期刊文献+
共找到864篇文章
< 1 2 44 >
每页显示 20 50 100
Atmospheric Corrosion Monitoring of Field-exposed Q235B and T91 Steels in Zhoushan Offshore Environment Using Electrochemical Probes 被引量:1
1
作者 夏大海 SONG Shizhe +4 位作者 JIN Weixian LI Jian 高志明 WANG Jihui HU Wenbin 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2017年第6期1433-1440,共8页
This work aimed to in-situ monitor the atmospheric corrosion of steels exposed to Zhoushan offshore environment by using electrochemical noise(EN) technique. A portable EN monitoring system was established and two e... This work aimed to in-situ monitor the atmospheric corrosion of steels exposed to Zhoushan offshore environment by using electrochemical noise(EN) technique. A portable EN monitoring system was established and two electrochemical probes(named as Q235 B and T91) were designed. Experimental results indicated that the noise resistance of T91 steel was higher than that of Q235 B steel, revealing that the corrosion resistance of T91 was higher than that of Q235 B. A 60-day monitoring result indicated that the noise resistance was well correlated with the weight loss data. Wavelet analyses results of EN data indicated that Q235 B underwent uniform corrosion and T91 suffered from localized corrosion, which was further confirmed by the surface observation. It is concluded that EN can be used as a new method to identify the corrosion form and corrosion resistance in atmospheric conditions. 展开更多
关键词 atmospheric corrosion electrochemical noise corrosion monitoring OFFSHORE in field
下载PDF
Preparation and Properties of Embeddable Ag/Ag Cl Gelling Reference Electrode for Rebars Corrosion Monitoring in Concrete 被引量:1
2
作者 汤雁冰 王胜年 +1 位作者 陈龙 范志宏 《China Ocean Engineering》 SCIE EI CSCD 2015年第6期925-932,共8页
Reference electrodes are a key part for corrosion monitoring and measurement of rebars in concrete. A reference electrode that can be buried in concrete is fabricated by using Ag/Ag Cl electrode and methyl cellulose g... Reference electrodes are a key part for corrosion monitoring and measurement of rebars in concrete. A reference electrode that can be buried in concrete is fabricated by using Ag/Ag Cl electrode and methyl cellulose gelling electrolyte. The stability, repeatability and anti-polarization of the reference electrode are investigated; the influences of the inner electrolyte loss, exterior OH- contamination, and temperature on the potential of the reference electrode are also investigated in this paper. The results show that the reference electrode has good stability, repeatability, and antipolarization. The influences of inner electrolyte loss, exterior OH- contamination, and temperature on the potential of the reference electrode are minimal. Therefore, it can be used for corrosion monitoring and measurement of rebars in concrete. 展开更多
关键词 reference electrode methyl cellulose gelling electrolyte Ag/AgCl electrode corrosion monitoring rebarsconcrete
下载PDF
Research on Distribution of Electromagnetic Environment around Substations and Optimization Layout of On-line Monitoring 被引量:1
3
作者 Li Peiming Xiao Jun Wang Wenjin 《Meteorological and Environmental Research》 CAS 2019年第6期60-63,共4页
The characteristics and distribution law of electromagnetic environment around substations with different levels of voltage were studied,and the main influencing factors were discussed. Meanwhile,a scheme for locating... The characteristics and distribution law of electromagnetic environment around substations with different levels of voltage were studied,and the main influencing factors were discussed. Meanwhile,a scheme for locating monitoring points suitable for an on-line monitoring system of electromagnetic environment was proposed. 展开更多
关键词 on-line monitoring ELECTROMAGNETIC environment SUBSTATION Optimization layout
下载PDF
On-line monitoring of dissolved gas-in-oil with FTIR spectra 被引量:1
4
作者 XianyongLiu YunluoLiu LiYue 《Journal of University of Science and Technology Beijing》 CSCD 2003年第4期65-68,共4页
To overcome the disadvantages of conventional DGA (dissolved gas-in-oil)analysis using gas chromatography and other electrochemical sensors, initial researches werecompleted to realize on-line monitoring of dissolved ... To overcome the disadvantages of conventional DGA (dissolved gas-in-oil)analysis using gas chromatography and other electrochemical sensors, initial researches werecompleted to realize on-line monitoring of dissolved gas-in-oil of power transformers using FTIR(Fourier Transform InfraRed) spectroscopy. Gas cell method is used to determine the characteristicabsorption peaks of each diagnostic gas; simple and novel devices and procedures were designed inorder to get measurable samples and spectra of mixed diagnostic gases with known concentration aretaken using long optical path gas cell. The range of wavelength is estimated to be 3.0-13.9 mum fromexperimental spectra data. Hence the corresponding sampling frequency range should be in 536-4288Hz and usable optical materials are suggested. It is concluded that a resolution of 10 cm^(-1) maywell satisfy the monitoring of all diagnostic gases and water content except hydrogen, and thelowest detection limit may be as low as 2Xl0^(-8) to acetylene with a 2.4-meter-long optical length. 展开更多
关键词 FTIR power transformer dissolved gas-in-oil on-line monitoring INFRAREDSPECTRA
下载PDF
Preparation and performance of fluorescent sensing coating for monitoring corrosion of Al alloy 2024 被引量:4
5
作者 李松梅 张洪瑞 刘建华 《中国有色金属学会会刊:英文版》 CSCD 2006年第B01期159-164,共6页
A kind of fluorescent sensing coating was prepared for monitoring corrosion of aluminum alloys by incorporating phenylfluorone(PF) into acrylic paint as sensing material. The fluorescent dye PF reacts with aluminum io... A kind of fluorescent sensing coating was prepared for monitoring corrosion of aluminum alloys by incorporating phenylfluorone(PF) into acrylic paint as sensing material. The fluorescent dye PF reacts with aluminum ions on corroded aluminum substrate to occur fluorescence quenching observed in UV light. This paint system is sensitive to underlying corrosion processes through reacting with the Al3+ produced by anodic reaction accompanying corrosion. After a certain time, when the samples of Al alloy 2024 coated with PF-acrylic paint were immersed in 1 mol/L NaCl solution, fluorescence quenching spots can be seen with unaided eyes. With the development of corrosion process, the size of fluorescence quenching spots increases. Active corrosion areas on the sample surface were found under the fluorescence quenching spots by optical microscope. The corrosion areas can be observed more clearly by SEM, and many pits are found. This suggests that the fluorescence quenching spots are the sites of produced Al3+ by the anodic reaction of the local attack of the coated Al alloy substrate in the chloride solution and the corrosion process of the coated Al alloy can be monitored on-line by the sensing coating. The sensitivity of this coating system for detection of anodic reaction associated with corrosion was determined by applying constant charge current and measuring the charge, at which fluorescence quenching is detected in the coating with unaided eyes. Visual observation of coated samples can detect fluorescence change resulting from a charge corresponding to an equivalent hemispherical pit with approximate depth of 50 μm. 展开更多
关键词 铝合金2024 腐蚀监测 荧光光敏涂层 制备 性能
下载PDF
On-line Monitoring of Epoxy Resin Exposed to Acid Solution
6
作者 Yuyan LIU M.Ku bouchi +2 位作者 H.Semboku ya K. Tsuda T. Tomiyama 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2006年第3期414-418,共5页
In this study, a new on-line health monitoring technology for the determination of the penetration of environment solution into epoxy resin was pursued. A corrosion sensor including plastic optical fiber and pH indica... In this study, a new on-line health monitoring technology for the determination of the penetration of environment solution into epoxy resin was pursued. A corrosion sensor including plastic optical fiber and pH indicator was fabricated. The color-change layer of this sensor appeared after immersion in sulfuric acid solution, which could be examined by using optical fiber and spectrophotometer. The results showed that the penetration of sulfuric acid was detected by adding bromophenol blue (BPB) in the corrosion sensor. This system could be applied to on-line health monitoring of chemical equipment structures. 展开更多
关键词 Epoxy resin Optical fiber corrosion monitor
下载PDF
On-line Condition Monitoring and Diagnostic Network System for Rotating Machine Set 被引量:1
7
作者 Li Fucai, He Zhengjia, Zi Yanyang School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049, P. R. China 《International Journal of Plant Engineering and Management》 2000年第4期136-141,共6页
Several industrial computers and a server are combined to set up the on-line monitoring and diagnostic system of turbo-generator sets. The main function of the system is to monitor machine sets' running condition.... Several industrial computers and a server are combined to set up the on-line monitoring and diagnostic system of turbo-generator sets. The main function of the system is to monitor machine sets' running condition. Through analyzing running data, technicians can detect whether there exist faults and where they occur. To share and transmit the dynamic information of the turbo-generator sets, a distributed network system is introduced. NetWare network operating system is used in the LAN (Local Area Network) system. The LAN is extended to realize the sharing of data and remote transmission of information. Furthermore, functions of monitoring and diagnostic clients are listed. 展开更多
关键词 rotating machine set on-line monitoring and diagnostic network system
下载PDF
On-line monitoring of insulation quality of high voltage electric power equipment
8
作者 SUN He-yi, ZHAO Xue-zeng, NIE Peng, BAI Jing-feng, YANG Yan-zhu (Harbin Institute of Technology, Harbin 150001, China) 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2000年第S1期77-80,共4页
Discusses on-line monitoring of electric parameters, such as dielectric loss, divulging current, equivalent capacitance and running voltage, and presents an on-line monitoring system of insulation quality, based on mo... Discusses on-line monitoring of electric parameters, such as dielectric loss, divulging current, equivalent capacitance and running voltage, and presents an on-line monitoring system of insulation quality, based on monitoring divulging current and dielectric loss of high voltage equipment, and its advantages, such as helping people to discover the hidden problems in a timely manner, to reduce power cut and overhaul and to improve security of power supply. 展开更多
关键词 INSULATION CAPABILITY HIGH-VOLTAGE EQUIPMENT on-line monitoring data PROCESSING
下载PDF
Corrosion monitoring system design for coating wire of steel in ocean
9
作者 WEI Shi-cheng XU Bin-shi WANG Hai-dou CHEN Jian-she WEI Xu-jun 《中国有色金属学会会刊:英文版》 CSCD 2004年第z1期420-424,共5页
The monitoring system design used in anti-corrosion of coating wire of steel in ocean were concerned. A corrosion monitoring system adapting to corrosion observation of coating wire of steel was introduced in details,... The monitoring system design used in anti-corrosion of coating wire of steel in ocean were concerned. A corrosion monitoring system adapting to corrosion observation of coating wire of steel was introduced in details, including design and choice of software and hardware. This system will play an important role in the collection, procession, demonstration, deposition and accident alarm of corrosion data of oceanic coating wire of steel. 展开更多
关键词 OCEAN COATING WIRE of steel corrosion monitor
下载PDF
Research Progress of On-line Monitoring Technology for Electromagnetic Environment of Power Transmission and Transformation Projects
10
作者 Li Peiming Zhou Jian +2 位作者 Xiao Jun Wang Wenjin Ge Xiaoyang 《Meteorological and Environmental Research》 CAS 2019年第6期67-71,共5页
Based on the collection of relevant literature and cases,the research and application status of on-line monitoring technology for electromagnetic environment of power transmission and transformation projects at home a... Based on the collection of relevant literature and cases,the research and application status of on-line monitoring technology for electromagnetic environment of power transmission and transformation projects at home and abroad were introduced.Moreover,the problems existing in the on-line monitoring of electromagnetic environment were expounded,and the development prospect was forecasted. 展开更多
关键词 on-line monitoring TECHNOLOGY ELECTROMAGNETIC environment Power TRANSMISSION and TRANSFORMATION PROJECT
下载PDF
An On-line Monitoring System for Partial Dischargefrom High Voltage Transformer
11
作者 王哲 陈学允 蔡惟铮 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1998年第2期52-56,共5页
An on-line monitoring system for partial discharge from high voltage transformer is presented with structure of hardware and principle of software discussed and a new effective method combining DFT with DWT is propose... An on-line monitoring system for partial discharge from high voltage transformer is presented with structure of hardware and principle of software discussed and a new effective method combining DFT with DWT is proposed to get rid of both sinusoidal continuous noise and other external discharges. 展开更多
关键词 Partial DISCHARGE on-line monitoring technique DISCRETE FOURIER TRANSFORM (DFT) DISCRETE WAVELET transform(DWT)
下载PDF
Conductivity Method as a New Monitoring Technique for Corrosion and Corrosion Inhibition Processes of Zinc Metal
12
作者 Abdelmnim M. Altwaiq Sa’ib J. Khouri +1 位作者 Rami A. Abdel-Rahem Ahmad K. Alkhawaldeh 《American Journal of Analytical Chemistry》 2020年第10期349-361,共13页
The electrical conductivity method was successfully applied as a new monitoring technique to monitor the corrosion and corrosion inhibition processes of zinc metal. Measurements of electrical conductivity at 20.0°... The electrical conductivity method was successfully applied as a new monitoring technique to monitor the corrosion and corrosion inhibition processes of zinc metal. Measurements of electrical conductivity at 20.0°C of three different corrosive solutions (HCl, NaOH, and NaCl) were performed with two different concentrations (0.10 and 1.00 M) containing zinc sheets in the absence and presence of four different concentrations of sodium lignosulfonate (1.0, 5.0, 10.0, and 20.0 mM). The analysis of curves that illustrates the changes in electrical conductivity of these solutions provides qualitative information about the strength of corrosion as well as the extent of corrosion inhibition behavior. The results obtained from electrical conductivity measurements revealed that sodium lignosulfonate was an effective corrosion inhibitor in acidic medium (for both 0.10 and 1.00 M HCl) in which it converted into lignosulfonic acid, but was less effective in salt and alkaline media. 展开更多
关键词 CONDUCTIVITY monitoring Technique corrosion corrosion Inhibitor LIGNOSULFONATE
下载PDF
Analysis and Application of the Synthetic Relative Measuring Method in On-Line Monitoring for Capacitive Equipment in Power Systems
13
作者 Qing Guo Li-Jun Qin Hua-Wei Jin 《Journal of Electronic Science and Technology》 CAS 2011年第3期270-277,共8页
On-line measurement for dielectric loss angle can effectively monitor the insulation condition of capacitive equipment in power systems. Synthetic relative measuring methods not only markedly overcome the shortcomings... On-line measurement for dielectric loss angle can effectively monitor the insulation condition of capacitive equipment in power systems. Synthetic relative measuring methods not only markedly overcome the shortcomings of traditional absolute measuring methods but also greatly improve the accuracy of dielectric loss angle measurement. However, synthetic relative measuring methods based on two or three pieces of capacitive equipment do not have the characteristic of generality. In this paper, a principle of synthetic relative measuring method is presented. The example of application for synthetic relative methods based on three and four pieces of capacitive equipment running in the same phase is taken to present the failure judgment matrices for N pieces of equipment. According to these matrices, the fault condition of N pieces of capacitive equipment can be watched, which is more general. Then some problems needing to be concerned along with two diagnostic methods used in diagnostic system are introduced. Finally, two programmable flow charts for the two methods are given and corresponding examples demonstrate their feasibility in practice. 展开更多
关键词 Index Terms-Capacitive equipment dielectric loss angle on-line monitoring synthetic relative measuring method failure judgment matrix.
下载PDF
Insulation State On-line Monitoring and Running Management of Large Generator
14
作者 Qiudong Sun Zhengxin Zhou Weiqin Guo 《Energy and Power Engineering》 2010年第3期203-207,共5页
This study presented an insulation state monitoring method for large generator based on radio frequency (RF) technique. As an on-line condition monitor and the precondition of condition-based maintenance (CBM), the RF... This study presented an insulation state monitoring method for large generator based on radio frequency (RF) technique. As an on-line condition monitor and the precondition of condition-based maintenance (CBM), the RF monitor used the high frequency current mutual inductor to detect the partial discharge signal from neutral wire of stator windings. According to the magnitude of indicative value of RF monitor, a five phase model was also proposed to manage the generator’s running better. The practices show that the proposed method is effective. 展开更多
关键词 Large GENERATOR PARTIAL DISCHARGE RADIO Frequency Technique on-line monitoring Running MANAGEMENT
下载PDF
Wireless Distributed Monitoring Terminal Used for On-Line Application
15
作者 Fenggui Wang Lin Zhang +1 位作者 Zhongmin Wang Yanbo Zhang 《Communications and Network》 2013年第3期549-553,共5页
A wireless distributed monitoring terminal was designed with embedded Linux used on the basis of ARM board, and an application program was developed for data collection, processing and transmission. Data were collecte... A wireless distributed monitoring terminal was designed with embedded Linux used on the basis of ARM board, and an application program was developed for data collection, processing and transmission. Data were collected from the surrounding environment and transmitted to a server via WLAN in the form of Extensible Markup Language (XML) stream, so the terminal had good flexibility to be compatible with different sensors, network devices and information systems from multiple manufacturers. 展开更多
关键词 on-line monitoring DISTRIBUTED monitoring Extensible MARKUP Language (XML) STREAM WIRELESS TERMINAL
下载PDF
Mechanics Analysis of Overhead Transmission Lines Based On-line Monitoring
16
作者 Lili Dai Yongli Zhu Zehui Liang 《Open Journal of Applied Sciences》 2013年第2期1-4,共4页
At present, the on-line monitoring is widely applied to the power line monitoring. In this paper, a new mechanical calculation model is established according to the on-line monitoring. And this model is based on the p... At present, the on-line monitoring is widely applied to the power line monitoring. In this paper, a new mechanical calculation model is established according to the on-line monitoring. And this model is based on the parameters that tension sensors and angle sensors on suspended points detect, and combines with the parameters of the wire itself, and also considers the deflection angel of wires due to wind. In this model, mechanics parameters of wires are turned into the new coordinate plane after deflection angel of wires due to wind, or windage yaw plane. A statics tension balance equation is built in the vertical direction of the new windage yaw plane. According to the theoretical analysis and algorithm, we verify the accuracy of this newly developed mechanical calculation model. 展开更多
关键词 OVERHEAD Transmission Line on-line monitoring Mechanical ANALYSIS Tension ANGLE ICING Windage Yaw
下载PDF
Design of On-Line Monitoring System for UHVDC Earth Electrode
17
作者 Pinghao Ni Wei Wang Peng Wei 《Journal of Power and Energy Engineering》 2016年第2期13-18,共6页
At present the detecting of ultra high voltage direct current (UHVDC) earth electrode frequently uses manual inspection. This method can't get the real-time operational data of the earth electrodes, and meanwhile,... At present the detecting of ultra high voltage direct current (UHVDC) earth electrode frequently uses manual inspection. This method can't get the real-time operational data of the earth electrodes, and meanwhile, the labor cost is very high. In order to satisfy the security needs of UHVDC, this paper designs an on-line monitoring system for UHVDC earth electrode. By 3G wireless communication-technologies, the system can monitor remotely many kinds of data such as the value of the grounding current, water level of the observation well, soil temperature and humidity near the earth electrode, the micro-climate around the earth electrode site, video data, etc. Through analyzing the datum, the system has broad prospect on fault detection and life evaluation of the UHVDC earth electrode. 展开更多
关键词 UHVDC Earth Electrode on-line monitoring 3G
下载PDF
Monitoring of the Corrosion on a Steel Sheet-pile Marine Breakwater by Systematic Thickness Measurements
18
作者 Millan Solorzano Luis Osmel Luis Osmel 《Journal of Civil Engineering and Architecture》 2022年第10期519-530,共12页
In Quepos,Pacific of Costa Rica,it was finished on 2010 the first phase of a marina,including two mix breakwaters,with rubble mound(rocks and concrete units),and 25 circular steel sheet piles cofferdam cells,filled wi... In Quepos,Pacific of Costa Rica,it was finished on 2010 the first phase of a marina,including two mix breakwaters,with rubble mound(rocks and concrete units),and 25 circular steel sheet piles cofferdam cells,filled with sand and gravel.The maintenance plan,considers tracking sheet pile corrosion,comparing'actual'against expected rates,checking structural limits,and programming countermeasures if accelerated corrosion is identified.Specific control sections,along the breakwaters,both inside and outside the basin,were established.In each section,thicknesses were measured every meter from the top of the steel cell to seabed using an ultrasonic equipment,and an underwater transducer.Both land crew,and divers for submerged portions,were used.The measurements campaigns are for several years from 2011 to 2016.Sectors of the breakwater with varied corrosion attack levels could be differentiated.Also,corrosion rates and lifespans were estimated,both general for the structures,and specific for each section and level.In turn,this allowed to identify maintenance priorities,defining sites where measures of corrosion protection should initiate,as well,to have confidence in the structural capacity and safety of the breakwaters. 展开更多
关键词 monitoring of structures maritime works sheet piling corrosion ultrasonic thickness measurements
下载PDF
State Maintenance of On-line Monitoring for High Voltage Equipment
19
《Electricity》 1997年第2期35-36,共2页
关键词 LINE State Maintenance of on-line monitoring for High Voltage Equipment
下载PDF
An On-line Ferrograph for Monitoring Machine Wear
20
作者 LUEXiao-jun JINGMin-qing XIEYou-bai 《International Journal of Plant Engineering and Management》 2005年第1期1-7,共7页
In order to improve an on-line ferrograph, this paper simulates a three-dimensional magnetic field distribution of an electromagnet, builds a sinking motion model of a wear particle, and investigates the motion law of... In order to improve an on-line ferrograph, this paper simulates a three-dimensional magnetic field distribution of an electromagnet, builds a sinking motion model of a wear particle, and investigates the motion law of wear particles under two different conditions. Both numeric results and experimental results show that the on-line ferrograph is capable of monitoring machine wear conditions by measuring the concentration and size distribution of wear particles in lubricating oil. 展开更多
关键词 on-line ferrograph condition monitoring wear particles WEAR
下载PDF
上一页 1 2 44 下一页 到第