In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary ...In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary artery dissection(SCAD)phantoms.IVPAI provides high-resolution and high-penetration images of intramural hematoma(IMH)at different depths,so it is especially useful for imaging deep blood clots associated with imaging phantoms.IVOCT can readily visualize the double-lumen morphology of blood vessel walls to identify intimal tears.We also demonstrate the capability of this dual-mode endoscopic system using mimicking phantoms and biological samples of blood clots in ex vivo porcine arteries.The results of the experiments indicate that the combined IVPAI and IVOCT technique has the potential to provide a more accurate SCAD assessment method for clinical applications.展开更多
Adaptive optics(AO)is essential for high-quality ground-based observations with large telescopes because it counters the impact of wavefront aberrations caused by atmospheric turbulence.The new vacuum solar telescope(...Adaptive optics(AO)is essential for high-quality ground-based observations with large telescopes because it counters the impact of wavefront aberrations caused by atmospheric turbulence.The new vacuum solar telescope(NVST)is one of the most important high-resolution solar observation instruments in the world.Three sets of solar adaptive optics systems have been developed and installed on this telescope:conventional adaptive optics,ground layer adaptive optics,and multi-conjugate adaptive optics.These have been in operation from 2018 to 2023.This paper details the development and application of solar adaptive optics on the NVST and discusses the newest instrumentation.展开更多
Several studies have found that transplantation of neural progenitor cells(NPCs)promotes the survival of injured neurons.However,a poor integration rate and high risk of tumorigenicity after cell transplantation limit...Several studies have found that transplantation of neural progenitor cells(NPCs)promotes the survival of injured neurons.However,a poor integration rate and high risk of tumorigenicity after cell transplantation limits their clinical application.Small extracellular vesicles(sEVs)contain bioactive molecules for neuronal protection and regeneration.Previous studies have shown that stem/progenitor cell-derived sEVs can promote neuronal survival and recovery of neurological function in neurodegenerative eye diseases and other eye diseases.In this study,we intravitreally transplanted sEVs derived from human induced pluripotent stem cells(hiPSCs)and hiPSCs-differentiated NPCs(hiPSC-NPC)in a mouse model of optic nerve crush.Our results show that these intravitreally injected sEVs were ingested by retinal cells,especially those localized in the ganglion cell layer.Treatment with hiPSC-NPC-derived sEVs mitigated optic nerve crush-induced retinal ganglion cell degeneration,and regulated the retinal microenvironment by inhibiting excessive activation of microglia.Component analysis further revealed that hiPSC-NPC derived sEVs transported neuroprotective and anti-inflammatory miRNA cargos to target cells,which had protective effects on RGCs after optic nerve injury.These findings suggest that sEVs derived from hiPSC-NPC are a promising cell-free therapeutic strategy for optic neuropathy.展开更多
To investigate the mechanisms underlying the onset and progression of ischemic stroke,some methods have been proposed that can simultaneously monitor and create embolisms in the animal cerebral cortex.However,these me...To investigate the mechanisms underlying the onset and progression of ischemic stroke,some methods have been proposed that can simultaneously monitor and create embolisms in the animal cerebral cortex.However,these methods often require complex systems and the effect of age on cerebral embolism has not been adequately studied,although ischemic stroke is strongly age-related.In this study,we propose an optical-resolution photoacoustic microscopy-based visualized photothrombosis methodology to create and monitor ischemic stroke in mice simultaneously using a 532 nm pulsed laser.We observed the molding process in mice of different ages and presented age-dependent vascular embolism differentiation.Moreover,we integrated optical coherence tomography angiography to investigate age-associated trends in cerebrovascular variability following a stroke.Our imaging data and quantitative analyses underscore the differential cerebrovascular responses to stroke in mice of different ages,thereby highlighting the technique's potential for evaluating cerebrovascular health and unraveling age-related mechanisms involved in ischemic strokes.展开更多
BACKGROUND Atypical optic neuritis,consisting of neuromyelitis optica spectrum disorders(NMOSD)or myelin oligodendrocyte glycoprotein antibody disease(MOGAD),has a very similar presentation but different prognostic im...BACKGROUND Atypical optic neuritis,consisting of neuromyelitis optica spectrum disorders(NMOSD)or myelin oligodendrocyte glycoprotein antibody disease(MOGAD),has a very similar presentation but different prognostic implications and longterm management strategies.Vascular and metabolic factors are being thought to play a role in such autoimmune neuro-inflammatory disorders,apart from the obvious immune mediated damage.With the advent of optical coherence tomography angiography(OCTA),it is easy to pick up on these subclinical macular microvascular and structural changes.AIM To study the macular microvascular and structural changes on OCTA in atypical optic neuritis.METHODS This observational cross-sectional study involved 8 NMOSD and 17 MOGAD patients,diagnosed serologically,as well as 10 healthy controls.Macular vascular density(MVD)and ganglion cell+inner plexiform layer thickness(GCIPL)were studied using OCTA.RESULTS There was a significant reduction in MVD in NMOSD and MOGAD affected as well as unaffected eyes when compared with healthy controls.NMOSD and MOGAD affected eyes had significant GCIPL thinning compared with healthy controls.NMOSD unaffected eyes did not show significant GCIPL thinning compared to healthy controls in contrast to MOGAD unaffected eyes.On comparing NMOSD with MOGAD,there was no significant difference in terms of MVD or GCIPL in the affected or unaffected eyes.CONCLUSION Although significant microvascular and structural changes are present on OCTA between atypical optic neuritis and normal patients,they could not help in differentiating between NMOSD and MOGAD cases.展开更多
A 12 Gbit/s limiting amplifier for fiber-optic transmission system is realized in a 2μm GaAs HBT technology. The whole circuit consists of an input buffer, three similar amplifier cells, an output buffer for driving ...A 12 Gbit/s limiting amplifier for fiber-optic transmission system is realized in a 2μm GaAs HBT technology. The whole circuit consists of an input buffer, three similar amplifier cells, an output buffer for driving 50 ft transmission lines and a pair of feedback networks for offset cancellation. At a positive supply voltage of 2 V and a negative supply voltage of - 2V, the power dissipation is about 280 mW. The small-signal gain is higher than 46 dB and the input dynamic range is about 40 dB with a constant single-ended output voltage swing of 400 mV. Satisfactory eye-diagrams are obtained at the bit rate of 12 Gbit/s limited by the test set-up. The chip area is 1.15 mm ×0.7 mm.展开更多
This paper presents a fiber optic temperature measuring system used for measuring the temperature in many occasions. The system is of reflective type and composed of thermostatic bimetal plate, lever piston framewo...This paper presents a fiber optic temperature measuring system used for measuring the temperature in many occasions. The system is of reflective type and composed of thermostatic bimetal plate, lever piston framework, optical grating and optical fiber probes. When the temperature changes, the thermostatic bimetal plate deforms. Through lever piston framework, the optical grating produces displacement in the upright direction. Thus the change of the temperature is transformed into the upright displacement of the optical grating. Optical fiber probes are used for detecting the number of streak lines of the optical grating′s displacement depending on the change of temperature. The detected signal can be transmitted to the control center through optical fiber cable up to distance of 1 km. The measurable range of this system reaches 100℃ with accuracy of ±0.2℃.展开更多
Optical coherence tomography(OCT) is an optical imaging modality that performs high-resolution,cross-sectional,subsurface tomographic imaging of the microstructure of tissues.The physical principle of OCT is similar t...Optical coherence tomography(OCT) is an optical imaging modality that performs high-resolution,cross-sectional,subsurface tomographic imaging of the microstructure of tissues.The physical principle of OCT is similar to that of B-mode ultrasound imaging,except that it uses infrared light waves rather than acoustic waves.The in vivo resolution is 10-25 times better(about 10 μm) than with high-frequency ultrasound imaging,but the depth of penetration is limited to 1-3 mm,depending upon tissue structure,depth of focus of the probe used,and pressure applied to the tissue surface.In the last decade,OCT technology has evolved from an experimental laboratory tool to a new diagnostic imaging modality with a wide spectrum of clinical applications in medical practice,including the gastrointestinal(GI) tract and pancreatic-biliary ductal system.OCT imaging from the GI tract can be done in humans by using narrow-diameter,catheter-based probes that can be inserted through the accessory channel of either a conventional front-view endoscope,for investigating the epithelial structure of the GI tract,or a side-view endoscope,inside a standard transparent ERCP catheter,for investigating the pancreatico-biliary ductal system.Esophagus and the esophago-gastric junction has been the most widely investigated organ so far;more recently,also duodenum,colon and pancreatico-biliary ductal system have been extensively investigated.OCT imaging of the gastro-intestinal wall structure is characterized by a multiple-layer architecture that permits an accurate evaluation of the mucosa,lamina propria,muscularis mucosae,andpart of the submucosa.The technique may be,therefore,used to identify pre-neoplastic conditions of the GI tract,such as Barrett's epithelium and dysplasia,and evaluate the depth of penetration of early-stage neoplastic lesions.OCT imaging of the pancreatic and biliary ductal system could improve the diagnostic accuracy for ductal epithelial changes and the differential diagnosis between neoplastic and non-neoplastic lesions.展开更多
AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four ...AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four eyes with age-related cataracts were randomly divided into spherical and aspherical lens implantation groups. Best-corrected visual acuity (BCVA) was measured preoperatively, one day, one week, two weeks, one month and two months after surgery. A biometric systems analysis using the OQAS objective scattering index (OSI) was performed. RESULTS: There were no significant differences in visual acuity (P〉0.05) before and after spherical and aspheric lens implantation. There was a negative linear correction between the OSI value and BCVA (t-=-0.634, P=-0.000), and positive corrections between the OSI value and the lens LOCUS III value of nucleus color (NC), nucleus opacity (NO), cortex (C) and posterior lens capsular (P) (r=0.704, P=0.000; r=0.514, P=0.000; r=0.276, P=0.020; r=0.417, P=-0.000, respectively). OSI values of spherical vs aspherical lenses were 11.5±3.6 vs 11.8±3.4, 4.1±0.9 vs 3.3±0.8, 3.5±0.9 vs 2.7±0.7, 3.3±0.8 vs 2.6±0.7, 3.2±0.7 vs 2.5±0.8, and 3.2±0.8 vs 2.50.8 before and ld, 1, 2wk, 1 and 2mo after surgery, respectively. All time points varied significantly (P〈0.01) between the two groups. CONCLUSION: Aspherical IOLs does not significantly affect visual acuity compared with spherical IOLs. The OSI value, was significantly lower in the aspherical lens group compared with the spherical lens. This study shows that objective visual quality of aspheric IOLs is better than that of the spherical lens by means of OQAS biological measurement method.展开更多
AIMTo evaluate intra-session repeatability and reproducibility of optical quality parameters measured at objective and subjective best focuses in a double-pass system.METHODSThirty Chinese healthy adults (19 to 40 yea...AIMTo evaluate intra-session repeatability and reproducibility of optical quality parameters measured at objective and subjective best focuses in a double-pass system.METHODSThirty Chinese healthy adults (19 to 40 years old) meeting our inclusion criterion were enrolled in the study. After a basic eye examination, two methods of optical quality measurement, based on subjective and objective best focuses were performed using the Optical Quality Analysis System (OQAS) with an artificial pupil diameter of 4.0 mm.RESULTSWith each method, three consecutive measurements of the following parameters: the modulation transfer function cutoff frequency (MTF<sub>cutoff</sub>), the Strehl<sup>2D</sup> ratio, the OQAS values (OVs) at contrasts of 100%, 20%, 9% and the objective scatter index (OSI) were performed by an experienced examiner. The repeatability of each method was evaluated by the repeatability limit (RL) and the coefficient of repeatability (COR). Reproducibility of the two methods was evaluated by intra-class correlation coefficient (ICC) and the 95% limits of agreement (Bland and Altman analysis). Thirty subjects, seven females and twenty three males, of whom 15 right eyes and 15 left eyes were selected randomly for recruitment in the study. The RLs (percentage) for the six parameters measured at objective focus and subjective focus ranged from 8.44% to 15.13% and 10.85% to 16.26%, respectively. The CORs for the two measurement methods ranged from 8.27% to 14.83% and 10.63% to 15.93%, respectively. With regard to reproducibility, the ICCs for the six parameters of OQAS ranged from 0.024 to 0.276. The 95% limits of agreement obtained for the six parameters (in comparison of the two methods) ranged from -0.57 to 42.18 (MTF<sub>cutoff</sub>), -0.01 to 0.23 (Strehl<sup>2D</sup> ratio), -0.02 to 1.40 (OV<sub>100%</sub>), -0.10 to 1.75 (OV<sub>20%</sub>), -0.14 to 1.80 (OV<sub>9%</sub>) and -1.46 to 0.18 (OSI).CONCLUSIONMeasurements provided by OQAS with either method showed a good repeatability. However, the results obtained from the two different measurement methods showed a poor reproducibility. These findings suggest that it might be best to evaluate patients' optical quality by OQAS using the best focus as chosen automatically by the instrument.展开更多
Rho-associated kinase (ROCK) is a serine/threonine kinase and one of the major downstream effectors of the small GTPase RhoA. The Rho/ROCK pathway is closely related to the pathogenesis of several central nervous syst...Rho-associated kinase (ROCK) is a serine/threonine kinase and one of the major downstream effectors of the small GTPase RhoA. The Rho/ROCK pathway is closely related to the pathogenesis of several central nervous system (CNS) disorders, and involved in many aspects of neuronal functions including neurite outgrowth and retraction. In the adult CNS, the damaged neuron regeneration is very difficult due to the presence of myelin-associated axon growth inhibitors such as Nogo, myelin-associated glycoprotein (MAG) and oligodendrocyte-myelin glycoprotein (Omgp), etc. The effects of these axon growth inhibitors are reversed by blocking the Rho/ROCK pathway 47 vitro, and the inhibition of Rho/ROCK pathway can promote axon regeneration and functional recovery in the injured CNS in viva In addition, the therapeutic effects of the Rho/ROCK inhibitors have also been demonstrated in some animal models and the Rho/ROCK pathway becomes an attractive target for the development of drugs for treating CNS disorders. In this review, we summarized on the effect of the Rho and the downstream factor ROCK in neural regeneration, and the potential therapeutic effect of Rho/ROCK inhibitors in the survival and axonal regeneration of retinal ganglion cell was also discussed.展开更多
With rapid advancements in Infra-Red (IR) detection techniques, the range from where the IR-guided missiles are able to lock the target aircraft has increased. To avoid the detection and tracking by modern IR-guided m...With rapid advancements in Infra-Red (IR) detection techniques, the range from where the IR-guided missiles are able to lock the target aircraft has increased. To avoid the detection and tracking by modern IR-guided missiles, the aircraft and helicopters also demand progress in its stealth techniques. Hence, study of Infra-Red Signature Suppression (IRSS) systems in aircraft and helicopters has become vital even in design stage. Optical blocking (masking) is one of the effective IRSS techniques used to block the Line- Of-Sight (LOS) of the hot engine parts of the exhaust geometry. This paper reviews the various patents on IR signature suppression systems based on the optical blocking method or a combination of IRSS techniques. The performance penalties generated due to installation of various IRSS methods in aircraft and helicopters are also discussed.展开更多
Geotechnical stability is a major concern for the long-term safety and integrity of underground infrastructures such as tunnels, railway stations, mine shafts and hydraulic power chambers. An effective geotechnical mo...Geotechnical stability is a major concern for the long-term safety and integrity of underground infrastructures such as tunnels, railway stations, mine shafts and hydraulic power chambers. An effective geotechnical monitoring system is able to provide adequate warning to underground personnel prior to any unexpected major geotechnical failure. This paper reviews the conventional geotechnical monitoring sensors and the emerging Fibre Optic Sensing(FOS) techniques, pointing out their unique features and major differences. Recent advances in various FOS based monitoring systems, including Brillouin time domain distributed optical sensors and fibre Bragg grating(FBG) sensors, are investigated through a critical review of the laboratory studies and field applications used for underground geotechnical monitoring. Particular emphasis is given to fibre packaging, temperature compensation, installation methods and instrumentation performance in the underground environment. A detailed discussion of the advantages and limitations of each FOS monitoring system is also presented in this paper.展开更多
To establish a theoretical basis for providing a better design method of multielement optical systems, we have developed a third-order geometric theory of a plane-symmetric multielement optical system that consists of...To establish a theoretical basis for providing a better design method of multielement optical systems, we have developed a third-order geometric theory of a plane-symmetric multielement optical system that consists of a planar light source, an arbitrary number of ellipsoidal gratings, and an image plane. Analytic formulas of spot diagrams are derived for the system by analytically following a ray-tracing formalism. With these formulas, coma, spherical aberration, and resultant aberration are discussed. To make the theory practical, we determine the aberration coefficients numerically, rather than analytically, with the aid of ray tracing that takes into account the angular distribution of rays originating from a given light source. A merit function is defined so as to represent closely the variance of the spots formed when an infinite number of rays are traced and to take into account the dimensions of the source and the last optical element. The theory is also applicable to mirror-grating or mirror systems.展开更多
We propose a scheme for realizing the optical nonreciprocal response based a four-mode optomechanical system,consisting of two charged mechanical modes and two linearly coupled optical modes. Two charged mechanical mo...We propose a scheme for realizing the optical nonreciprocal response based a four-mode optomechanical system,consisting of two charged mechanical modes and two linearly coupled optical modes. Two charged mechanical modes are coupled by Coulomb interaction, and two optical modes are coupled to one of mechanical modes by radiation pressure. We numerically evaluate the transmission probability of the probe field to obtain the optimum optical nonreciprocal response parameters. Also, we show that the optical nonreciprocal response is caused by the quantum interference between the optomechanical couplings and the linearly coupled interaction that breaks the time-reversal symmetry.展开更多
Optical tweezers have been a valuable research tool since their invention in the 1980s. One of the most important developments in optical tweezers in recent years is the creation of two-dimensional arrays of optical t...Optical tweezers have been a valuable research tool since their invention in the 1980s. One of the most important developments in optical tweezers in recent years is the creation of two-dimensional arrays of optical traps. In this paper, a method based on interference is discussed to form gradient laser fields, which may cause the spatial modulation of particle concentration. The parameters related to the optical tweezers array are discussed in detail and simulated by the Matlab software to show the influence of important parameters on the distribution of particle concentration. The spatial redistribution of particles in a laser interference field can also be predicted according to the theoretical analysis.展开更多
In the intensity modulation and direct detection (IM/DD) multiple-input multiple-output (MIMO) optical wireless communication systems, a direct-current-biased adaptive modulation scheme is proposed to guarantee th...In the intensity modulation and direct detection (IM/DD) multiple-input multiple-output (MIMO) optical wireless communication systems, a direct-current-biased adaptive modulation scheme is proposed to guarantee the nonnegative property of transmitted signals, and the MIMO channel is converted to a parallel channel by using a singular value decomposition. Besides, a QR decomposition and successive interference cancellation based adaptive modulation scheme is proposed, and the MIMO channel can be simplified to a parallel channel under the bit error ratio (BER) target constraint. The power is optimally allocated to each sub-channel to maximize the data rate. Simulation results show that the proposed adaptive modulation schemes can effectively improve the transmission rate of the systems under the BER target and constant optical power constraints. The proposed adaptive modulation schemes make use of the multiplexing gain of the MIMO techniques, and can further improve the spectrum efficiency of optical wireless systems.展开更多
A mobile fiber-optic laser-induced breakdown spectrometer(FO-LIBS) prototype was developed to rapidly detect a large quantity of steel material online and quantitatively analyze the trace elements in a large-diameter ...A mobile fiber-optic laser-induced breakdown spectrometer(FO-LIBS) prototype was developed to rapidly detect a large quantity of steel material online and quantitatively analyze the trace elements in a large-diameter steel tube.Twenty-four standard samples and a polynomial fitting method were used to establish calibration curve models.The R^2 factors of the calibration curves were all above 0.99,except for Cu,indicating the elements’ strong self-absorption effect.Five special steel materials were rapidly detected in the steel mill.The average absolute errors of Mn,Cr,Ni,V,Cu,and Mo in the special steel materials were 0.039,0.440,0.033,0.057,0.003,and0.07 wt%,respectively,and their average relative errors fluctuated from 2.9% to 15.7%.The results demonstrated that the performance of this mobile FO-LIBS prototype can be compared with that of most conventional LIBS systems,but the more robust and flexible characteristics of the FO-LIBS prototype provide a feasible approach for promoting LIBS from the laboratory to the industry.展开更多
Micro-optical electromechanical systems(MOEMS)combine the merits of micro-electromechanical systems(MEMS)and micro-optics to enable unique optical functions for a wide range of advanced applications.Using simple exter...Micro-optical electromechanical systems(MOEMS)combine the merits of micro-electromechanical systems(MEMS)and micro-optics to enable unique optical functions for a wide range of advanced applications.Using simple external electromechanical control methods,such as electrostatic,magnetic or thermal effects,Si-based MOEMS can achieve precise dynamic optical modulation.In this paper,we will briefly review the technologies and applications of Si-based MOEMS.Their basic working principles,advantages,general materials and micromachining fabrication technologies are introduced concisely,followed by research progress of advanced Si-based MOEMS devices,including micromirrors/micromirror arrays,micro-spectrometers,and optical/photonic switches.Owing to the unique advantages of Si-based MOEMS in spatial light modulation and high-speed signal processing,they have several promising applications in optical communications,digital light processing,and optical sensing.Finally,future research and development prospects of Si-based MOEMS are discussed.展开更多
The measurement and control of high temperature play very important roles in national defense,military,scientific experiments,industrial and agricultural production.Photoelectric pyrometer is one of the important radi...The measurement and control of high temperature play very important roles in national defense,military,scientific experiments,industrial and agricultural production.Photoelectric pyrometer is one of the important radiation thermometers for non-contact temperature measurement.It has an important application in the field of high temperature measurement,and its performance directly affects the accuracy of temperature measurement.By improving the design of the detection optical system of the photoelectric pyrometer,the imaging performance of the photoelectric pyrometer can be improved effectively,and the temperature measurement accuracy can be improved.In this paper,the temperature measurement principle of photoelectric pyrometer,the wo rking principle of the detection optical system and the composition of the system are introduced.The optical components that affect the imaging of the optical system of the photoelectric pyrometer are analyzed.The optical pyrometer detection optical system is simulated by ZEMAX software,based on the analysis results,the Modulation Transfer Function(MTF)and the spot Diagram are used as the main evaluation criteria to optimize the design of the objective lens of the photoelectric pyrometer detection optical system.The imaging performance of the photoelectric pyrometer detection optical system and the accuracy of temperature measurement of the photoelectric pyrometer are improved by optimization design of the detection optical system.展开更多
基金funding from the National Natural Science Foundation of China(NSFC)under grants 61627827,61705068the Natural Science Foundation of Fujian Province 2021J01813the Fujian Medical University Research Foundation of Talented Scholars XRCZX2021004.
文摘In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary artery dissection(SCAD)phantoms.IVPAI provides high-resolution and high-penetration images of intramural hematoma(IMH)at different depths,so it is especially useful for imaging deep blood clots associated with imaging phantoms.IVOCT can readily visualize the double-lumen morphology of blood vessel walls to identify intimal tears.We also demonstrate the capability of this dual-mode endoscopic system using mimicking phantoms and biological samples of blood clots in ex vivo porcine arteries.The results of the experiments indicate that the combined IVPAI and IVOCT technique has the potential to provide a more accurate SCAD assessment method for clinical applications.
基金funded by the National Natural Science Foundation of China(11727805,12103057)the Youth Innovation Promotion Association of the Chinese Academy of Sciences(2021378).
文摘Adaptive optics(AO)is essential for high-quality ground-based observations with large telescopes because it counters the impact of wavefront aberrations caused by atmospheric turbulence.The new vacuum solar telescope(NVST)is one of the most important high-resolution solar observation instruments in the world.Three sets of solar adaptive optics systems have been developed and installed on this telescope:conventional adaptive optics,ground layer adaptive optics,and multi-conjugate adaptive optics.These have been in operation from 2018 to 2023.This paper details the development and application of solar adaptive optics on the NVST and discusses the newest instrumentation.
基金supported by the National Natural Science Foundation of China,No.82271114the Natural Science Foundation of Zhejiang Province of China,No.LZ22H120001(both to ZLC).
文摘Several studies have found that transplantation of neural progenitor cells(NPCs)promotes the survival of injured neurons.However,a poor integration rate and high risk of tumorigenicity after cell transplantation limits their clinical application.Small extracellular vesicles(sEVs)contain bioactive molecules for neuronal protection and regeneration.Previous studies have shown that stem/progenitor cell-derived sEVs can promote neuronal survival and recovery of neurological function in neurodegenerative eye diseases and other eye diseases.In this study,we intravitreally transplanted sEVs derived from human induced pluripotent stem cells(hiPSCs)and hiPSCs-differentiated NPCs(hiPSC-NPC)in a mouse model of optic nerve crush.Our results show that these intravitreally injected sEVs were ingested by retinal cells,especially those localized in the ganglion cell layer.Treatment with hiPSC-NPC-derived sEVs mitigated optic nerve crush-induced retinal ganglion cell degeneration,and regulated the retinal microenvironment by inhibiting excessive activation of microglia.Component analysis further revealed that hiPSC-NPC derived sEVs transported neuroprotective and anti-inflammatory miRNA cargos to target cells,which had protective effects on RGCs after optic nerve injury.These findings suggest that sEVs derived from hiPSC-NPC are a promising cell-free therapeutic strategy for optic neuropathy.
基金supported by University of Macao,China,Nos.MYRG2022-00054-FHS and MYRG-GRG2023-00038-FHS-UMDF(to ZY)the Macao Science and Technology Development Fund,China,Nos.FDCT0048/2021/AGJ and FDCT0020/2019/AMJ and FDCT 0011/2018/A1(to ZY)Natural Science Foundation of Guangdong Province of China,No.EF017/FHS-YZ/2021/GDSTC(to ZY)。
文摘To investigate the mechanisms underlying the onset and progression of ischemic stroke,some methods have been proposed that can simultaneously monitor and create embolisms in the animal cerebral cortex.However,these methods often require complex systems and the effect of age on cerebral embolism has not been adequately studied,although ischemic stroke is strongly age-related.In this study,we propose an optical-resolution photoacoustic microscopy-based visualized photothrombosis methodology to create and monitor ischemic stroke in mice simultaneously using a 532 nm pulsed laser.We observed the molding process in mice of different ages and presented age-dependent vascular embolism differentiation.Moreover,we integrated optical coherence tomography angiography to investigate age-associated trends in cerebrovascular variability following a stroke.Our imaging data and quantitative analyses underscore the differential cerebrovascular responses to stroke in mice of different ages,thereby highlighting the technique's potential for evaluating cerebrovascular health and unraveling age-related mechanisms involved in ischemic strokes.
文摘BACKGROUND Atypical optic neuritis,consisting of neuromyelitis optica spectrum disorders(NMOSD)or myelin oligodendrocyte glycoprotein antibody disease(MOGAD),has a very similar presentation but different prognostic implications and longterm management strategies.Vascular and metabolic factors are being thought to play a role in such autoimmune neuro-inflammatory disorders,apart from the obvious immune mediated damage.With the advent of optical coherence tomography angiography(OCTA),it is easy to pick up on these subclinical macular microvascular and structural changes.AIM To study the macular microvascular and structural changes on OCTA in atypical optic neuritis.METHODS This observational cross-sectional study involved 8 NMOSD and 17 MOGAD patients,diagnosed serologically,as well as 10 healthy controls.Macular vascular density(MVD)and ganglion cell+inner plexiform layer thickness(GCIPL)were studied using OCTA.RESULTS There was a significant reduction in MVD in NMOSD and MOGAD affected as well as unaffected eyes when compared with healthy controls.NMOSD and MOGAD affected eyes had significant GCIPL thinning compared with healthy controls.NMOSD unaffected eyes did not show significant GCIPL thinning compared to healthy controls in contrast to MOGAD unaffected eyes.On comparing NMOSD with MOGAD,there was no significant difference in terms of MVD or GCIPL in the affected or unaffected eyes.CONCLUSION Although significant microvascular and structural changes are present on OCTA between atypical optic neuritis and normal patients,they could not help in differentiating between NMOSD and MOGAD cases.
文摘A 12 Gbit/s limiting amplifier for fiber-optic transmission system is realized in a 2μm GaAs HBT technology. The whole circuit consists of an input buffer, three similar amplifier cells, an output buffer for driving 50 ft transmission lines and a pair of feedback networks for offset cancellation. At a positive supply voltage of 2 V and a negative supply voltage of - 2V, the power dissipation is about 280 mW. The small-signal gain is higher than 46 dB and the input dynamic range is about 40 dB with a constant single-ended output voltage swing of 400 mV. Satisfactory eye-diagrams are obtained at the bit rate of 12 Gbit/s limited by the test set-up. The chip area is 1.15 mm ×0.7 mm.
文摘This paper presents a fiber optic temperature measuring system used for measuring the temperature in many occasions. The system is of reflective type and composed of thermostatic bimetal plate, lever piston framework, optical grating and optical fiber probes. When the temperature changes, the thermostatic bimetal plate deforms. Through lever piston framework, the optical grating produces displacement in the upright direction. Thus the change of the temperature is transformed into the upright displacement of the optical grating. Optical fiber probes are used for detecting the number of streak lines of the optical grating′s displacement depending on the change of temperature. The detected signal can be transmitted to the control center through optical fiber cable up to distance of 1 km. The measurable range of this system reaches 100℃ with accuracy of ±0.2℃.
文摘Optical coherence tomography(OCT) is an optical imaging modality that performs high-resolution,cross-sectional,subsurface tomographic imaging of the microstructure of tissues.The physical principle of OCT is similar to that of B-mode ultrasound imaging,except that it uses infrared light waves rather than acoustic waves.The in vivo resolution is 10-25 times better(about 10 μm) than with high-frequency ultrasound imaging,but the depth of penetration is limited to 1-3 mm,depending upon tissue structure,depth of focus of the probe used,and pressure applied to the tissue surface.In the last decade,OCT technology has evolved from an experimental laboratory tool to a new diagnostic imaging modality with a wide spectrum of clinical applications in medical practice,including the gastrointestinal(GI) tract and pancreatic-biliary ductal system.OCT imaging from the GI tract can be done in humans by using narrow-diameter,catheter-based probes that can be inserted through the accessory channel of either a conventional front-view endoscope,for investigating the epithelial structure of the GI tract,or a side-view endoscope,inside a standard transparent ERCP catheter,for investigating the pancreatico-biliary ductal system.Esophagus and the esophago-gastric junction has been the most widely investigated organ so far;more recently,also duodenum,colon and pancreatico-biliary ductal system have been extensively investigated.OCT imaging of the gastro-intestinal wall structure is characterized by a multiple-layer architecture that permits an accurate evaluation of the mucosa,lamina propria,muscularis mucosae,andpart of the submucosa.The technique may be,therefore,used to identify pre-neoplastic conditions of the GI tract,such as Barrett's epithelium and dysplasia,and evaluate the depth of penetration of early-stage neoplastic lesions.OCT imaging of the pancreatic and biliary ductal system could improve the diagnostic accuracy for ductal epithelial changes and the differential diagnosis between neoplastic and non-neoplastic lesions.
文摘AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four eyes with age-related cataracts were randomly divided into spherical and aspherical lens implantation groups. Best-corrected visual acuity (BCVA) was measured preoperatively, one day, one week, two weeks, one month and two months after surgery. A biometric systems analysis using the OQAS objective scattering index (OSI) was performed. RESULTS: There were no significant differences in visual acuity (P〉0.05) before and after spherical and aspheric lens implantation. There was a negative linear correction between the OSI value and BCVA (t-=-0.634, P=-0.000), and positive corrections between the OSI value and the lens LOCUS III value of nucleus color (NC), nucleus opacity (NO), cortex (C) and posterior lens capsular (P) (r=0.704, P=0.000; r=0.514, P=0.000; r=0.276, P=0.020; r=0.417, P=-0.000, respectively). OSI values of spherical vs aspherical lenses were 11.5±3.6 vs 11.8±3.4, 4.1±0.9 vs 3.3±0.8, 3.5±0.9 vs 2.7±0.7, 3.3±0.8 vs 2.6±0.7, 3.2±0.7 vs 2.5±0.8, and 3.2±0.8 vs 2.50.8 before and ld, 1, 2wk, 1 and 2mo after surgery, respectively. All time points varied significantly (P〈0.01) between the two groups. CONCLUSION: Aspherical IOLs does not significantly affect visual acuity compared with spherical IOLs. The OSI value, was significantly lower in the aspherical lens group compared with the spherical lens. This study shows that objective visual quality of aspheric IOLs is better than that of the spherical lens by means of OQAS biological measurement method.
文摘AIMTo evaluate intra-session repeatability and reproducibility of optical quality parameters measured at objective and subjective best focuses in a double-pass system.METHODSThirty Chinese healthy adults (19 to 40 years old) meeting our inclusion criterion were enrolled in the study. After a basic eye examination, two methods of optical quality measurement, based on subjective and objective best focuses were performed using the Optical Quality Analysis System (OQAS) with an artificial pupil diameter of 4.0 mm.RESULTSWith each method, three consecutive measurements of the following parameters: the modulation transfer function cutoff frequency (MTF<sub>cutoff</sub>), the Strehl<sup>2D</sup> ratio, the OQAS values (OVs) at contrasts of 100%, 20%, 9% and the objective scatter index (OSI) were performed by an experienced examiner. The repeatability of each method was evaluated by the repeatability limit (RL) and the coefficient of repeatability (COR). Reproducibility of the two methods was evaluated by intra-class correlation coefficient (ICC) and the 95% limits of agreement (Bland and Altman analysis). Thirty subjects, seven females and twenty three males, of whom 15 right eyes and 15 left eyes were selected randomly for recruitment in the study. The RLs (percentage) for the six parameters measured at objective focus and subjective focus ranged from 8.44% to 15.13% and 10.85% to 16.26%, respectively. The CORs for the two measurement methods ranged from 8.27% to 14.83% and 10.63% to 15.93%, respectively. With regard to reproducibility, the ICCs for the six parameters of OQAS ranged from 0.024 to 0.276. The 95% limits of agreement obtained for the six parameters (in comparison of the two methods) ranged from -0.57 to 42.18 (MTF<sub>cutoff</sub>), -0.01 to 0.23 (Strehl<sup>2D</sup> ratio), -0.02 to 1.40 (OV<sub>100%</sub>), -0.10 to 1.75 (OV<sub>20%</sub>), -0.14 to 1.80 (OV<sub>9%</sub>) and -1.46 to 0.18 (OSI).CONCLUSIONMeasurements provided by OQAS with either method showed a good repeatability. However, the results obtained from the two different measurement methods showed a poor reproducibility. These findings suggest that it might be best to evaluate patients' optical quality by OQAS using the best focus as chosen automatically by the instrument.
基金Supported by National Nature Science Foundation of China (No.81070728)Shanghai "Science and Technology Innovation Action Plan" Basic Research Key Project,China (No.11JC1407700 and 11 JC1407701)+1 种基金Shanghai Nature Science Foundation, China (No.08ZR1413900)Shanghai Leading Academic Discipline Project, China(No.S30205)
文摘Rho-associated kinase (ROCK) is a serine/threonine kinase and one of the major downstream effectors of the small GTPase RhoA. The Rho/ROCK pathway is closely related to the pathogenesis of several central nervous system (CNS) disorders, and involved in many aspects of neuronal functions including neurite outgrowth and retraction. In the adult CNS, the damaged neuron regeneration is very difficult due to the presence of myelin-associated axon growth inhibitors such as Nogo, myelin-associated glycoprotein (MAG) and oligodendrocyte-myelin glycoprotein (Omgp), etc. The effects of these axon growth inhibitors are reversed by blocking the Rho/ROCK pathway 47 vitro, and the inhibition of Rho/ROCK pathway can promote axon regeneration and functional recovery in the injured CNS in viva In addition, the therapeutic effects of the Rho/ROCK inhibitors have also been demonstrated in some animal models and the Rho/ROCK pathway becomes an attractive target for the development of drugs for treating CNS disorders. In this review, we summarized on the effect of the Rho and the downstream factor ROCK in neural regeneration, and the potential therapeutic effect of Rho/ROCK inhibitors in the survival and axonal regeneration of retinal ganglion cell was also discussed.
基金the Indian Institute of Technology Bombay’s Post-Doctoral Research Program, vide appointment no. AO/Admn1/33/2018 dated 10.Aug’2018 for providing funding
文摘With rapid advancements in Infra-Red (IR) detection techniques, the range from where the IR-guided missiles are able to lock the target aircraft has increased. To avoid the detection and tracking by modern IR-guided missiles, the aircraft and helicopters also demand progress in its stealth techniques. Hence, study of Infra-Red Signature Suppression (IRSS) systems in aircraft and helicopters has become vital even in design stage. Optical blocking (masking) is one of the effective IRSS techniques used to block the Line- Of-Sight (LOS) of the hot engine parts of the exhaust geometry. This paper reviews the various patents on IR signature suppression systems based on the optical blocking method or a combination of IRSS techniques. The performance penalties generated due to installation of various IRSS methods in aircraft and helicopters are also discussed.
文摘Geotechnical stability is a major concern for the long-term safety and integrity of underground infrastructures such as tunnels, railway stations, mine shafts and hydraulic power chambers. An effective geotechnical monitoring system is able to provide adequate warning to underground personnel prior to any unexpected major geotechnical failure. This paper reviews the conventional geotechnical monitoring sensors and the emerging Fibre Optic Sensing(FOS) techniques, pointing out their unique features and major differences. Recent advances in various FOS based monitoring systems, including Brillouin time domain distributed optical sensors and fibre Bragg grating(FBG) sensors, are investigated through a critical review of the laboratory studies and field applications used for underground geotechnical monitoring. Particular emphasis is given to fibre packaging, temperature compensation, installation methods and instrumentation performance in the underground environment. A detailed discussion of the advantages and limitations of each FOS monitoring system is also presented in this paper.
文摘To establish a theoretical basis for providing a better design method of multielement optical systems, we have developed a third-order geometric theory of a plane-symmetric multielement optical system that consists of a planar light source, an arbitrary number of ellipsoidal gratings, and an image plane. Analytic formulas of spot diagrams are derived for the system by analytically following a ray-tracing formalism. With these formulas, coma, spherical aberration, and resultant aberration are discussed. To make the theory practical, we determine the aberration coefficients numerically, rather than analytically, with the aid of ray tracing that takes into account the angular distribution of rays originating from a given light source. A merit function is defined so as to represent closely the variance of the spots formed when an infinite number of rays are traced and to take into account the dimensions of the source and the last optical element. The theory is also applicable to mirror-grating or mirror systems.
文摘We propose a scheme for realizing the optical nonreciprocal response based a four-mode optomechanical system,consisting of two charged mechanical modes and two linearly coupled optical modes. Two charged mechanical modes are coupled by Coulomb interaction, and two optical modes are coupled to one of mechanical modes by radiation pressure. We numerically evaluate the transmission probability of the probe field to obtain the optimum optical nonreciprocal response parameters. Also, we show that the optical nonreciprocal response is caused by the quantum interference between the optomechanical couplings and the linearly coupled interaction that breaks the time-reversal symmetry.
基金Project supported by the National Natural Science Foundation of China (Grant No 20505002)the Excellent Young Scholars Research Fund of Beijing Institute of Technology (Grant No 000Y06-23)the Excellent Scholars Research Fund of Beijing(Grant No 20071D1600300394)
文摘Optical tweezers have been a valuable research tool since their invention in the 1980s. One of the most important developments in optical tweezers in recent years is the creation of two-dimensional arrays of optical traps. In this paper, a method based on interference is discussed to form gradient laser fields, which may cause the spatial modulation of particle concentration. The parameters related to the optical tweezers array are discussed in detail and simulated by the Matlab software to show the influence of important parameters on the distribution of particle concentration. The spatial redistribution of particles in a laser interference field can also be predicted according to the theoretical analysis.
基金The National High Technology Research and Development Program of China(863 Program)(No.2013AA013601)the National Science and Technology M ajor Project of China(No.2015ZX03004009)
文摘In the intensity modulation and direct detection (IM/DD) multiple-input multiple-output (MIMO) optical wireless communication systems, a direct-current-biased adaptive modulation scheme is proposed to guarantee the nonnegative property of transmitted signals, and the MIMO channel is converted to a parallel channel by using a singular value decomposition. Besides, a QR decomposition and successive interference cancellation based adaptive modulation scheme is proposed, and the MIMO channel can be simplified to a parallel channel under the bit error ratio (BER) target constraint. The power is optimally allocated to each sub-channel to maximize the data rate. Simulation results show that the proposed adaptive modulation schemes can effectively improve the transmission rate of the systems under the BER target and constant optical power constraints. The proposed adaptive modulation schemes make use of the multiplexing gain of the MIMO techniques, and can further improve the spectrum efficiency of optical wireless systems.
基金supported by National Natural Science Foundation of China(Nos.61705064,11647122)the Natural Science Foundation of Hubei Province(Nos.2018CFB773,2018CFB672)the Project of the Hubei Provincial Department of Education(No.T201617)。
文摘A mobile fiber-optic laser-induced breakdown spectrometer(FO-LIBS) prototype was developed to rapidly detect a large quantity of steel material online and quantitatively analyze the trace elements in a large-diameter steel tube.Twenty-four standard samples and a polynomial fitting method were used to establish calibration curve models.The R^2 factors of the calibration curves were all above 0.99,except for Cu,indicating the elements’ strong self-absorption effect.Five special steel materials were rapidly detected in the steel mill.The average absolute errors of Mn,Cr,Ni,V,Cu,and Mo in the special steel materials were 0.039,0.440,0.033,0.057,0.003,and0.07 wt%,respectively,and their average relative errors fluctuated from 2.9% to 15.7%.The results demonstrated that the performance of this mobile FO-LIBS prototype can be compared with that of most conventional LIBS systems,but the more robust and flexible characteristics of the FO-LIBS prototype provide a feasible approach for promoting LIBS from the laboratory to the industry.
基金supported by the National Natural Science Foundation of China under Grant No.61975016the Science and Technology Project of Guangdong(2020B010190001)+2 种基金Natural Science Foundation of Beijing Municipality(1212013 and Z190006)Beijing Municipal Science&Technology Commission,Administrative Commission of Zhongguancun Science Park No.Z211100004821009Cultivation Project for Basic Research and Innovation of Yanshan University No.2021LGQN021.
文摘Micro-optical electromechanical systems(MOEMS)combine the merits of micro-electromechanical systems(MEMS)and micro-optics to enable unique optical functions for a wide range of advanced applications.Using simple external electromechanical control methods,such as electrostatic,magnetic or thermal effects,Si-based MOEMS can achieve precise dynamic optical modulation.In this paper,we will briefly review the technologies and applications of Si-based MOEMS.Their basic working principles,advantages,general materials and micromachining fabrication technologies are introduced concisely,followed by research progress of advanced Si-based MOEMS devices,including micromirrors/micromirror arrays,micro-spectrometers,and optical/photonic switches.Owing to the unique advantages of Si-based MOEMS in spatial light modulation and high-speed signal processing,they have several promising applications in optical communications,digital light processing,and optical sensing.Finally,future research and development prospects of Si-based MOEMS are discussed.
基金Jilin Province Science and Technology Development Plan Project(20190701024GH)。
文摘The measurement and control of high temperature play very important roles in national defense,military,scientific experiments,industrial and agricultural production.Photoelectric pyrometer is one of the important radiation thermometers for non-contact temperature measurement.It has an important application in the field of high temperature measurement,and its performance directly affects the accuracy of temperature measurement.By improving the design of the detection optical system of the photoelectric pyrometer,the imaging performance of the photoelectric pyrometer can be improved effectively,and the temperature measurement accuracy can be improved.In this paper,the temperature measurement principle of photoelectric pyrometer,the wo rking principle of the detection optical system and the composition of the system are introduced.The optical components that affect the imaging of the optical system of the photoelectric pyrometer are analyzed.The optical pyrometer detection optical system is simulated by ZEMAX software,based on the analysis results,the Modulation Transfer Function(MTF)and the spot Diagram are used as the main evaluation criteria to optimize the design of the objective lens of the photoelectric pyrometer detection optical system.The imaging performance of the photoelectric pyrometer detection optical system and the accuracy of temperature measurement of the photoelectric pyrometer are improved by optimization design of the detection optical system.