了研究鼠李糖脂与化学型表面活性剂复配体系清除土壤石油污染的效果,以吐温和司盘系列非离子型表面活性剂为研究对象,通过动态接触角测量仪测定各单组分的胶束浓度,进而考察鼠李糖脂浸膏与4种非离子型表面活性剂的最佳复配比例,并对... 为了研究鼠李糖脂与化学型表面活性剂复配体系清除土壤石油污染的效果,以吐温和司盘系列非离子型表面活性剂为研究对象,通过动态接触角测量仪测定各单组分的胶束浓度,进而考察鼠李糖脂浸膏与4种非离子型表面活性剂的最佳复配比例,并对其模拟石油污染土壤的清除石油效果及影响因素进行评价。结果表明,二元复配的非离子型表面活性剂体系比单一组分的清除石油效果好,添加少量的鼠李糖脂可大幅度降低复配体系的表面张力,清除石油效果明显提高。当0.3 g/L鼠李糖脂与4.0 g/L司盘60复配、固液比为1∶20(m/V,g∶mL),水浴为70℃时,复配体系对石油的去除率达到79.64%,2次清洗对石油的去除率可提高到82.91%。 展开更多
关键词 鼠李糖脂 发酵浸膏 非离子型表面活性剂 复配体系 去油效率
下载PDF
界面性质对表面活性剂洗油效率影响研究
6
作者 葛巧玉 马涛 伦增珉 《当代化工》 CAS 2024年第6期1267-1271,共5页
表面活性剂通过改变油-水-岩石界面性质,可以提高稠油流动能力,促进采收率的提高。然而,界面相互作用力的改变对洗油效率和采收率的影响难以精确量化。提出了一种激光共聚焦成像及图像处理的方法分析洗油前后原油的分布,并计算洗油效率... 表面活性剂通过改变油-水-岩石界面性质,可以提高稠油流动能力,促进采收率的提高。然而,界面相互作用力的改变对洗油效率和采收率的影响难以精确量化。提出了一种激光共聚焦成像及图像处理的方法分析洗油前后原油的分布,并计算洗油效率。实验及计算结果显示,界面张力对洗油效率的影响较小,而系统润湿性和黏附功的影响更为显著。黏附功结合了表活剂对界面张力和润湿性的影响,是表活剂评价和筛选的一个重要参数。另外,固体表面的润湿反转使得表活剂的洗油效率随时间发生了改变。将洗油实验和激光共聚焦成像及图像处理相结合,精确计算了洗油效率,揭示了界面性质对洗油效率的影响,对化学驱提高稠油采收率具有重要指导意义。 展开更多
关键词 表面活性剂 界面张力 润湿性 黏附功 洗油效率
下载PDF
二硫代胺基甲酸盐类含油污水净化剂DTC-1 被引量:8
7
作者 宋莉晖 吴东平 张江 《油田化学》 CAS CSCD 北大核心 1998年第2期171-17,共1页
本文介绍了新型含油污水净化剂DTC1的制备方法、特点及其净水效果。结果表明,DTC1是一种投加量少、除油效率高的高效净水剂。
关键词 DCT-1 含油污水净化剂 油田
下载PDF
聚合氯化铝与CW-01阳离子破乳剂用于含油污水处理 被引量:2
8
作者 王慎敏 李建立 张宝杰 《哈尔滨理工大学学报》 CAS 1999年第6期45-48,共4页
为提高含油污水处理效果,解决乳化废水对生化系统的影响,选用了CW-01阳离子破乳剂与聚合氯化铝(PAC)进行复配。经对比实验及一系列条件试验表明:复配的最佳比例CW-01体积分数为8×10^(-3)~10×10^(-3)PAC质量浓度为30~5... 为提高含油污水处理效果,解决乳化废水对生化系统的影响,选用了CW-01阳离子破乳剂与聚合氯化铝(PAC)进行复配。经对比实验及一系列条件试验表明:复配的最佳比例CW-01体积分数为8×10^(-3)~10×10^(-3)PAC质量浓度为30~50mg·L(-1),油的去除率可达50%~66%,而且浮渣量少,是简便、经济的处理方法。 展开更多
关键词 CW-01破乳剂 聚合氯化铝 炼油厂 含油废水处理
下载PDF
Fe-Cu-C三元微电解—Fenton氧化深度处理含油废水的研究 被引量:4
9
作者 曹雨平 吴妍 《环境污染与防治》 CAS CSCD 北大核心 2012年第12期31-34,40,共5页
以某石化厂实际生产中经隔油、三级气浮处理后的含油废水(含油量为20~30mg/L)为处理对象,采用Fe-Cu-C三元微电解—Fenton氧化组合工艺进行处理,确定Fe-Cu-C三元微电解体系、Fenton氧化体系的最佳工艺条件。结果表明,Fe-Cu-C三元微电解... 以某石化厂实际生产中经隔油、三级气浮处理后的含油废水(含油量为20~30mg/L)为处理对象,采用Fe-Cu-C三元微电解—Fenton氧化组合工艺进行处理,确定Fe-Cu-C三元微电解体系、Fenton氧化体系的最佳工艺条件。结果表明,Fe-Cu-C三元微电解的最佳工艺条件:Fe/Cu/C为2∶1∶1(质量比),反应时间为45min,溶液初始pH为4,最佳工艺条件下出水除油率可达56%左右;三元微电解出水经Fenton氧化的最优条件:H2O2投加量为1.0mL/L,pH为5,氧化时间为40min,最优条件下的除油率可达到89%以上;采用Fe-Cu-C三元微电解—Fenton氧化组合工艺处理后总除油率可达94%~96%,最终出水含油量稳定在1~2mg/L。 展开更多
关键词 含油废水 三元微电解 FENTON氧化 正交实验 除油率
下载PDF
含聚污水斜管除油-过滤分离效率实验研究 被引量:4
10
作者 尹先清 靖波 +2 位作者 肖清燕 张健 孟凡雪 《过滤与分离》 CAS 2013年第2期1-3,17,共4页
含聚污水的高效分离处理是注聚采出液处理的热点难点之一。结合LD10-1平台斜管除油器V-3010的设计运行参数,探讨了污水含聚量为200 mg/L时、斜管除油器中斜管倾角600、500、450和污水停留分离时间20 min时的斜管除油率为60.8%~72.5%,... 含聚污水的高效分离处理是注聚采出液处理的热点难点之一。结合LD10-1平台斜管除油器V-3010的设计运行参数,探讨了污水含聚量为200 mg/L时、斜管除油器中斜管倾角600、500、450和污水停留分离时间20 min时的斜管除油率为60.8%~72.5%,悬浮物去除率为56.37%~66.21%;斜管倾角500时和污水停留分离时间15~40 min时的斜管除油率为59.8%~79.5%,悬浮物去除率为54.23%~73.48%。污水含聚量在50~600 mg/L变化时斜管倾角500的除油率为75.91~61.7%,模拟现场流程与核桃壳过滤器串联使用后,处理后水中粒径中值的分布范围0.972~26.16μm。 展开更多
关键词 含聚污水 斜管倾角 斜管除油器 分离效率 渤海LD10-1油田
下载PDF
CO_2-triggered gelation for mobility control and channeling blocking during CO_2 flooding processes 被引量:7
11
作者 De-Xiang Li Liang Zhang +2 位作者 Yan-Min Liu Wan-Li Kang Shao-Ran Ren 《Petroleum Science》 SCIE CAS CSCD 2016年第2期247-258,共12页
CO2 flooding is regarded as an important method for enhanced oil recovery (EOR) and greenhouse gas control. However, the heterogeneity prevalently dis- tributed in reservoirs inhibits the performance of this technol... CO2 flooding is regarded as an important method for enhanced oil recovery (EOR) and greenhouse gas control. However, the heterogeneity prevalently dis- tributed in reservoirs inhibits the performance of this technology. The sweep efficiency can be significantly reduced especially in the presence of "thief zones". Hence, gas channeling blocking and mobility control are important technical issues for the success of CO2 injection. Normally, crosslinked gels have the potential to block gas channels, but the gelation time control poses challenges to this method. In this study, a new method for selectively blocking CO2 channeling is proposed, which is based on a type of CO2-sensitive gel system (modified polyacry- lamide-methenamine-resorcinol gel system) to form gel in situ. A CO2-sensitive gel system is when gelation or solidification will be triggered by CO2 in the reservoir to block gas channels. The CO2-sensitivity of the gel system was demonstrated in parallel bottle tests of gel in N2 and CO2 atmospheres. Sand pack flow experiments were con- ducted to investigate the shutoff capacity of the gel system under different conditions. The injectivity of the gel system was studied via viscosity measurements. The results indi- cate that this gel system was sensitive to CO2 and had good performance of channeling blocking in porous media. Advantageous viscosity-temperature characteristics were achieved in this work. The effectiveness for EOR in heterogeneous formations based on this gel system was demonstrated using displacement tests conducted in double sand packs. The experimental results can provide guideli- nes for the deployment of theCO2-sensitive gel system for field applications. 展开更多
关键词 CO2 flooding Gas channeling - CO2sensitivity - Sweep efficiency Enhanced oil recoveryMobility control
下载PDF
Treatment of Dyes Wastewater by a New Kind of Bio - Fluid Bed
12
作者 黄永辉 奚旦立 《Journal of China Textile University(English Edition)》 EI CAS 2000年第3期120-122,共3页
A new kind of bio-fluid bed used to treat dyes wastewater is described in detail due to its several special features,such as high removal efficiency,simple struc-ture,shock load resistance,etc.By means of analyzing th... A new kind of bio-fluid bed used to treat dyes wastewater is described in detail due to its several special features,such as high removal efficiency,simple struc-ture,shock load resistance,etc.By means of analyzing the experiment data,the results show that the dye wastewater’s organic matter is removed greatly after be-ing treated by this new kind of bio-fluid bed.On the other hand,the removal efficiency of chromaticity of 展开更多
关键词 NEW BIO - fluid BED removal efficiency DYES wastewater.
下载PDF
旋流气浮装置内流动规律数值模拟 被引量:3
13
作者 王江云 魏浩然 +2 位作者 李佳奇 杨矞琦 王娟 《石油学报(石油加工)》 EI CAS CSCD 北大核心 2023年第3期587-598,共12页
采用欧拉多相流模型对一种旋流气浮装置内多相流动过程进行了数值模拟,鉴于在实际旋流气浮装置内油滴与气泡相互碰撞并黏附形成油-气混合相的流动特点,简化油-气-水三相流动为油-气混合相和水相的两相流动,依据实际除油效率确定油-气混... 采用欧拉多相流模型对一种旋流气浮装置内多相流动过程进行了数值模拟,鉴于在实际旋流气浮装置内油滴与气泡相互碰撞并黏附形成油-气混合相的流动特点,简化油-气-水三相流动为油-气混合相和水相的两相流动,依据实际除油效率确定油-气混合相密度,并以出油口分流比来表征装置中顶部出油口排出液与总排出液的质量流量比,然后考察了操作参数对旋流气浮装置性能的影响规律。结果表明:在含油污水处理量50~120 m^(3)/h范围内,旋流气浮装置的除油效率随着含油污水处理量的减小而增大;当出油口分流比处于0.001~0.020范围内时,装置除油效率随着出油口分流比增大而增大,但顶部出油口排出液的含油质量分数降低,综合考虑发现出油口分流比为0.010~0.015时,该旋流气浮装置的除油性能较佳。 展开更多
关键词 旋流气浮 数值模拟 除油效率 澄清效率 气浮浓缩倍数
下载PDF
惠州19-2油田水力旋流器调试实践 被引量:1
14
作者 程博 代文 《石油工业技术监督》 2015年第9期44-46,共3页
水力旋流器在油田采出液预分离和含油污水处理中逐步推广应用,对保护海洋生态环境、防止油田生产污水中石油烃含量超标起着关键作用。通过惠州19-2油田现场调试过程提出了水力旋流器的安装与调试方法,优化了水力旋流器的运行参数,通过... 水力旋流器在油田采出液预分离和含油污水处理中逐步推广应用,对保护海洋生态环境、防止油田生产污水中石油烃含量超标起着关键作用。通过惠州19-2油田现场调试过程提出了水力旋流器的安装与调试方法,优化了水力旋流器的运行参数,通过绘制水力旋流器工作效率曲线来确定最佳处理效果时的关键参数,以实现工况发生变化时水力旋流器的正常运转,保证油田生产水的达标排放。 展开更多
关键词 水力旋流器 除油效率 生产水 含油污水
下载PDF
转油站无伴热集输工艺改造的技术研究 被引量:3
15
作者 初旭 《石油石化节能与计量》 CAS 2023年第9期12-16,共5页
油田进入特高含水期后,含水率升高,但介质水力及热力条件得到改善,高含水率介质原油摩阻损失降低,为集输工艺优化提供了有力条件。目前集输系统普遍采用双管掺水集油工艺,工艺流程中掺水泵、热洗泵、掺水炉、热洗炉等设施,是最主要的耗... 油田进入特高含水期后,含水率升高,但介质水力及热力条件得到改善,高含水率介质原油摩阻损失降低,为集输工艺优化提供了有力条件。目前集输系统普遍采用双管掺水集油工艺,工艺流程中掺水泵、热洗泵、掺水炉、热洗炉等设施,是最主要的耗电及耗气节点;同时双管工艺复杂,站外掺水、热洗埋地管线较多,管道完整性管理及腐蚀失效治理工作量大。喇北北块地处高腐蚀区域,管道完整性改造工程量增加。生产实践中使用油井高效清蜡降黏装置及井口电加热器,以提高油井出油温度,满足集输温度要求,确保低产液井平稳运行;同时实施转油站无伴热集输工艺改造,取消双管掺水、热洗工艺,可有效降低转油站运行能耗、减少站外埋地管道工程量,实现转油站节能、高效运行。 展开更多
关键词 集输工艺 采出液 运行能耗 油井高效清蜡降黏装置 井口电加热器
下载PDF
油田注水采油中高压注水管网积垢清洗新技术研究与应用
16
作者 赵妮霞 申鹏 《四川化工》 CAS 2023年第4期16-20,共5页
为有效清除油田注水采油中注水管线的积垢,实现注水管线的畅通,保证注水质量,分析管道积垢机理及种类,研究清洁复合酸液清洗技术。该技术在S采油厂W注水站现场实施应用,清洗后的管线压差从平均2.57 MPa降至平均1.68 MPa,实施管线首末端... 为有效清除油田注水采油中注水管线的积垢,实现注水管线的畅通,保证注水质量,分析管道积垢机理及种类,研究清洁复合酸液清洗技术。该技术在S采油厂W注水站现场实施应用,清洗后的管线压差从平均2.57 MPa降至平均1.68 MPa,实施管线首末端悬浮物固体含量差值控制在10%以内,井口水质达标率提高20%,清洗效果达标,极大地提高了注水效率和生产效率,对油田实现降本增效具有一定的意义。 展开更多
关键词 油田注水采油 高压注水管线 积垢机理 清洁复合酸液清洗技术 现场应用 除垢率 注水效率
下载PDF
提高循环洗油洗苯效率的技改实践
17
作者 杜二冬 王跃欣 《煤化工》 CAS 2023年第5期45-49,共5页
介绍了洗油吸收负压脱苯工艺,分析了佳华公司洗油吸收负压脱苯工艺的运行状况,发现影响循环洗油洗苯效率的因素主要有循环洗油中萘含量、脱苯塔顶温度和循环洗油再生等。对洗油吸收负压脱苯工艺的工艺设备和参数进行了优化:将进厂洗油... 介绍了洗油吸收负压脱苯工艺,分析了佳华公司洗油吸收负压脱苯工艺的运行状况,发现影响循环洗油洗苯效率的因素主要有循环洗油中萘含量、脱苯塔顶温度和循环洗油再生等。对洗油吸收负压脱苯工艺的工艺设备和参数进行了优化:将进厂洗油中萘质量分数提高到5%~11%,通过新洗油少量多次加入、逐步调整粗苯回流量将脱苯塔顶温度控制在91℃~93℃,通过改造再生器排渣系统、将循环洗油再生量控制在1.5%~2.0%等,可将循环洗油洗苯效率控制在95%以上,系统运行稳定。 展开更多
关键词 洗油吸收 负压脱苯 含苯煤气 洗油再生 洗苯效率
下载PDF
首钢长治钢铁公司炼钢厂废水处理工程实例
18
作者 李芳 《山西冶金》 CAS 2023年第3期138-139,142,共3页
针对首钢长治钢铁公司炼钢厂废水处理站中废水含油、杂质多的特点,采用物理、化学结合处理方法,对相应的处理工艺流程、主要构筑物及相关设备进行设计改造。实际运行结果表明:该废水处理站运行稳定,处理工艺合理可靠,产水可代替新水用... 针对首钢长治钢铁公司炼钢厂废水处理站中废水含油、杂质多的特点,采用物理、化学结合处理方法,对相应的处理工艺流程、主要构筑物及相关设备进行设计改造。实际运行结果表明:该废水处理站运行稳定,处理工艺合理可靠,产水可代替新水用于高速过滤器、双旋流过滤器的反洗供水及连铸浊环水系统补水;运行费用为1.55元/t。 展开更多
关键词 含油废水 高效沉淀除油装置 气浮池 回用
下载PDF
Fenton试剂处理含油废水的实验研究 被引量:12
19
作者 郦和生 陈新芳 +2 位作者 刘伟 王岽 王洪英 《北京化工大学学报(自然科学版)》 EI CAS CSCD 北大核心 2007年第3期238-240,共3页
采用Fenton高级氧化技术对模拟含油废水进行了氧化处理,探讨了反应时间、pH值、温度、H2O2和Fe2+投加量等因素对油去除率的影响,确定了最佳处理条件。试验结果表明,在水样中油浓度为120 mg/L时,Fenton高级氧化反应最佳工艺条件为:c(H2O2... 采用Fenton高级氧化技术对模拟含油废水进行了氧化处理,探讨了反应时间、pH值、温度、H2O2和Fe2+投加量等因素对油去除率的影响,确定了最佳处理条件。试验结果表明,在水样中油浓度为120 mg/L时,Fenton高级氧化反应最佳工艺条件为:c(H2O2)=40 mmol/L,c(Fe2+)=4 mmol/L,pH=3.0,温度为30℃;反应2 h后,油的去除率达到最高值48.4%。这将为该工艺处理实际含油废水提供实验依据。 展开更多
关键词 FENTON试剂 含油废水 高级氧化技术 油去除率
下载PDF
电Fenton法处理采油废水的研究 被引量:6
20
作者 杨浩 呼世斌 +3 位作者 张凤梅 黄海波 李辰 李天枢 《西北农林科技大学学报(自然科学版)》 CSCD 北大核心 2013年第6期79-84,共6页
【目的】分析采用电Fenton法处理延长某油田采油废水时,各影响因素对废水污染物去除率的影响,旨在为采油废水的处理提供试验依据。【方法】先比较电Fenton法与Fenton法处理采油废水的效果,之后研究电流强度、H2O2质量浓度、H2O2与FeSO4... 【目的】分析采用电Fenton法处理延长某油田采油废水时,各影响因素对废水污染物去除率的影响,旨在为采油废水的处理提供试验依据。【方法】先比较电Fenton法与Fenton法处理采油废水的效果,之后研究电流强度、H2O2质量浓度、H2O2与FeSO4物质的量之比、pH值和板间距等影响因素对采油废水COD去除率的影响。【结果】比Fenton法相比,电Fenton法处理采油废水时的COD去除率明显提高;COD去除率随电流强度和H2O2质量浓度的增加而增大,在电流强度为1.5A、H2O2质量浓度为1 100mg/L时达到最大,之后继续增大电流强度和H2O2质量浓度则不利于反应的进行。当H2O2与FeSO4的物质的量之比为35∶1,30∶1,25∶1,20∶1时,随着FeSO4质量浓度的增大,COD去除率呈先增大后减小的趋势,H2O2与FeSO4的最佳物质的量之比为25∶1,此时FeSO4的质量浓度为196.7mg/L。随着pH增加,COD去除率先增加后减小,最优pH值为3。随着板间距的减小,COD去除率先增加后减小,最佳板间距为10mm。【结论】获得了电Fenton法处理采油废水的最佳条件,在此条件下COD的去除率可达到80%以上。 展开更多
关键词 电FENTON 采油废水 COD去除率
下载PDF
上一页 1 2 5 下一页 到第
使用帮助 返回顶部