期刊文献+
共找到246篇文章
< 1 2 13 >
每页显示 20 50 100
Structural Glass Fiber Reinforced Concrete for Slabs on Ground
1
作者 Philipp Lober Klaus Holschemacher 《World Journal of Engineering and Technology》 2014年第3期48-54,共7页
This paper aims to contribute to the classification and specification of glass fiber reinforced concrete (GFRC) and to deal with the question if structural glass fiber reinforced concrete as a special kind of glass fi... This paper aims to contribute to the classification and specification of glass fiber reinforced concrete (GFRC) and to deal with the question if structural glass fiber reinforced concrete as a special kind of glass fiber reinforced concrete is suited for use in load-bearing members. Despite excellent material properties, the use of glass fibers in a concrete matrix is carried out so far only in non- structural elements or as a modification for the prevention of shrinkage cracks. The aim of re- search at the University of Applied Sciences in Leipzig is the use of alkali-resistant macro glass fibers as concrete reinforcement in structural elements as an alternative to steel fiber reinforcement. Slabs on ground, as an example for structural members, provide a sensible application for the new material because they can be casted as load bearing and non-load bearing and are mostly made of steel fiber reinforced concrete. In the future, structural glass fiber reinforced concrete shall provide a simple and visually appealing alternative to conventional steel bar or steel fiber reinforced concrete. The glass fibers can also be used in combination with conventional reinforcing bars or mat reinforcements. Initial investigations have announced some potential. 展开更多
关键词 Glass Fiber Reinforced Concrete GFRC Slab on ground Structural Concrete Bending Test
下载PDF
The Research on Grounding Protection for 110kV Resistance Grounding Distribution System 被引量:1
2
作者 Shan Sun Guo Zeng +2 位作者 Xiaozang He Yanping Lv Xinyi Li 《Energy and Power Engineering》 2013年第4期877-880,共4页
Using the neutral grounding method by the resistance in 110?kV system, it can limit the voltage sag and short circuit current when one-phase grounding fault occurred, but it will change the sequence of the network str... Using the neutral grounding method by the resistance in 110?kV system, it can limit the voltage sag and short circuit current when one-phase grounding fault occurred, but it will change the sequence of the network structure and parameters. This paper analyzes the size and distribution of zero sequence voltage and current when one-phase grounding fault occurred in the 110 kV resistance grounding system, and puts forward the grounding protection configuration setting principle of this system combining the power supplying characteristics of 110?kV distribution network. In a reforming substation as an example, the grounding protection of 110 kV lines and transformer have been set and calculated. 展开更多
关键词 NEUTRAL groundING System by Resistance one-phase groundING Fault ZERO SEQUENCE Voltage ZERO SEQUENCE Current PROTECTIon Setting
下载PDF
The Research of Voltage Sag and Power Frequency Overvoltage on 110kV Resistance Grounding System
3
作者 Guo Zeng Guangliang Feng +1 位作者 Yanping Lv Shan Sun 《Energy and Power Engineering》 2013年第4期873-876,共4页
This paper researches the voltage transfer characteristics when one-phase ground fault occurred in the resistance grounding system, by using the theory of the asymmetric variable characteristics and the sequence netwo... This paper researches the voltage transfer characteristics when one-phase ground fault occurred in the resistance grounding system, by using the theory of the asymmetric variable characteristics and the sequence network analysis of the -11 transformer, and concludes the scope of voltage sag and swell and the degree of power frequency overvoltage and their influencing factors in the 110 kV resistance grounding system. Accordingly this paper puts forward the resistance choosing principle: the resistance grounding coefficient must be equal to or greater than 10. So it can not only wipe out the voltage sag and voltage swell but also make sure the overvoltage is limited to electrical equipment allowing range. The method mentioned above is verified by simulation results of a 110 kV power system in ATP. 展开更多
关键词 NEUTRAL groundING System by RESISTANCE one-phase groundING FAULT Power Frequency OVERVOLTAGE
下载PDF
Far-field analysis of effects of unilateral rupturing fault on the space correlation of strong ground motion
4
作者 金星 陈超 +1 位作者 张明宇 高孟潭 《Acta Seismologica Sinica(English Edition)》 EI CSCD 2000年第5期544-551,共8页
On the assumption that seismic source is simplified as linear rupture fault with finite length, this paper qualitatively studies the seismic source effects on space correlation of strong ground motion. Based on expand... On the assumption that seismic source is simplified as linear rupture fault with finite length, this paper qualitatively studies the seismic source effects on space correlation of strong ground motion. Based on expanding expression of Fourier spectrum of strong ground motion with space coordinate variables, this paper also gives a expression of describing correlation of strong ground motion field. According to far-field condition, the theoretical formula of the expression can be obtained. Furthermore, this paper presents a theoretical formula of estimation the radius of strong ground motion field, which depends on expansion condition of Fourier spectrum of strong ground motion, with space variables. At last, taking one earthquake as an example, this paper gives three-dimension patterns of radius of the field with epicenter distance and azimuth as well as frequency. 展开更多
关键词 one-direction rupture fault strong ground motion SPACE correlation FAR-FIELD
下载PDF
Ground-State Energy and Entropy for One-Dimensional Heisenberg Chain with Alternating D-Term
5
作者 Chunhuan Xiang Honglei Wang 《Journal of Applied Mathematics and Physics》 2019年第5期1220-1225,共6页
We study the ground-state information of one-dimensional Heisenberg chain with alternating D-term. Given the ground-state phase diagram, the ground-state energy and the entanglement entropy are obtained by tensor-net ... We study the ground-state information of one-dimensional Heisenberg chain with alternating D-term. Given the ground-state phase diagram, the ground-state energy and the entanglement entropy are obtained by tensor-net work algorithm. The phase transition points are shown in the entanglement entropy figure. The results are agreed with the phase diagram. 展开更多
关键词 ground-STATE Energy ENTROPY onE-DIMENSIonAL HEISENBERG Chain
下载PDF
Triple One Wire System without Grounding
6
作者 Michael Bank Vladimir Tsingaouz 《Engineering(科研)》 2023年第12期867-870,共4页
Today the entire globe is shrouded in an inefficient three-phase system. There is however an efficient single-wire system. To use the single wire method, three phase systems can be converted to triple one wire systems.
关键词 Three-Phase one-Wire System ZEROING groundING Nullifier
下载PDF
Theoretical Studies on the First Hyperpolarizabilities of One-dimensional Donor-bridge-acceptor Chromophores
7
作者 廖荣宝 刘彩萍 +3 位作者 洒荣建 李福君 和建刚 吴克琛 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 北大核心 2008年第6期724-732,共9页
The ground-state dipole moments and second-order nonlinear optical (NLO) properties of a series of one-dimensional (1D) chromophores with donor-bridge-acceptor (D-B-A) structures have been investigated by using ... The ground-state dipole moments and second-order nonlinear optical (NLO) properties of a series of one-dimensional (1D) chromophores with donor-bridge-acceptor (D-B-A) structures have been investigated by using the second-order MФller-Plesset (MP2) and density functional theory (DFT) methods with the basis set of 6-31+G(d). According to the calculated results, the relationship between the molecular static first hyperpolarizability (βμ) and the directions of electron transition has been summarized. In terms of the sign of βμ, these 1D organic chromophores were classified into two categories: type Ⅰ with negative βμ and type Ⅱ bearing positive βμ. The analyses show that the remarkable difference of the first hyperpolarizabilities between Ⅰ and Ⅱ chromophores is associated mainly with the electrostatic interaction between terminal groups and the transport electrons in excited states. Moreover, different from the popular viewpoint, the obtained results also show that most of this series of 1D D-B-A molecules are more charge-separated in the ground states than in the excited states. As a whole, this theoretical investigation, to some extent, can be considered as a useful reference in designing the NLO chromophores with large first hyperpolarizabilities. 展开更多
关键词 one-dimensional donor-bridge-acceptor chromophores ground-state dipole moment static first hyperpolarizability electrostatic interaction
下载PDF
Theoretical Studies on the First Hyperpolarizabilities of One-dimensional Donor-bridge-acceptor Chromophores and New Applications of BLA in Determining Molecular First Hyperpolarizabilities
8
作者 廖荣宝 刘彩萍 +3 位作者 洒荣建 李福君 和建刚 吴克琛 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 北大核心 2008年第7期812-818,共7页
We present a quantum-chemical analysis of the relationship between the bond length alteration (BLA) and the static first hyperpolarizability of a series of one-dimensional (1D) chromophores with donor-bridge-accep... We present a quantum-chemical analysis of the relationship between the bond length alteration (BLA) and the static first hyperpolarizability of a series of one-dimensional (1D) chromophores with donor-bridge-acceptor (D-B-A) structures. The calculated results show that the parameter BLA can be considered as an indicator to evaluate the molecular first hyper- polarizability. Along the direction of molecular ground-state dipole moments, the evolutions of BLA can be classified into three categories: the first is a non-monotonic line, which represents most chromophores; the second is monotonic increasing; and the third, contrarily, is monotonic decreasing. On the whole, the first hyperpolarizabilities of these studied chromophores are the monotonic functions of BLA along the direction of dipole moments. Therefore, the first hyperpolarizability of these 1D chromophores can be preliminarily evaluated in terms of the development of BLA without a rigorous computation. In other words, one can roughly estimate the relative magnitude of the first hyperpolarizability according to the optimized geometry. 展开更多
关键词 one-dimensional donor-bridge-acceptor chromophores ground-state dipole moment static first hyperpolarizability bond length alteration
下载PDF
“一村一名大学生计划”对农村创业成功的影响研究 被引量:1
9
作者 佘镜怀 张祺 孙鹤 《开放学习研究》 2024年第2期1-10,共10页
兴大业,必先用人。人才振兴是推进乡村振兴的重要引擎力量。本文基于教育部“一村一名大学生计划”评选出的69个案例,运用扎根理论,通过开放式编码、主轴式编码以及选择式编码,分析出“一村一名大学生计划”对农村创业成功的核心影响因... 兴大业,必先用人。人才振兴是推进乡村振兴的重要引擎力量。本文基于教育部“一村一名大学生计划”评选出的69个案例,运用扎根理论,通过开放式编码、主轴式编码以及选择式编码,分析出“一村一名大学生计划”对农村创业成功的核心影响因素,并结合社会资本理论与自我效能理论,探究了“一村一名大学生计划”实现农村创业成功的路径。结果发现:“一村一名大学生计划”的开展,具有增加农村创业者社会资本和专业知识、提高创业者个人能力的功能,从而帮助农村创业者有效地识别创业机会,获取更优质的创业资源,做出科学正确的创业行为,最终实现创业成功。同时,基于所得结果,归纳、构建出“一村一名大学生计划”影响农村创业成功的机理模型,据此提出未来助力“乡村振兴”的相关建议。 展开更多
关键词 乡村振兴 一村一名大学生计划 农村创业成功 扎根理论
下载PDF
基于一维变分法的微波辐射计反演边界层温湿廓线 被引量:1
10
作者 黄威 李宛桐 +3 位作者 胡帅 脱宇峰 鱼艇 倪祥龙 《地球物理学报》 SCIE EI CAS CSCD 北大核心 2024年第5期1699-1708,共10页
地基微波辐射计能够克服星载遥感对低层大气不敏感的缺点,在边界层大气探测方面更具优势.一维变分反演算法考虑了辐射传输过程等物理机制,在应用于微波辐射计的反演时具有很高的可信度.针对微波辐射计信息含量较低以及一维变分算法收敛... 地基微波辐射计能够克服星载遥感对低层大气不敏感的缺点,在边界层大气探测方面更具优势.一维变分反演算法考虑了辐射传输过程等物理机制,在应用于微波辐射计的反演时具有很高的可信度.针对微波辐射计信息含量较低以及一维变分算法收敛率不高等问题,提出利用地面气象要素改进算法在近地面层的反演精度和引入正则化算子提升算法的收敛特性.利用探空数据对上述改进方法的提升效果进行验证,结果表明:地面气象要素的引入使得反演算法在地表温湿度的均方根误差分别降低了78.2%和55.5%,对于上层大气温湿廓线也有小幅提升;正则化算子对算法的反演时间和反演精度影响很小,但是可以显著地减少未收敛样本个数和提升反演廓线的质量. 展开更多
关键词 一维变分 温湿廓线 微波辐射计 正则化算子
下载PDF
快速动态响应同步调相机转子引线断裂故障分析
11
作者 王庆 郭贤珊 +5 位作者 黄金军 刘超 李明 韩晋思 李斯特 曹志伟 《电网技术》 EI CSCD 北大核心 2024年第9期3957-3964,共8页
大型调相机的安全稳定运行关乎着电网电压的稳定、动态无功支撑水平和新能源消纳能力。该文研究了一起实际的调相机转子引线断裂故障,综合现场检查、返厂解体检查、试验分析、故障复现实验及其他换流站同型号调相机的检查结果,发现转子... 大型调相机的安全稳定运行关乎着电网电压的稳定、动态无功支撑水平和新能源消纳能力。该文研究了一起实际的调相机转子引线断裂故障,综合现场检查、返厂解体检查、试验分析、故障复现实验及其他换流站同型号调相机的检查结果,发现转子引线的设计及工艺方面存在缺陷,径向存在约4mm的悬空区域,加之长期运行磨损,最终导致调相机引线断裂烧熔触发跳机。从引线设计方案优化和实际运行工况着手,充分研判该型号调相机转子引线各段结构的可靠性及适用性,深入研究各种工况下的离心力及振动,保证引线及配套绝缘紧固连接,论证得出治理方案,为在运工程及后续新建机组安全可靠性奠定基础。 展开更多
关键词 同步调相机 转子引线断裂 一点接地
下载PDF
基于阻尼特性分析的跳闸回路抗一点接地误动防护
12
作者 李端姣 颜大涵 刘建明 《南方电网技术》 CSCD 北大核心 2024年第8期99-105,共7页
受跳闸线圈、继电器的电阻及电感与直流系统对地电容影响,变电站断路器跳闸回路在发生一点接地后构成RLC二阶电路,一点接地电流的振荡可能导致线圈或继电器误动并引发断路器跳闸。剖析了跳闸回路的组成与发生一点接地的风险,分析了跳闸... 受跳闸线圈、继电器的电阻及电感与直流系统对地电容影响,变电站断路器跳闸回路在发生一点接地后构成RLC二阶电路,一点接地电流的振荡可能导致线圈或继电器误动并引发断路器跳闸。剖析了跳闸回路的组成与发生一点接地的风险,分析了跳闸回路电阻、电容、电感在常规取值范围内对接地电流的影响,并通过粒子群算法优化、多维度变量分析等方法提出了跳闸回路的电阻、电容、电感在保证一点接地不误动情况下的取值范围。论证了进一步规范继电器电阻及电感值、优化继电器动作电流、管控直流系统等效对地电容的必要性,为变电站设备元件选型与直流系统对地电容常态化管控提供了指导参考。 展开更多
关键词 跳闸回路 RLC二阶电路 一点接地 粒子群优化 继电器
下载PDF
工业园区零碳化发展的现实困境与模式创新——基于井冈山工业园区的调查研究
13
作者 温湖炜 田素滇 施嘉仪 《老区建设》 2024年第6期85-96,共12页
园区是产业和企业的规模化聚集载体,工业园区低碳化发展则是双碳目标实现的必然选择。基于在井冈山工业园区实地调查和深度访谈资料,考察井冈山工业园区零碳化发展的现实困境与路径选择。研究结果表明,工业园区零碳化建设存在顶层设计... 园区是产业和企业的规模化聚集载体,工业园区低碳化发展则是双碳目标实现的必然选择。基于在井冈山工业园区实地调查和深度访谈资料,考察井冈山工业园区零碳化发展的现实困境与路径选择。研究结果表明,工业园区零碳化建设存在顶层设计集成化不足、数智化基础支撑不强、低碳发展技术人才不多、经济发展与碳约束平衡难等挑战。基于此,应建立“统协转监”四维框架,并采用“政府主导”的多主体协作开发模式,以促进工业园区零碳化发展。 展开更多
关键词 双碳目标 工业园区 扎根理论 “一核双轨”模式 零碳园区
下载PDF
新疆生产建设兵团地下水异构数据集成与建库
14
作者 毛国新 张可文 孙蓬勃 《测绘与空间地理信息》 2024年第10期100-103,共4页
新疆生产建设兵团(以下简称“兵团”)建设的地下水井电双控工程,运行数据分别存储在各师自建的数据库中,不利于兵团统一监管,迫切需要加快地下水异构数据集成与监管分析。开展兵团地下水机井资源数据整合,主要基于兵团水利一张图综合信... 新疆生产建设兵团(以下简称“兵团”)建设的地下水井电双控工程,运行数据分别存储在各师自建的数据库中,不利于兵团统一监管,迫切需要加快地下水异构数据集成与监管分析。开展兵团地下水机井资源数据整合,主要基于兵团水利一张图综合信息系统,以springboot为系统框架,采用WebGIS的异构系统集成整合,实现机井“一数一源”体系建设,建成统一共享的地下水数据管理中心,有效提升兵团地下水资源监管能力。 展开更多
关键词 地下水 异构数据集成 一数一源 数据共享
下载PDF
城市轨道交通专用轨回流系统保护设计分析
15
作者 贾国兴 《智能建筑电气技术》 2024年第2期21-24,共4页
随着《城市轨道交通工程项目规范》GB55033-2022的实施,将杂散电流防护设计提到了新的高度,并提高了杂散电流的泄漏标准,专用轨回流系统将是轨道交通工程杂散电流防护设计的有效解决方案。本文以宁波轨道交通项目设计为例,对专用轨回流... 随着《城市轨道交通工程项目规范》GB55033-2022的实施,将杂散电流防护设计提到了新的高度,并提高了杂散电流的泄漏标准,专用轨回流系统将是轨道交通工程杂散电流防护设计的有效解决方案。本文以宁波轨道交通项目设计为例,对专用轨回流系统的保护设置进行分析,本方案特有的保护设施包括专用轨接地装置和地负单向导通装置,提出将专用轨接地装置与地负单向导通装置合并设置建议。 展开更多
关键词 轨道交通 专用轨接地装置 地负单向导通装置 合并设置
下载PDF
《礼记·玉藻》“君赐车马”章辨诂
16
作者 马金亮 于少飞 《鲁东大学学报(哲学社会科学版)》 2024年第2期29-36,共8页
学界关于《礼记·玉藻》“君赐车马”句的读法、释义主要有两种观点。一种以郑玄为代表,认为“拜”“赐”二字当分读,后一句言卿大夫受赐于天子,归必致于其君,待君有命才能使用;另一种以陆佃为代表,认为“拜”“赐”当合读,后一句... 学界关于《礼记·玉藻》“君赐车马”句的读法、释义主要有两种观点。一种以郑玄为代表,认为“拜”“赐”二字当分读,后一句言卿大夫受赐于天子,归必致于其君,待君有命才能使用;另一种以陆佃为代表,认为“拜”“赐”当合读,后一句承接前一句,言没有国君之命则不敢乘服。经考辨,这两句是统言“三赐”之礼,陆氏的读法更符合经文语境,但他对第二句的释义不甚清晰,应释为:若没有得到国君的正式授命,则不可以立即乘服。关于“据掌致诸地”,多数学者认为是解释“稽首”之仪,但实属赘述;段玉裁等人认为是臣受君面赐所行之礼。经考察,臣受君面赐确实应先稽首然后受所赐之物,则“据掌致诸地”应释为:臣稽首而后双手捧所赐之物于地上。 展开更多
关键词 《礼记·玉藻》 君赐车马 君未有命 据掌致诸地
下载PDF
单相接地故障全电流补偿的研究 被引量:16
17
作者 唐轶 陈奎 +1 位作者 陈庆 方水丽 《中国矿业大学学报》 EI CAS CSCD 北大核心 2003年第5期558-562,共5页
减小接地故障点的残流有利于接地电弧的瞬间熄灭及降低间歇性电弧接地过电压.单相接地故障全电流补偿的含意是:补偿器不仅补偿电网分布电容的无功电流,还补偿电网零序回路的有功电流,使接地故障点的残流趋于零。本文提出了三种单相接地... 减小接地故障点的残流有利于接地电弧的瞬间熄灭及降低间歇性电弧接地过电压.单相接地故障全电流补偿的含意是:补偿器不仅补偿电网分布电容的无功电流,还补偿电网零序回路的有功电流,使接地故障点的残流趋于零。本文提出了三种单相接地全电流补偿方式:中性点电阻接地超前相接电感;中性点电抗接地滞后相接电容;中性点电抗接地超前相接电感.本文还给出了各全电流补偿方式的全电流补偿条件,分析了各全电流补偿方式因调整误差对接地点残流大小的影响. 展开更多
关键词 配电网 中性点接地 单相接地故障 全电流补偿
下载PDF
光纤复合架空地线直流融冰绝缘化改造对地线绝缘子与并联放电间隙的电气要求 被引量:9
18
作者 陈秀娟 夏潮 +3 位作者 朱海宇 马振国 殷禹 张晔 《高电压技术》 EI CAS CSCD 北大核心 2017年第8期2733-2738,共6页
为满足光纤复合架空地线(OPGW)直流融冰的需要,同时解决环流损耗和易遭雷击断股等问题,须将OPGW接地方式由目前常用的逐塔接地改造为分段或全线绝缘、单点接地方式;OPGW经地线绝缘子及其并联放电间隙与杆塔相连。为此,提出了OPGW直流融... 为满足光纤复合架空地线(OPGW)直流融冰的需要,同时解决环流损耗和易遭雷击断股等问题,须将OPGW接地方式由目前常用的逐塔接地改造为分段或全线绝缘、单点接地方式;OPGW经地线绝缘子及其并联放电间隙与杆塔相连。为此,提出了OPGW直流融冰绝缘化改造对并联放电间隙的电气要求,分别对正常运行时、地线直流融冰条件下和雷击情况下的并联放电间隙电气性能进行了详细的计算分析和试验研究。结果表明:并联放电间隙距离选择应满足感应电压和直流融冰电压的耐受要求,还应保证并联放电间隙在雷电过电压下可靠击穿;要满足工频感应电压的耐受要求,间隙距离可取20~100 mm;要满足直流融冰电压为-20 k V×(1±10%)的耐受要求,间隙距离应大于60 mm;考虑到间隙放电的分散性,间隙距离宜适当增大,推荐值为70~80 mm;70~80 mm间隙距离的雷电冲击放电电压一般不大于100 k V,线路遭受雷击时,地线绝缘子与并联放电间隙所承受的电压至少为885 k V,甚至高达数MV,并联放电间隙能可靠击穿,从而确保地线绝缘子的运行安全性。该研究结果可为OPGW直流融冰绝缘化改造提供理论支撑和数据支持。 展开更多
关键词 OPGW 光纤复合架空地线 逐塔接地 单点接地 地线绝缘子 并联放电间隙 直流融冰 绝缘化改造
下载PDF
强杂波下含旋转部件的目标成像及微多普勒提取 被引量:13
19
作者 罗迎 张群 +1 位作者 封同安 金亚秋 《系统工程与电子技术》 EI CSCD 北大核心 2009年第2期261-264,共4页
目标结构中的旋转部件引起的雷达回波信号的附加频率调制称为微多普勒现象,其反映了目标独一无二的结构特征,同时也给目标主体的成像带来了污染。提出了一种强地杂波背景下含旋转部件目标成像及微多普勒信号提取的方法。在对目标回波解... 目标结构中的旋转部件引起的雷达回波信号的附加频率调制称为微多普勒现象,其反映了目标独一无二的结构特征,同时也给目标主体的成像带来了污染。提出了一种强地杂波背景下含旋转部件目标成像及微多普勒信号提取的方法。在对目标回波解线调时,采用一次相消技术剔除地杂波,获得清晰的目标谱图;再对谱图进行处理,分离目标主体信息和微多普勒信息,实现目标主体的清晰成像;对微多普勒信息进行分析还可以获取目标的一些微动特征。最后的仿真实验验证了该方法的有效性。 展开更多
关键词 雷达成像 微多普勒 一次相消 地杂波
下载PDF
西门子7U系列微机保护装置的原理分析及在发变组保护中的应用 被引量:6
20
作者 丁网林 骆健 《电网技术》 EI CSCD 北大核心 2001年第6期41-43,51,共4页
介绍了西门子 7U微机发电机—变压器组保护装置的基本功能 ,对西门子 7U发变组保护的原理 :差动保护 ,失磁保护 ,定子一点接地和转子一点接地保护进行了分析。并对大型发变组保护提出了 7U的配置方案。
关键词 微机保护装置 发电机组 变压器组 TU系列 差动保护 继电保护 西门子
下载PDF
上一页 1 2 13 下一页 到第