期刊文献+
共找到29,556篇文章
< 1 2 250 >
每页显示 20 50 100
Comparative investigation of coal-and oil-fired boilers based on emission factors,ozone and secondary organic aerosol formation potentials of VOCs 被引量:7
1
作者 Hsi-Hsien Yang Sunil Kumar Gupta +2 位作者 Narayan Babu Dhital Lin-Chi Wang Suresh Pandian Elumalai 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2020年第6期245-255,共11页
Volatile organic compounds(VOCs)are the important precursors of the tropospheric ozone(O3)and secondary organic aerosols(SOA),both of which are known to harm human health and disrupt the earth’s climate system.In thi... Volatile organic compounds(VOCs)are the important precursors of the tropospheric ozone(O3)and secondary organic aerosols(SOA),both of which are known to harm human health and disrupt the earth’s climate system.In this study,VOC emission factors,O3 and SOA formation potentials were estimated for two types of industrial boilers:coal-fired boilers(n=3)and oil-fired boilers(n=3).Results showed that EVOCs concentrations were more than nine times higher for oil-fire d boilers compared to those for coal-fired boilers.Emission factors ofΣVOCs were found to be higher for oil-fired boilers(9.26-32.83 mg-VOC/kg)than for coal-fired boilers(1.57-4.13 mg-VOC/kg).Alkanes and aromatics were obtained as the most abundant groups in coal-fired boilers,while oxygenated organics and aromatics were the most contributing groups in oil-fired boilers.Benzene,n-hexane and o-ethyl toluene were the abundant VOC species in coal-fired boiler emissions,whereas toluene was the most abundant VOC species emitted from oil-fired boilers.O3 and SOA formation potentials were found 12 and 18 times,respectively,higher for oil-fired than for coal-fired boilers.Total OFP ranged from 3.99 to 11.39 mg-O3/kg for coal-fired boilers.For oil-fired boilers,total OFP ranged from 36.16 to 131.93 mg-O3/kg.Moreover,total secondary organic aerosol potential(SOAP)ranged from 65.4 to 122.5 mg-SOA/kg and 779.9 to 2252.5 mg-SOA/kg for the coal-fired and oil-fired boilers,respectively. 展开更多
关键词 Coal-and oil-fired boilers Volatile organic compounds Emission factor Ozone formation potential Secondary organic aerosol potential
原文传递
Environmental performance assessments of different methods of coal preparation for use in small-capacity boilers: experiment and theory
2
作者 A.N.Kozlov E.P.Maysyuk I.Yu.Ivanova 《International Journal of Coal Science & Technology》 EI CAS CSCD 2023年第5期57-71,共15页
The purpose of this article is to receive environmental assessments of combustion of different types of coal fuel depending on the preparation(unscreened,size-graded,briquetted and heat-treated)in automated boilers an... The purpose of this article is to receive environmental assessments of combustion of different types of coal fuel depending on the preparation(unscreened,size-graded,briquetted and heat-treated)in automated boilers and boilers with manual load-ing.The assessments were made on the basis of data obtained from experimental methods of coal preparation and calculated methods of determining the amount of pollutant and greenhouse gas emissions,as well as the mass of ash and slag waste.The main pollutants from coal combustion are calculated:particulate matter,benz(a)pyrene,nitrogen oxides,sulfur dioxide,carbon monoxide.Of the greenhouse gases carbon dioxide is calculated.As a result of conducted research it is shown that the simplest preliminary preparation(size-graded)of coal significantly improves combustion efficiency and environmental performance:emissions are reduced by 13%for hard coal and up to 20%for brown coal.The introduction of automated boil-ers with heat-treated coal in small boiler facilities allows to reduce emissions and ash and slag waste by 2-3 times.The best environmental indicators correspond to heat-treated lignite,which is characterized by the absence of sulfur dioxide emissions. 展开更多
关键词 Coal preparation Automated and hand-fed coal boilers Environmental performance metrics
下载PDF
Analysis of Prese nt Operating Situati on of Large Size Coal-F ired Utility Boilers
3
作者 许传凯 袁颖 《Electricity》 2003年第1期24-29,共6页
Large size utility boilers develop rapidly in China, both their reliability and economics have reached better level. The operating situations of various existing boilers on the basis of different coals are analyzed, i... Large size utility boilers develop rapidly in China, both their reliability and economics have reached better level. The operating situations of various existing boilers on the basis of different coals are analyzed, it is held that, the notable energy imbalance of furnace exit, ever existing in the tangential firing boilers has been solved, with comparatively lower NOX emission concentration of gained. The higher NOX emission concentration and furnace slagging etc. problems existing in wall firing boilers are notable. The comprehensive analysis shows that, it is appropriate to choose lower furnace volume heat release rate and higher flame height in the type selection design of boilers, and sufficient margin should be kept in the selection of coal pulverizing mills. 展开更多
关键词 coal-fired boiler operating performance COMBUSTION slagging and fouling NOX emission
下载PDF
INTRODUCTION TO INCONEL ALLOY 740: AN ALLOY DESIGNED FOR SUPERHEATER TUBING IN COAL-FIRED ULTRA SUPERCRITICAL BOILERS 被引量:19
4
作者 S.J. Patel 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2005年第4期479-488,共10页
Chinese utilities as well as those worldwide are facing increased demand for additional electricity, reduced plant emissions and greater efficiency. To meet this challenge will require increasing boiler temperature, p... Chinese utilities as well as those worldwide are facing increased demand for additional electricity, reduced plant emissions and greater efficiency. To meet this challenge will require increasing boiler temperature, pressure and coal ash corrosion resistance of the materials of boiler construction of future coal-fired boilers. A new nickel-based tube alloy, INCONEL^R alloy 740, is described aiming at meeting this challenge. Emphasis will be on describing the alloy' s mechanical properties, coal-ash and steam corrosion resistance. Microstructural stability as a function of temperature and time is addressed as well as some of the early methodology em- ployed to arrive at the current chemical composition. 展开更多
关键词 ultrasupercritical boiler tubing INCONEL coal-fired
下载PDF
Optimal dynamic dispatch of surplus gas among buffer boilers in steel plant 被引量:3
5
作者 孙文强 蔡九菊 《Journal of Central South University》 SCIE EI CAS 2013年第9期2459-2465,共7页
As valuable energy in iron-and steel-making process,by-product gas is widely used in heating and technical processes in steel plant.After being used according to the technical requirements,the surplus by-product gas i... As valuable energy in iron-and steel-making process,by-product gas is widely used in heating and technical processes in steel plant.After being used according to the technical requirements,the surplus by-product gas is usually used for buffer boilers to produce steam.With the rapid development of energy conservation technology and energy consumption level,surplus gas in steel plant continues to get larger.Therefore,it is significant to organize surplus gas among buffer boilers.A dynamic programming model of that issue was established in this work,considering the ramp rate constraint of boilers and the influences of setting gasholders.Then a case study was done.It is shown that dynamic programming dispatch gets more steam generation and less specific gas consumption compared with current proportionate dispatch depending on nominal capacities of boilers.The ignored boiler ramp rate constraint was considered and its contribution to the result validity was pointed out.Finally,the significance of setting gasholders was studied. 展开更多
关键词 surplus gas dynamic programming buffer boiler steel plant
下载PDF
NO_x emission model for coal-fired boilers using partial least squares and extreme learning machine 被引量:4
6
作者 Dong Ze Ma Ning Li Changqing 《Journal of Southeast University(English Edition)》 EI CAS 2019年第2期179-184,共6页
To implement a real-time reduction in NOx,a rapid and accurate model is required.A PLS-ELM model based on the combination of partial least squares(PLS)and the extreme learning machine(ELM)for the establishment of the ... To implement a real-time reduction in NOx,a rapid and accurate model is required.A PLS-ELM model based on the combination of partial least squares(PLS)and the extreme learning machine(ELM)for the establishment of the NOx emission model of utility boilers is proposed.First,the initial input variables of the NOx emission model are determined according to the mechanism analysis.Then,the initial input data is extracted by PLS.Finally,the extracted information is used as the input of the ELM model.A large amount of real data was obtained from the distributed control system(DCS)historical database of a 1 000 MW power plant boiler to train and validate the PLS-ELM model.The modeling performance of the PLS-ELM was compared with that of the back propagation(BP)neural network,support vector machine(SVM)and ELM models.The mean relative errors(MRE)of the PLS-ELM model were 1.58%for the training dataset and 1.69%for the testing dataset.The prediction precision of the PLS-ELM model is higher than those of the BP,SVM and ELM models.The consumption time of the PLS-ELM model is also shorter than that of the BP,SVM and ELM models. 展开更多
关键词 NOx emission partial least squares extreme learning machine coal-fired boiler
下载PDF
Optimization of Load Assignment to Boilers in Industrial Boiler Plants 被引量:1
7
作者 曹家枞 邱广 +1 位作者 曹双华 刘凤强 《Journal of Donghua University(English Edition)》 EI CAS 2004年第6期1-6,共6页
Along with the increasing importance of sustainable energy, the optimization of load assignment to boilers in an industrial boiler plant becomes one of the major projects for the optimal operation of boiler plants. Op... Along with the increasing importance of sustainable energy, the optimization of load assignment to boilers in an industrial boiler plant becomes one of the major projects for the optimal operation of boiler plants. Optimal load assignment for power systems has been a long-lasting subject, while it is quite new for industrial boiler plants. The existing methods of optimal load assignment for boiler plants are explained and analyzed briefly in the paper. They all need the fuel cost curves of boilers. Thanks to some special features of the curves for industrial boilers, a new model referred to as minimized departure model (MDM) of optimization of load assignment for boiler plants is developed and proposed in the paper. It merely relies upon the accessible data of two typical working conditions to build the model, viz. the working conditions with the highest efficiency of a boiler and with no-load. Explanation of the algorithm of computer program is given, and effort is made so as to determine in advance how many and which boilers are going to work. Comparison between the results using MDM and the results reported in references is carried out, which proves that MDM is preferable and practicable. 展开更多
关键词 Industrial boiler plants optimal load assignment coordination of INCREMENTAL fuel costs minimized DEPARTURE model
下载PDF
Shock resistance of supercharged boilers through integration with ship structure 被引量:1
8
作者 YAO Xiong-liang FENG Lin-han ZHANG A-man ZHOU Qi-xin 《Journal of Marine Science and Application》 2007年第4期18-26,共9页
The non-linear finite element software ABAQUS was used to simulate the dynamic response of a marine supercharged boiler when subjected to impact loading. Shock resistance was analyzed by the time-domain simulation met... The non-linear finite element software ABAQUS was used to simulate the dynamic response of a marine supercharged boiler when subjected to impact loading. Shock resistance was analyzed by the time-domain simulation method. After exhaustive simulations,the effect of air pressure induced by different working conditions on the shock response of a supercharged boiler was reviewed,leading to conclusions about the variability of structural response with different loading parameters. In order to simulate the real impulsive environments of supercharged boilers,the integration of equipment and ship structure was then primarily used to analyze shock response. These distinctly different equipment shock test methods,run under equivalent work conditions,were compared and the causes of discrepancy were analyzed. The main purpose of this paper is to present references for the anti-shock design of marine supercharged boilers. 展开更多
关键词 supercharged boiler numerical simulation dynamic response shock resistance integrationof equipment and ship structure
下载PDF
Fault Diagnostics on Steam Boilers and Forecasting System Based on Hybrid Fuzzy Clustering and Artificial Neural Networks in Early Detection of Chamber Slagging/Fouling 被引量:1
9
作者 Mohan Sathya Priya Radhakrishnan Kanthavel Muthusamy Saravanan 《Circuits and Systems》 2016年第12期4046-4070,共25页
The slagging/fouling due to the accession of fireside deposits on the steam boilers decreases boiler efficiency and availability which leads to unexpected shut-downs. Since it is inevitably associated with the three m... The slagging/fouling due to the accession of fireside deposits on the steam boilers decreases boiler efficiency and availability which leads to unexpected shut-downs. Since it is inevitably associated with the three major factors namely the fuel characteristics, boiler operating conditions and ash behavior, this serious slagging/fouling may be reduced by varying the above three factors. The research develops a generic slagging/fouling prediction tool based on hybrid fuzzy clustering and Artificial Neural Networks (FCANN). The FCANN model presents a good accuracy of 99.85% which makes this model fast in response and easy to be updated with lesser time when compared to single ANN. The comparison between predictions and observations is found to be satisfactory with less input parameters. This should be capable of giving relatively quick responses while being easily implemented for various furnace types. 展开更多
关键词 Steam boiler Fouling and Slagging Fuzzy Clustering Artificial Neural Networks
下载PDF
R&D and Demonstration of Large Domestic CFB Boilers 被引量:1
10
作者 Sun Xianbin1, Jiang Minhua1, Yu Long2, Li Guanghua3, Shi Zhenghai1, Zhang Yanjun2, Jiang Yuanjian4, Li Zhiwei1, Jiang Xiaoguo2 and Zou Shengfa4. 1. Xi’an Thermal Power Research Institute Co., Ltd. 2. Harbin Bolier Co., Ltd. 3. China Power Investment Corporation 4. Jiangxi Fenyi Power Plant Co., Ltd. Wang Ningling 《Electricity》 2008年第3期32-35,共4页
In order to develop large CFB boilers with independent intellectual property, Xi'an Thermal Power Research Institute (TPRI) established a laboratory with complete functions for the technical development of CFB boi... In order to develop large CFB boilers with independent intellectual property, Xi'an Thermal Power Research Institute (TPRI) established a laboratory with complete functions for the technical development of CFB boilers. This laboratory consists of a 1-MW and a 4-MW CFB combustion test facilities and a laboratory for limestone desulphurization performance evaluation. It carried out tests on CFB combustion and desulphurization for Chinese typical coals and limestone and research on heat-transfer characteristics and key parts, and developed the first home-made 100-MW CFB boiler. Based on the experience of R&D, the laboratory further researched key techniques for enlarging capacity systematically, and cooperating with Harbin Boiler Co. (HBC), developed the first domestic 210-MW CFB boiler with independent intellectual property and put it into engineering demonstration, laying a solid foundation for the development of CFB boilers of even larger capacity. 展开更多
关键词 CFB R&D and Demonstration of Large Domestic CFB boilers
下载PDF
Development of 600 MW Class Coal Fired Boilers in China
11
作者 Xu Chuankai Xu Yunsong(Thermal Power Research institute, Xi’an, China) 《Electricity》 1999年第3期16-22,共7页
This article introduces the present status anddevelopment of 600 MW class boilers in China. The statisticaldata indicate that most 600 MW generating units experiencedrelatively length" growing up" period. In... This article introduces the present status anddevelopment of 600 MW class boilers in China. The statisticaldata indicate that most 600 MW generating units experiencedrelatively length" growing up" period. In this period, unitscould not operate stably , their unplanned outage times weremany and durations long, and availabilities low. On the basis oftesting and research and the summing-up of practice, it wasindicated slagging in the furnace, deviation of tine gas energy atthe exit of furnace, and overheating bursting of superheater andreheater etc, endangering the safety and economics ofoperation,main problems could be completely alleviated oravoided through design and type selection of boiler furnace andburners, coal characteristics and coal handling management,and optimization management of operation conditions etc. 展开更多
关键词 coal-fired boiler SLAGGING energy deviation of fluegas tube failure coupling of COAL property-boiler type
下载PDF
Atmospheric Dry Deposition in the Proximity of Oil-Fired Power Plants at Mexican Pacific Coast
12
作者 R. M. Cerón J. G. Cerón +6 位作者 C. Aguilar C. Montalvo C. Carballo B. Cárdenas A. Ortinez M. Cocom J. Carrillo 《Journal of Environmental Protection》 2012年第9期1228-1237,共10页
Dry deposition samples were collected in a weekly basis during 2010 in a site located at the Mexican Pacific Coast: Manzanillo, Colima. Samples were collected with an automatic wet/dry deposition sampler using nylon f... Dry deposition samples were collected in a weekly basis during 2010 in a site located at the Mexican Pacific Coast: Manzanillo, Colima. Samples were collected with an automatic wet/dry deposition sampler using nylon filters as surrogate surfaces. Samples were extracted with deionized water and analyzed for pH, conductivity, Na+, K+, Ca2+, Mg2+, NH4-, NO3-, SO42- and Cl-. Nitrate and sulfate were the most abundant ions, contributing with 53% to the total ionic mass;and their levels exceeded the hemispheric background concentrations proposed for marine remote sites. The influence of the power plants burning combustoleo located upwind the sampling site was completely evident. From meteorological analysis, it could be observed that the sampling site was all time under the influence of power plants as a result of the effect of breezes. However, in spite of the high levels of NO3- and SO42- found in the samples collected, pH value average was almost neutral, with 28% of samples slightly acid. Potassium was the most abundant cation and from the quantification of the neutralization effect of the main alkaline components, the prevalence role of K+ was completely evident, suggesting the influence of the mining complex Pe?a Colorada located upwind the sampling site, where amyl xanthate potassium is used as collector in tailing dams. Dry deposition fluxes were estimated for all ions measured. Nitrogen dry deposition at Manzanillo is already in the upper extreme of the threshold value reported for sensible ecosystems. On the other hand, sulfur deposition exceeded slightly the critical load value reported for some ecosystems in Europe. Even at this moment, nitrogen and sulfur deposition is not a problem, it is necessary to take steps to avoid that total deposition of these elements exceeds critical loads, considering that results reported in this study not include the wet deposition fluxes. 展开更多
关键词 DRY Deposition DRY FLUXES oil-fired Power Plants Combustoleo Mexico
下载PDF
Development and Installation of High Pressure Boilers for Co-Generation Plant in Sugar Industries
13
作者 Kolar Seenappa Venkatesh Aashis S. Roy 《Smart Grid and Renewable Energy》 2010年第1期51-53,共3页
The sugar cane containing minimum 30% fiber was referred as bagasse and used the generation of power required for the operation of sugar mill. The bagasse is fired in the boiler for producing steam at high pressure, w... The sugar cane containing minimum 30% fiber was referred as bagasse and used the generation of power required for the operation of sugar mill. The bagasse is fired in the boiler for producing steam at high pressure, which is extracted through various single high capacity turbines and used in the process. The installation of high pressure boilers and high pressure turbo-generators has provision for the operation of co-generation plant during the off-season also that enhances the power generation from 9MW to 23MW. The annual monetary benefits achieved are Rs. 204.13 million and this was based on cost of power sold to the grid @ Rs 2.548 per unit, sugar season of 219 days and off season of 52 days. This required an investment of Rs 820.6 million. The investment had an attractive simple payback period of 48 months. 展开更多
关键词 High Pressure boiler CO-GENERATION PLANT SUGAR INDUSTRIES Steam Turbine BAGASSE Dc Drives.
下载PDF
Smart Boilers: Grid Support Services from Non-Critical Loads
14
作者 Panagis N. Vovos Konstantinos G. Georgakas 《Journal of Power and Energy Engineering》 2020年第12期23-45,共23页
The aim of this paper is to present the concept of a simple and cheap upgrade for electric water boilers, allowing them to provide power quality services to the distribution grid. The upgrade requires only minimum add... The aim of this paper is to present the concept of a simple and cheap upgrade for electric water boilers, allowing them to provide power quality services to the distribution grid. The upgrade requires only minimum additional hardware and it is easily installable. “Smart Boilers”, as the upgraded boilers are named, perform precise active and reactive power control, but most significantly mitigate line current harmonics. Αctive and reactive power control is implemented by appropriate regulation of the modulation sinewave amplitude and phase, respectively. This type of control is easily customizable in order to accommodate a variety of power quality targets, depending on the required level of services and available grid monitoring equipment. The method used for line current harmonic compensation is based on the injection of mirror harmonics created at the modulation stage of the converter. It is indifferent of harmonic source: it is equally successful at mitigating harmonics caused by the power electronic converter of the Smart Boiler, other sources of current harmonics or loads. The achieved grid services are clearly beyond the “on/off” operation of electric boilers, currently implemented by Demand Side Management (DSM) in order to shift load away from peak hours. It has been demonstrated through simulations, that Smart Boilers can assist voltage regulation at terminal buses, compensate reactive power and suppress harmonic currents at lines. 展开更多
关键词 Electrical Grid Improvement High Harmonics Minimization Smart boilers Smart Power Grids Active Power Control Reactive Power Compensation
下载PDF
800-MW Supercritical Coal-Fired Boilers in Suizhong Power Plant
15
作者 ZouHaifeng LiZhishan LiuZhongqi 《Electricity》 2005年第2期30-33,共4页
This article reviews the problems of Russia-made 800-MW coal-fired supercritical boilers in Suizhong Power Plant, such as burner bumout, water-wall leakage, slag screenⅠexplosion, crack happened on the desuperheater ... This article reviews the problems of Russia-made 800-MW coal-fired supercritical boilers in Suizhong Power Plant, such as burner bumout, water-wall leakage, slag screenⅠexplosion, crack happened on the desuperheater outlet of reheater and welding defect of economizer; tells the process of renovating these units by modifying the original design and adjusting the operation parameters. After several years' effort, all the problems have been well solved. The experience may be useful for other imported units in China. 展开更多
关键词 supercritical boiler boiler operation boiler tube leakage
下载PDF
Work Boilers in the Real Heat Loads
16
作者 Rafal Urbaniak Jaroslaw Bartoszewicz 《Journal of Mechanics Engineering and Automation》 2013年第2期121-126,共6页
Analysis was performed on the boiler for solid fuels in a corresponding real-thermal load. The tests were conducted with the use of a low-temperature top-loading KWSM water boiler. For control of the burning process, ... Analysis was performed on the boiler for solid fuels in a corresponding real-thermal load. The tests were conducted with the use of a low-temperature top-loading KWSM water boiler. For control of the burning process, three control algorithms were used as implemented in microprocessor temperature controls. The analysis aimed at determination of influence of the control algorithm upon quality of the buming process in conditions of actual demand for thermal energy. The detailed analysis of operating parameters in relation to the variable thermal load of the boiler provided necessary information and made it possible to state that control algorithms do influence quality of the controlled process. Particular attention was paid to a situation, in which demand for thermal energy is decreased. 展开更多
关键词 boilers COAL power control emission of pollution.
下载PDF
Correlating furnace characteristics of utility boilers with coal characteristics
17
作者 Xie Yulin Chen Chunyuan Hu Rende Power Coal Combustion Development Center 《Electricity》 1992年第1期1+45-50,共7页
1.IntroductionCoal is listed in China’s energy policy as the predominant fuelto be used for thermal power generation.It includes nearly the wholespectrum of coals that China has,ranging from anthracite to browncoal.T... 1.IntroductionCoal is listed in China’s energy policy as the predominant fuelto be used for thermal power generation.It includes nearly the wholespectrum of coals that China has,ranging from anthracite to browncoal.This poses a situation to China’s utility boiler manufacturers thattheir products have to cope with all kinds of coal available.China is now producing a full range of utility boilers with ca-pacities from 35 t/h through 2000 t/h.They have successfully burnedanthracities with volatile matter greater than 7% and low grade coalswith high moisture and high ash contents.They burn bituminouscoals and lignites with satisfactory efficacy. 展开更多
关键词 utility boiler satisfactory FURNACE VOLATILE moisture producing LISTED ignition BURNING
下载PDF
Power Generation Systems Using Continuous Blowdown Waste Heat from Drum Boilers Driving an Organic Rankine Cycle 被引量:2
18
作者 LIU Qiang DUAN Yuanyuan WAN Xucai 《中国电机工程学报》 EI CSCD 北大核心 2013年第35期I0001-I0014,共14页
提出了一种利用汽包锅炉排污系统余热的有机朗肯循环发电系统,有机工质回收扩容器疏水的热量,并通过气轮机发电。建立了系统的热力性能分析模型,并对R227ea、RC318、R236ea、R245fa、R245ca、R123和R113等7种工质的热力性能进行了优化... 提出了一种利用汽包锅炉排污系统余热的有机朗肯循环发电系统,有机工质回收扩容器疏水的热量,并通过气轮机发电。建立了系统的热力性能分析模型,并对R227ea、RC318、R236ea、R245fa、R245ca、R123和R113等7种工质的热力性能进行了优化。结果表明,临界温度高的工质,其o2循环的最佳主气温度(蒸发温度)反而低;亚临界循环采用干流体时,过热不利于余热的利用;超临界循环可以改善热源与工质间的温度匹配,有利于增大系统输出功,但是其运行压力高、大比热区的传热恶化等问题是实际运行和设计需要考虑的因素;R236ea的热力性能优于其余6种工质。 展开更多
关键词 朗肯循环 余热驱动 连续排污 发电系统 锅炉 燃煤电厂 标准煤耗率 发电量
下载PDF
Discussion on Selection of Pulverizer and Moisture of Pulverized Coal for Lignite Boilers
19
作者 Zhang Yun Li Weidong +1 位作者 Xu Chuankai Zhang Jingwu 《Electricity》 2012年第4期25-30,共6页
In China,the abrasion index and the free moisture are regarded as the criteria for determining whether the medium-speed pulverizer or the fan pulverizer could be selected.Based on comprehensive studies on foreign meth... In China,the abrasion index and the free moisture are regarded as the criteria for determining whether the medium-speed pulverizer or the fan pulverizer could be selected.Based on comprehensive studies on foreign methods for choosing the pulverizing system for lignite boilers,it is suggested that the particle size of coal,the drying time,the drying temperature and the humidity should be taken into account when measuring the free moisture of lignite,and the total moisture could also be the principle for type selection of pulverizer for lignite boilers.Furthermore,the determination of pulverized-coal moisture has great influence on the running of pulverizing systems.The actual moisture of certain pulverized coals is compared with that calculated with different methods and a feasible method for determining the moisture of the pulverized coal is suggested. 展开更多
关键词 lignite boiler type selection of pulverizer moisture of pulverized coal
下载PDF
Effects of particle type on the particle fluidization and distribution in a liquid–solid circulating fluidized bed boiler
20
作者 Feng Jiang Xiao Li +1 位作者 Guopeng Qi Xiulun Li 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第2期53-66,共14页
A liquid-solid circulating fluidized bed boiler is designed and built for visualization research by applying the fluidized bed heat transfer and fouling prevention technology to the water side of the boiler. Four type... A liquid-solid circulating fluidized bed boiler is designed and built for visualization research by applying the fluidized bed heat transfer and fouling prevention technology to the water side of the boiler. Four types of engineering plastic particles with different physical properties are selected as the solid working media. The effect of particle types on the fluidization and distribution of particles in the boiler is investigated under different feedwater flow rates and amount of added particles by using the charge couple device image measurement and acquisition system. The results show that all kinds of particles can't be normally fluidized and accumulate in the drum at low amount of added particles and feedwater flow rate. The particles with great density and low sphericity are more likely to accumulate. The average solid holdup in the riser tubes increases with the increase in feedwater flow rate and the amount of added particles. The non-uniform degree of particle distribution in the riser tubes generally decreases with the increase in feedwater flow rate and the amount of added particles. The particles with small density and settling velocity have high average solid holdup in the riser tubes under close sphericity. In generally,the smaller the density and settling velocity, the more uniform the particle distribution in the riser tubes.Three-dimensional diagrams of the non-uniform degree of particle distribution in the riser tubes of the boiler are established. 展开更多
关键词 Circulating fluidized bed boiler Particle type Particle distribution Visualization Fouling prevention
下载PDF
上一页 1 2 250 下一页 到第