On-line current feed and computer aided control tactics for automatic balancing head
1
作者 李勇 陆永平 +1 位作者 须根发 夏松波 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2002年第2期205-207,共3页
In the designed automatic balancing head, a non contact induction transformer is used to deliver driving energy to solve the problem of current fed and controlling on line. Computer controlled automatic balancing expe... In the designed automatic balancing head, a non contact induction transformer is used to deliver driving energy to solve the problem of current fed and controlling on line. Computer controlled automatic balancing experiments with phase magnitude control tactics were performed on a flexible rotor system. Results of the experiments prove that the energy feeding method and the control tactics are effective in the automatic balancing head for vibration controlling. 展开更多
关键词 automatic balancing balancing HEAD on-line CONTROL TACTICS
下载PDF
Reagent optimization for on-line simultaneous polarographic determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of anextremely large excess of Zn^(2+) 被引量:4
2
作者 WANG Guo-wei YANG Chun-hua +2 位作者 ZHU Hong-qiu LI Yong-gang GUI Wei-hua 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第9期2199-2204,共6页
Reagents are optimized for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in zinc sulfate solution, which contains an extremely large excess of Zn^(2+). First, the reagents and their d... Reagents are optimized for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in zinc sulfate solution, which contains an extremely large excess of Zn^(2+). First, the reagents and their doses for the experiment are selected according to the characteristics of the zinc sulfate solution. Then, the reagent doses are optimized by analyzing the influence of reagent dose on the polarographic parameters(i.e. half-wave potential E_(1/2) and limiting diffusion current I_p). Finally, the optimization results are verified by simultaneously determining trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+). The determination results indicate that the optimized reagents exhibit wide linearity, low detection limits, high accuracy and good precision for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+). 展开更多
关键词 on-line simultaneous determination trace polymetallic ions reagent optimization high concentration ratio
下载PDF
Flow-Injection Microcolumn on-Line Preconcentration for theDetermination of Chromium(Ⅵ) 被引量:1
3
作者 Ma Wanhong Cat Ruxiu Lin Zhixin(College of Chemistry, Wuhan University. Wuhan 430072, China) 《Wuhan University Journal of Natural Sciences》 CAS 1998年第4期464-468,共5页
A rapid and sensitive on-line preconcentration method for spectrophotometric determination of chromium (VI) in nature water is described. Preconcentration and determination are based on (i) the quantitative and fast a... A rapid and sensitive on-line preconcentration method for spectrophotometric determination of chromium (VI) in nature water is described. Preconcentration and determination are based on (i) the quantitative and fast adsorption of chromium (VI) on the high surface area nanometer-size TiO2 (anatase) powders, which prepared by a sol-gel method from hydrolysis of TiCI4 and (ii) the quantitative and reproducible elution of Cr (VI) by 2. 0 mol. L-1 HCI. A mini-column system for preconcentration is developed, Cr(VI)on the mini-column is eluted and merged with a stream water and DPCB (1, 5-diphenylcarbazide ) as the chromogenic reagent. The Proposed system permits throughputs of 6 sample h--l (0. 001 μg mL-1 Cr(VI) ) or 20 sample h-1 (0. 1 μg mL-1Cr (VI) . The preconcentration factor is 55. The detection limit is 0. 8 ng·mL-1 Cr(VI). The reproducibility is satisfactory with a relative standard deviation of less than 3. 35% (0. Of μg'mL-1Cr (VI), n = 5). 展开更多
关键词 anometer-size TiO2 Cr (Ⅵ) determination on-line preconcentration flow-injection spectrophotometric detection
下载PDF
ON-LINE ELECTROLYTIC DISSOLUTION OF SOLID METAL SAMPLE AND DETERMINATION OF COPPER IN ALLOY BY AAS
4
作者 Dong Xiang YUAN Peng Yuan YANG Xiao Ru WANG Ben LI HUANG Department of Chemistry,Xiamen University,Xiamen,361005 《Chinese Chemical Letters》 SCIE CAS CSCD 1990年第3期235-236,共2页
On-line dissolution of solid metal sample can be carried out by electrolysis under the control of flow injection analyzer(FIA),and the dissolved sample can be transferred to atomic spectrometer for the direct analysis... On-line dissolution of solid metal sample can be carried out by electrolysis under the control of flow injection analyzer(FIA),and the dissolved sample can be transferred to atomic spectrometer for the direct analysis.The hyphenated technique of FIA on-line electrolytic dissolution of alloy and atomic absorption spectrometer(AAS)detection is developed.The research is focused on the effects of electrolyte composition and electrolysis parameters on the sample dissolving,as well as the quantitative analysis of Cu in Al alloy samples. 展开更多
关键词 on-line ELECTROLYTIC DISSOLUTION OF SOLID METAL SAMPLE AND determinATION OF COPPER IN ALLOY BY AAS line ICP LINE
下载PDF
Method for Automatically Determining the Importance of Criteria in Multicriteria Decision-Making Problems
5
作者 Gennady Ivanovich PerminovI Leonova Nina Vjacheslavna 《Management Studies》 2014年第3期191-201,共11页
Multicriteria group decision-making problems (DMP) require criteria weights. Assigning weights of importance of the criteria Face Decision-maker (DM) means, in essence, a priori purpose variant of the winner. Ther... Multicriteria group decision-making problems (DMP) require criteria weights. Assigning weights of importance of the criteria Face Decision-maker (DM) means, in essence, a priori purpose variant of the winner. There are a number of problematic situations involving a large number of criteria: (1) problems where the evaluation of alternatives represent the degree of satisfaction of basic performance requirements object bidders. Matrix estimates with different low variability and a very large number of requirements (criteria); (2) the use of cognitive maps for modeling problem situations. If the alternatives are considered not only divisible strategy (options impact on concepts), matrix estimates accepts small size. If the task is allowed to use an alternative strategy mixtures fraction (e.g., 25% influences on the concept 1, 50% influences on the concept 2, 10% influences on the concept 3, etc.), the matrix ratings also gaining greater dimension. It is clear that in such cases the appointment criteria weights DMP becomes a problem. 展开更多
关键词 MULTICRITERIA DECISION making automatic determination of the WEIGHTS of the CRITERIA
下载PDF
DETERMINATION OF ANTIMONY IN WATER SAMPLES BY FLOW-INJECTION HYDRIDE GENERATION ATOMIC ABSORPTION SPECTROMETRY WITH ON-LINE ION-EXCHANGE COLUMN PRECONCENTRATION
6
作者 Shu Kun XU and Zhao Lun FANG Institute of Applied Ecology, Academia Sinica, Shenyang, 110015 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第11期915-918,共4页
On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(... On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(Ⅲ) was preconcentrated on a micro-column packed with CPG-8Q chelating ion-exchanger using time-based sample loading and eluted by 4 mol l^(-1) HCl directly into the hydride generation AAS system. A detection limit (3σ) of 0.0015μg l^(-1) Sb(Ⅲ) was obtained on the basis of a 20 fold enrichment and with a sampling frequency of 60h^(-1). The precision was 1.0% r.s.d.(n=11) at the 0.5μg l^(-1) Sb(Ⅲ) level. Recoveries for the analysis of antimony in tap water, snow water and sea water samples were in the range 97-102%. 展开更多
关键词 Zhang determinATION OF ANTIMONY IN WATER SAMPLES BY FLOW-INJECTION HYDRIDE GENERATION ATOMIC ABSORPTION SPECTROMETRY WITH on-line ION-EXCHANGE COLUMN PRECONCENTRATION SQ CPG ION LINE
下载PDF
Discuss of Key Issue for Automatic BATS Control in Regional Power Grid
7
作者 Kaiyan Pan Yingying Sun Zhenyan Gao 《Energy and Power Engineering》 2017年第4期189-197,共9页
Busbar Automatic Transfer Switch (BATS) is very important for power distribution reliability. However, BATS can’t consider whether it cause overloading of devices after it acts. In this paper, we introduce the design... Busbar Automatic Transfer Switch (BATS) is very important for power distribution reliability. However, BATS can’t consider whether it cause overloading of devices after it acts. In this paper, we introduce the design principle of Automatic BATS control from whole architecture including its function, strategy and a rule of on-off. On the other hand, the running experience and effect is also introduced. Site operation shows that the proposed method is feasible and it can ensure power grid reliability. 展开更多
关键词 BUSBAR automatic Transfer SWITCH (BATS) N Minus One on-line Controlling Automaitc BATS CONTROL
下载PDF
Automatic System for Failure Detection in Hydro-Power Generators
8
作者 Luis Carlos Ribeiro Levy Ely de Lacerda de Oliveira +4 位作者 Erik Leandro Bonaldi Luiz Eduardo Borges da Silva Camila Paes Salomon Jonas G. Borges da Silva Germano Lambert-Torres 《Journal of Power and Energy Engineering》 2014年第4期36-46,共11页
This paper presents an automatic system for failure detection in hydro-power generators. The main idea of this system is to detect failure using current and voltage signals acquired without any type of internal interf... This paper presents an automatic system for failure detection in hydro-power generators. The main idea of this system is to detect failure using current and voltage signals acquired without any type of internal interference in the generator operation. The detected failures could be mechanical or electrical origins, such as: problems in bearings, unwanted vibrations, partial discharges, misalignment, unbalancing, among others. It is possible because the generator acts as a transducer for mechanical problems, and they appear in current and voltage signals. This automatic system based on electric signature analysis has been installed in Itapebi Power Plant generators since 2012. Some results are presented in this paper. 展开更多
关键词 automatic System on-line Measurements Digital Signal Processing PREDICTIVE Maintenance FAILURE Detection
下载PDF
基于卷积神经网络算法判定稀土总量滴定终点技术研究
9
作者 吴永明 陈思琦 陈吉文 《中国无机分析化学》 CAS 北大核心 2024年第5期567-574,共8页
由于稀土产业发展迅速,市场需求越来越大,应用范围越来越广,需建立一个长期有效且适用于测定各类稀土的方法。针对目前传统稀土总量检测方法效率低、准确度低、滴定终点差异大等问题,难以满足在线检测的需要。卷积神经网络算法通过摄像... 由于稀土产业发展迅速,市场需求越来越大,应用范围越来越广,需建立一个长期有效且适用于测定各类稀土的方法。针对目前传统稀土总量检测方法效率低、准确度低、滴定终点差异大等问题,难以满足在线检测的需要。卷积神经网络算法通过摄像头记录样品在滴定过程中溶液的颜色变化,对溶液进行图像特征提取和学习,从而有效、准确地实现化学反应过程中溶液颜色的自动化识别,配合步进电机和注射泵等部件实现自动滴定过程,建立了一种基于卷积神经网络的稀土总量浓度在线分析方法。图像识别本质上是对图像信息进行特征提取,而卷积神经网络(CNN)有着传统识别方法不具备的优点,比如能够自行训练、识别速度更快、所需特征更少等,将自动滴定与神经网络相结合,实现了滴定流程的自动化和样品前处理、滴定、终点判定等过程的一体化,且设备内可同时进行五个样品滴定,提高了滴定效率。 展开更多
关键词 卷积神经网络 自动滴定 稀土总量 终点判定
下载PDF
自动化阴道分泌物分析系统复检规则的建立与验证专家共识
10
作者 中国老年保健医学研究会检验医学分会 上海市优生优育科学协会(上海市妇幼保健协会)检验医学专委会 +4 位作者 丛玉隆 唐振华 陆庭嫣 王萍 陈晓军 《检验医学》 CAS 2024年第5期415-422,共8页
阴道分泌物显微镜检查(镜检)是妇产科检查的常规项目,随着检验技术自动化的发展,基于不同检测原理的自动化阴道分泌物分析仪器被开发应用,以满足临床大样本量、高效、标准化的需求。目前,湿片/革兰染色镜检仍然是诊断女性常见生殖道感... 阴道分泌物显微镜检查(镜检)是妇产科检查的常规项目,随着检验技术自动化的发展,基于不同检测原理的自动化阴道分泌物分析仪器被开发应用,以满足临床大样本量、高效、标准化的需求。目前,湿片/革兰染色镜检仍然是诊断女性常见生殖道感染性疾病的金标准,是自动化仪器检测结果准确性评估的参考方法。当前的质量文件尚缺乏对体液范畴内阴道分泌物自动化检测复检规则的统一要求和细则指导,中国老年保健医学研究会检验医学分会和上海市优生优育科学协会(上海市妇幼保健协会)检验医学专委会基于中国国家标准、行业标准、质量体系要求和国内外相关指南、文献,在自动化阴道分泌物分析系统复检规则的建立、验证、规则应用等方面形成共识,共同制定《自动化阴道分泌物分析系统复检规则的建立与验证专家共识》,以期能更好地规范自动化阴道分泌物分析系统复检规则的建立,保证检验结果的准确性。 展开更多
关键词 阴道分泌物 自动化检测 显微镜检查 复检规则 专家共识
下载PDF
全自动流动注射分光光度法测定锰厂排放水中的总氮
11
作者 石金雨 董黎 +1 位作者 刘晓芳 黎国兰 《绵阳师范学院学报》 2024年第5期53-57,共5页
探讨了全自动流动注射分光光度法测定锰厂排放水质总氮含量的方法.在0~6.000 mg·L^(-1)浓度范围内呈线性关系,其回归方程为y=134.86x+116.7,相关系数R达到1.000 0,方法检出限为0.006 7 mg·L^(-1),加标回收率在98.6%~109%之间... 探讨了全自动流动注射分光光度法测定锰厂排放水质总氮含量的方法.在0~6.000 mg·L^(-1)浓度范围内呈线性关系,其回归方程为y=134.86x+116.7,相关系数R达到1.000 0,方法检出限为0.006 7 mg·L^(-1),加标回收率在98.6%~109%之间,实验结果表明线性关系良好,方法准确可靠.并采用全自动流动注射分光光度法和碱性过硫酸钾消解-紫外分光光度法对质控样品进行了对比测试,两种方法测定结果无显著差异,测定值均在标准值范围内.该法应用于电解锰厂排放废水水质总氮测定,具有操作简单、测试快速、准确度高、精密度好、检出限低的优点,能快速完成大批量样品测定. 展开更多
关键词 全自动流动注射 测定 总氮
下载PDF
基于一维和三维CFD方法的四级径流式鼓风机扩压器和回流器设计与优化
12
作者 Vlad Goldenberg Leonid Moroz +2 位作者 Ti-shun Zhang Shigeyuki Tomimatsu Masatoshi Tomita 《风机技术》 2024年第3期47-59,共13页
Soft In Way Inc. performed the aerodynamic design of a 4 stages high pressure radial blower with vaneless diffusers and deswirlers for DMW Corporation in 2021. The nominal pressure ratio of the machine is near 2.Such ... Soft In Way Inc. performed the aerodynamic design of a 4 stages high pressure radial blower with vaneless diffusers and deswirlers for DMW Corporation in 2021. The nominal pressure ratio of the machine is near 2.Such a pressure ratio often characterizes what would typically be called a compressor, especially if the compression work is performed in one stage. For the subject machine of the present study, the compression work is split into 4 stages.This paper describes the design procedure for this blower, initially focusing in depth on the tradeoffs between work split,rotor diameter, and rotor vane back-sweep angle. The paper then presents a further design and optimization work of different variants of diffuser and deswirler based on aerodynamic performance for this 4 stages radial blower. The number of deswirler blades in the return channel was reduced from 19 to 10 in consideration of manufacturing requirements. To minimize losses in performance due to reduced blade number, several candidates of varied geometry shape deswirler blades were obtained from an automatic design and optimization workflow combining with 3D CFD calculation. All candidates of deswirler were implemented to the entire 4 stages radial blower to analyze machine performance by 3D CFD calculation and the best 10-blade deswirler geometry was determined. 3D CFD analysis shows that 10 blades of deswirler is unable to provide the same pressure rise and efficiency as the original design with 19 blades when all other parts of the design, such as rotor and diffuser are maintained the same. To further improve the blower performance, the similar automatic workflow was applied to study vaned diffuser influence to the blower performance based on the new blower configuration. The number and geometry of best diffuser blades was obtained from the automatic workflow and entire blower performance with vaned diffuser was analyzed and validated by 3D CFD calculation. After finalizing the aerodynamic flow path geometries and configuration of new blower design,performance for new blower and old one are predicted by 1D method with loss model correction and 3D CFD calculation. 1D and 3D CFD calculation results are compared and good agreement is achieved. Though, small discrepancy between them is noticed and reasons are analyzed. Furthermore, 3D CFD calculations with stall determination method based on several stall-indication metrics were performed to determine surge points of the 2 new blower configurations with vaned and vaneless diffuser. A future publication is intended to show the validation of the design with tested performance data. 展开更多
关键词 Radial Blower Blower Design Blower 1D Analysis Deswirler DIFFUSER automatic Optimization 3DCFD Surge determination
下载PDF
基于ARD-AVA反演的含气性预测技术及应用
13
作者 纪永祯 《石油地球物理勘探》 EI CSCD 北大核心 2024年第4期811-818,共8页
为进一步优化AVA反演技术以提高储层含气性预测精度,需要解决反演方法中先验的选择和AVA反演近似式与部分叠加策略的选择两个关键问题。为此,利用自动相关判别(ARD)先验中的超参数从不同地震道估计可变的特定值,而不再用固定值(如高斯... 为进一步优化AVA反演技术以提高储层含气性预测精度,需要解决反演方法中先验的选择和AVA反演近似式与部分叠加策略的选择两个关键问题。为此,利用自动相关判别(ARD)先验中的超参数从不同地震道估计可变的特定值,而不再用固定值(如高斯先验、柯西先验等)约束反演过程,可以在含气性预测时更好地反映储层地质特征的横向变化,获得高精度预测结果;在AVA反演近似式与部分叠加策略的选择时,参考了两个标准(参数灵敏度和条件数),给出反演近似式和最大、最小角度与角度间隔的选择建议。提出的ARD-AVA反演方法和近似式与部分叠加优选策略,在河道类型气藏含气性预测中效果很好。通过与传统方法的预测结果对比,结合测井和生产数据,证明了该方法的可行性和优势。 展开更多
关键词 AVA反演 自动相关判别先验 含气性预测 河道储层
下载PDF
自动电位滴定法测定115%以下多聚磷酸中的磷酸含量
14
作者 李琼梅 党兴旺 +1 位作者 耿威 李祥 《云南化工》 CAS 2024年第9期100-102,共3页
将115%以下的聚磷酸加热水解成正磷酸,用已知浓度的氢氧化钠标准滴定溶液在全自动电位滴定仪上进行滴定,用自动电位滴定仪记录滴定曲线,根据曲线上的2个拐点处所消耗的氢氧化钠标准滴定溶液的体积,计算出聚磷酸中磷酸的含量。该方法与... 将115%以下的聚磷酸加热水解成正磷酸,用已知浓度的氢氧化钠标准滴定溶液在全自动电位滴定仪上进行滴定,用自动电位滴定仪记录滴定曲线,根据曲线上的2个拐点处所消耗的氢氧化钠标准滴定溶液的体积,计算出聚磷酸中磷酸的含量。该方法与重量法相比,具有分析过程简单、快速、准确度高、成本低的优点。 展开更多
关键词 多聚磷酸 自动电位滴定法 磷酸含量 测定
下载PDF
水泥凝结时间自动测定仪检测结果的评价分析
15
作者 单清圳 《广东建材》 2024年第9期131-133,共3页
根据水泥凝结时间现行国家标准标准中的规定,通过比对使用水泥凝结时间自动测定仪和标准方法的检测结果,采用允许误差比较、F检验和t检验等方法,验证两种测试方法是否存在显著差异,并利用能力验证结果进行评价分析自动测定仪能是否得出... 根据水泥凝结时间现行国家标准标准中的规定,通过比对使用水泥凝结时间自动测定仪和标准方法的检测结果,采用允许误差比较、F检验和t检验等方法,验证两种测试方法是否存在显著差异,并利用能力验证结果进行评价分析自动测定仪能是否得出与标准中规定方法相同结果,同时结合实际使用经验提出自动测定仪使用注意事项。 展开更多
关键词 水泥 凝结时间 自动测定仪 检测
下载PDF
凯氏定氮仪法测定腐竹中蛋白质含量的不确定度评定
16
作者 尤加庆 《食品安全导刊》 2024年第16期121-123,127,共4页
运用自动凯氏定氮仪法对腐竹中蛋白质含量进行检测,对检测过程的不确定度进行分析评定,以进一步完善检测过程的质量控制。结果表明,腐竹中蛋白质含量为43.2 g/100 g时,扩展不确定度为1.6 g/100 g(在95%置信区间下,k=2)。由仪器引入的不... 运用自动凯氏定氮仪法对腐竹中蛋白质含量进行检测,对检测过程的不确定度进行分析评定,以进一步完善检测过程的质量控制。结果表明,腐竹中蛋白质含量为43.2 g/100 g时,扩展不确定度为1.6 g/100 g(在95%置信区间下,k=2)。由仪器引入的不确定度和检测过程重复性引入的不确定度对检测不确定度的影响较大。 展开更多
关键词 自动凯氏定氮法 蛋白质 不确定度 腐竹
下载PDF
基于音频特性的牙刷正反面自动识别控制系统设计
17
作者 王吴光 《南通职业大学学报》 2024年第2期77-81,共5页
为有效提升牙刷制作植毛环节正反面识别的准确率与效率,基于牙刷柄(牙刷头)孔面与非孔面(正反面)反馈的音频特性存有差异的原理,设计了一种牙刷正反面自动识别系统。该系统可通过预设判断阈值,经控制程序自动判断牙刷柄的正反面,再采用... 为有效提升牙刷制作植毛环节正反面识别的准确率与效率,基于牙刷柄(牙刷头)孔面与非孔面(正反面)反馈的音频特性存有差异的原理,设计了一种牙刷正反面自动识别系统。该系统可通过预设判断阈值,经控制程序自动判断牙刷柄的正反面,再采用反馈系统控制伺服电机进行相应动作,确保植毛时牙刷头孔面向上放置。实践操作结果表明,该系统稳定性、准确度、使用成本均达预期,且操作方便,值得推广应用。 展开更多
关键词 牙刷制作 自动识别 音频特性 正反面 阈值判断 伺服电机
下载PDF
基于多传感器融合的工作面设备定位定姿技术研究
18
作者 刘超 《煤矿机械》 2024年第4期34-37,共4页
随着科技的发展与进步,煤矿智能化已经成为目前矿业生产中的重点研究方向。但是在薄煤层工作面中由于顶板条件的复杂性以及作业环境的多变性,导致目前的井下自动化控制技术中存在液压支架自动跟机不能完美适应井下顶底板环境且采煤机难... 随着科技的发展与进步,煤矿智能化已经成为目前矿业生产中的重点研究方向。但是在薄煤层工作面中由于顶板条件的复杂性以及作业环境的多变性,导致目前的井下自动化控制技术中存在液压支架自动跟机不能完美适应井下顶底板环境且采煤机难以精准定位的问题。以薄煤层工作面自动化控制系统为基础,结合图像识别以及多传感器融合的方法研究采煤机的定位技术,并对液压支架定姿的关键技术进行了分析,期望提高薄煤层自动化系统在煤矿井下的适应性,减少工作面的操作人员,提高煤矿生产的效率。 展开更多
关键词 煤矿生产 自动控制 液压支架定姿 采煤机定位
下载PDF
全自动分析仪与经典化学法监测地表水中总氮的比对实验研究
19
作者 范明晶 卢立猛 杨翠萍 《皮革制作与环保科技》 2024年第3期137-139,共3页
总氮是控制水质质量的重要指标之一,是湖泊、水库、河流的常规监测项目。水中总氮的测定被列为国家地表水环境质量标准的基本项目,也是城镇污染物排放标准中的基本控制项目,所以准确、高效地测定水中总氮十分必要。本文以崂山区地表水... 总氮是控制水质质量的重要指标之一,是湖泊、水库、河流的常规监测项目。水中总氮的测定被列为国家地表水环境质量标准的基本项目,也是城镇污染物排放标准中的基本控制项目,所以准确、高效地测定水中总氮十分必要。本文以崂山区地表水监测的工作实际为研究依据,从安全性能、监测质量、监测效率等方面对两种分析方式进行比对实验,从而保障和推进生态环境地表水水质监测中总氮项目监测过程的准确和高效。 展开更多
关键词 环境监测 水中总氮的测定 全自动分析仪 仪器法
下载PDF
一种基于六轴机器人和机器视觉技术的磁性、电涡流式覆层厚度测量仪自动检定装置
20
作者 陈秋天 崔万里 +1 位作者 田慧娟 朱蒙蒙 《计量与测试技术》 2024年第9期41-44,共4页
针对传统磁性、电涡流式覆层厚度测量仪人工检定效率低、数据处理工作量大等问题,提出一种基于六轴机器人和机器视觉技术的磁性、电涡流式覆层厚度测量仪自动检定装置,并进行试验验证。结果表明:该装置可替代传统人工进行检定及数据处理... 针对传统磁性、电涡流式覆层厚度测量仪人工检定效率低、数据处理工作量大等问题,提出一种基于六轴机器人和机器视觉技术的磁性、电涡流式覆层厚度测量仪自动检定装置,并进行试验验证。结果表明:该装置可替代传统人工进行检定及数据处理,不仅能确保检定的准确度,而且能提高检定效率,实现等级的自动判定。 展开更多
关键词 磁性 电涡流式覆层厚度测量仪 自动检定 机器人 CCD 智能算法 等级判定