期刊文献+
共找到26篇文章
< 1 2 >
每页显示 20 50 100
Structural and optical analysis of Cr_2N thin films prepared by DC magnetron sputtering
1
作者 Shakil Khan A.Mahmood +3 位作者 A.Shah Qaiser Raza Muhammad Asim Rasheed Ishaq Ahmad 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2015年第2期197-202,共6页
Chromium nitride (Cr2N) thin films were prepared by a DC magnetron sputtering technique. The deposition temperature was raised from 50 to 300℃, and its influence on the film structure and refractive index was inves... Chromium nitride (Cr2N) thin films were prepared by a DC magnetron sputtering technique. The deposition temperature was raised from 50 to 300℃, and its influence on the film structure and refractive index was investigated. X-ray diffraction analysis shows that the crystalline strucure of the films transforms from the (101) to (002) oriented hexagonal CrzN phase as the increase of substrate tempera- ture above 50℃, and a highly texatred film grows at 100℃. An empirical relation between the crystalline orientation and infrared active modes of the films is obtained, i.e., the Fourier transform infrared (FTIR) spectrum of the film prepared at 50℃ exhibits only A1 (TO) mode. The prominent peak in the FTIR spectra of the film prepared above 50℃is assigned to the E1 (TO) mode and is correlated with the (002) or c-axis oriented hexagonal wurtzite phase of Cr2N. In the surface analysis of atomic force microscopy, a transformation from the featureless surface to columnar-type morphology is observed with the increase of substrate temperature from 50 to 100℃, exhibiting c-axis oriented crystallite growth. A further increase in substrate temperature to 200℃ causes the c-axis crystallites to merge, resulting in the formation of voids. The refractive index (n) of the deposited films is obtained using spectroscopic ellipsometry. 展开更多
关键词 chromium nitride thin films magnetron sputtering structural analysis optical analysis refractive index
下载PDF
Optical analysis method for fast plasma characterization of high-speed miniaturized synthetic jet
2
作者 袁野 张岩 +4 位作者 郭成 康小录 黄小平 严中 赵青 《Chinese Optics Letters》 SCIE EI CAS CSCD 2022年第7期41-46,共6页
In this paper,a new optical analysis method for plasma characterization is proposed.Plasma characteristics are obtained directly by measuring the plasma luminous color,rather than the complex spectral diagnosis method... In this paper,a new optical analysis method for plasma characterization is proposed.Plasma characteristics are obtained directly by measuring the plasma luminous color,rather than the complex spectral diagnosis method,which is difficult to obtain at high speed.By using the light transmittance curve of the human cornea,the RGB coordinates are calculated from the measured plasma spectrum data.Plasma characteristics are diagnosed using the Boltzmann plot method and the Stark broadening method.The corresponding relationship of the electron temperature,electron density data points,and luminous color is established and analyzed.Our research results indicate that this optical analysis method is feasible and promising for fast plasma characterization. 展开更多
关键词 optical analysis method plasma characteristics spectral diagnosis high-speed miniaturized actuator
原文传递
Evaluation of visual quality of spherical and aspherical intraocular lenses by Optical Quality Analysis System 被引量:11
3
作者 Yan Chen Xue Wang +1 位作者 Chuan-Di Zhou Qiang Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第6期914-918,共5页
AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four ... AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four eyes with age-related cataracts were randomly divided into spherical and aspherical lens implantation groups. Best-corrected visual acuity (BCVA) was measured preoperatively, one day, one week, two weeks, one month and two months after surgery. A biometric systems analysis using the OQAS objective scattering index (OSI) was performed. RESULTS: There were no significant differences in visual acuity (P〉0.05) before and after spherical and aspheric lens implantation. There was a negative linear correction between the OSI value and BCVA (t-=-0.634, P=-0.000), and positive corrections between the OSI value and the lens LOCUS III value of nucleus color (NC), nucleus opacity (NO), cortex (C) and posterior lens capsular (P) (r=0.704, P=0.000; r=0.514, P=0.000; r=0.276, P=0.020; r=0.417, P=-0.000, respectively). OSI values of spherical vs aspherical lenses were 11.5±3.6 vs 11.8±3.4, 4.1±0.9 vs 3.3±0.8, 3.5±0.9 vs 2.7±0.7, 3.3±0.8 vs 2.6±0.7, 3.2±0.7 vs 2.5±0.8, and 3.2±0.8 vs 2.50.8 before and ld, 1, 2wk, 1 and 2mo after surgery, respectively. All time points varied significantly (P〈0.01) between the two groups. CONCLUSION: Aspherical IOLs does not significantly affect visual acuity compared with spherical IOLs. The OSI value, was significantly lower in the aspherical lens group compared with the spherical lens. This study shows that objective visual quality of aspheric IOLs is better than that of the spherical lens by means of OQAS biological measurement method. 展开更多
关键词 optical quality analysis system age-relatedcataract spherical lens aspherical lens objective scatteringindex
下载PDF
Brillouin optical time-domain analysis for geotechnical monitoring 被引量:9
4
作者 L.Zeni L.Picarelli +6 位作者 B.Avolio A.Coscetta R.Papa G.Zeni C.Di Maio R.Vassallo A.Minardo 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2015年第4期458-462,共5页
In this paper, we show some recent experimental applications of Brillouin optical time-domain analysis (BOTDA) based sensors for geotechnical monitoring. In particular, how these sensors can be applied to detecting ... In this paper, we show some recent experimental applications of Brillouin optical time-domain analysis (BOTDA) based sensors for geotechnical monitoring. In particular, how these sensors can be applied to detecting early movements of soil slopes by the direct embedding of suitable fiber cables in the ground is presented. Furthermore, the same technology can be used to realize innovative inclinometers, as well as smart foundation anchors. 展开更多
关键词 Brillouin optical time-domain analysis(BOTDA)Tunnel engineeringDeformationDistributed monitoringHealth diagnosis
下载PDF
Theoretical Analysis of Retrieving Atmospheric Columnar Mie Optical Depth from Downward Total Solar Radiative Flux 被引量:1
5
作者 邱金桓 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 1989年第3期313-323,共11页
In this paper, the principle to determine the atmospheric columnar Mie optical depth from downward total solar radiative flux is theoretically studied, and the effect on Mie optical depth solution of the errors in sur... In this paper, the principle to determine the atmospheric columnar Mie optical depth from downward total solar radiative flux is theoretically studied, and the effect on Mie optical depth solution of the errors in surface albedo, sin-gle scattering albedo, asymmetrical factor of scattering phase function, instrumental constant and the approximate expression of diffusion flux is analy/ed, and then a method for determining surface albedo in shorter wavelength range is presented. 展开更多
关键词 Theoretical analysis of Retrieving Atmospheric Columnar Mie optical Depth from Downward Total Solar Radiative Flux
下载PDF
Beam Steering Analysis in Optically Phased Vertical Cavity Surface Emitting Laser Array
6
作者 荀孟 孙昀 +5 位作者 徐晨 解意洋 金智 周静涛 刘新宇 吴德馨 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第3期30-34,共5页
Beam steering in implant defined coherently coupled vertical cavity surface emitting laser (VCSEL) arrays is simulated using the FDTD solution software. Angular deflection dependent on relative phase differences amo... Beam steering in implant defined coherently coupled vertical cavity surface emitting laser (VCSEL) arrays is simulated using the FDTD solution software. Angular deflection dependent on relative phase differences among elements, inter-element spacing, element size and emitted wavelength is analyzed detailedly and systematically. We design and fabricate 1×2 implant defined VCSEL arrays for optimum beam steering performance. Electroni- cally controlled beam steering with a maximum deflection angle of 1.6° is successfully achieved in the 1 × 2 VCSEL arrays. The percentage of the power in the central lobe is above 39% when steering. The results show that the steering is controllable. Compared with other beam steering methods, the fabrication process is simple and of low cost. 展开更多
关键词 VCSEL Beam Steering analysis in optically Phased Vertical Cavity Surface Emitting Laser Array
下载PDF
Effect of low-degree astigmatism on the objective visual quality
7
作者 Ling-Ying Ye Shu-Feng Li +2 位作者 Jing-Jing Zuo Jin Li Hui-Xiang Ma 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第6期1086-1093,共8页
AIM:To evaluate the effect of low-degree astigmatism on objective visual quality through the Optical Quality Analysis System(OQAS).METHODS:This study enrolled 46 participants(aged 23 to 30y,90 eyes)with normal or corr... AIM:To evaluate the effect of low-degree astigmatism on objective visual quality through the Optical Quality Analysis System(OQAS).METHODS:This study enrolled 46 participants(aged 23 to 30y,90 eyes)with normal or corrected-to-normal vision.The cylindrical lenses(0,0.5,0.75,1.0,and 1.25 D)were placed at the axial direction(180°,45°,90°,and 135°)in front of the eyes with the best correction to form 16 types of regular low-degree astigmatism.OQAS was used to detect the objective visual quality,recorded as the objective scattering index(OSI),OQAS values at contrasts of 100%,20%,and 9%predictive visual acuity(OV100%,OV20%,and OV9%),modulation transfer function cut-off(MTFcut-off)and Strehl ratio(SR).The mixed effect linear model was used to compare objective visual quality differences between groups and examine associations between astigmatic magnitude and objective visual quality parameters.RESULTS:Apparent negative relationships between the magnitude of low astigmatism and objective visual quality were observed.The increase of OSI per degree of astigmatism at 180°,45°,90°,and 135°axis were 0.38(95%CI:0.35,0.42),0.50(95%CI:0.46,0.53),0.49(95%CI:0.45,0.54)and 0.37(95%CI:0.34,0.41),respectively.The decrease of MTFcut-off per degree of astigmatism at 180°,45°,90°,and 135°axis were-10.30(95%CI:-11.43,-9.16),-12.73(95%CI:-13.62,-11.86),-12.75(95%CI:-13.79,-11.70),and-9.97(95%CI:-10.92,-9.03),respectively.At the same astigmatism degree,OSI at 45°and 90°axis were higher than that at 0°and 135°axis,while MTFcut-off were lower.CONCLUSION:Low astigmatism of only 0.50 D can significantly reduce the objective visual quality. 展开更多
关键词 low-degree astigmatism objective visual quality optical Quality analysis System
下载PDF
Optical Measurements to Reveal Roles of Slightly Crosslinked Poly (dimethyldiallylammonium chloride) s in Fixing Anionic Dyes on Cotton Fabric
8
作者 余义开 张跃军 《Journal of Donghua University(English Edition)》 EI CAS 2015年第3期504-509,共6页
The roles of slightly crosslinked poly( dimethyldiallylammonium chloride) s( PDMDAACs) in fixing anionic dyes on cotton fabric were verified more precisely by optical analysis technologies,to achieve the new theoretic... The roles of slightly crosslinked poly( dimethyldiallylammonium chloride) s( PDMDAACs) in fixing anionic dyes on cotton fabric were verified more precisely by optical analysis technologies,to achieve the new theoretical guides for the widely applications. Firstly,one method of optical CIELAB color difference analysis was designed to exactly measure the values of dyefixing performances, so that the suitable molecular weights and structures of the slightly crosslinked PDMDAACs could be precisely confirmed to play a role in the development of their dye-fixing performances. Secondly,the FT-IR absorption shift of the dye on dyed cotton sample fixed by slightly crosslinked PDMDAACs was nearly in agreement with that of forming water-insoluble color lakes,indicating that the expected color lakes could be formed on dyed cotton fabric,and would play a role in further development of the fastness of dyes on cotton fabric. Thirdly,the FT-IR spectra of fixed undyed cotton samples and that of fixed dyed cotton samples both showed the absorptions of slightly crosslinked PDMDAACs,further revealing that the slightly crosslinked PDMDAACs could be penetrated into cotton fabric and be convenient to interact with dyes when fixing. However,those absorptions of the slightly crosslinked PDMDAACs fixed on cotton samples would be absent after being adequately washed to a constant weight,suggesting that the fixing interactions of the slightly crosslinked PDMDAAC and cotton fabric were very weak. 展开更多
关键词 optical analysis technologies slightly crosslinking poly(dimethyldiallylammonium chloride) s(PDMDAACs) cationic copolymer color lakes cotton fabric
下载PDF
Optical quality of toric intraocular lens implantation in cataract surgery 被引量:8
9
作者 Xian-Wen Xiao Jing Hao +1 位作者 Hong Zhang Fang Tian 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第1期66-71,共6页
AIM: To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system.METHODS: Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D ... AIM: To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system.METHODS: Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D underwent implantation of Acry Sof toric intraocular lens, including T3 group 19 eyes, T4 group 18 eyes, T5 group 10 eyes,T6 group 5 eyes. Main outcomes evaluated at 3mo of follow-up, included uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), residual refractive cylinder and intraocular lens(IOL) axis rotation.Objective optical quality were measured using optical quality analysis system(OQAS Ⅱ, Visiometrics, Spain),included the cutoff frequency of modulation transfer function(MTFcutoff), objective scattering index(OSI),Strehl ratio, optical quality analysis system value(OV)100%, OV 20% and OV 9% [the optical quality analysis system(OQAS) values at contrasts of 100%, 20%, and 9%].RESULTS: At 3mo postoperative, the mean UDVA and CDVA was 0.18 ±0.11 and 0.07 ±0.08 log MAR; the mean residual refractive cylinder was 0.50 ±0.29 D; the mean toric IOL axis rotation was 3.62 ±1.76 degrees, the mean MTFcutoff, OSI, Strehl ratio, OV 100%, OV 20% and OV9% were 22.862 ±5.584, 1.80 ±0.84, 0.155 ±0.038, 0.76 ±0.18,0.77±0.19 and 0.78±0.21. The values of UDVA, CDVA, IOL axis rotation, MTFcutoff, OSI, Strehl ratio, OV100%,OV20% and OV9% depending on the power of the cylinder of the implantation were not significantly different(P 】0.05), except the residual refractive cylinder(P 【0.05).CONCLUSION: The optical quality analysis system was useful for characterizing the optical quality of Acry Sof toric IOL implantation. Implantation of an Acry Sof toric IOL is an effective and safe method to correct corneal astigmatism during cataract surgery. 展开更多
关键词 optical quality analysis system toric intraocular lens ASTIGMATISM
下载PDF
Investigation on performance of all optical buffer with large dynamical delay time based on cascaded double loop optical buffers
10
作者 王拥军 吴重庆 +2 位作者 忻向军 余贶琭 张晓磊 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第9期420-427,共8页
Optical buffers are critical for optical signal processing in future optical packet-switched networks. In this paper, a theoretical study as well as an experimental demonstration on a new optical buffer with large dyn... Optical buffers are critical for optical signal processing in future optical packet-switched networks. In this paper, a theoretical study as well as an experimental demonstration on a new optical buffer with large dynamical delay time is carried out based on cascaded double loop optical buffers (I:)LOBs). It is found that pulse distortion can be restrained by a negative optical control mode when the optical packet is in the loop. Noise analysis indicates that it is feasible to realise a large variable delay range by cascaded DLOBs. These conclusions are validated by the experiment system with 4-stage cascaded DLOBs. Both the theoretical simulations and the experimental results indicate that a large delay range of 1-9999 times the basic delay unit and a fine granularity of 25 ns can be achieved by the cascaded DLOBs. The performance of the cascaded DLOBs is suitable for the all optical networks. 展开更多
关键词 all optical packets switching optical buffer with large delay range signals impairment noise analysis of semiconductor optical amplifier
下载PDF
STUDIES ON CRITICAL CONCENTRATION OF LIQUID CRYSTALLINE ETHYLCELLULOSE
11
作者 董炎明 张世英 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 1996年第2期134-141,共8页
Critical concentrations of lyotropic liquid crystalline ethylcellulose in more than ten solvents were determined using both Abbe refractometer and polarized microscopy. Critical concentration C-crit of forming Liquid ... Critical concentrations of lyotropic liquid crystalline ethylcellulose in more than ten solvents were determined using both Abbe refractometer and polarized microscopy. Critical concentration C-crit of forming Liquid crystal phase decreased with increasing solubility parameter delta of solvent until approaching the delta of polymer. Although the alcohols used as solvents had the same variation rule, the critical concentration values of their solutions were much higher, due to their excessive large hydrogen bond component of delta. The experiments of using mixed solvents which showed good linear relation between C-crit and delta also proved this rule. A technique of Transmission Optical Analysis was first used to estimate the concentration dependence of critical phase transition temperature T-crit of EC, and a T-C phase diagram could be drawn. 展开更多
关键词 ethyl cellulose lyotropic liquid crystal critical concentration solubility parameter Transmission optical analysis phase diagram
下载PDF
Spectroscopic Measurements of Impurity Spectra on the EAST Tokamak 被引量:1
12
作者 FU Jia LI Yingying +6 位作者 SHI Yuejiang WANG Fudi ZHANG Wei LV Bo HUANG Juan WAN Baonian ZHOU Qian 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第12期1048-1053,共6页
Ultraviolet (UV) and visible impurity spectra (200-750 nm) are commonly used to study plasma and wall interactions in magnetic fusion plasmas. Two optical multi-channel analysis (OMA) systems have been installed... Ultraviolet (UV) and visible impurity spectra (200-750 nm) are commonly used to study plasma and wall interactions in magnetic fusion plasmas. Two optical multi-channel analysis (OMA) systems have been installed for the UV-visible spectrum measurement on EAST. These two OMA systems are both equipped with the Czerny-Turner (C-T) type spectrometer. The upper vacuum vessel and inner divertor baffle can be viewed simultaneously through two optical lenses. The OMA1 system is mainly used for multi-impurity lines radiation measurement. A 280 nm wavelength range can be covered by a 300 mm focal length spectrometer equipped with a 300 grooves/mm grating. The Da/Ha line shapes can be resolved by the OMA2 system. The focal length is 750 mm. The spectral resolution can be up to 0.01 nm using a 1800 grooves/mm grating. The impurity behaviour and hydrogen ratio evolution after boroniztion, lithium coating, and siliconization are compared. Lithium coating has shown beneficial effects on the reduction of edge recycling and low Z impurity (C, O) influx. The impurity expelling effect of the divertor configuration is also briefly discussed through multi-channels observation of OMA1 system. 展开更多
关键词 OMA optical multi channel analysis BORONIZATION lithium coating wall condition TOKAMAK
下载PDF
Preparation and characterization of γ-La_2S_3 nanoparticles from thermal decomposition 被引量:2
13
作者 Pei-sen Li Huan-yong Li Wan-qi Jie 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2011年第6期748-752,共5页
To synthesize pure γ-La2S3 at lower temperature,lanthanide complex La(Et2S2CN)3·phen,containing La?S bond,was chosen as the precursors to decompose.The obtained samples were characterized by X-ray power diffr... To synthesize pure γ-La2S3 at lower temperature,lanthanide complex La(Et2S2CN)3·phen,containing La?S bond,was chosen as the precursors to decompose.The obtained samples were characterized by X-ray power diffraction (XRD),field-emission scanning electron microscopy (FE-SEM) with an energy dispersive spectrometer and UV-Vis diffuse reflectance spectra.The decomposition mechanism of the lanthanide complex was studied by thermogravimetric analyses (TGA).The results show that the obtained samples are cubic phase particles with sizes among 20-50 nm and the band gap is 2.97 eV,which is bigger than that of its bulk crystal.TG/DTG results indicate that La(Et2S2CN)3·phen decomposed to γ-La2S3 via La4(Et2S2CN)3 as an intermediate product. 展开更多
关键词 chalcogenides nanoparticles thermogravimetric analysis decomposition optical properties
下载PDF
Performance analysis of chip-asynchronous coherent time-spreading optical CDMA system 被引量:1
14
作者 吉建华 吴青 +1 位作者 龚方平 徐铭 《Optoelectronics Letters》 EI 2009年第1期30-33,共4页
Multiple-access interference(MAI) and beat noise(BN) in chip-asynchronous coherent time-spreading OCDMA system are evaluated by the aperiodic cross-correlation function of up-sampled sequence.Relationship between the ... Multiple-access interference(MAI) and beat noise(BN) in chip-asynchronous coherent time-spreading OCDMA system are evaluated by the aperiodic cross-correlation function of up-sampled sequence.Relationship between the mean intensity of aperiodic cross-correlation and MAI and BN is deduced,and then the relationship between BER and mean intensity of aperiodic cross-correlation is discussed.For 127-long gold sequence,mean BER performance of chip-asynchronous coherent time-spreading OCDMA is derived and compared with that of the chip-synchronous system.It can be shown that the chip-synchronous assumption provides a performance upper limit.For realistic asynchronous coherent time-spreading OCDMA system,BER will reduce by about one order of magnitude. 展开更多
关键词 OCDMA TIME Performance analysis of chip-asynchronous coherent time-spreading optical CDMA system
原文传递
Spectroscopic Measurement of Neutral Particle Influx Ratio on EAST
15
作者 李颖颖 符佳 +8 位作者 石跃江 张伟 沈永才 王福地 吕波 黄娟 张凌 徐经翠 周倩 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第6期493-498,共6页
The spectra of HeI(587.6 nm),Hα(656.28 nm) and Dα(656.1 nm) of the helium discharges as well as the normal deuterium discharges have been measured with two optical spectroscopic multi-channel analysis(OMA) s... The spectra of HeI(587.6 nm),Hα(656.28 nm) and Dα(656.1 nm) of the helium discharges as well as the normal deuterium discharges have been measured with two optical spectroscopic multi-channel analysis(OMA) systems on the experimental advanced superconducting tokamak(EAST).The influx ratio of the sum of H and D to He spectral lines and the influx ratio of H to D are given.In this way the ratio of hydrogen/deuterium ion(S/X B)H/D to(S/X B)He as well as(S/X B)H/D is not very sensitive to the variation in the edge density and temperature. The low-density helium discharges are operated in order to reduce the recycling hydrogen fluxes; however,the effect is not obvious.The possible reason is that the number of helium discharges is not enough and the content of hydrogen in the wall is still very abundant,which is caused by frequent wall conditionings and the vacuum leakage.The H/(H+D) ratio decreases quickly after one lithium coating and reduces to less than 10%using several accumulated lithium wall conditioning.It is found that the deposited He atoms on the carbon wall will remain at a low level after several D2 discharges. 展开更多
关键词 optical spectroscopic multi-channel analysis(OMA) INFLUX helium discharges lithium
下载PDF
Performance analysis of optical burst switching under bursty traffic
16
作者 陈春汉 曹明翠 罗志详 《Chinese Optics Letters》 SCIE EI CAS CSCD 2004年第1期21-23,共3页
The performance of the algorithm of the data channel scheduling algorithm of latest available unscheduled channel with void filling (LAUC-VF) under bursty traffic is presented firstly. A bursty traffic model for optic... The performance of the algorithm of the data channel scheduling algorithm of latest available unscheduled channel with void filling (LAUC-VF) under bursty traffic is presented firstly. A bursty traffic model for optical burst switch performance simulation is also introduced. 展开更多
关键词 Performance analysis of optical burst switching under bursty traffic OBS LINE FDL LENGTH
原文传递
Performance analysis of an integrated scheme in optical burst switching high-speed networks
17
作者 Amit Kumar Garg R.S.Kaler 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第4期244-247,共4页
A new integrated scheme based on resource-reservation and adaptive network flow routing to alleviate contention in optical burst switching networks is proposed. The objective of the proposed scheme is to reduce the ov... A new integrated scheme based on resource-reservation and adaptive network flow routing to alleviate contention in optical burst switching networks is proposed. The objective of the proposed scheme is to reduce the overall burst loss in the network and at the same time to avoid the packet out-of-sequence arrival problem. Simulations are carried out to assess the feasibility of the proposed scheme. Its performance is compared with that of contention resolution schemes based on conventional routing. Through extensive simulations, it is shown that the proposed scheme not only provides significantly better burst loss performance than the basic equal proportion and hop-length based traffic routing algorithms, but also is void of any packet re-orderings. 展开更多
关键词 rate NODE Performance analysis of an integrated scheme in optical burst switching high-speed networks OBS length
原文传递
Intra-Cavity Absorption Sensors for Gas Detection Using Wavelength Sweep Technique
18
作者 Kun Liu Wen-Cai Jing +6 位作者 Gang-Ding Peng Jian-Zhong Zhang Yan Wang Tie-Gen Liu Da-Gong Jia Hong-Xia Zhang Yi-Mo Zhang 《Journal of Electronic Science and Technology of China》 2008年第4期369-372,共4页
Wavelength sweep technique (WST) is introduced into intra-cavity fiber laser (ICFL) for low concentration gas detection. The limitation induced by noise can be eliminated using this method, and the performance of ... Wavelength sweep technique (WST) is introduced into intra-cavity fiber laser (ICFL) for low concentration gas detection. The limitation induced by noise can be eliminated using this method, and the performance of the system is improved. The sensitivity of the system is reduced to less than 300 ppm. With WST, sweeping characteristic of the ICFL can be described according to known gas absorption spectra. 展开更多
关键词 Gas detection optical fiber laser spectrum analysis wavelength measurement.
下载PDF
Bioanalysis in single cells: current advances and challenges
19
作者 Hong-Yuan Chen 《Science China Chemistry》 SCIE EI CAS CSCD 2020年第5期564-588,共25页
Cells, basic units of living structures and functions, build up a complicated small world, and their order and complexity resemble a small universe. The detailed understanding and elucidation of the matter transport a... Cells, basic units of living structures and functions, build up a complicated small world, and their order and complexity resemble a small universe. The detailed understanding and elucidation of the matter transport and energy conversion mechanisms within a single cell will expand our knowledge about the origin and evolution of life, the disease mechanisms and much more. In past decades, single-cell analysis has been rapidly and significantly improved and various methodologies have been developed to reveal the complexity of mass, energy, and information within single cells. In this review, we focused on the methods developed in recent years for single-cell analysis, including electrochemical method, optical method, and mass spectrometry method. We reviewed the recent advances and representative studies in this research field, and also discussed the strengths and limitations of each method. Finally, we presented the existing technical challenges and further directions for single-cell analysis. 展开更多
关键词 BIOanalysis single-cell electrochemistry single-cell optical analysis single-cell mass spectrometry
原文传递
ANALYSIS OF THE CHAOTIC DYNAMICS OF A HIGH-FLUX CFB RISER USING SOLIDS CONCENTRATION MEASUREMENTS 被引量:1
20
作者 S. V. Manyele J.-X. Zhu +1 位作者 R. E. Khayat J. H. Parssinen 《China Particuology》 SCIE EI CAS CSCD 2006年第3期136-146,共11页
A high-flux circulating fluidized bed (CFB) riser (0.076-m I.D. and 10-m high) was operated in a wide range of operating conditions to study its chaotic dynamics, using FCC catalyst particles (dp= 67μm, ρp = 15... A high-flux circulating fluidized bed (CFB) riser (0.076-m I.D. and 10-m high) was operated in a wide range of operating conditions to study its chaotic dynamics, using FCC catalyst particles (dp= 67μm, ρp = 1500 kg·m^-3). Local solids concentration fluctuations measured using a reflective-type fiber optic probe were processed to determine chaotic invariants (Kolmogorov entropy and correlation dimension), Radial and axial profiles of the chaotic invariants at different operating conditions show that the core region exhibits higher values of the chaotic invariants than the wall region. Both invariants vary strongly with local mean solids concentration. The transition section of the riser exhibits more complex dynamics while the bottom and top sections exhibit a more uniform macroscopic and less-complex microscopic flow structure. Increasing gas velocity leads to more complex and less predictable solids concentration fluctuations, while increasing solids flux generally lowers complexity and increases predictability. Very high solids flux, however, was observed to increase the entropy. 展开更多
关键词 high-flux riser concentration fiber optic probe chaos analysis correlation dimension Kolmogorov entropy
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部