期刊文献+
共找到9篇文章
< 1 >
每页显示 20 50 100
Analysis on Lightning Strike Cause of Directly Buried Optical Cable in Wind Farm and Its Prevention Methods 被引量:3
1
作者 Yan YANG Zhen CHEN +3 位作者 Yixian QIU Yu HUANG Qiaobin WEI Shaojie YANG 《Meteorological and Environmental Research》 CAS 2022年第3期67-70,共4页
Directly buried metal optical cable is a form of erecting optical fiber ring network communication system in wind farms. Although the directly buried optical cable is much less than the overhead optical cable affected... Directly buried metal optical cable is a form of erecting optical fiber ring network communication system in wind farms. Although the directly buried optical cable is much less than the overhead optical cable affected by lightning, sometimes lightning damaging optical cable and flashover discharge accidents of optical cable port occurred. In this paper, the amplitude spectrum of lightning wave, the breakdown depth and breakdown distance of lightning wave to soil, the metal components of optical cable port and the impedance characteristics of grounding wire are systematically analyzed, and the prevention methods of directly buried optical cable in wind farm to avoid lightning damage are proposed. 展开更多
关键词 Wind farm Directly buried optical cable Lightning stroke accident Prevention method
下载PDF
Optical Cable Telecommunication Networks
2
《China's Foreign Trade》 1995年第8期32-33,共2页
1. Southern Coastal Optical Cable Engineering Project. The cable was completed and put into operation in 1992, and has a total length of 2,800km, starting from Nanjing in the north, via Shanghai, Hangzhou, Fuzhou, Xia... 1. Southern Coastal Optical Cable Engineering Project. The cable was completed and put into operation in 1992, and has a total length of 2,800km, starting from Nanjing in the north, via Shanghai, Hangzhou, Fuzhou, Xiamen, Huizhou, leading to Guangzhou in the south, covering Jiangsu, Shanghai, Zhejiang, Fujian and Guangdong. The whole line has 展开更多
关键词 LENGTH optical cable Telecommunication Networks
下载PDF
Huiyuan ADSS Optical Cable
3
《China's Foreign Trade》 1999年第1期40-40,共1页
关键词 ADSS Huiyuan ADSS optical cable
下载PDF
A New Optical Cable Communications Project
4
作者 Huo Tongying 《China's Foreign Trade》 1995年第10期24-24,共1页
A key project of the state, the Beijing-Taiyuan-Xi’an optical cable communications trunk, is one of the 22 optical cables planned to be laid by the Ministry of Post and Telecommunications during the Eighth Five Year.... A key project of the state, the Beijing-Taiyuan-Xi’an optical cable communications trunk, is one of the 22 optical cables planned to be laid by the Ministry of Post and Telecommunications during the Eighth Five Year. Plan. This communication cable trunk covers a distance of 1771 km, starting from Beijing and going via Hebei and Shanxi to Xi’an in Shaanxi, linking two provincial capitals, one municipality directly under the jurisdiction of the central government, seven other cities and 32 counties. 展开更多
关键词 A New optical cable Communications Project LINE
下载PDF
Theoretical Analysis of Measurement in Operation Efficiency in Optical Cable Transmission Networks
5
作者 LIUGuo-liang ZHAOYing-cai 《The Journal of China Universities of Posts and Telecommunications》 EI CSCD 2000年第1期60-66,共7页
关键词 transmission network logic circuit path system optical cable fiber core operation efficiency circuit merging
原文传递
全绝缘自支撑电缆系统设计(英文) 被引量:1
6
作者 George G.Karady Kumaraguru Prabakar 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2715-2720,共6页
All-dielectric self-supporting(ADSS) cables are installed along with transmission line for the purpose of communication.During installation the outer layer of the cable is hydrophobic and is not prone to dry band arci... All-dielectric self-supporting(ADSS) cables are installed along with transmission line for the purpose of communication.During installation the outer layer of the cable is hydrophobic and is not prone to dry band arcing. These cables become less hydrophobic over time and become vulnerable to dry band arcing.This loss in hydrophobicity is because of the contamination formed on the outer layer due to pollution.This is one of the reasons which cause cable failure.Considerable amount of losses will be incurred on the occurrence of a cable failure as the cables are also leased to other companies.An improved equivalent circuit is used to calculate the voltage and current distribution of the double circuit line.A three-phase single circuit line and a three-phase double circuit line are used to calculate their corresponding voltage distribution and current distribution.The results could be used to predict dry band arcing on similar models.The method used considers sag,span and pollution on ADSS cable. 展开更多
关键词 dry band arcing all-dielectric self-supporting cable fiber optic cable voltage distribution current distribution all-dielectric self-supporting circuit simulation
下载PDF
The Analysis of Angle Resolution of Stress Vector Sensor Based on Optical Fiber Sensing Cable for High Speed Railway Traffic
7
作者 邓顺戈 马鑫 李新碗 《Journal of Shanghai Jiaotong university(Science)》 EI 2018年第1期61-65,共5页
With the development of high speed railway traffic, the structure health monitoring for high-speed rail is necessary due to the safety issue. Optical fiber sensing technology is one of the options to solve it. Stress ... With the development of high speed railway traffic, the structure health monitoring for high-speed rail is necessary due to the safety issue. Optical fiber sensing technology is one of the options to solve it. Stress vector information is the important index to make more reasonable judgments about railway safety. However, information sensed by lots of commercial optical sensors is scalar. According to the stress filed distribution of rail, this paper proposes a new type of stress vector sensor based on optical fiber sensing cable(OFSC) with a symmetrical seven optical fibers structure and analyzes the relations between angle resolution and distance between adjacent of optical fibers through finite-element software(ANSYS) simulation. Through reasonable distance configuration, the angle resolution of the OFSC can be improved, and thus stress vector information, including the stress magnitude and the angle of stress, can be more accurately obtained. The simulation results are helpful to configure OFSC for angle resolution improvement in actual practice, and increase the safety factor in high speed railway structure health monitoring. 展开更多
关键词 optical fiber sensing cable RAIL angle resolution stress finite element analysis
原文传递
Application of Golay codes to distributed optical fiber sensor for long-distance oil pipeline leakage and external damage detection 被引量:6
8
作者 王延年 蒋庄德 《Chinese Optics Letters》 SCIE EI CAS CSCD 2006年第3期141-144,共4页
A new distributed optical fiber sensor system for long-distance oil pipeline leakage and external damage detection is presented. A smart and sensitive optical fiber cable is buried beneath the soil running along the o... A new distributed optical fiber sensor system for long-distance oil pipeline leakage and external damage detection is presented. A smart and sensitive optical fiber cable is buried beneath the soil running along the oil pipeline, which is sensitive to soakage of oil products and mechanical deformation and vibration caused by leaking, tampering, and mechanical impacting. The region of additional attenuation can be located based on the optical time domain reflectometry (OTDR), and the types of external disturbances can be identified according to the characteristics of transmitted optical power. The Golay codes are utilized to improve the range-resolution performance of the OTDR sub-system and offer a method to characterize the transmitted optical power in a wide range of frequency spectrum. Theoretic analysis and simulation experiment have shown that the application of Golay codes can overcome the shortcomings of the prototype based on the conventional single-pulse OTDR. 展开更多
关键词 ATTENUATION DEFORMATION Leak detection optical cables optical fibers Pipelines SIMULATION Time domain analysis Vibrations (mechanical)
原文传递
An Accurate and Safe Small Raman Gain Measurement for Installed Fiber Optic Cables
9
作者 Takayuki Miyakawa Yasuyuki Nagao 《光学学报》 EI CAS CSCD 北大核心 2003年第S1期571-572,共2页
Novel small Raman gain measurement method for installed fiber optic cables using a modulated pump light is proposed. We have demonstrated accurate Raman gain measurement in small Raman gain less than 1dB and we also m... Novel small Raman gain measurement method for installed fiber optic cables using a modulated pump light is proposed. We have demonstrated accurate Raman gain measurement in small Raman gain less than 1dB and we also measured Raman gain for the installed fiber optic cable by using average pumping power of about only 25mW. 展开更多
关键词 for in as In BE An Accurate and Safe Small Raman Gain Measurement for Installed Fiber Optic cables FRA of
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部