In distribution systems,voltage levels of the various buses should be maintained within the permissible limits for satisfactory operation of all electrical installations and equipment.The task of voltage control is cl...In distribution systems,voltage levels of the various buses should be maintained within the permissible limits for satisfactory operation of all electrical installations and equipment.The task of voltage control is closely associated with fluctuating load conditions and corresponding requirements of reactive power compensation.The problem of load bus voltage optimization in distribution systems that have distributed generation(DG)has recently become an issue.In Oman,the distribution code limits the load bus voltage variations within±6%of the nominal value.Several voltage control methods are employed in active distribution systems with a high share of photovoltaic systems(PV)to keep the voltage levels within the desirable limits.In addition to the constraint of targeting the best voltage profile,another constraint has to be achieved which is the minimum loss in the distribution network.An optimised solution for voltage of load busses with on-load tap-changing(OLTC)tarnsformers and PV sources is presented in this paper.This study addresses the problem of optimizing the injected power from PV systems associated with the facilities of tap-changing transformers,as it is an important means of controlling voltage throughout the system.To avoid violating tap-changing constraints,a method is depicted for determining the minimal changes in transformer taps to control voltage levels with distributed PV sources.The taps of a range+5 to-15%,can be achieved by tap-changing transformers.The OLTC operation was designed to keep the secondary bus within the voltage standard for MV networks.展开更多
At present, an automatic-mechanic contact tap-changer is widely used in power system, but it can not frequently operate. In addition, arc will occur when the switch changes. In order to solve these two problems, this ...At present, an automatic-mechanic contact tap-changer is widely used in power system, but it can not frequently operate. In addition, arc will occur when the switch changes. In order to solve these two problems, this paper presented an automatic on-load voltage-regulating distributing transformer which employed non-contact solid-state relay as tap-changer, and mainly introduced its structure, basic principal, design method of each key link and experimental results. Laboratory simulation experiments informed that the scheme was feasible. It was a smooth and effective experiment device, which was practical in application.展开更多
An accurate extraction of vibration signal characteristics of an on-load tap changer(OLTC)during contact switching can effectively help detect its abnormal state.Therefore,an improved fuzzy C-means clustering method f...An accurate extraction of vibration signal characteristics of an on-load tap changer(OLTC)during contact switching can effectively help detect its abnormal state.Therefore,an improved fuzzy C-means clustering method for abnormal state detection of the OLTC contact is proposed.First,the wavelet packet and singular spectrum analysis are used to denoise the vibration signal generated by the moving and static contacts of the OLTC.Then,the Hilbert-Huang transform that is optimized by the ensemble empirical mode decomposition(EEMD)is used to decompose the vibration signal and extract the boundary spectrum features.Finally,the gray wolf algorithm-based fuzzy C-means clustering is used to denoise the signal and determine the abnormal states of the OLTC contact.An analysis of the experimental data shows that the proposed secondary denoising method has a better denoising effect compared to the single denoising method.The EEMD can improve the modal aliasing effect,and the improved fuzzy C-means clustering can effectively identify the abnormal state of the OLTC contacts.The analysis results of field measured data further verify the effectiveness of the proposed method and provide a reference for the abnormal state detection of the OLTC.展开更多
文摘In distribution systems,voltage levels of the various buses should be maintained within the permissible limits for satisfactory operation of all electrical installations and equipment.The task of voltage control is closely associated with fluctuating load conditions and corresponding requirements of reactive power compensation.The problem of load bus voltage optimization in distribution systems that have distributed generation(DG)has recently become an issue.In Oman,the distribution code limits the load bus voltage variations within±6%of the nominal value.Several voltage control methods are employed in active distribution systems with a high share of photovoltaic systems(PV)to keep the voltage levels within the desirable limits.In addition to the constraint of targeting the best voltage profile,another constraint has to be achieved which is the minimum loss in the distribution network.An optimised solution for voltage of load busses with on-load tap-changing(OLTC)tarnsformers and PV sources is presented in this paper.This study addresses the problem of optimizing the injected power from PV systems associated with the facilities of tap-changing transformers,as it is an important means of controlling voltage throughout the system.To avoid violating tap-changing constraints,a method is depicted for determining the minimal changes in transformer taps to control voltage levels with distributed PV sources.The taps of a range+5 to-15%,can be achieved by tap-changing transformers.The OLTC operation was designed to keep the secondary bus within the voltage standard for MV networks.
文摘At present, an automatic-mechanic contact tap-changer is widely used in power system, but it can not frequently operate. In addition, arc will occur when the switch changes. In order to solve these two problems, this paper presented an automatic on-load voltage-regulating distributing transformer which employed non-contact solid-state relay as tap-changer, and mainly introduced its structure, basic principal, design method of each key link and experimental results. Laboratory simulation experiments informed that the scheme was feasible. It was a smooth and effective experiment device, which was practical in application.
文摘An accurate extraction of vibration signal characteristics of an on-load tap changer(OLTC)during contact switching can effectively help detect its abnormal state.Therefore,an improved fuzzy C-means clustering method for abnormal state detection of the OLTC contact is proposed.First,the wavelet packet and singular spectrum analysis are used to denoise the vibration signal generated by the moving and static contacts of the OLTC.Then,the Hilbert-Huang transform that is optimized by the ensemble empirical mode decomposition(EEMD)is used to decompose the vibration signal and extract the boundary spectrum features.Finally,the gray wolf algorithm-based fuzzy C-means clustering is used to denoise the signal and determine the abnormal states of the OLTC contact.An analysis of the experimental data shows that the proposed secondary denoising method has a better denoising effect compared to the single denoising method.The EEMD can improve the modal aliasing effect,and the improved fuzzy C-means clustering can effectively identify the abnormal state of the OLTC contacts.The analysis results of field measured data further verify the effectiveness of the proposed method and provide a reference for the abnormal state detection of the OLTC.