BACKGROUND Application of indocyanine green(ICG)fluorescence has led to new developments in gastrointestinal surgery.However,little is known about the use of ICG for the diagnosis of postoperative gut leakage(GL).In a...BACKGROUND Application of indocyanine green(ICG)fluorescence has led to new developments in gastrointestinal surgery.However,little is known about the use of ICG for the diagnosis of postoperative gut leakage(GL).In addition,there is a lack of rapid and intuitive methods to definitively diagnose postoperative GL.AIM To investigate the effect of ICG in the diagnosis of anastomotic leakage in a surgical rat GL model and evaluate its diagnostic value in colorectal surgery patients.METHODS Sixteen rats were divided into two groups:GL group(n=8)and sham group(n=8).Approximately 0.5 mL of ICG(2.5 mg/mL)was intravenously injected postoperatively.The peritoneal fluid was collected for the fluorescence test at 24 and 48 h.Six patients with rectal cancer who had undergone laparoscopic rectal cancer resection plus enterostomies were injected with 10 mL of ICG(2.5 mg/mL)on postoperative day 1.Their ostomy fluids were collected 24 h after ICG injection to identify the possibility of the ICG excreting from the peripheral veins to the enterostomy stoma.Participants who had undergone colectomy or rectal cancer resection were enrolled in the diagnostic test.The peritoneal fluids from drainage were collected 24 h after ICG injection.The ICG fluorescence test was conducted using OptoMedic endoscopy along with a near-infrared fluorescent imaging system.RESULTS The peritoneal fluids from the GL group showed ICG-dependent green fluorescence in contrast to the sham group.Six samples of ostomy fluids showed green fluorescence,indicating the possibility of ICG excreting from the peripheral veins to the enterostomy stoma in patients.The peritoneal fluid ICG test exhibited a sensitivity of 100%and a specificity of 83.3%for the diagnosis of GL.The positive predictive value was 71.4%,while the negative predictive value was 100%.The likelihood ratios were 6.0 for a positive test result and 0 for a negative result.CONCLUSION The postoperative ICG test in a drainage tube is a valuable and simple technique for the diagnosis of GL.Hence,it should be employed in clinical settings in patients with suspected GL.展开更多
AIM:To assess systematically the safety and efficacy of bile leakage test in liver resection.METHODS:Randomized controlled trials and controlled clinical trials involving the bile leakage test were included in a syste...AIM:To assess systematically the safety and efficacy of bile leakage test in liver resection.METHODS:Randomized controlled trials and controlled clinical trials involving the bile leakage test were included in a systematic literature search.Two authors independently assessed the studies for inclusion and extracted the data.A meta-analysis was conducted to estimate postoperative bile leakage,intraoperative positive bile leakage,and complications.We used either the fixed-effects or random-effects model.RESULTS:Eight studies involving a total of 1253 patients were included and they all involved the bile leakage test in liver resection.The bile leakage test group was associated with a significant reduction in bile leakage compared with the non-bile leakage test group(RR=0.39,95%CI:0.23-0.67;I2=3%).The white test had superiority for detection of intraoperative bile leakage compared with the saline solution test(RR=2.38,95%CI:1.24-4.56,P=0.009).No significant intergroup differences were observed in total number of complications,ileus,liver failure,intraperitoneal hemorrhage,pulmonary disorder,abdominal infection,and wound infection.CONCLUSION:The bile leakage test reduced postoperative bile leakage and did not increase incidence of complications.Fat emulsion is the best choice of solution for the test.展开更多
The magnetic field distribution characteristics of surface cracks with various widths are discussed based on finite element (FEM) results. The crack depth was 0.20 mm, the width range was from 0.02 to 1.00 mm. The res...The magnetic field distribution characteristics of surface cracks with various widths are discussed based on finite element (FEM) results. The crack depth was 0.20 mm, the width range was from 0.02 to 1.00 mm. The results showed that crack width and lift-off (the distance between surface and sensor) will influence signals. Discussed in this paper is the influence of various lift-off parameters on the peak to peak values of the normal component in magnetic flux leakage testing. The effects can be applied to evaluate surface breaking cracks of different widths and depths. An idea is presented to smooth narrow, sharp crack tips using alternating current (AC) field magnetization.展开更多
Magnetic flux leakage(MFL)testing technology has the advantages of simple principle,easy engineering implementation and low requirements on the surface of the detected workpiece.Therefore,it has been one of the resear...Magnetic flux leakage(MFL)testing technology has the advantages of simple principle,easy engineering implementation and low requirements on the surface of the detected workpiece.Therefore,it has been one of the research hotspots in the field of non-destructive testing(NDT)and widely used for testing long distance pipelines.This paper presents the development of MFL tesing technology from the aspects of basic theory,influencing factors,magnetization technology,signal processing,etc.The problems to be solved and the future development are summarized,which can provide reference for the research and system development of MFL testing technology.展开更多
In the leakage current test, through the high speed data collection and digital filtering to the output voltage of the human body impedance network, leakage current test that is in accordance with many kinds of electr...In the leakage current test, through the high speed data collection and digital filtering to the output voltage of the human body impedance network, leakage current test that is in accordance with many kinds of electrical safety standards can be realized, and the frequency distribution information of the leakage current can be got as well, which can be used to much more completely evaluate the possible damage degree of the leakage current to the human body and analyze the reason for the appearance of the leakage current in the electric equipment.展开更多
Difference processing was used to the direct current magnetic flux leakage (DC-MFL) signal, emanating from the defects machined artificially on the internal and external surfaces of a steel pipe. Consequently, the l...Difference processing was used to the direct current magnetic flux leakage (DC-MFL) signal, emanating from the defects machined artificially on the internal and external surfaces of a steel pipe. Consequently, the loea-tion discriminating index 8 was provided to identify the defect whether it is on the internal surface or the external one. Three characteristics, shape, depth and orientation of the defect, were discussed through a series of experiments on the artificial defects, such as transverse notches, oblique notches and pits on the steel pipe. The approach has been verified effective to address the defect location identifying problem, albeit the limits on the accuracy assessment to those natural defects on steel pipes in service.展开更多
In order to interpret the magnetic flux leakage (MFL) testing data quantitatively and size the defects accurately, some defect profiles inversion methods from the MFL signals are studied on the basis of the neural net...In order to interpret the magnetic flux leakage (MFL) testing data quantitatively and size the defects accurately, some defect profiles inversion methods from the MFL signals are studied on the basis of the neural network.Because the wavelet ba- sis function neural network (WBFNN) has good accuracy in the forward calculation and the radial basis function neural network (RBFNN) has reliable precision in the inversion modeling respectively,a new neural network scheme combining WBFNN and RBFNN is presented to solve the nonlinear inversion problem for the MFL data and reconstruct the defect shapes.And such details as the choice of wavelet basis function,the initialization of the weight value and the input normalization are analyzed,the train- ing and testing algorithm for the network are also studied.The inversion results demonstrate that the proposed network scheme has good reliability to interpret the MFL data for some defects.展开更多
Since the beginning of the 20th century, many researches on the sealing characteristic of mechanical seals were carried out broadly and in depth by various methods and some leakage models were built. But due to the la...Since the beginning of the 20th century, many researches on the sealing characteristic of mechanical seals were carried out broadly and in depth by various methods and some leakage models were built. But due to the lack of the way to characterize the main factors of influence on the leakage, most of the early researches were based on the assumptions that the seal faces topography and the frictional conditions were invariant. In the early built models, the effect of the surface topography change of the seal face on the leakage rate was neglected. Based on the fractal theory, the contact of end faces of the rotary and stationary rings was simplified to be the contact of a rough surface and an ideal rigid smooth surface, and the contact interface's cavity size-distribution function as well as the fractal characteristic of the cavity profile curve was discussed. By analyzing the influence of abrasion on the seal face topography and the leakage channel, the time-correlation leakage prediction model of mechanical seals based on the fractal theory was established and the method for predicting the leakage rate of mechanical seals with parallel plane was proposed. The values of the leakage rate predicted theoretically are similar to the measured values of the leakage rate in the model test and in situ test. The experimental results indicate that the leakage rate of mechanical seals is a transient value. The surface topography of the end faces of the seal tings and its change during the frictional wear of mechanical seals can be accurately characterized by the fractal parameters. Under the work conditions of changeless frictional mechanism, the fractal parameters measured or calculated based on the accelerated testing equation can be used to predict the leakage rate of mechanical seal in service. The proposed research provides the basis for determining the leakage state and predicting working life of mechanical seal.展开更多
As a promising non-destructive testing(NDT)method,magnetic flux leakage(MFL)testing has been widely used for steel structure inspection.However,MFL testing still faces a great challenge to detect inner defects.Existin...As a promising non-destructive testing(NDT)method,magnetic flux leakage(MFL)testing has been widely used for steel structure inspection.However,MFL testing still faces a great challenge to detect inner defects.Existing MFL course researches mainly focus on surface-breaking defects while that of inner defects is overlooked.In the paper,MFL course of inner defects is investigated by building magnetic circuit models,performing numerical simulations,and conducting MFL experiments.It is found that the near-surface wall has an enhancing effect on the MFL course due to higher permeability of steel than that of air.Further,a high-sensitivity MFL testing method consisting of Helmholtz coil magnetization and induction coil with a high permeability core is proposed to increase the detectable depth of inner defects.Experimental results show that inner defects with buried depth up to 80.0 mm can be detected,suggesting that the proposed MFL method has the potential to detect deeply-buried defects and has a promising future in the field of NDT.展开更多
Aiming at the detection of the sucker rod defects,a real-time detection system is designed using the non-destructive testing technology of magnetic flux leakage(MFL).An MFL measurement system consists of many parts,an...Aiming at the detection of the sucker rod defects,a real-time detection system is designed using the non-destructive testing technology of magnetic flux leakage(MFL).An MFL measurement system consists of many parts,and this study focuses on the signal acquisition and processing system.First of all,this paper introduces the hardware part of the acquisition system in detail,including the selection of the Hall-effect sensor,the design of the signal conditioning circuit,and the working process of the single chip computer(SCM)control serial port.Based on LabVIEW,a graphical programming software,the software part of the acquisition system is written,including serial port parameter configuration,detection signal recognition,original signal filtering,real-time display,data storage and playback.Finally,an experimental platform for the MFL detection is set up,and the MFL measurement is carried out on the transverse and longitudinal defects of the sucker rod surface.The experimental result shows that the designed acquisition and processing system has good detection performance,simple design and high flexibility.展开更多
Objective:The aim of this study was to measure the leakage by two methods with ion chamber and ready packs film,and to investigate the feasibility and the advantages of using two dosimetry methods for assessing leakag...Objective:The aim of this study was to measure the leakage by two methods with ion chamber and ready packs film,and to investigate the feasibility and the advantages of using two dosimetry methods for assessing leakage radiation around the head of the linear accelerators.Methods:Measurements were performed using a 30 cm3ion chamber;the gantry at 0°,the X-ray head at 0°,the field size at between the central axis and a plane surface at a FSD of 100 as a reference,a series of concentric circles having radii of 50,75,and 100 cm with their common centre at the reference point.The absorbed dose was measured at the reference point,and this would be used as the reference dose.With the diaphragm closed,the measurements were taken along the circumference of the three circles and at 45°intervals.Results:Leakage radiations while the treatment head was in the vertical position varied between 0.016%–0.04%.With the head lying horizontally,leakage radiation was the same order magnitude and varied between 0.02%–0.07%.In the second method,the verification was accomplished by closing the collimator jaws and covering the head of the treatment unit with the ready pack films.The films were marked to permit the determination of their positions on the machine after exposed and processed.With the diaphragm closed,and the ready packs films around the linear accelerator the beam turned on for 2500 cGy(2500 MU).The optical density of these films was measured and compared with this of the reference dose.Leakage radiation varied according to the film positions and the magnitude of leakage was between 0.005%–0.075%.Conclusion:The differences between the values of the leakage radiation levels observed at different measurement points do not only reflect differences in the effective shielding thickness of the head wall,but are also related to differences in the distances between the target and the measurement points.The experimental errors involved in dosimetric measurement also contribute to such differences.展开更多
A key issue, which influences the applications of magnetic flux leakage testing, is defect quantification. There have been many research on the relationship between width, depth and magnetic flux leakage of slot defec...A key issue, which influences the applications of magnetic flux leakage testing, is defect quantification. There have been many research on the relationship between width, depth and magnetic flux leakage of slot defect. However, the length factor is often ignored. The relationship between characteristics of defect leakage field and defect length was investigated. The magnetic flux leakages of a series of plate specimens with the same width, same depth and different length slot defects were tested under the same magnetizing conditions. Testing results show that defect length is an important parameter needed to consider in quantifying defects.展开更多
It is known that eddy current effect has a great influence on magnetic flux leakage testing(MFL).Usually,contacttype encoder wheels are used to measure MFL testing speed to evaluate the effect and further compensate t...It is known that eddy current effect has a great influence on magnetic flux leakage testing(MFL).Usually,contacttype encoder wheels are used to measure MFL testing speed to evaluate the effect and further compensate testing signals.This speed measurement method is complicated,and inevitable abrasion and occasional slippage will reduce the measurement accuracy.In order to solve this problem,based on eddy current effect due to the relative movement,a speed measurement method is proposed,which is contactless and simple.In the high-speed MFL testing,eddy current induced in the specimen will cause an obvious modification to the applied field.This modified field,which is measured by Hall sensor,can be utilized to reflect the moving speed.Firstly,the measurement principle is illustrated based on Faraday’s law.Then,dynamic finite element simulations are conducted to investigate the modified magnetic field distribution.Finally,laboratory experiments are performed to validate the feasibility of the proposed method.The results show that Bmz(r1)and Bmx(r2)have a linear relation with moving speed,which could be used as an alternative measurement parameter.展开更多
基金Supported by the Science and Technology Projects in Guangzhou,No.202201010623 and No.2024A03J1016Guangzhou Science and Technology Project of Traditional Chinese Medicine and Combined Chinese and Western Medicine,No.20242A011001Guangdong Medical Science and Research Foundation,No.A2024088.
文摘BACKGROUND Application of indocyanine green(ICG)fluorescence has led to new developments in gastrointestinal surgery.However,little is known about the use of ICG for the diagnosis of postoperative gut leakage(GL).In addition,there is a lack of rapid and intuitive methods to definitively diagnose postoperative GL.AIM To investigate the effect of ICG in the diagnosis of anastomotic leakage in a surgical rat GL model and evaluate its diagnostic value in colorectal surgery patients.METHODS Sixteen rats were divided into two groups:GL group(n=8)and sham group(n=8).Approximately 0.5 mL of ICG(2.5 mg/mL)was intravenously injected postoperatively.The peritoneal fluid was collected for the fluorescence test at 24 and 48 h.Six patients with rectal cancer who had undergone laparoscopic rectal cancer resection plus enterostomies were injected with 10 mL of ICG(2.5 mg/mL)on postoperative day 1.Their ostomy fluids were collected 24 h after ICG injection to identify the possibility of the ICG excreting from the peripheral veins to the enterostomy stoma.Participants who had undergone colectomy or rectal cancer resection were enrolled in the diagnostic test.The peritoneal fluids from drainage were collected 24 h after ICG injection.The ICG fluorescence test was conducted using OptoMedic endoscopy along with a near-infrared fluorescent imaging system.RESULTS The peritoneal fluids from the GL group showed ICG-dependent green fluorescence in contrast to the sham group.Six samples of ostomy fluids showed green fluorescence,indicating the possibility of ICG excreting from the peripheral veins to the enterostomy stoma in patients.The peritoneal fluid ICG test exhibited a sensitivity of 100%and a specificity of 83.3%for the diagnosis of GL.The positive predictive value was 71.4%,while the negative predictive value was 100%.The likelihood ratios were 6.0 for a positive test result and 0 for a negative result.CONCLUSION The postoperative ICG test in a drainage tube is a valuable and simple technique for the diagnosis of GL.Hence,it should be employed in clinical settings in patients with suspected GL.
基金Supported by National Science and Technology Major Project of ChinaNo.2012ZX10002-016 and No.2012ZX10002-017
文摘AIM:To assess systematically the safety and efficacy of bile leakage test in liver resection.METHODS:Randomized controlled trials and controlled clinical trials involving the bile leakage test were included in a systematic literature search.Two authors independently assessed the studies for inclusion and extracted the data.A meta-analysis was conducted to estimate postoperative bile leakage,intraoperative positive bile leakage,and complications.We used either the fixed-effects or random-effects model.RESULTS:Eight studies involving a total of 1253 patients were included and they all involved the bile leakage test in liver resection.The bile leakage test group was associated with a significant reduction in bile leakage compared with the non-bile leakage test group(RR=0.39,95%CI:0.23-0.67;I2=3%).The white test had superiority for detection of intraoperative bile leakage compared with the saline solution test(RR=2.38,95%CI:1.24-4.56,P=0.009).No significant intergroup differences were observed in total number of complications,ileus,liver failure,intraperitoneal hemorrhage,pulmonary disorder,abdominal infection,and wound infection.CONCLUSION:The bile leakage test reduced postoperative bile leakage and did not increase incidence of complications.Fat emulsion is the best choice of solution for the test.
基金This work was sponsored by the National Natural Science Foundation of China (Grant No.50001006).
文摘The magnetic field distribution characteristics of surface cracks with various widths are discussed based on finite element (FEM) results. The crack depth was 0.20 mm, the width range was from 0.02 to 1.00 mm. The results showed that crack width and lift-off (the distance between surface and sensor) will influence signals. Discussed in this paper is the influence of various lift-off parameters on the peak to peak values of the normal component in magnetic flux leakage testing. The effects can be applied to evaluate surface breaking cracks of different widths and depths. An idea is presented to smooth narrow, sharp crack tips using alternating current (AC) field magnetization.
基金National Natural Science Foundation of China(No.51804267)Applied Basic Research Project of Sichuan Province(No.2017JY0162)。
文摘Magnetic flux leakage(MFL)testing technology has the advantages of simple principle,easy engineering implementation and low requirements on the surface of the detected workpiece.Therefore,it has been one of the research hotspots in the field of non-destructive testing(NDT)and widely used for testing long distance pipelines.This paper presents the development of MFL tesing technology from the aspects of basic theory,influencing factors,magnetization technology,signal processing,etc.The problems to be solved and the future development are summarized,which can provide reference for the research and system development of MFL testing technology.
文摘In the leakage current test, through the high speed data collection and digital filtering to the output voltage of the human body impedance network, leakage current test that is in accordance with many kinds of electrical safety standards can be realized, and the frequency distribution information of the leakage current can be got as well, which can be used to much more completely evaluate the possible damage degree of the leakage current to the human body and analyze the reason for the appearance of the leakage current in the electric equipment.
基金supported by the National Natural Science Foundation of China under Grant No.50675083
文摘Difference processing was used to the direct current magnetic flux leakage (DC-MFL) signal, emanating from the defects machined artificially on the internal and external surfaces of a steel pipe. Consequently, the loea-tion discriminating index 8 was provided to identify the defect whether it is on the internal surface or the external one. Three characteristics, shape, depth and orientation of the defect, were discussed through a series of experiments on the artificial defects, such as transverse notches, oblique notches and pits on the steel pipe. The approach has been verified effective to address the defect location identifying problem, albeit the limits on the accuracy assessment to those natural defects on steel pipes in service.
基金Funded by National Natural Science Foundation of China(50305017)the Youth Chengguang Project of Science and Technology of Wuhan City of China(20045006071-27).
文摘In order to interpret the magnetic flux leakage (MFL) testing data quantitatively and size the defects accurately, some defect profiles inversion methods from the MFL signals are studied on the basis of the neural network.Because the wavelet ba- sis function neural network (WBFNN) has good accuracy in the forward calculation and the radial basis function neural network (RBFNN) has reliable precision in the inversion modeling respectively,a new neural network scheme combining WBFNN and RBFNN is presented to solve the nonlinear inversion problem for the MFL data and reconstruct the defect shapes.And such details as the choice of wavelet basis function,the initialization of the weight value and the input normalization are analyzed,the train- ing and testing algorithm for the network are also studied.The inversion results demonstrate that the proposed network scheme has good reliability to interpret the MFL data for some defects.
基金supported by China Postdoctoral Science Foundation (Grant No. 20070410323)Jiangsu Provincial Planned Projects for Postdoctoral Research Funds of China (Grant No. 0701001C)Jiangsu Provincial Planned Projects for Fostering Talents of Six Scientific Fields of China (Grant No. 07-D-027)
文摘Since the beginning of the 20th century, many researches on the sealing characteristic of mechanical seals were carried out broadly and in depth by various methods and some leakage models were built. But due to the lack of the way to characterize the main factors of influence on the leakage, most of the early researches were based on the assumptions that the seal faces topography and the frictional conditions were invariant. In the early built models, the effect of the surface topography change of the seal face on the leakage rate was neglected. Based on the fractal theory, the contact of end faces of the rotary and stationary rings was simplified to be the contact of a rough surface and an ideal rigid smooth surface, and the contact interface's cavity size-distribution function as well as the fractal characteristic of the cavity profile curve was discussed. By analyzing the influence of abrasion on the seal face topography and the leakage channel, the time-correlation leakage prediction model of mechanical seals based on the fractal theory was established and the method for predicting the leakage rate of mechanical seals with parallel plane was proposed. The values of the leakage rate predicted theoretically are similar to the measured values of the leakage rate in the model test and in situ test. The experimental results indicate that the leakage rate of mechanical seals is a transient value. The surface topography of the end faces of the seal tings and its change during the frictional wear of mechanical seals can be accurately characterized by the fractal parameters. Under the work conditions of changeless frictional mechanism, the fractal parameters measured or calculated based on the accelerated testing equation can be used to predict the leakage rate of mechanical seal in service. The proposed research provides the basis for determining the leakage state and predicting working life of mechanical seal.
基金Supported by National Natural Science Foundation of China(Grant Nos.51907131,92060114)Sichuan Science and Technology Program(Grant Nos.2020YFG0090,2021YFG0039,2020ZDZX0024).
文摘As a promising non-destructive testing(NDT)method,magnetic flux leakage(MFL)testing has been widely used for steel structure inspection.However,MFL testing still faces a great challenge to detect inner defects.Existing MFL course researches mainly focus on surface-breaking defects while that of inner defects is overlooked.In the paper,MFL course of inner defects is investigated by building magnetic circuit models,performing numerical simulations,and conducting MFL experiments.It is found that the near-surface wall has an enhancing effect on the MFL course due to higher permeability of steel than that of air.Further,a high-sensitivity MFL testing method consisting of Helmholtz coil magnetization and induction coil with a high permeability core is proposed to increase the detectable depth of inner defects.Experimental results show that inner defects with buried depth up to 80.0 mm can be detected,suggesting that the proposed MFL method has the potential to detect deeply-buried defects and has a promising future in the field of NDT.
文摘Aiming at the detection of the sucker rod defects,a real-time detection system is designed using the non-destructive testing technology of magnetic flux leakage(MFL).An MFL measurement system consists of many parts,and this study focuses on the signal acquisition and processing system.First of all,this paper introduces the hardware part of the acquisition system in detail,including the selection of the Hall-effect sensor,the design of the signal conditioning circuit,and the working process of the single chip computer(SCM)control serial port.Based on LabVIEW,a graphical programming software,the software part of the acquisition system is written,including serial port parameter configuration,detection signal recognition,original signal filtering,real-time display,data storage and playback.Finally,an experimental platform for the MFL detection is set up,and the MFL measurement is carried out on the transverse and longitudinal defects of the sucker rod surface.The experimental result shows that the designed acquisition and processing system has good detection performance,simple design and high flexibility.
文摘Objective:The aim of this study was to measure the leakage by two methods with ion chamber and ready packs film,and to investigate the feasibility and the advantages of using two dosimetry methods for assessing leakage radiation around the head of the linear accelerators.Methods:Measurements were performed using a 30 cm3ion chamber;the gantry at 0°,the X-ray head at 0°,the field size at between the central axis and a plane surface at a FSD of 100 as a reference,a series of concentric circles having radii of 50,75,and 100 cm with their common centre at the reference point.The absorbed dose was measured at the reference point,and this would be used as the reference dose.With the diaphragm closed,the measurements were taken along the circumference of the three circles and at 45°intervals.Results:Leakage radiations while the treatment head was in the vertical position varied between 0.016%–0.04%.With the head lying horizontally,leakage radiation was the same order magnitude and varied between 0.02%–0.07%.In the second method,the verification was accomplished by closing the collimator jaws and covering the head of the treatment unit with the ready pack films.The films were marked to permit the determination of their positions on the machine after exposed and processed.With the diaphragm closed,and the ready packs films around the linear accelerator the beam turned on for 2500 cGy(2500 MU).The optical density of these films was measured and compared with this of the reference dose.Leakage radiation varied according to the film positions and the magnitude of leakage was between 0.005%–0.075%.Conclusion:The differences between the values of the leakage radiation levels observed at different measurement points do not only reflect differences in the effective shielding thickness of the head wall,but are also related to differences in the distances between the target and the measurement points.The experimental errors involved in dosimetric measurement also contribute to such differences.
基金This work was financially supported by the National Natural Science Foundation of China(Grant No.50001006,50305017)China Postdoctoral Science Foundation.
文摘A key issue, which influences the applications of magnetic flux leakage testing, is defect quantification. There have been many research on the relationship between width, depth and magnetic flux leakage of slot defect. However, the length factor is often ignored. The relationship between characteristics of defect leakage field and defect length was investigated. The magnetic flux leakages of a series of plate specimens with the same width, same depth and different length slot defects were tested under the same magnetizing conditions. Testing results show that defect length is an important parameter needed to consider in quantifying defects.
基金supported in part by the National Natural Science Foundation of China(Grant No.92060114)in part by the Sichuan Science and Technology Program(Nos.2022YFS0524 and 2022YFG0044).
文摘It is known that eddy current effect has a great influence on magnetic flux leakage testing(MFL).Usually,contacttype encoder wheels are used to measure MFL testing speed to evaluate the effect and further compensate testing signals.This speed measurement method is complicated,and inevitable abrasion and occasional slippage will reduce the measurement accuracy.In order to solve this problem,based on eddy current effect due to the relative movement,a speed measurement method is proposed,which is contactless and simple.In the high-speed MFL testing,eddy current induced in the specimen will cause an obvious modification to the applied field.This modified field,which is measured by Hall sensor,can be utilized to reflect the moving speed.Firstly,the measurement principle is illustrated based on Faraday’s law.Then,dynamic finite element simulations are conducted to investigate the modified magnetic field distribution.Finally,laboratory experiments are performed to validate the feasibility of the proposed method.The results show that Bmz(r1)and Bmx(r2)have a linear relation with moving speed,which could be used as an alternative measurement parameter.