Numerical Simulations of Jet Flow Inside Launching Box and Design of Pressure Opening the Covers of Missile Launching Box
1
作者 刘琦 郝继光 +1 位作者 姜毅 陈建伟 《Journal of Beijing Institute of Technology》 EI CAS 2004年第S1期54-57,共4页
Numerical simulations are presented for jet flow inside a launching box. The predictions are based on solutions of the unsteady three-dimensional Reynolds-averaged Navier-stokes equations. Since the pressure opening t... Numerical simulations are presented for jet flow inside a launching box. The predictions are based on solutions of the unsteady three-dimensional Reynolds-averaged Navier-stokes equations. Since the pressure opening the forward cover is given, the pressure opening the backward cover is designed by analyzing the flow field inside the launching box. The κ -ε turbulent model is presented and the structured meshes are used through the whole computational field. 展开更多
关键词 launching box the pressure opening the covers jet flow
下载PDF
Does high intraocular pressure exclude an open globe injury?
2
作者 Aruna Dharmasena Dong Young Park Mandagere Vishwanath 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第2期389-390,共2页
Dear Sir,Ocular trauma is a topic of unresolved controversies and there are continuous controversial and debatable diagnostic and management strategies for open-globe injuries[1].Amongst many types of ocular trauma,th... Dear Sir,Ocular trauma is a topic of unresolved controversies and there are continuous controversial and debatable diagnostic and management strategies for open-globe injuries[1].Amongst many types of ocular trauma,the open globe injury is the most serious due to its very poor visual prognosis and young population of patients are mostly affected[2].The treatment outcome may be improved by prompt diagnosis,and immediate surgical repair performed to high standard[3].Amongst the other clinical signs the intraocular pressure(IOP)is found to be particularly reduced and conventionally this is considered as a very reliable indicator of occult globe 展开更多
关键词 IOP Does high intraocular pressure exclude an open globe injury HIGH
下载PDF
Effect of body position on the pathogenesis of asymmetric primary open angle glaucoma 被引量:3
3
作者 Jing Tang Ni Li +2 位作者 Ying-Ping Deng Le-Mei Qiu Xiao-Ming Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第1期94-100,共7页
AIM: To explore the pathogenesis of asymmetric primary open angle glaucoma(POAG) in both eyes by comparing the intraocular pressure(IOP) of patients who sleep in different positions and to investigate the relatio... AIM: To explore the pathogenesis of asymmetric primary open angle glaucoma(POAG) in both eyes by comparing the intraocular pressure(IOP) of patients who sleep in different positions and to investigate the relationship between IOP variations and sleep positions.METHODS: One hundred and thirty-one patients with asymmetric POAG and forty-six healthy volunteers were enrolled. All participants completed a questionnaire that provided information about their sleep laterality. The cup disc ratio(C/D) and visual field defect established binocular asymmetry. The IOP of both eyes was measured using i Care parameters after the patients were asked to change body position. The "worse" and "better" eyes were identified according to the diagnosis, whereas the "dependent" and "independent" eyes were defined according to the lateral position. RESULTS: No significant difference in sleep laterality was observed between healthy people and patients with POAG(F=3.195, P=0.362). Among the enrolled patients, the IOP of the dependent eye was always greater than that of the independent eye in the lateral position(P〈0.05). In the patients with binocular asymmetric POAG, the questionnaire clearly showed that 85.7% of left side preferences were found their left eyes to be the worse eyes and the right eyes of 71.4% patients with a right side preference were the more serious. When the asymmetric C/D ratio was greater than or equal to 0.2, the worse eye of patients with POAG and a preferred sleeping position was the dependent eye(χ~2=16.762, P=0.001).CONCLUSION: A higher IOP was measured in the dependent eye in the lateral position. The long-term tendency to choose a lateral sleeping position might lead the dependent eye to manifest more severe symptoms than the independent eye. Thus, the lateral sleeping position might be one cause of asymmetric POAG. 展开更多
关键词 asymmetric primary open angle glaucoma intraocular pressure body position
下载PDF
MECHANISM OF WALL PRESSURE FLUCTUATIONS BENEATH THE OPEN CHANNEL FLOW 被引量:1
4
作者 ZHAO YAONAN, Tianjin University 《Journal of Hydrodynamics》 SCIE EI CSCD 1989年第1期52-60,共9页
Based on the measured results that wall pressure fluctuations are mainly de- cided by coherent structures of turbulence, the relationship between root-mean- square wall pressure and wall shear stress in turbulent shea... Based on the measured results that wall pressure fluctuations are mainly de- cided by coherent structures of turbulence, the relationship between root-mean- square wall pressure and wall shear stress in turbulent shear flow and that between the intensities of pressure and fluctuating velocity in homogeneous and isotropic turbulence are established in this paper. These relationships are consistent with former works, and have good agreement with experimental data. The paper also dis- cusses the concept of 'apparent pressure' on the wall in mean flow. 展开更多
关键词 MECHANISM OF WALL pressure FLUCTUATIONS BENEATH THE OPEN CHANNEL FLOW
原文传递