期刊文献+
共找到6,149篇文章
< 1 2 250 >
每页显示 20 50 100
STRONGLY CONVERGENT INERTIAL FORWARD-BACKWARD-FORWARD ALGORITHM WITHOUT ON-LINE RULE FOR VARIATIONAL INEQUALITIES
1
作者 姚永红 Abubakar ADAMU Yekini SHEHU 《Acta Mathematica Scientia》 SCIE CSCD 2024年第2期551-566,共16页
This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inerti... This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inertial parameters and the iterates,which have been assumed by several authors whenever a strongly convergent algorithm with an inertial extrapolation step is proposed for a variational inequality problem.Consequently,our proof arguments are different from what is obtainable in the relevant literature.Finally,we give numerical tests to confirm the theoretical analysis and show that our proposed algorithm is superior to related ones in the literature. 展开更多
关键词 forward-backward-forward algorithm inertial extrapolation variational inequality on-line rule
下载PDF
Determination of triazine herbicide residues in water samples by on-line sweeping concentration in micellar electrokinetic chromatography 被引量:2
2
作者 Shuai Hua Zhang Yuan Yuan Yang Dan Dan Han Chun Wang Xin Zhou Xiao Huan Zang Zhi Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第12期1487-1490,共4页
A new method for the determination of atrazine, simazine and prometryn in water samples by on-line sweeping concentration technique in micellar electrokinetic chromatography (MEKC) was developed. Various parameters ... A new method for the determination of atrazine, simazine and prometryn in water samples by on-line sweeping concentration technique in micellar electrokinetic chromatography (MEKC) was developed. Various parameters affecting sample enrichment and separation efficiency were systematically studied. Compared with the conventional MEKC method, up to 60-200-fold improvement in concentration sensitivity was achieved in terms of peak height by using this sweeping injection technique. The compound strychnine was used as the internal standard for the improvement of the experimental reproducibility. The limits of detection (S/ N = 3:1) for atrazine, simazine and prometryn were 9, 10 and 0.5 ng mL-1, respectively. This method has been successfully applied to the analysis of atrazine, simazine and prometryn in lake, steam and ground water. 展开更多
关键词 Triazine herbicides on-line concentration MEKC SWEEPING Water samples
下载PDF
Rapid analysis of fifteen sulfonamide residues in pork and fish samples by automated on-line solid phase extraction coupled to liquid chromatography–tandem mass spectrometry 被引量:7
3
作者 Junmei Ma Sufang Fan +3 位作者 Lei Sun Liangna He Yan Zhang Qiang Li 《Food Science and Human Wellness》 SCIE 2020年第4期363-369,共7页
The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples... The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish. 展开更多
关键词 Liquid chromatography–tandem mass SPECTROMETRY on-line solid phase extraction SULFONAMIDES Internal standard quantification
下载PDF
On-line Sweeping Sample Concentration in Micellar Electrokinetic Chromatography with Enhanced Sensitivity for the Deter-mination of Carbamazepine in Human Serum 被引量:1
4
作者 Dan Dan HAN Chun WANG +2 位作者 Zhi WANG Qiu Hua WU Xiao Huan ZANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第7期953-956,共4页
A sensitive and simple micellar electrokinetic chromatography (MEKC) method was developed for the determination of antiepileptic drug, carbamazepine (CBZ), using sweeping on-line concentration method with photodio... A sensitive and simple micellar electrokinetic chromatography (MEKC) method was developed for the determination of antiepileptic drug, carbamazepine (CBZ), using sweeping on-line concentration method with photodiode array detection. Under the optimal conditions, the calibration curve was linear over a range of 0.5-40μg·mL^-1 for CBZ with a correlation coefficient of 0.998. The detection limit (S/N = 3:1) of CBZ was 0.10 μg·mL^-1. The sweeping-MEKC method has been successfully applied to the analysis of CBZ in human serum. 展开更多
关键词 on-line concentration carbarnazepine MEKC SWEEPING human serum.
下载PDF
On-line enrichment and determination of polycyclic aromatic hydrocarbons in atmospheric particulates using high performance liquid chromatography with fluorescence as detector 被引量:1
5
作者 HASHI Yuki WANG Tian-ran +1 位作者 LI Yue-qi LIN Jin-ming 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第10期1261-1265,共5页
Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enri... Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enrichment trap column. The method simplified the sample pretreatment, saved time and increased the efficiency. With the on-line trap column, PAHs were separated availably even underground injecting 1.0 ml sample with relatively high column efficiency. The recoveries of the seven PAHs were from 85% to 120% for spiked atmospheric particulate sample. The limit of detection was 15.3-39.6 ng/L (S/N=3.3). There were good linear correlations between the peak areas and concentrations of the seven kinds of PAHs in the range of 1-50 ng/ml with the correlation coefficients over 0.9970. Furthermore, it also indicated that the method is available to determine PAHs in atmospheric particulates well. 展开更多
关键词 on-line enrichment on-line trap column high performance liquid chromatography (HPLC) atmospheric particulate polycyclic aromatic hydrocarbons (PAHs)
下载PDF
On-Line Pyrolysis-Liquid Chromatography of (Meth-) Acrylic Acid in Waterborne Polymers Using Cryogenic Injection
6
作者 Aschwin van der Horst Jaqueline Slaakweg Karen Huiskes Yannic van Hooijdonk Afke Kroes 《Journal of Chemistry and Chemical Engineering》 2014年第7期668-675,共8页
Pyrolysis gas chromatography is not a comprehensive analysis method for the determination of acrylics. Polar acrylic monomers show low abundance by gas chromatography. Because of this, a home-made pyrolysis liquid chr... Pyrolysis gas chromatography is not a comprehensive analysis method for the determination of acrylics. Polar acrylic monomers show low abundance by gas chromatography. Because of this, a home-made pyrolysis liquid chromatographic injector by means of cryogenic-focussing is developed to determine the presence and concentration of hydroxyl and carboxyl functional monomers present in water- and solvent-borne acrylics. We have shown the prove-of-principle of using cryogenic-focussing for UPLC (pyrolysis-ultra-performance liquid chromatography) injection. 展开更多
关键词 on-line pyrolysis-UPLC acrylic acid methacrylic acid cryogenic injection.
下载PDF
Coupling of on-Line Pre-Column Oxidative Cleavage and Solid-Phase Enrichment with Liquid Chromatography Using an Eco-Friendly Analytical Procedure to Determine Low Levels of Methotrexate
7
作者 Samy Emara Walaa Zarad +1 位作者 Maha Kamal Ramzia EL-Bagary 《Journal of Analytical Sciences, Methods and Instrumentation》 2012年第4期194-202,共9页
A simple, sensitive and precise green high-performance liquid chromatographic method including on-line pre-column oxidation combined by column switching with a short Hypersil ODS analytical column (100 mm × 4.0 m... A simple, sensitive and precise green high-performance liquid chromatographic method including on-line pre-column oxidation combined by column switching with a short Hypersil ODS analytical column (100 mm × 4.0 mm i.d.) for enrichment and separation was developed and validated to determine low levels of methotrexate (MTX). The method was based on oxidative cleavage of MTX into highly fluorescence products, 2,4-diaminopteridine-6-carboxaldehyde and the corresponding 2,4-diaminopteridine-6-carboxylic acid, during the flow of phosphate buffer (0.04 M, pH 3.4) containing the analyte through the packed reactor of cerium (IV) trihydroxyhydroperoxide (CTH) at a flow-rate of 0.2 mL/min and 40℃. The fluorescent products were enriched on the head of ODS analytical column for the final separation. The separation was performed at room temperature using an environmentally friendly mobile phase consisting of ethanol and phosphate buffer (0.04 M, pH 3.4) in the ratio of 10:90 (v/v). The eluent was monitored at emission and excitation wavelengths of 463 and 367 nm, respectively. The method was successfully applied, without any interference from the excipients, for the determination of drug in tablets and vials with a detection limit of 0.06 ng/mL from 500 ?L of sample MTX. 展开更多
关键词 Cerium (IV) Trihydroxyhydroperoxide HPLC METHOTREXATE ODS ANALYTICAL Column on-line Pre-Column Oxidative CLEAVAGE
下载PDF
Multi-Sensor Intelligent System for On-Line and Real-Time Moneitoring Tool Cutting State in FMS 被引量:1
8
作者 徐春广 王信义 +1 位作者 邢济收 杨大勇 《Journal of Beijing Institute of Technology》 EI CAS 1997年第3期258-266,共9页
The principle and the constitution of an intelligent system for on-line and real-time montitoring tool cutting state were discussed and a synthetic sensors schedule combined a new type fluid acoustic emission sens... The principle and the constitution of an intelligent system for on-line and real-time montitoring tool cutting state were discussed and a synthetic sensors schedule combined a new type fluid acoustic emission sensor (AE) with motor current sensor was presented. The parallel communication between control system of machine tools, the monitoring intelligent system,and several decision-making systems for identifying tool cutting state was established It can auto - matically select the sensor way ,monitoring mode and identifying method in machining process- ing so as to build a successful and effective intelligent system for on -line and real-time moni- toring cutting tool states in FMS. 展开更多
关键词 tool cutting state on-line monitoring intelligent system acoustic emission sensor
下载PDF
On-line机行血液透析滤过两种稀释模式效果的临床观察 被引量:2
9
作者 易铁钢 祁爱蓉 程淑碧 《中国血液净化》 2004年第1期41-42,47,共3页
关键词 on-line 血液透析滤过 稀释模式 HDF 治疗 血液净化
下载PDF
On-line hemodiafiltration技术和临床应用 被引量:25
10
作者 谢红浪 季大玺 《肾脏病与透析肾移植杂志》 CAS CSCD 2005年第4期377-381,共5页
关键词 血液净化 肾脏疾病 临床 on-line 临床应用 肾脏替代治疗 终末期肾脏疾病 血液透析滤过 常规血液透析 生物相容性
下载PDF
On-line血液透析滤过对移植肾功能延迟恢复的影响 被引量:1
11
作者 余权星 刘强 +2 位作者 杜艺 李宓 彭莉 《中国血液净化》 2004年第4期192-193,200,共3页
目的 研究On -line血液透析滤过 (HDF)在移植肾功能延迟恢复患者中的应用。方法 我院2 0 0 2年 1月至 2 0 0 3年 7月肾移植术后发生移植肾功能延迟恢复患者 38例 ,2 9例采用Freseniuson -lineHDF透析机 ,F6 0透析器 ,透析滤过时间 3~... 目的 研究On -line血液透析滤过 (HDF)在移植肾功能延迟恢复患者中的应用。方法 我院2 0 0 2年 1月至 2 0 0 3年 7月肾移植术后发生移植肾功能延迟恢复患者 38例 ,2 9例采用Freseniuson -lineHDF透析机 ,F6 0透析器 ,透析滤过时间 3~ 4h ,血流量在 180~ 2 5 0ml/min ,置换液采取前稀释法 ,9例行HD治疗 ,采用GambroAK2 0 0透析机 ,F7透析器。结果  38例移植肾功能延迟恢复患者 ,2 9例用联机血液透析滤过 ,平均肾功能恢复时间为 ( 11.2± 5 .6 )天 ,治疗期间收缩压变化在 110~ 170mmHg,透析期间低血压发生率为 2 .6 % ,9例HD治疗者平均肾功能恢复时间为 ( 2 2 .3± 15 .7)天 ,透析期间低血压发生率为 13.2 %。结论 与HD比较 ,On -lineHDF对血压影响较小 ,可缩短移植肾功能恢复的时间。 展开更多
关键词 on-line血液透析 肾功能 肾移植 HDF
下载PDF
Development and Application of On-Line Corrosion Monitoring Device for Condenser Tube 被引量:1
12
作者 曹杰玉 宋敬霞 +2 位作者 汪德良 龙国军 孙本达 《Electricity》 2004年第2期31-35,共5页
This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current te... This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current test, which enable the monitoring result to be consistent with the corrosion of actual condenser tubes. Localized corrosion rate of condenser tubes can be measured indirectly by a galvanic couple made up of tube segments with and without pits. Using this technology, corrosion problems can be found in time and accurately, and anticorrosive measures be made more economic and effective. Applications in two power plants showed the corrosion measurements are fast and accurate. 展开更多
关键词 condenser tube CORROSION on-line monitoring INSTRUMENTATION
下载PDF
平行机的实时到达on-line算法下界的改进 被引量:1
13
作者 陈仕平 姚恩瑜 《高校应用数学学报(A辑)》 CSCD 北大核心 1999年第3期315-318,共4页
本文考虑了平行机实时到达的在线问题.模型中,工件是陆续到达的,工件的个数、到达时间是事先未知的,而且只有当工件到达,才知其加工时间,目标是使所有工件都加工完的时间达到最小.Chen与Vestjens(1996年)证明... 本文考虑了平行机实时到达的在线问题.模型中,工件是陆续到达的,工件的个数、到达时间是事先未知的,而且只有当工件到达,才知其加工时间,目标是使所有工件都加工完的时间达到最小.Chen与Vestjens(1996年)证明了该在线问题不存在性能比小于1.3473的on-line算法.本文将此界改进为(5-5)/2. 展开更多
关键词 排序 on-line算法 平行机 组合最优化 实时到达
下载PDF
Effects of on-line solution and off-line heat treatment on microstructure and hardness of die-cast AZ91D alloy 被引量:1
14
作者 徐玉磊 张奎 +3 位作者 李兴刚 雷健 袁海波 刘正 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2012年第11期2652-2658,共7页
The effects of on-line solution, off-line solution and aging heat treatment on the microstructure and hardness of the die-cast AZ91D alloys were investigated. Brinell hardness of die-cast AZ91D alloy increases through... The effects of on-line solution, off-line solution and aging heat treatment on the microstructure and hardness of the die-cast AZ91D alloys were investigated. Brinell hardness of die-cast AZ91D alloy increases through on-line solution and off-line aging treatment but decreases after off-line solution treatment. By X-ray diffractometry, optical microscopy, differential thermal analysis, scanning electron microscopy and X-ray energy dispersive spectroscopy, it is found that the microstructures of the die-cast AZ91D magnesium alloy before and after on-line solution and off-line aging are similar, consisting of α-Mg and β-Al12Mg17. The precipitation of Al element is prevented by on-line solution so that the effect of solid solution strengthening is enhanced. The β-Al12Mg17 phases precipitate from supersaturated Mg solid solution after off-line aging treatment, and lead to microstructure refinement of AZ91D alloy, so the effect of precipitation hardening is enhanced. The β-Al12Mg17 phases dissolve in the substructure after off-line solution treatment, which leads to that the grain boundary strengthening phase is reduced significantly and the hardness of die cast AZ91D is reduced. 展开更多
关键词 die-cast magnesium alloy AZ91D alloy on-line solution off-line solution treatment aging treatment β-Al12Mg17 phases microstructure refinement precipitation hardening
下载PDF
On-line血液透析滤过对维持性血液透析患者心率变异性的影响 被引量:5
15
作者 侯丹丹 王淑领 尚赛男 《临床和实验医学杂志》 2017年第17期1761-1764,共4页
目的探讨On-line血液透析滤过技术对维持性血液透析患者心率变异性(HRV)的影响。方法 50例维持性血液透析(MHD)患者随机分为常规血液透析治疗组(HD组)和On-line血液透析滤过治疗组(OL-HDF组),每组各25例。患者每周行3次、每次4 h的血液... 目的探讨On-line血液透析滤过技术对维持性血液透析患者心率变异性(HRV)的影响。方法 50例维持性血液透析(MHD)患者随机分为常规血液透析治疗组(HD组)和On-line血液透析滤过治疗组(OL-HDF组),每组各25例。患者每周行3次、每次4 h的血液透析治疗或OL-HDF,治疗24个月。比较两组常规的实验室检查和24h动态心电图监测结果。结果治疗24个月后,OL-HDF组的β2-微球蛋白(β2-MG)由基线值30.1±7.2 mg/dl降至21.7±6.1 mg/dl(P<0.05),HD组的β2-MG则无明显下降。OL-HDF组HRV的时域性和频域性指标均值高于基线值(P<0.05),HD组的HRV指标则无显著性变化(P>0.05)。结论与普通血液透析比较,OL-HDF能更好地改善MHD患者的HRV,改善自主神经功能。 展开更多
关键词 维持性血液透析 on-line血液透析滤过心率变异性
下载PDF
On-line置换液与生理盐水在血液透析滤过回血中的应用效果比较 被引量:5
16
作者 祝喜鹰 刘金凤 肖静 《护理研究(上旬版)》 2014年第7期2370-2372,共3页
[目的]探讨On-line置换液与生理盐水在血液透析滤过(HDF)病人回血中的应用效果,以期为临床护理工作提供理论依据。[方法]选取30例规律HDF病人为研究对象,采用自身对照方法,每例病人每周依次采用On-line置换液和生理盐水回血,比较回血过... [目的]探讨On-line置换液与生理盐水在血液透析滤过(HDF)病人回血中的应用效果,以期为临床护理工作提供理论依据。[方法]选取30例规律HDF病人为研究对象,采用自身对照方法,每例病人每周依次采用On-line置换液和生理盐水回血,比较回血过程中残余血量、静脉壶液体温度、护士的工作量及经济效益。[结果]采用On-line置换液回血法残余血量及回血后静脉壶温度分别为(1.89±0.91)mL,(33.36±0.15)℃,而采用生理盐水法为(2.88±0.23)mL、(27.13±0.14)℃,差异均有统计学意义(P<0.01);而透析器凝血状况比较差异无统计学意义(P=0.08);采用On-line置换液回血时护士工作量减少,回血液体成本降低。[结论]应用接近生理温度的On-line置换液回血能稀释血液、降低血液黏稠度,减少血路管残余血量,增加病人舒适感,提高工作效率。 展开更多
关键词 联机血液透析滤过 液体回血 on-line置换液 生理盐水 残余血量 工作量
下载PDF
On-lineHDF的临床观察及护理 被引量:1
17
作者 李虹 张永勤 汪吉平 《实用全科医学》 2004年第3期280-281,共2页
目的 探讨应用On -lineHDF治疗慢性肾衰尿毒症患者的临床效果及护理对策。方法 回顾性分析 15例维持性HD患者应用On -lineHDF的治疗及护理过程。结果  15例患者经每 1~ 2周 1次的On -lineHDF治疗后 ,病情稳定 ,部分患者心功能、血... 目的 探讨应用On -lineHDF治疗慢性肾衰尿毒症患者的临床效果及护理对策。方法 回顾性分析 15例维持性HD患者应用On -lineHDF的治疗及护理过程。结果  15例患者经每 1~ 2周 1次的On -lineHDF治疗后 ,病情稳定 ,部分患者心功能、血压、食欲、体力及睡眠不同成度得到改善 ,在促红细胞生成素使用量不变的情况下 ,4例病人的血红蛋白有所增加。结论 On -lineHDF是当今最佳的肾脏替代疗法技术之一。 展开更多
关键词 on-line HDF 护理措施 血液透析 置换液 治疗
下载PDF
On-Line Monitoring of Cutting Tool Fracture & Wear
18
作者 王信义 肖定国 宋新民 《Journal of Beijing Institute of Technology》 EI CAS 1992年第2期139-150,共12页
A technique of detecting cutting tool fracture and ultimate wear by si- multaneously monitoring both the spindle motor current and cutting process related acoustic emission(AE)in the cutting process is reported.The te... A technique of detecting cutting tool fracture and ultimate wear by si- multaneously monitoring both the spindle motor current and cutting process related acoustic emission(AE)in the cutting process is reported.The technique can detect breakage of drills having diameter over 0.8mm,turning cutter crack of area over 0.2mm,and the ultimate wear.The principle,system construction,experimental method and result of the technique are discussed.The ratio of success in detection approaches 96% or higher. 展开更多
关键词 on-line monitoring acoustic emission/tool fracture motor current
下载PDF
On-line HDF治疗维持性透析患者并发症的护理
19
作者 孙静 安茂竹 +2 位作者 毛继芳 秦美华 马芳 《当代护士(中旬刊)》 2007年第10期32-33,共2页
对20例维持性透析并发难治性高血压、顽固性瘙痒、不安腿综合征等患者,采用每周2次血液透析+1次on-line HDF,加强观察和护理。患者血压得到良好的控制,皮肤瘙痒得到明显改善,不安腿症状有所好转,贫血、食欲减退、精神和神经症状得到改善... 对20例维持性透析并发难治性高血压、顽固性瘙痒、不安腿综合征等患者,采用每周2次血液透析+1次on-line HDF,加强观察和护理。患者血压得到良好的控制,皮肤瘙痒得到明显改善,不安腿症状有所好转,贫血、食欲减退、精神和神经症状得到改善,生活质量明显提高。 展开更多
关键词 透析 并发症 on-line HDF 护理
下载PDF
透析机自产回输液行血液透析滤过On-line HDF的临床研究
20
作者 向允禧 钟爱民 +4 位作者 刘鸿 魏小昌 漆映辉 李赟 甘小英 《江西医药》 CAS 2005年第5期249-250,共2页
目的探讨On-lineHDF的安全性、病人耐受性及临床疗效。方法设置On-lineHDF治疗组(I组)和常规HD对照组(II组),观察治疗前、中、后病人状况,溶质变化和溶质下降率,包括Cr、BUN、β2-MG、PTH、KT/V。结果HDF治疗中、治疗后病人无发热,6例... 目的探讨On-lineHDF的安全性、病人耐受性及临床疗效。方法设置On-lineHDF治疗组(I组)和常规HD对照组(II组),观察治疗前、中、后病人状况,溶质变化和溶质下降率,包括Cr、BUN、β2-MG、PTH、KT/V。结果HDF治疗中、治疗后病人无发热,6例顽固性血压易于控制,5例在HD中易出现低血压症状好转,3例皮肤瘙痒严重者明显好转,HDF组治疗前后Cr,β2-MG,PTH显著下降;HD组治疗前后β2-MG、PTH相差不显著。治疗前及2月后溶质变化,两组Cr,β2-MG相差不显著;HDF组PTH前后有显著性差异;KT/V值比较,HDF为1.68±0.34,HD为1.21±0.23,两组有显著性差异(P<0.05)。结论On-lineHDF较传统HDF操作简单,自产回输液安全,病人有较好的耐受性和心血管稳定性,其对小分子、中分子物质的清除能力优于常规HD。 展开更多
关键词 自产回输液 清除率 透析机 血液透析 on-line HDF 血浓度
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部