The work is dedicated to develop a one-step eco-friendly method to prepare antibacterial polyethylene terephthalate(PET).We report a one-step eco-friendly method to manufacture antibacterial PET via on-line amination ...The work is dedicated to develop a one-step eco-friendly method to prepare antibacterial polyethylene terephthalate(PET).We report a one-step eco-friendly method to manufacture antibacterial PET via on-line amination reaction by melt coextrusion.Beside evenly mixing of poly(hexamethylene guanidine)(PHMG)and PET in the melt coextrusion procedure,the amination reaction also occurred between PHMG and PET under high temperature(230-270℃).The antibacterial ability of composite PET showed obvious PHMG concentration dependence,and antibacterial activity reached more than 99%when PHMG content was 2.5 wt%.Moreover,LIVE/DEAD fluorescence test further confirmed that the composite PET could kill bacteria quickly and efiectively(within 30 min);while negligible cytotoxicity was observed to HSF and HUVEC cells.Onestep eco-friendly fabrication of composite antibacterial PET was accomplished by on-line melt coextrusion.The composite antibacterial PET has potential use in multiple fields to combat with pathogenic including textiles,packaging materials,decoration materials and biomedical devices,etc.展开更多
The valuation relation of potential difference with discharging time in Electrical Discharge Machining (EDM) is analyzed theoretically and tested and verified by experiments designed in this paper and the relation bet...The valuation relation of potential difference with discharging time in Electrical Discharge Machining (EDM) is analyzed theoretically and tested and verified by experiments designed in this paper and the relation between potential difference and spark location is induced and analyzed, and proceed by experiments under the condition of onedimension.展开更多
On-line measurement for dielectric loss angle can effectively monitor the insulation condition of capacitive equipment in power systems. Synthetic relative measuring methods not only markedly overcome the shortcomings...On-line measurement for dielectric loss angle can effectively monitor the insulation condition of capacitive equipment in power systems. Synthetic relative measuring methods not only markedly overcome the shortcomings of traditional absolute measuring methods but also greatly improve the accuracy of dielectric loss angle measurement. However, synthetic relative measuring methods based on two or three pieces of capacitive equipment do not have the characteristic of generality. In this paper, a principle of synthetic relative measuring method is presented. The example of application for synthetic relative methods based on three and four pieces of capacitive equipment running in the same phase is taken to present the failure judgment matrices for N pieces of equipment. According to these matrices, the fault condition of N pieces of capacitive equipment can be watched, which is more general. Then some problems needing to be concerned along with two diagnostic methods used in diagnostic system are introduced. Finally, two programmable flow charts for the two methods are given and corresponding examples demonstrate their feasibility in practice.展开更多
High reliability is the key to performance of electrical control equipment. PLC combines computer technology, automatic control technology and communication technology and becomes widely used for automation of industr...High reliability is the key to performance of electrical control equipment. PLC combines computer technology, automatic control technology and communication technology and becomes widely used for automation of industrial processes. Some requirements of complex PLC systems cannot be satisfied by the traditional verification methods. In this paper, an efficient method for the PLC systems modeling and verification is proposed. To ensure the high-speed property of PLC, we proposed a technique of “Time interval model” and “notice-waiting”. It could reduce the state space and make it possible to verify some complex PLC systems. Also, the conversion from the built PLC model to the Promela language is obtained and a tool PLC-Checker for modeling and checking PLC systems are designed. Using PLC-Checker to check a classical PLC example, a counter-example is found. Although the probability of this logic error occurs very small, it could result in system crash fatally.展开更多
This paper describes a data transmission method using a cyclic redundancy check and inaudible frequencies.The proposed method uses inaudible high frequencies from 18 k Hz to 22 k Hz generated via the inner speaker of ...This paper describes a data transmission method using a cyclic redundancy check and inaudible frequencies.The proposed method uses inaudible high frequencies from 18 k Hz to 22 k Hz generated via the inner speaker of smart devices.Using the proposed method,the performance is evaluated by conducting data transmission tests between a smart book and smart phone.The test results confirm that the proposed method can send 32 bits of data in an average of 235 ms,the transmission success rate reaches 99.47%,and the error detection rate of the cyclic redundancy check is0.53%.展开更多
基金Funded by the National Natural Science Foundation of China(No.51703169)Key Program of Science and Technology of Jieyang City(No.2019016)Key Research and Development Program of Shandong Province of China(No.2019JZZY010338)。
文摘The work is dedicated to develop a one-step eco-friendly method to prepare antibacterial polyethylene terephthalate(PET).We report a one-step eco-friendly method to manufacture antibacterial PET via on-line amination reaction by melt coextrusion.Beside evenly mixing of poly(hexamethylene guanidine)(PHMG)and PET in the melt coextrusion procedure,the amination reaction also occurred between PHMG and PET under high temperature(230-270℃).The antibacterial ability of composite PET showed obvious PHMG concentration dependence,and antibacterial activity reached more than 99%when PHMG content was 2.5 wt%.Moreover,LIVE/DEAD fluorescence test further confirmed that the composite PET could kill bacteria quickly and efiectively(within 30 min);while negligible cytotoxicity was observed to HSF and HUVEC cells.Onestep eco-friendly fabrication of composite antibacterial PET was accomplished by on-line melt coextrusion.The composite antibacterial PET has potential use in multiple fields to combat with pathogenic including textiles,packaging materials,decoration materials and biomedical devices,etc.
文摘The valuation relation of potential difference with discharging time in Electrical Discharge Machining (EDM) is analyzed theoretically and tested and verified by experiments designed in this paper and the relation between potential difference and spark location is induced and analyzed, and proceed by experiments under the condition of onedimension.
文摘On-line measurement for dielectric loss angle can effectively monitor the insulation condition of capacitive equipment in power systems. Synthetic relative measuring methods not only markedly overcome the shortcomings of traditional absolute measuring methods but also greatly improve the accuracy of dielectric loss angle measurement. However, synthetic relative measuring methods based on two or three pieces of capacitive equipment do not have the characteristic of generality. In this paper, a principle of synthetic relative measuring method is presented. The example of application for synthetic relative methods based on three and four pieces of capacitive equipment running in the same phase is taken to present the failure judgment matrices for N pieces of equipment. According to these matrices, the fault condition of N pieces of capacitive equipment can be watched, which is more general. Then some problems needing to be concerned along with two diagnostic methods used in diagnostic system are introduced. Finally, two programmable flow charts for the two methods are given and corresponding examples demonstrate their feasibility in practice.
文摘High reliability is the key to performance of electrical control equipment. PLC combines computer technology, automatic control technology and communication technology and becomes widely used for automation of industrial processes. Some requirements of complex PLC systems cannot be satisfied by the traditional verification methods. In this paper, an efficient method for the PLC systems modeling and verification is proposed. To ensure the high-speed property of PLC, we proposed a technique of “Time interval model” and “notice-waiting”. It could reduce the state space and make it possible to verify some complex PLC systems. Also, the conversion from the built PLC model to the Promela language is obtained and a tool PLC-Checker for modeling and checking PLC systems are designed. Using PLC-Checker to check a classical PLC example, a counter-example is found. Although the probability of this logic error occurs very small, it could result in system crash fatally.
基金supported by Ministry of Educationunder Basic Science Research Program under Grant No.NRF-2013R1A1A2061478
文摘This paper describes a data transmission method using a cyclic redundancy check and inaudible frequencies.The proposed method uses inaudible high frequencies from 18 k Hz to 22 k Hz generated via the inner speaker of smart devices.Using the proposed method,the performance is evaluated by conducting data transmission tests between a smart book and smart phone.The test results confirm that the proposed method can send 32 bits of data in an average of 235 ms,the transmission success rate reaches 99.47%,and the error detection rate of the cyclic redundancy check is0.53%.