A maximal photon number entangled state,namely NOON state,can be adopted for sensing with a quantum enhancedprecision.In this work,we designed silicon quantum photonic chips containing two types of Mach-Zehnder interf...A maximal photon number entangled state,namely NOON state,can be adopted for sensing with a quantum enhancedprecision.In this work,we designed silicon quantum photonic chips containing two types of Mach-Zehnder interferometerswherein the two-photon NOON state,sensing element for temperature or humidity,is generated.Compared with classicallight or single photon case,two-photon NOON state sensing shows a solid enhancement in the sensing resolution andprecision.As the first demonstration of on-chip quantum photonic sensing,it reveals the advantages of photonic chips forhigh integration density,small-size,stability for multiple-parameter sensing serviceability.A higher sensing precision isexpected to beat the standard quantum limit with a higher photon number NOON state.展开更多
It is still challenging to fully integrate computing in memory chip as edge learning devices.In recent work published on Science,a fully-integrated chip based on neuromorphic memristors was developed for edge learning...It is still challenging to fully integrate computing in memory chip as edge learning devices.In recent work published on Science,a fully-integrated chip based on neuromorphic memristors was developed for edge learning as artificial neural networks with functionality of synapses,dendrites,and somas.A crossbar-array memristor chip facilitated edge learning including hardware realization,learning algorithm,and cycle-parallel sign-and threshold-based learning(STELLAR)scheme.The motion control and demonstration platforms were executed to improve the edge learning ability for adapting to new scenarios.展开更多
Copper-based azide(Cu(N_(3))2 or CuN_(3),CA)chips synthesized by in-situ azide reaction and utilized in miniaturized explosive systems has become a hot research topic in recent years.However,the advantages of in-situ ...Copper-based azide(Cu(N_(3))2 or CuN_(3),CA)chips synthesized by in-situ azide reaction and utilized in miniaturized explosive systems has become a hot research topic in recent years.However,the advantages of in-situ synthesis method,including small size and low dosage,bring about difficulties in quantitative analysis and differences in ignition capabilities of CA chips.The aim of present work is to develop a simplified quantitative analysis method for accurate and safe analysis of components in CA chips to evaluate and investigate the corresponding ignition ability.In this work,Cu(N_(3))2 and CuN_(3)components in CA chips were separated through dissolution and distillation by utilizing the difference in solubility and corresponding content was obtained by measuring N_(3)-concentration through spectrophotometry.The spectrophotometry method was optimized by studying influencing factors and the recovery rate of different separation methods was studied,ensuring the accuracy and reproducibility of test results.The optimized method is linear in range from 1.0-25.0 mg/L,with a correlation coefficient R^(2)=0.9998,which meets the requirements of CA chips with a milligram-level content test.Compared with the existing ICP method,component analysis results of CA chips obtained by spectrophotometry are closer to real component content in samples and have satisfactory accuracy.Moreover,as its application in miniaturized explosive systems,the ignition ability of CA chips with different component contents for direct ink writing CL-20 and the corresponding mechanism was studied.This study provided a basis and idea for the design and performance evaluation of CA chips in miniaturized explosive systems.展开更多
On-demand droplet sorting is extensively applied for the efficient manipulation and genome-wide analysis of individual cells.However,state-of-the-art microfluidic chips for droplet sorting still suffer from low sortin...On-demand droplet sorting is extensively applied for the efficient manipulation and genome-wide analysis of individual cells.However,state-of-the-art microfluidic chips for droplet sorting still suffer from low sorting speeds,sample loss,and labor-intensive preparation procedures.Here,we demonstrate the development of a novel microfluidic chip that integrates droplet generation,on-demand electrostatic droplet charging,and high-throughput sorting.The charging electrode is a copper wire buried above the nozzle of the microchannel,and the deflecting electrode is the phosphate buffered saline in the microchannel,which greatly simplifies the structure and fabrication process of the chip.Moreover,this chip is capable of high-frequency droplet generation and sorting,with a frequency of 11.757 kHz in the drop state.The chip completes the selective charging process via electrostatic induction during droplet generation.On-demand charged microdroplets can arbitrarilymove to specific exit channels in a three-dimensional(3D)-deflected electric field,which can be controlled according to user requirements,and the flux of droplet deflection is thereby significantly enhanced.Furthermore,a lossless modification strategy is presented to improve the accuracy of droplet deflection or harvest rate from 97.49% to 99.38% by monitoring the frequency of droplet generation in real time and feeding it back to the charging signal.This chip has great potential for quantitative processing and analysis of single cells for elucidating cell-to-cell variations.展开更多
Paper-based microchips have different advantages,such as better biocompatibility,simple production,and easy handling,making them promising candidates for clinical diagnosis and other fields.This study describes ametho...Paper-based microchips have different advantages,such as better biocompatibility,simple production,and easy handling,making them promising candidates for clinical diagnosis and other fields.This study describes amethod developed to fabricate modular three-dimensional(3D)paper-based microfluidic chips based on projection-based 3D printing(PBP)technology.A series of two-dimensional(2D)paper-based microfluidic modules was designed and fabricated.After evaluating the effect of exposure time on the accuracy of the flow channel,the resolution of this channel was experimentally analyzed.Furthermore,several 3D paper-based microfluidic chips were assembled based on the 2D ones using different methods,with good channel connectivity.Scaffold-based 2D and hydrogel-based 3D cell culture systems based on 3D paper-based microfluidic chips were verified to be feasible.Furthermore,by combining extrusion 3D bioprinting technology and the proposed 3D paper-based microfluidic chips,multiorgan microfluidic chips were established by directly printing 3D hydrogel structures on 3D paperbased microfluidic chips,confirming that the prepared modular 3D paper-based microfluidic chip is potentially applicable in various biomedical applications.展开更多
In recent years,space-division multiplexing(SDM)technology,which involves transmitting data information on multiple parallel channels for efficient capacity scaling,has been widely used in fiber and free-space optical...In recent years,space-division multiplexing(SDM)technology,which involves transmitting data information on multiple parallel channels for efficient capacity scaling,has been widely used in fiber and free-space optical communication sys-tems.To enable flexible data management and cope with the mixing between different channels,the integrated reconfig-urable optical processor is used for optical switching and mitigating the channel crosstalk.However,efficient online train-ing becomes intricate and challenging,particularly when dealing with a significant number of channels.Here we use the stochastic parallel gradient descent(SPGD)algorithm to configure the integrated optical processor,which has less com-putation than the traditional gradient descent(GD)algorithm.We design and fabricate a 6×6 on-chip optical processor on silicon platform to implement optical switching and descrambling assisted by the online training with the SPDG algorithm.Moreover,we apply the on-chip processor configured by the SPGD algorithm to optical communications for optical switching and efficiently mitigating the channel crosstalk in SDM systems.In comparison with the traditional GD al-gorithm,it is found that the SPGD algorithm features better performance especially when the scale of matrix is large,which means it has the potential to optimize large-scale optical matrix computation acceleration chips.展开更多
Sensitive detection and precise quantitation of trace-level crucial biomarkers in a complex sample matrix has become an important area of research.For example,the detection of high-sensitivity cardiac troponin I (hs-c...Sensitive detection and precise quantitation of trace-level crucial biomarkers in a complex sample matrix has become an important area of research.For example,the detection of high-sensitivity cardiac troponin I (hs-cTnI) is strongly recommended in clinical guidelines for early diagnosis of acute myocardial infarction.Based on the use of an electrode modified by single-walled carbon nanotubes (SWCNTs) and a Ru(bpy)32+-doped silica nanoparticle (Ru@SiO2)/tripropylamine (TPA) system,a novel type of electrochemiluminescent (ECL) magnetoimmunosensor is developed for ultrasensitive detection of hs-cTnI.In this approach,a large amount of[Ru(bpy)3]2+is loaded in SiO2(silica nanoparticles) as luminophores with high luminescent efficiency and SWCNTs as electrode surface modification material with excellent electrooxidation ability for TPA.Subsequently,a hierarchical micropillar array of microstructures is fabricated with a magnet placed at each end to efficiently confine a single layer of immunomagnetic microbeads on the surface of the electrode and enable 7.5-fold signal enhancement In particular,the use of transparent SWCNTs to modify a transparent ITO electrode provides a two-order-of-magnitude ECL signal amplification.A good linear calibration curve is developed for hs-cTnI concentrations over a wide range from 10 fg/ml to 10 ng/ml,with the limit of detection calculated as 8.720 fg/ml (S/N=3).This ultrasensitive immunosensor exhibits superior detection performance with remarkable stability,reproducibility,and selectivity.Satisfactory recoveries are obtained in the detection of hs-cTnI in human serum,providing a potentia analysis protocol for clinical applications.展开更多
目的:分析骨髓增殖性肿瘤(MPN)患者不确定潜能的克隆性造血(CHIP)相关基因突变谱和临床特征,探讨CHIP相关基因与其心脑血管事件(CCE)的相关性及可能作用机制。方法:回顾性分析2019年8月-2022年7月首都医科大学附属北京安贞医院血液科收...目的:分析骨髓增殖性肿瘤(MPN)患者不确定潜能的克隆性造血(CHIP)相关基因突变谱和临床特征,探讨CHIP相关基因与其心脑血管事件(CCE)的相关性及可能作用机制。方法:回顾性分析2019年8月-2022年7月首都医科大学附属北京安贞医院血液科收治的73例MPN患者的临床资料和二代测序结果,采用Logistic回归分析CHIP相关基因、炎症细胞因子对MPN患者CCE的影响。结果:55例(75.3%)MPN患者检出CHIP相关基因,原发性血小板增多症(ET)和真性红细胞增多症(PV)患者CHIP相关基因各突变频率差异无统计学意义。CHIP相关基因突变以单基因形式为主,检出率从高至低依次为JAK2V617F(63.0%,46/73)、ASXL1(16.4%,12/73)、TET2(11.0%,8/73)、DNMT3A(9.6%,7/73)、SRSF2(6.9%,5/73)、SF3B1(4.1%,3/73)、TP53(1.4%,1/73)和PPMID(1.4%,1/73)。年龄>60岁患者CHIP相关基因检出率明显高于≤60岁者[91.7%(33/36)vs 59.5%(22/37)]。27例(37.0%)MPN患者伴CCE(MPN/CCE),2次CCE者5例,均为动脉事件。CCE组患者年龄(62.8±12.8 vs 53.9±15.8岁,P=0.015)、IL-1β水平(17.7±26.0vs 4.3±8.6,P=0.012)、IL-8水平(360.7±598.6 vs 108.3±317.0,P=0.045)、血栓形成史(29.6%vs 2.2%,P=0.020)和CHIP相关基因检出率(88.9%vs 67.4%,P=0.040)高于无CCE组。多因素Logistic回归分析结果显示,年龄(OR=0.917,95%CI:0.843-0.999,P=0.047)、血栓形成史(OR=34.148,95%CI:2.392-487.535,P=0.009)、任何1个CHIP相关基因突变(OR=16.065,95%CI:1.217-212.024,P=0.035)和IL-1β水平升高(OR=0.929,95%CI:0.870-0.992,P=0.027)均是MPN/CCE的独立危险因素;CHIP相关单基因突变与MPN/CCE无关,但DNMT3A(OR=88.717,95%CI:2.690-292.482,P=0.012)、ASXL1(OR=7.941,95%CI:1.045-60.353,P=0.045)突变是PV/CCE的独立危险因素。结论:MPN患者CHIP相关基因突变率高,尤其是60岁以上患者;高龄、血栓形成史、CHIP相关基因突变和IL-1β水平升高是MPN发生CCE的独立危险因素。DNMT3A、ASXL1单基因突变是PV患者CCE的独立危险因素。CHIP相关基因突变及炎症细胞因子IL-1β升高是MPN新的CCE危险因素。展开更多
基金supported by the National Key R&D Program of China(Grant No.2022YFF0712800)Innova-tion Program for Quantum Science and Technology(Grant No.2021ZD0301500).
文摘A maximal photon number entangled state,namely NOON state,can be adopted for sensing with a quantum enhancedprecision.In this work,we designed silicon quantum photonic chips containing two types of Mach-Zehnder interferometerswherein the two-photon NOON state,sensing element for temperature or humidity,is generated.Compared with classicallight or single photon case,two-photon NOON state sensing shows a solid enhancement in the sensing resolution andprecision.As the first demonstration of on-chip quantum photonic sensing,it reveals the advantages of photonic chips forhigh integration density,small-size,stability for multiple-parameter sensing serviceability.A higher sensing precision isexpected to beat the standard quantum limit with a higher photon number NOON state.
基金funding support from the National Natural Science Foundation of China(52172205).
文摘It is still challenging to fully integrate computing in memory chip as edge learning devices.In recent work published on Science,a fully-integrated chip based on neuromorphic memristors was developed for edge learning as artificial neural networks with functionality of synapses,dendrites,and somas.A crossbar-array memristor chip facilitated edge learning including hardware realization,learning algorithm,and cycle-parallel sign-and threshold-based learning(STELLAR)scheme.The motion control and demonstration platforms were executed to improve the edge learning ability for adapting to new scenarios.
基金the financial support provided by the National Natural Science Foundation of China(Grant No.11872013).
文摘Copper-based azide(Cu(N_(3))2 or CuN_(3),CA)chips synthesized by in-situ azide reaction and utilized in miniaturized explosive systems has become a hot research topic in recent years.However,the advantages of in-situ synthesis method,including small size and low dosage,bring about difficulties in quantitative analysis and differences in ignition capabilities of CA chips.The aim of present work is to develop a simplified quantitative analysis method for accurate and safe analysis of components in CA chips to evaluate and investigate the corresponding ignition ability.In this work,Cu(N_(3))2 and CuN_(3)components in CA chips were separated through dissolution and distillation by utilizing the difference in solubility and corresponding content was obtained by measuring N_(3)-concentration through spectrophotometry.The spectrophotometry method was optimized by studying influencing factors and the recovery rate of different separation methods was studied,ensuring the accuracy and reproducibility of test results.The optimized method is linear in range from 1.0-25.0 mg/L,with a correlation coefficient R^(2)=0.9998,which meets the requirements of CA chips with a milligram-level content test.Compared with the existing ICP method,component analysis results of CA chips obtained by spectrophotometry are closer to real component content in samples and have satisfactory accuracy.Moreover,as its application in miniaturized explosive systems,the ignition ability of CA chips with different component contents for direct ink writing CL-20 and the corresponding mechanism was studied.This study provided a basis and idea for the design and performance evaluation of CA chips in miniaturized explosive systems.
基金The authors acknowledge the financial support from the NationalNatural Science Foundation ofChina(No.52275562)the Technology Innovation Fund of Huazhong University of Science and Technology(No.2022JYCXJJ015).
文摘On-demand droplet sorting is extensively applied for the efficient manipulation and genome-wide analysis of individual cells.However,state-of-the-art microfluidic chips for droplet sorting still suffer from low sorting speeds,sample loss,and labor-intensive preparation procedures.Here,we demonstrate the development of a novel microfluidic chip that integrates droplet generation,on-demand electrostatic droplet charging,and high-throughput sorting.The charging electrode is a copper wire buried above the nozzle of the microchannel,and the deflecting electrode is the phosphate buffered saline in the microchannel,which greatly simplifies the structure and fabrication process of the chip.Moreover,this chip is capable of high-frequency droplet generation and sorting,with a frequency of 11.757 kHz in the drop state.The chip completes the selective charging process via electrostatic induction during droplet generation.On-demand charged microdroplets can arbitrarilymove to specific exit channels in a three-dimensional(3D)-deflected electric field,which can be controlled according to user requirements,and the flux of droplet deflection is thereby significantly enhanced.Furthermore,a lossless modification strategy is presented to improve the accuracy of droplet deflection or harvest rate from 97.49% to 99.38% by monitoring the frequency of droplet generation in real time and feeding it back to the charging signal.This chip has great potential for quantitative processing and analysis of single cells for elucidating cell-to-cell variations.
基金sponsored by the National Natural Science Foundation of China(No.52235007,YH)the Science Fund for Creative Research Groups of the National Natural Science Foundation of China(No.T2121004,YH)+3 种基金the NationalNatural Science Foundation of China(No.52305300,MJX)the Fellowship of China Postdoctoral Science Foundation(No.2022M722826,MJX)the National Natural Science Foundation of China(No.82203602,JW)the Zhejiang Provincial Natural Science Foundation of China(No.LQ22H160020,JW)。
文摘Paper-based microchips have different advantages,such as better biocompatibility,simple production,and easy handling,making them promising candidates for clinical diagnosis and other fields.This study describes amethod developed to fabricate modular three-dimensional(3D)paper-based microfluidic chips based on projection-based 3D printing(PBP)technology.A series of two-dimensional(2D)paper-based microfluidic modules was designed and fabricated.After evaluating the effect of exposure time on the accuracy of the flow channel,the resolution of this channel was experimentally analyzed.Furthermore,several 3D paper-based microfluidic chips were assembled based on the 2D ones using different methods,with good channel connectivity.Scaffold-based 2D and hydrogel-based 3D cell culture systems based on 3D paper-based microfluidic chips were verified to be feasible.Furthermore,by combining extrusion 3D bioprinting technology and the proposed 3D paper-based microfluidic chips,multiorgan microfluidic chips were established by directly printing 3D hydrogel structures on 3D paperbased microfluidic chips,confirming that the prepared modular 3D paper-based microfluidic chip is potentially applicable in various biomedical applications.
基金supported by the National Natural Science Foundation of China(NSFC)(62125503,62261160388)the Natural Science Foundation of Hubei Province of China(2023AFA028)the Innovation Project of Optics Valley Laboratory(OVL2021BG004).
文摘In recent years,space-division multiplexing(SDM)technology,which involves transmitting data information on multiple parallel channels for efficient capacity scaling,has been widely used in fiber and free-space optical communication sys-tems.To enable flexible data management and cope with the mixing between different channels,the integrated reconfig-urable optical processor is used for optical switching and mitigating the channel crosstalk.However,efficient online train-ing becomes intricate and challenging,particularly when dealing with a significant number of channels.Here we use the stochastic parallel gradient descent(SPGD)algorithm to configure the integrated optical processor,which has less com-putation than the traditional gradient descent(GD)algorithm.We design and fabricate a 6×6 on-chip optical processor on silicon platform to implement optical switching and descrambling assisted by the online training with the SPDG algorithm.Moreover,we apply the on-chip processor configured by the SPGD algorithm to optical communications for optical switching and efficiently mitigating the channel crosstalk in SDM systems.In comparison with the traditional GD al-gorithm,it is found that the SPGD algorithm features better performance especially when the scale of matrix is large,which means it has the potential to optimize large-scale optical matrix computation acceleration chips.
基金The authors acknowledge financial support from the National Natural Science Foundation of China(Grant Nos.62001460,31971368,12202461,and 22104148)the Guangdong Regional Joint Funds for Young Scientists(Grant Nos.2020A1515110201 and 2020A1515110368)+2 种基金Guangdong Provincial General Funding(Grant No.2021A1515220156)Guangdong Basic and Applied Basic Research Funding-Regional Joint Fund(Grant No.2020B1515120040)Shenzhen Science and Technology Research Funding(Grant Nos.JSGG20201103153801005,JSGG20191115141601721,ZDSYS20220527171406014,JCYJ20220818101412027,JCYJ20200109115635440,and JCYJ 20200109115408041).
文摘Sensitive detection and precise quantitation of trace-level crucial biomarkers in a complex sample matrix has become an important area of research.For example,the detection of high-sensitivity cardiac troponin I (hs-cTnI) is strongly recommended in clinical guidelines for early diagnosis of acute myocardial infarction.Based on the use of an electrode modified by single-walled carbon nanotubes (SWCNTs) and a Ru(bpy)32+-doped silica nanoparticle (Ru@SiO2)/tripropylamine (TPA) system,a novel type of electrochemiluminescent (ECL) magnetoimmunosensor is developed for ultrasensitive detection of hs-cTnI.In this approach,a large amount of[Ru(bpy)3]2+is loaded in SiO2(silica nanoparticles) as luminophores with high luminescent efficiency and SWCNTs as electrode surface modification material with excellent electrooxidation ability for TPA.Subsequently,a hierarchical micropillar array of microstructures is fabricated with a magnet placed at each end to efficiently confine a single layer of immunomagnetic microbeads on the surface of the electrode and enable 7.5-fold signal enhancement In particular,the use of transparent SWCNTs to modify a transparent ITO electrode provides a two-order-of-magnitude ECL signal amplification.A good linear calibration curve is developed for hs-cTnI concentrations over a wide range from 10 fg/ml to 10 ng/ml,with the limit of detection calculated as 8.720 fg/ml (S/N=3).This ultrasensitive immunosensor exhibits superior detection performance with remarkable stability,reproducibility,and selectivity.Satisfactory recoveries are obtained in the detection of hs-cTnI in human serum,providing a potentia analysis protocol for clinical applications.
文摘目的:分析骨髓增殖性肿瘤(MPN)患者不确定潜能的克隆性造血(CHIP)相关基因突变谱和临床特征,探讨CHIP相关基因与其心脑血管事件(CCE)的相关性及可能作用机制。方法:回顾性分析2019年8月-2022年7月首都医科大学附属北京安贞医院血液科收治的73例MPN患者的临床资料和二代测序结果,采用Logistic回归分析CHIP相关基因、炎症细胞因子对MPN患者CCE的影响。结果:55例(75.3%)MPN患者检出CHIP相关基因,原发性血小板增多症(ET)和真性红细胞增多症(PV)患者CHIP相关基因各突变频率差异无统计学意义。CHIP相关基因突变以单基因形式为主,检出率从高至低依次为JAK2V617F(63.0%,46/73)、ASXL1(16.4%,12/73)、TET2(11.0%,8/73)、DNMT3A(9.6%,7/73)、SRSF2(6.9%,5/73)、SF3B1(4.1%,3/73)、TP53(1.4%,1/73)和PPMID(1.4%,1/73)。年龄>60岁患者CHIP相关基因检出率明显高于≤60岁者[91.7%(33/36)vs 59.5%(22/37)]。27例(37.0%)MPN患者伴CCE(MPN/CCE),2次CCE者5例,均为动脉事件。CCE组患者年龄(62.8±12.8 vs 53.9±15.8岁,P=0.015)、IL-1β水平(17.7±26.0vs 4.3±8.6,P=0.012)、IL-8水平(360.7±598.6 vs 108.3±317.0,P=0.045)、血栓形成史(29.6%vs 2.2%,P=0.020)和CHIP相关基因检出率(88.9%vs 67.4%,P=0.040)高于无CCE组。多因素Logistic回归分析结果显示,年龄(OR=0.917,95%CI:0.843-0.999,P=0.047)、血栓形成史(OR=34.148,95%CI:2.392-487.535,P=0.009)、任何1个CHIP相关基因突变(OR=16.065,95%CI:1.217-212.024,P=0.035)和IL-1β水平升高(OR=0.929,95%CI:0.870-0.992,P=0.027)均是MPN/CCE的独立危险因素;CHIP相关单基因突变与MPN/CCE无关,但DNMT3A(OR=88.717,95%CI:2.690-292.482,P=0.012)、ASXL1(OR=7.941,95%CI:1.045-60.353,P=0.045)突变是PV/CCE的独立危险因素。结论:MPN患者CHIP相关基因突变率高,尤其是60岁以上患者;高龄、血栓形成史、CHIP相关基因突变和IL-1β水平升高是MPN发生CCE的独立危险因素。DNMT3A、ASXL1单基因突变是PV患者CCE的独立危险因素。CHIP相关基因突变及炎症细胞因子IL-1β升高是MPN新的CCE危险因素。