The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples...The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish.展开更多
Current trends in chiral analysis of pharmaceutical drugs are focused on faster separations and higher separation efficiencies, Core-shell or superficially porous particles (SPP) based chiral stationary phases (CSP...Current trends in chiral analysis of pharmaceutical drugs are focused on faster separations and higher separation efficiencies, Core-shell or superficially porous particles (SPP) based chiral stationary phases (CSPs) provide reduced analysis times while maintaining high column efficiencies and sensitivity. In this study, mobile phase conditions suitable for chiral analyses with electrospray ionization LC-MS were systematically investigated using vancomycin as a representative CSP. The performance of a 2.7 μm SPP based vancomycin CSP (SPP-V) 10 cm ×0.21 cm column was compared to that of a corresponding 5 μm fully porous particles based analogue column. The results demonstrated that the SPP-V column provides higher efficiencies, 2-5 time greater sensitivity and shorter analysis time for a set of 22 basic pharma- ceutical drugs. The SPP-V was successfully applied for the analysis of the degradation products of racemic citalopram whose enantiomers could be selectively identified by MS.展开更多
On-line chemical characterization of atmospheric particulate matter(PM)with soft ionization technique and ultrahigh-resolution Mass Spectrometry(UHRMS)provides molecular information of organic constituents in real tim...On-line chemical characterization of atmospheric particulate matter(PM)with soft ionization technique and ultrahigh-resolution Mass Spectrometry(UHRMS)provides molecular information of organic constituents in real time.Here we describe the development and application of an automatic measurement system that incorporates PM_(2.5)sampling,thermal desorption,atmospheric pressure photoionization,and UHRMS analysis.Molecular formulas of detected organic compounds were deducted from the accurate(±10 ppm)molecular weights obtained at a mass resolution of 100,000,allowing the identification of small organic compounds in PM_(2.5).Detection efficiencies of 28 standard compounds were determined and we found a high sensitivity and selectivity towards organic amines with limits of detection below 10 pg.As a proof of principle,PM_(2.5)samples collected off-line in winter in the urban area of Beijing were analyzed using the Ionization Module and HRMS of the system.The automatic system was then applied to conduct on-line measurements during the summer time at a time resolution of 2 hr.The detected organic compounds comprised mainly CHON and CHN compounds below 350 m/z.Pronounced seasonal variations in elemental composition were observed with shorter carbon backbones and higher O/C ratios in summer than that in winter.This result is consistent with stronger photochemical reactions and thus a higher oxidation state of organics in summer.Diurnal variation in signal intensity of each formula provides crucial information to reveal its source and formation pathway.In summary,the automatic measurement system serves as an important tool for the on-line characterization and identification of organic species in PM_(2.5).展开更多
In this study,we developed a novel on-line solid phase extraction(SPE)-ultra-high-performance liquid chromatography tandem mass spectrometry(UHPLC-MS/MS)-based analytical method for simultaneously quantifying 12 illic...In this study,we developed a novel on-line solid phase extraction(SPE)-ultra-high-performance liquid chromatography tandem mass spectrometry(UHPLC-MS/MS)-based analytical method for simultaneously quantifying 12 illicit drugs and metabolites(methamphetamine,amphetamine,morphine,codeine,6-monoacetylmorphine,benzoylecgonine,3,4-methylenedioxymethamphetamine,3,4-methylenedioxyamphetamine,cocaine,ketamine,norketamine,and methcathinone)and cotinine(COT)in wastewater samples.The analysis was performed by loading 2 m L of the sample onto an Oasis hydrophilic-lipophilic balance cartridge and using a cleanup step(5%methanol)to eliminate interference with a total run time of 13 min.The isotope-labeled internal standard method was used to quantify the target substances and correct for unavoidable losses and matrix effects during the on-line SPE process.Typical analytical characteristics used for method validation were sensitivity,linearity,precision,repeatability,recovery,and matrix effects.The limit of detection(LOD)and limit of quantification(LOQ)of each target were set at 0.20 ng/L and 0.50 ng/L,respectively.The linearity was between 0.5 ng/L and250 ng/L,except for that of COT.The intra-and inter-day precisions were<10.45%and 25.64%,respectively,and the relative recovery ranged from 83.74%to 162.26%.The method was used to analyze various wastewater samples from 33 cities in China,and the results were compared with the experimental results of identical samples analyzed using off-line SPE.The difference rate was between 19.91%and-20.44%,and the error range could be considered acceptable.These findings showed that on-line SPE is a suitable alternative to off-line SPE for the analysis of illicit drugs in samples.展开更多
建立一种基于美国官方分析化学师协会(Association of Official Analytical Chemists,AOAC)方法检测黑果枸杞及其制品中花青素含量的改进pH示差法。考察了黑果枸杞及其制品中花青素的最佳提取和检测条件,通过液相色谱-三重四级杆串联质...建立一种基于美国官方分析化学师协会(Association of Official Analytical Chemists,AOAC)方法检测黑果枸杞及其制品中花青素含量的改进pH示差法。考察了黑果枸杞及其制品中花青素的最佳提取和检测条件,通过液相色谱-三重四级杆串联质谱法鉴别出黑果枸杞中花青素的具体化学结构,并计算出混合花青素的平均摩尔质量。通过分光光度法测得混合花青素的平均摩尔消光系数,对改进后的pH示差法进行方法学验证和花青素的含量测定。结果显示,最佳提取和检测条件如下:黑果枸杞花青素提取溶剂为盐酸-80%(体积分数)乙醇(3∶97,体积比),料液比为1∶100(g∶mL),提取温度为50℃,提取时间为30 min,缓冲溶液稀释5倍后静置平衡20 min。液相色谱-三重四级杆串联质谱法鉴别黑果枸杞中主要以矮牵牛素类花青素为主(占97.96%),黑果枸杞特有的混合花青素平均摩尔质量为912.7 g/mol,平均摩尔消光系数为29591 L/(mol·cm)。pH示差法改进后能够满足方法学验证要求,固体样品和液体样品最低检出限分别为28.2 mg/100 g、0.282 mg/100 mL。方法改进后花青素提取增长率均大于20%,静置平衡20 min后单次检测结果精密度小于0.3%。以矮牵牛素类花青素代替矢车菊素-3-O-葡萄糖苷计算花青素含量平均提高了2.41倍,能真实地反映黑果枸杞及其制品中花青素的含量。展开更多
基于食品基质中松仁过敏原Pin k 2建立了一种超高效液相色谱-串联质谱法。将松仁经过研磨、脱脂、浸提、酶解后经Easy-nLC 1000-QExactive高分辨质谱仪进行分离分析,结合Uniprot蛋白数据库以及ProteinPilotTM软件对质谱图进行数据处理,...基于食品基质中松仁过敏原Pin k 2建立了一种超高效液相色谱-串联质谱法。将松仁经过研磨、脱脂、浸提、酶解后经Easy-nLC 1000-QExactive高分辨质谱仪进行分离分析,结合Uniprot蛋白数据库以及ProteinPilotTM软件对质谱图进行数据处理,经BLAST验证特异性,最终筛选3条松仁特异性肽段。方法学验证结果表明,方法在0.001~50mg/mL范围内线性关系良好,定量限为1mg/kg;在饼干、巧克力和饮料3种空白基质中的平均回收率为88.50%~107.57%,相对标准偏差不高于6.08%,基质效应为89.77%~96.13%。该方法具有灵敏度高、特异性好的优势,可应用于饼干、巧克力、饮料等食品样品中松仁过敏原的检测,为我国食品标签真实性检验及食品中隐性过敏原的检测提供技术支持。展开更多
基金This work was supported by“National Key Research and Development Program of China”(Project No.2018YFC1603400)Science and Technology Program of Hebei Province(Project No.19225503D).
文摘The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish.
基金supported by the Robert A.Welch Foundation(Y0026)the French National Center for Scientific Research(ISA-CNRS-UMR5280)
文摘Current trends in chiral analysis of pharmaceutical drugs are focused on faster separations and higher separation efficiencies, Core-shell or superficially porous particles (SPP) based chiral stationary phases (CSPs) provide reduced analysis times while maintaining high column efficiencies and sensitivity. In this study, mobile phase conditions suitable for chiral analyses with electrospray ionization LC-MS were systematically investigated using vancomycin as a representative CSP. The performance of a 2.7 μm SPP based vancomycin CSP (SPP-V) 10 cm ×0.21 cm column was compared to that of a corresponding 5 μm fully porous particles based analogue column. The results demonstrated that the SPP-V column provides higher efficiencies, 2-5 time greater sensitivity and shorter analysis time for a set of 22 basic pharma- ceutical drugs. The SPP-V was successfully applied for the analysis of the degradation products of racemic citalopram whose enantiomers could be selectively identified by MS.
基金supported by the National Natural Science Foundation of China(No.41805105)。
文摘On-line chemical characterization of atmospheric particulate matter(PM)with soft ionization technique and ultrahigh-resolution Mass Spectrometry(UHRMS)provides molecular information of organic constituents in real time.Here we describe the development and application of an automatic measurement system that incorporates PM_(2.5)sampling,thermal desorption,atmospheric pressure photoionization,and UHRMS analysis.Molecular formulas of detected organic compounds were deducted from the accurate(±10 ppm)molecular weights obtained at a mass resolution of 100,000,allowing the identification of small organic compounds in PM_(2.5).Detection efficiencies of 28 standard compounds were determined and we found a high sensitivity and selectivity towards organic amines with limits of detection below 10 pg.As a proof of principle,PM_(2.5)samples collected off-line in winter in the urban area of Beijing were analyzed using the Ionization Module and HRMS of the system.The automatic system was then applied to conduct on-line measurements during the summer time at a time resolution of 2 hr.The detected organic compounds comprised mainly CHON and CHN compounds below 350 m/z.Pronounced seasonal variations in elemental composition were observed with shorter carbon backbones and higher O/C ratios in summer than that in winter.This result is consistent with stronger photochemical reactions and thus a higher oxidation state of organics in summer.Diurnal variation in signal intensity of each formula provides crucial information to reveal its source and formation pathway.In summary,the automatic measurement system serves as an important tool for the on-line characterization and identification of organic species in PM_(2.5).
基金supported by the National Key Research and Development Program of China(Grant No.:2018YFC0807402)the National Natural Science Foundation of China(Grant No.:82073810)。
文摘In this study,we developed a novel on-line solid phase extraction(SPE)-ultra-high-performance liquid chromatography tandem mass spectrometry(UHPLC-MS/MS)-based analytical method for simultaneously quantifying 12 illicit drugs and metabolites(methamphetamine,amphetamine,morphine,codeine,6-monoacetylmorphine,benzoylecgonine,3,4-methylenedioxymethamphetamine,3,4-methylenedioxyamphetamine,cocaine,ketamine,norketamine,and methcathinone)and cotinine(COT)in wastewater samples.The analysis was performed by loading 2 m L of the sample onto an Oasis hydrophilic-lipophilic balance cartridge and using a cleanup step(5%methanol)to eliminate interference with a total run time of 13 min.The isotope-labeled internal standard method was used to quantify the target substances and correct for unavoidable losses and matrix effects during the on-line SPE process.Typical analytical characteristics used for method validation were sensitivity,linearity,precision,repeatability,recovery,and matrix effects.The limit of detection(LOD)and limit of quantification(LOQ)of each target were set at 0.20 ng/L and 0.50 ng/L,respectively.The linearity was between 0.5 ng/L and250 ng/L,except for that of COT.The intra-and inter-day precisions were<10.45%and 25.64%,respectively,and the relative recovery ranged from 83.74%to 162.26%.The method was used to analyze various wastewater samples from 33 cities in China,and the results were compared with the experimental results of identical samples analyzed using off-line SPE.The difference rate was between 19.91%and-20.44%,and the error range could be considered acceptable.These findings showed that on-line SPE is a suitable alternative to off-line SPE for the analysis of illicit drugs in samples.
文摘基于食品基质中松仁过敏原Pin k 2建立了一种超高效液相色谱-串联质谱法。将松仁经过研磨、脱脂、浸提、酶解后经Easy-nLC 1000-QExactive高分辨质谱仪进行分离分析,结合Uniprot蛋白数据库以及ProteinPilotTM软件对质谱图进行数据处理,经BLAST验证特异性,最终筛选3条松仁特异性肽段。方法学验证结果表明,方法在0.001~50mg/mL范围内线性关系良好,定量限为1mg/kg;在饼干、巧克力和饮料3种空白基质中的平均回收率为88.50%~107.57%,相对标准偏差不高于6.08%,基质效应为89.77%~96.13%。该方法具有灵敏度高、特异性好的优势,可应用于饼干、巧克力、饮料等食品样品中松仁过敏原的检测,为我国食品标签真实性检验及食品中隐性过敏原的检测提供技术支持。