期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Parameters effects on spiking deconvolution of land seismic data 被引量:1
1
作者 MOHAMED Mhmod FENG Xuan XU Cong 《Global Geology》 2015年第4期226-231,共6页
Spiking deconvolution is a standard Wiener Levinson algorithm. The autocorrelation of the design time gate is computed and there is a specified taper on the design gate before the autoeorrelation is done. The standard... Spiking deconvolution is a standard Wiener Levinson algorithm. The autocorrelation of the design time gate is computed and there is a specified taper on the design gate before the autoeorrelation is done. The standard equations are set up, prewhitening is added to the zero lag value of the autocorrelation and the matrix is inverted to derive the spiking operator. In this study, the authors describe a technique for performing spiking deconvolution on prestack time migration (PSTM) data, to test the effect of operator length and percent prewhitening in spiking deconvolution and apply spiking deconvolution trace by trace, with operator lengths 15ms, 10 ms and 5 ms when percent prewhitening 0% , 40ms and 60ms for percent prewhitening 1%. The results show when prewhitening is 0% the shorter operator gives better results, but when value of prewhitening is bigger than 0% it is better to use longer operator lengths. 展开更多
关键词 spiking deconvolution prewhitening operator length PSTM data
下载PDF
A Mach-Zehnder interferometer electro-optic switch with ultralow voltage-length product using poled-polymer/silicon slot waveguide
2
作者 黄小亮 李翠婷 +1 位作者 党佩佩 郑传涛 《Optoelectronics Letters》 EI 2015年第4期264-267,共4页
By using poled-polymer/silicon slot waveguides in the active region and the Pockels effect of the poled-polymer,we propose a kind of Mach-Zehnder interferometer(MZI) electro-optic(EO) switch operated at 1 550 nm.Struc... By using poled-polymer/silicon slot waveguides in the active region and the Pockels effect of the poled-polymer,we propose a kind of Mach-Zehnder interferometer(MZI) electro-optic(EO) switch operated at 1 550 nm.Structural parameters are optimized for realizing normal switching function.Dependencies of switching characteristics on the slot waveguide parameters are investigated.For the silicon strip with dimension of 170 nm×300 nm,as the slot width varies from 50 nm to 100 nm,the switching voltage can be as low as 1.0 V with active region length of only 0.17–0.35 mm,and the length of the whole device is only about 770–950 μm.The voltage-length product of this switching structure is only 0.17–0.35 V·mm,and it is at least 19–40 times smaller than that of the traditional polymer MZI EO switch,which is 6.69 V·mm.Compared with our previously reported MZI EO switches,this switch exhibits some superior characteristics,including low switching voltage,compact device size and small wavelength dependency. 展开更多
关键词 switch waveguide interferometer length optic dependency operated directional cladding strip
原文传递
Fouling distribution in forward osmosis membrane process 被引量:2
3
作者 Junseok Lee Bongchul Kim Seungkwan Hong 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2014年第6期1348-1354,共7页
Fouling behavior along the length of membrane module was systematically investigated by performing simple modeling and lab-scale experiments of forward osmosis (FO) membrane process. The flux distribution model deve... Fouling behavior along the length of membrane module was systematically investigated by performing simple modeling and lab-scale experiments of forward osmosis (FO) membrane process. The flux distribution model developed in this study showed a good agreement with experimental results, validating the robustness of the model. This model demonstrated, as expected, that the permeate flux decreased along the membrane channel due to decreasing osmotic pressure differential across the FO membrane. A series of fouling experiments were conducted under the draw and feed solutions at various recoveries simulated by the model. The simulated fouling experiments revealed that higher organic (alginate) fouling and thus more flux decline were observed at the last section of a membrane channel, as foulants in feed solution became more concentrated. Furthermore, the water flux in FO process declined more severely as the recovery increased due to more foulants transported to membrane surface with elevated solute concentrations at higher recovery, which created favorable solution environments for organic adsorption. The fouling reversibility also decreased at the last section of the membrane channel, suggesting that fouling distribution on FO membrane along the module should be carefully examined to improve overall cleaning efficiency. Lastly, it was found that such fouling distribution observed with co-current flow operation became less pronounced in counter- current flow operation of FO membrane process. 展开更多
关键词 forward osmosis membrane module length organic fouling fouling reversibility counter-current flow FO operation
原文传递
Performance of a monolithic Tm:YLF micro laser
4
作者 姚宝权 李贺 +5 位作者 白爽 崔铮 李晓磊 段小明 申英杰 戴通宇 《Chinese Optics Letters》 SCIE EI CAS CSCD 2016年第6期51-54,共4页
We report a monolithic Tm:YLF micro laser in this Letter. In order to improve the relaxation oscillation of the laser, both ends of the crystal are coated, making the Tm:YLF crystal itself a resonant cavity. The mic... We report a monolithic Tm:YLF micro laser in this Letter. In order to improve the relaxation oscillation of the laser, both ends of the crystal are coated, making the Tm:YLF crystal itself a resonant cavity. The micro laser is pumped by a 792 nm laser diode operated in the continuous wave(CW) mode. We obtain maximum output powers of 7.78 and 10.4 W at the total incident power of 43.6 W with focus lenses of 37.5 and 40 mm, respectively,corresponding to the slope efficiencies of 25.6% and 40.0% and the optical–optical conversion efficiencies of 17.8%and 23.8%. It is clear that the amplitude of the relaxation oscillation is smaller and the beam quality is better with the focus length of 37.5 mm; however, the laser with the focus length of 40 mm produces a higher output power and a more stable wavelength centering at 1878.44 nm. 展开更多
关键词 relaxation pumped resonant monolithic coated operated length itself oscillation excited
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部