期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Precise Optical Fiber Length Measurement System Based on Fresnel Reflection
1
作者 Firat Ertac Durak Arif Basgumus +1 位作者 Serif Ali Sadik Ahmet Altuncu 《Journal of Electrical Engineering》 2016年第3期128-132,共5页
In this study, a precise optical fiber length measurement system is proposed. The measurement technique is based on the measurement of relative Fresnel reflected light intensity in a test fiber. Time delayed optical r... In this study, a precise optical fiber length measurement system is proposed. The measurement technique is based on the measurement of relative Fresnel reflected light intensity in a test fiber. Time delayed optical reflected pulses are obtained from a single nanosecond pulse injected at the input due to the difference in lengths of the reference and test fibers. The lengths of the different optical fibers have been measured with this technique with high resolution and fast response time. The measured results show that, the proposed technique has a comparable performance with the well-known length measurement systems. 展开更多
关键词 Fresnel reflection nanosecond pulse optical fiber length measurement time delayed pulses.
下载PDF
High-precision group-delay dispersion measurements of optical fibers via fingerprint-spectral wavelength-to-time mapping 被引量:2
2
作者 Takashi Ito Ondrej Slezak +2 位作者 Masahiro Yoshita Hidefumi Akiyama Yohei Kobayashi 《Photonics Research》 SCIE EI 2016年第1期13-16,共4页
The group-delay dispersion of an optical fiber was measured with the time-of-flight method, using fingerprint-like characteristic spectra from a mode-locked fiber laser source. To determine the group-delay dispersion ... The group-delay dispersion of an optical fiber was measured with the time-of-flight method, using fingerprint-like characteristic spectra from a mode-locked fiber laser source. To determine the group-delay dispersion up to the fourth order, least-squares fitting was applied to the overall time waveform mapped on the time axis for the fingerprint-spectral broadband pulses through a long optical fiber. The analysis of all 4003 data points reduced statistical uncertainty, and provided second-, third-, and fourth-order dispersion with uncertainties of 0.02%, 0.4%, and 4%,respectively. 展开更多
关键词 length time High-precision group-delay dispersion measurements of optical fibers via fingerprint-spectral wavelength-to-time mapping
原文传递
Optical Fiber Sensor's Applied in Vibration Measurement of Turbine Blade
3
作者 Fajie Duan, Zhiqiang Fang, Yuyang Sun State Key Lab of Precision Measuring Technology & Instruments, Tianjin University, P. R. China 《光学学报》 EI CAS CSCD 北大核心 2003年第S1期823-824,共2页
A new type optical fiber sensor--Tip timing Sensor is introduced in this paper. It is mostly used in vibration measurement of turbine blade, which can realize real-time and non-contact measurement.
关键词 of AS optical fiber Sensor’s Applied in Vibration measurement of Turbine Blade in
原文传递
An Accurate and Safe Small Raman Gain Measurement for Installed Fiber Optic Cables
4
作者 Takayuki Miyakawa Yasuyuki Nagao 《光学学报》 EI CAS CSCD 北大核心 2003年第S1期571-572,共2页
Novel small Raman gain measurement method for installed fiber optic cables using a modulated pump light is proposed. We have demonstrated accurate Raman gain measurement in small Raman gain less than 1dB and we also m... Novel small Raman gain measurement method for installed fiber optic cables using a modulated pump light is proposed. We have demonstrated accurate Raman gain measurement in small Raman gain less than 1dB and we also measured Raman gain for the installed fiber optic cable by using average pumping power of about only 25mW. 展开更多
关键词 for in as In BE An Accurate and Safe Small Raman Gain measurement for Installed fiber Optic Cables FRA of
原文传递
Experimental measurements of gas-solid flow and splitting mechanisms of a coal pipe splitter with a perpendicularly arranged upstream elbow
5
作者 Hao Zhou Yan Huang +3 位作者 Yu Yang Guiyuan Mo Jianzhong Li Kefa Cen 《Particuology》 SCIE EI CAS CSCD 2016年第2期143-150,共8页
The effect of the vertical pipe length on the performance of a coal pipe splitter with a perpendicularly arranged upstream elbow was investigated experimentally employing a fiber optic measuring system. The upstream e... The effect of the vertical pipe length on the performance of a coal pipe splitter with a perpendicularly arranged upstream elbow was investigated experimentally employing a fiber optic measuring system. The upstream elbow and coal pipe splitter were installed in two perpendicular planes. Contours of dis- tributions of the particle concentration and size were obtained in different transverse sections. The experimental data show that the maximum/minimum concentration ratio in transverse sections A, B, and C decreased rapidly as the length of the vertical pipe increased. The left/right-leg average concentration ratio remained about 1, and a balanced split was thus achieved. With a perpendicularly arranged upstream elbow, the vertical pipe length had little effect on the splitter performance, which is beneficial for engineering design and convenient for industrial application. 展开更多
关键词 Gas-solid flow Concentration measurement Coal pipe splitter fiber optic sensor
原文传递
Inner wall running state monitoring for the main pipe of nuclear power 被引量:1
6
作者 ZHANG YuCun ZHOU Shan FU XianBin 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第10期2606-2614,共9页
The heat conduction equation is solved in this paper under specific boundary conditions.The coefficients of the obtained distribution equation are simplified with the piecewise integral method.Then the associated mode... The heat conduction equation is solved in this paper under specific boundary conditions.The coefficients of the obtained distribution equation are simplified with the piecewise integral method.Then the associated model for the cylindrical thermal equipment is established.The relationship of the surface temperatures,the material properties and the inner wall state of the cylindrical thermal equipment is described in the associated model.This model is applied to the inner wall running state monitoring of the main pipe.A multi-channel distributed optical fiber temperature measurement system is designed to acquire the external surface temperatures of the main pipe.Then the associated model can be used to analyze the surface temperature data of the main pipe.The location and the physical dimension of the inner wall defect can be got.Therefore,the inner wall defect monitoring of the main pipe can be realized.The feasibility of this method is verified by experiment.This method also provides a theoretical basis for the real-time monitoring of the main pipe’s internal state. 展开更多
关键词 inner wall defect running state monitoring multi-channel distributed optical fiber temperature measurement mainpipe of nuclear power
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部