期刊文献+
共找到63篇文章
< 1 2 4 >
每页显示 20 50 100
Optical Instruments and Components
1
《光机电信息》 2005年第12期44-47,共4页
关键词 LENGTH Co YAG STAR optical instruments and Components www nm high FWHM http SBP
下载PDF
Optical Instruments and Components
2
《光机电信息》 2006年第6期80-82,共3页
关键词 YAG Co LENGTH optical instruments and Components www PCV nm PV SBP
下载PDF
Optical Instruments and Components
3
《光机电信息》 2005年第4期55-57,共3页
Beijing Optical Instrument Plant;Penglai Yuandong Optical Elements Co., Ltd.;Beijing Zolix Optical Instrunments Co.,Ltd,;Beijing Huawei Haorun Device Co., Ltd.;
关键词 MTS LENGTH optical instruments and Components
下载PDF
The Application of Permanent Magnet Synchronous Motor with Small Electrical Time Constant in Fiber Positioner
4
作者 Shaoxiong Guo Yan Yang +3 位作者 Yanbin Yin Yihu Tang Yang Tian Chao Zhai 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2024年第1期212-222,共11页
With the development of cutting-edge multi-object spectrographs,fiber positioners located in the focal plane are being scaled down in size,and miniature hollow-cup Permanent Magnet motors are now being considered as a... With the development of cutting-edge multi-object spectrographs,fiber positioners located in the focal plane are being scaled down in size,and miniature hollow-cup Permanent Magnet motors are now being considered as a suitable replacement for Faulhaber Precistep stepper motors.However,the small electrical time constant of such coreless motors poses a challenge,as the problem of severe commutation torque ripple in a fiber positioner running a position loop has been tricky.To overcome this challenge,it is advised to increase the Pulse Width Modulation(PWM)frequency as much as possible to mitigate the effects of the current fluctuation.This must be done while ensuring adequate resolution of the PWM generator.By employing a voltage open-loop field-oriented control based on a modulation frequency of 1 MHz,the drive current only costs 25 m A under a 3.3 V power supply.The sine degree of phase current is immaculate,and the repeat positioning accuracy can reach 2μm.Moreover,it is possible to further shrink the bill of devices and the layout area of the Printed Circuit Board,especially in sizesensitive applications.This device has been developed under the new generation of The Large Sky Area MultiObject Fiber Spectroscopic Telescope. 展开更多
关键词 instrumentation:adaptive optics instrumentation:spectrographs proper motions reference systems
下载PDF
A Tilt-correction Adaptive Optical System for the Solar Telescope of Nanjing University 被引量:4
5
作者 Chang-HuiRao Wen-HanJiang +8 位作者 ChengFang NingLing Wei-ChaoZhou Ming-DeDing Xue-JunZhang Dong-HongChen meiLi Xiu-FaGao TianMi 《Chinese Journal of Astronomy and Astrophysics》 CSCD 北大核心 2003年第6期576-586,共11页
A tilt-correction adaptive optical system installed on the 430 mm Solar Telescope of Nanjing University has been put in operation. It consists of a tip-tilt mirror, a correlation tracker and an imaging CCD camera. An ... A tilt-correction adaptive optical system installed on the 430 mm Solar Telescope of Nanjing University has been put in operation. It consists of a tip-tilt mirror, a correlation tracker and an imaging CCD camera. An absolute difference algorithm is used for detecting image motion in the correlation tracker. The sampling frequency of the system is 419 Hz. We give a description of the system's configuration, an analysis of its performance and a report of our observational results. A residual jitter of 0.14 arcsec has been achieved. The error rejection bandwidth of the system can be adjusted in the range 5-28 Hz according to the beacon size and the strength of atmospheric turbulence. 展开更多
关键词 telescopes - atmospheric effects - instrumentation - adaptive optics - Sun: atmospheric motions
下载PDF
Tungsten ion source under double-pulse laser ablation system
6
作者 Ahmed Asaad I Khalil Ashraf I Hafez +1 位作者 Mahmoud E Elgohary Mohamed A Morsy 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第9期285-296,共12页
New tungsten ion source is produced by using single and double-pulse laser ablation system. Combined collinear Nd:YAG laser beams(266+1064 nm) are optimized to focus on the sample in air. Optimization of the exper... New tungsten ion source is produced by using single and double-pulse laser ablation system. Combined collinear Nd:YAG laser beams(266+1064 nm) are optimized to focus on the sample in air. Optimization of the experimental parameters is achieved to enhance the signal-to-noise ratio of the emission spectra. The velocity distribution of the emitted plasma cloud is carefully measured. The influences of the potential difference between the bias electrodes, laser wavelength and intensity on the current signal are also studied. The results show that the increase in the tungsten ion velocity under the double-pulse lasers causes the output current signal to increase by about three folds. The electron density and temperature are calculated by using the Stark-broadened line profile of tungsten line and Boltzmann plot method of the upper energy levels, respectively. The signal intensity dependence of the tungsten ion angular distribution is also analyzed. The results indicate that the double-pulse laser ablation configuration is more potent technique for producing more metal ion source deposition, thin film formation, and activated plasma-facing component material. 展开更多
关键词 tungsten ion beam double-pulse lasers ablation system laser ablation system optical instrumentation
下载PDF
New vacuum solar telescope and observations with high resolution 被引量:38
7
作者 Zhong Liu Jun Xu +18 位作者 Bo-Zhong Gu Sen Wang Jian-Qi You Long-Xiang Shen Ru-Wei Lu Zhen-Yu Jin Lin-Fei Chen Ke Lou Zhi Li Guang-Qian Liu Zhi Xu Chang-Hui Rao Qi-Qian Hu Ru-Feng Li Hao-Wen Fu Feng Wang Men-Xian Bao Ming-Chan Wu Bo-Rong Zhang 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2014年第6期705-718,共14页
The New Vacuum Solar Telescope (NVST) is a one meter vacuum solar telescope that aims to observe fine structures on the Sun. The main goals of NVST are high resolution imaging and spectral observations, including me... The New Vacuum Solar Telescope (NVST) is a one meter vacuum solar telescope that aims to observe fine structures on the Sun. The main goals of NVST are high resolution imaging and spectral observations, including measurements of the solar magnetic field. NVST is the primary ground-based facility used by the Chinese solar research community in this solar cycle. It is located by Fuxian Lake in southwest China, where the seeing is good enough to perform high resolution observations. We first introduce the general conditions at the Fuxian Solar Observatory and the primary science cases of NVST. Then, the basic structures of this telescope and instruments are described in detail. Finally, some typical high resolution data of the solar photosphere and chromosphere are also shown. 展开更多
关键词 telescopes -- instrumentation: adaptive optics -- instrumentation: spec-trographs -- techniques: high angular resolution -- Sun: magnetic fields
下载PDF
Portable adaptive optics for exoplanet imaging 被引量:5
8
作者 Yong-Tian Zhu Jiang-Pei Dou +3 位作者 Xi Zhang Gang Zhao Jing Guo Leopoldo Infante 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2021年第4期110-118,共9页
The portable adaptive optics(PAO)device is a low-cost and compact system,designed for 4-meter class telescopes that have no adaptive optics(AO)system,because of the physical space limitation at the Nasmyth or Cassegra... The portable adaptive optics(PAO)device is a low-cost and compact system,designed for 4-meter class telescopes that have no adaptive optics(AO)system,because of the physical space limitation at the Nasmyth or Cassegrain focus and the historically high cost of conventional AO.The initial scientific observations of the PAO are focused on the direct imaging of exoplanets and sub-stellar companions.This paper discusses the concept of PAO and the associated high-contrast imaging performance in our recent observational runs.PAO deliver a Strehl ratio better than 60%in H band under median seeing conditions of 1".Combined with our dedicated image rotation and subtraction(IRS)technique and the optimized IRS(O-IRS)algorithm,the averaged contrast ratio for a 5≤V_(mag)≤9 primary star is 1.3×10^(-5)and3.3×10^(-6)at angular distance of 0.36"with exposure time of 7 minutes and 2 hours,respectively.PAO has successfully revealed the known exoplanet ofκAnd b in our recent observation with the 3.5-meter ARC telescope at Apache Point Observatory.We have performed the associated astrometry and photometry analysis of the recoveredκAnd b planet,which gives a projected separation of 0.98"±0.05",a position angle of 51.1°±0.5°and a mass of 10.15_(-1.255)^(+2.19) MJup.These results demonstrate that PAO can be used for direct imaging of exoplanets with medium-sized telescopes. 展开更多
关键词 stars:imaging instrumentation:adaptive optics instrumentation:high angular resolution methods:observational techniques:image processing
下载PDF
Active Optics in LAMOST 被引量:3
9
作者 Ding-QiangSu Xiang-QunCui 《Chinese Journal of Astronomy and Astrophysics》 CSCD 北大核心 2004年第1期1-9,共9页
Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) is one of the major national projects under construction in China. Active optics is one of the most important technologies for new large telescopes. I... Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) is one of the major national projects under construction in China. Active optics is one of the most important technologies for new large telescopes. It is used for correcting telescope errors generated by gravitational and thermal changes. Here, however, we use this technology to realize the configuration of LAMOST,—a task that cannot be done in the traditional way. A comprehensive and intensive research on the active optics used in LAMOST is also reported, including an open-loop control method and an auxiliary closed-loop control method. Another important development is in our pre-calibration method of open-loop control, which is with some new features: simultaneous calculation of the forces and displacements of force actuators and displacement actuators; the profile of mirror can be arbitrary; the mirror surface shape is not expressed by a fitting polynomial, but is derived from the mirror surface shape formula which is highly accurate; a proof is given that the solution of the pre-calibration method is the same as the least squares solution. 展开更多
关键词 galaxies: distances and redshifts techniques: active optics telescopes instrumentation: adaptive optics
下载PDF
Simulation and fabrication of the atmospheric turbulence phase screen based on a fractal model 被引量:3
10
作者 Peng Jia Sijiong Zhang 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2012年第5期584-590,共7页
An atmospheric turbulence phase screen generated using a fractal method is introduced. It is etched onto fused silica and tested in the laboratory. The etched screen has relatively low cost, high resolution, and can b... An atmospheric turbulence phase screen generated using a fractal method is introduced. It is etched onto fused silica and tested in the laboratory. The etched screen has relatively low cost, high resolution, and can be used in the broad waveband under severe temperature conditions. Our results are shown to agree well with the theory. 展开更多
关键词 instrumentation adaptive optics -- turbulence atmospheric effects
下载PDF
Analysis of Detectors and Transmission Curve Correction of Mobile Rayleigh Doppler Wind Lidar 被引量:2
11
作者 唐磊 汪永涛 +8 位作者 舒志峰 董吉辉 王国成 徐文静 胡冬冬 陈廷娣 窦贤康 孙东松 CHA Hyunki 《Chinese Physics Letters》 SCIE CAS CSCD 2010年第11期99-102,共4页
A mobile molecular Doppler wind lidar (DWL) based on double-edge technique is presented for wind measurement at altitudes from 10 km to 40 km. A triple Fabry-Perot etalon is employed as a frequency discriminator to ... A mobile molecular Doppler wind lidar (DWL) based on double-edge technique is presented for wind measurement at altitudes from 10 km to 40 km. A triple Fabry-Perot etalon is employed as a frequency discriminator to determine the Doppler shift proportional to the wind velocity. The lidar operates at 355 nm with a 45-cm aperture telescope and a matching azimuth-over-elevation scanner that can provide full hemispherical pointing. In order to guarantee the wind accuracy, different forms of calibration function of detectors in different count rates response range would be especially valuable. The accuracy of wind velocity iteration is improved greatly because of application of the calibration function of linearity at the ultra low light intensity especially at altitudes from 10 km to 40 km. The calibration functions of nonlinearity make the transmission of edge channel 1 and edge channel 2 increase 38.9% and 27.7% at about 1 M count rates, respectively. The dynamic range of wind field measurement may also be extended because of consideration of the response function of detectors in their all possible operating range. 展开更多
关键词 instrumentation and measurement Optics quantum optics and lasers Environmental and Earth science
下载PDF
Stochastic parallel gradient descent based adaptive optics used for a high contrast imaging coronagraph 被引量:2
12
作者 Bing Dong De-Qing Ren Xi Zhang 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2011年第8期997-1002,共6页
An adaptive optics (AO) system based on a stochastic parallel gradient descent (SPGD) algorithm is proposed to reduce the speckle noises in the optical system of a stellar coronagraph in order to further improve t... An adaptive optics (AO) system based on a stochastic parallel gradient descent (SPGD) algorithm is proposed to reduce the speckle noises in the optical system of a stellar coronagraph in order to further improve the contrast. The principle of the SPGD algorithm is described briefly and a metric suitable for point source imaging optimization is given. The feasibility and good performance of the SPGD algorithm is demonstrated by an experimental system featured with a 140-actuator deformable mirror and a Hartrnann-Shark wavefront sensor. Then the SPGD based AO is applied to a liquid crystal array (LCA) based coronagraph to improve the contrast. The LCA can modulate the incoming light to generate a pupil apodization mask of any pattern. A circular stepped pattern is used in our preliminary experiment and the image contrast shows improvement from 10^-3 to 10^-4.5 at an angular distance of 2A/D after being corrected by SPGD based AO. 展开更多
关键词 instrumentation: adaptive optics -- methods: laboratory -- techniques: image processing CORONAGRAPH
下载PDF
First light for the sodium laser guide star adaptive optics system on the Lijiang 1.8 m telescope 被引量:2
13
作者 Kai Wei Min Li +23 位作者 Shan-Qiu Chen Yong Bo Feng Chen Jun-Wei Zuo Qi Bian Ji Yao Lu-Chun Zhou Lin Wei Dong-Hong Chen Yang Gao KaiJin Xiao-Lin Dai Han-Chu Fu Chang Xu Zhi-Chao Wang Xiang-Hui Xue Xue-Wu Chen Xian-Mei Qian Yu Zhou Hao Xian Qin-Jun Peng Chang-Hui Rao Zu-Yan Xu Yu-Dong Zhang 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2016年第12期41-45,共5页
A first generation sodium Laser Guide Star Adaptive Optics System (LGS-AOS) was developed and integrated into the Lijiang 1.8 m telescope in 2013. The LGS-AOS has three sub-systems: (1) a 20W long pulsed sodium l... A first generation sodium Laser Guide Star Adaptive Optics System (LGS-AOS) was developed and integrated into the Lijiang 1.8 m telescope in 2013. The LGS-AOS has three sub-systems: (1) a 20W long pulsed sodium laser, (2) a 300-millimeter-diameter laser launch telescope, and (3) a 37-element com- pact adaptive optics system. On 2014 January 25, we obtained high resolution images of an my 8.18 star, HIP 43963, during the first light of the LGS-AOS. In this paper, the sodium laser, the laser launch telescope, the compact adaptive optics system and the first light results will be presented. 展开更多
关键词 instrumentation: adaptive optics -- turbulence -- atmospheric effects
下载PDF
Improvement in the performance of solar adaptive optics 被引量:2
14
作者 Xiao-Fang Zhang Lian-Qi Wang 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2014年第4期471-484,共14页
Adaptive optics (AO), which provides diffraction limited imaging over a field-of-view (FOV), is a powerful technique for solar observation. In the tomographic approach, each wavefront sensor (WFS) is looking at ... Adaptive optics (AO), which provides diffraction limited imaging over a field-of-view (FOV), is a powerful technique for solar observation. In the tomographic approach, each wavefront sensor (WFS) is looking at a single reference that acts as a guide star. This allows a 3D reconstruction of the distorted wavefront to be made. The correction is applied by one or more deformable mirrors (DMs). This technique benefits from information about atmospheric turbulence at different layers, which can be used to reconstruct the wavefront extremely well. With the assistance of the MAOS software package, we consider the tomography errors and WFS aliasing errors, and focus on how the performance of a solar telescope (pointing toward zenith) is related to atmospheric anisoplanatism. We theoretically quantify the performance of the to- mographic solar AO system. The results indicate that the tomographic AO system can improve the average Strehl ratio of a solar telescope in a 10" - 80" diameter FOV by only employing one DM conjugated to the telescope pupil. Furthermore, we discuss the effects of DM conjugate altitude on the correction achievable by the AO system by selecting two atmospheric models that differ mainly in terms of atmospheric prop- erties at ground level, and present the optimum DM conjugate altitudes for different observation sites. 展开更多
关键词 instrumentation: adaptive optics -- atmospheric effects -- solar system
下载PDF
Numerical analysis of modal tomography for solar multi-conjugate adaptive optics 被引量:2
15
作者 Bing Dong De-Qing Ren Xi Zhang 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2012年第4期465-471,共7页
Multi-conjugate adaptive optics (MCAO) can considerably extend the cor- rected field of view with respect to classical adaptive optics, which will benefit solar observation in many aspects. In solar MCAO, the Sun st... Multi-conjugate adaptive optics (MCAO) can considerably extend the cor- rected field of view with respect to classical adaptive optics, which will benefit solar observation in many aspects. In solar MCAO, the Sun structure is utilized to provide multiple guide stars and a modal tomography approach is adopted to implement three- dimensional wavefront restorations. The principle of modal tomography is briefly re- viewed and a numerical simulation model is built with three equivalent turbulent lay- ers and a different number of guide stars. Our simulation results show that at least six guide stars are required for an accurate wavefront reconstruction in the case of three layers, and only three guide stars are needed in the two layer case. Finally, eigen- mode analysis results are given to reveal the singular modes that cannot be precisely retrieved in the tomography process. 展开更多
关键词 instrumentation: multi-conjugate adaptive optics -- tomography
下载PDF
A low-cost and high-performance technique for adaptive optics static wavefront correction 被引量:1
16
作者 De-Qing Ren Tian-Yu Zhang Gang Wang 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2021年第7期261-268,共8页
Non-Common Path Error(NCPE) is one of the factors that limit an Adaptive Optics(AO)system from delivering ultra-high performance. To correct the NCPE associated static aberration, we propose a simple but robust and hi... Non-Common Path Error(NCPE) is one of the factors that limit an Adaptive Optics(AO)system from delivering ultra-high performance. To correct the NCPE associated static aberration, we propose a simple but robust and high-performance pupil-plane based wavefront measurement and correction technique, which can copy a single-mode fiber generated perfect wavefront to the AO system via an iteration optimization process, and the NCPE can be effectively corrected by directly commanding the Deformable Mirror(DM) of the AO system. Compared with the previous focal-plane based approach that uses focal plane based Point Spread Function(PSF) for correction evaluation, the pupil-plane based approach can be reliably and rapidly converged to a global optimization result and provides better performance, in particular for an AO system with a large initial static wavefront error. This technique we proposed can be implemented in astronomical AO systems where extremely high performance is required. 展开更多
关键词 astronomical instrumentation:adaptive optics astronomical instrumentation:high angular resolution astronomical techniques:high angular resolution
下载PDF
NEAR-INFRARED IMAGING SENSOR WITH IMPROVED HANDLING AND DIRECT LOCALIZATION IN SIMULTANEOUS MAGNETIC RESONANCE IMAGING MEASUREMENTS
17
作者 SONJA SPICHTIG MARCO PICCIRELLI +1 位作者 ROBERT S.VORBURGER MARTIN WOLF 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2011年第2期191-198,共8页
We present a novel optical sensor to acquire simultaneously functional near-infrared imaging(fNIRI)and functional magnetic resonance imaging(fMRI)data with an improved handling and direct localization in the MRI compa... We present a novel optical sensor to acquire simultaneously functional near-infrared imaging(fNIRI)and functional magnetic resonance imaging(fMRI)data with an improved handling and direct localization in the MRI compared to available sensors.Quantitative phantom and interference measurements showed that both methods can be combined without reciprocal adverse effects.The direct localization of the optical sensor on MR images acquired with a T1-weighted echo sequence simplifies the co-registration of NIRI and MRI data.In addition,the optical sensor is simple to attach,which is crucial for measurements on vulnerable subjects.The fNIRI and T2^(*)-weighted fMRI data of a cerebral activation were simultaneously acquired proving the practicability of the setup. 展开更多
关键词 Medical optics instrumentation imaging systems functional monitoring and imaging
下载PDF
Numerical study of a 20W class QCW pulsed sodium guide star laser's performances at five sites in China
18
作者 Hong-Yang Li Lu Feng +6 位作者 Jun-Wei Zuo Qi Bian Bo-Tian Sun Sui-Jian Xue Zhi-Xia Shen Yang-Peng Li Yong Bo 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2021年第9期44-52,共9页
In the past few years,Chinese astronomical community is actively testing astronomical sites for several new optical/infrared ground-based telescopes.These site testing campaigns conducted were mainly focused on fundam... In the past few years,Chinese astronomical community is actively testing astronomical sites for several new optical/infrared ground-based telescopes.These site testing campaigns conducted were mainly focused on fundamental performances of the sites,such as cloud coverage,seeing,temperature,etc.With increasing interests in sodium laser guide star adaptive optics for these new telescopes in the Chinese astronomical community,it is interesting to investigate the performance of the laser guide star at these sites,especially considering that the sodium laser guide star’s on-sky performance is significantly influenced by sites’local performances,such as geomagnetic field,sodium layer dynamics,density of air molecule,etc.In this paper,we studied sodium laser guide star’s performance of a 20 W class Quasi Continuous Wave(QCW)pulsed laser developed by TIPC with numerical simulation for five selected sites in China. 展开更多
关键词 instrumentation:adaptive optics methods:numerical site testing
下载PDF
Characterizing microlensing planetary system OGLE-2014-BLG-0676Lb with adaptive optics imaging
19
作者 解小佳 东苏勃 +10 位作者 Yossi Shvartzvald Andrew Gould Andrzej Udalski Jean-Philippe Beaulieu Charles Beichman Laird Miller Close Calen B.Henderson Jared R.Males Jean-Baptiste Marquette Katie M.Morzinski Christopher R.Gelino 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2021年第12期357-364,共8页
We constrain the host-star flux of the microlensing planet OGLE-2014-BLG-0676 Lb using adaptive optics(AO)images taken by the Magellan and Keck telescopes.We measure the flux of the light blended with the microlensed ... We constrain the host-star flux of the microlensing planet OGLE-2014-BLG-0676 Lb using adaptive optics(AO)images taken by the Magellan and Keck telescopes.We measure the flux of the light blended with the microlensed source to be K=16.79±0.04 mag and J=17.76±0.03 mag.Assuming that the blend is the lens star,we find that the host is a 0.73_(-0.29)^(+0.14)M_(⊙)star at a distance of2.67_(-1.41)^(+0.77)kpc,where the relatively large uncertainty in angular Einstein radius measurement is the major source of uncertainty.With mass of M_(p)=3.68_(-1.44)^(+0.69)M_J,the planet is likely a"super Jupiter"at a projected separation of r_(⊥)=4.53_(-2.50)^(+1.49)AU,and a degenerate model yields a similar M_p=3.73_(-1.47)^(+0.73)M_(J)at a closer separation of r_(⊥)=2.56_(-1.41)^(+0.84)AU.Our estimates are consistent with the previous Bayesian analysis based on a Galactic model.OGLE-2014-BLG-0676 Lb belongs to a sample of planets discovered in a"secondgeneration"planetary microlensing survey and we attempt to systematically constrain host properties of this sample with high-resolution imaging to study the distribution of planets. 展开更多
关键词 gravitational lensing:micro instrumentation:adaptive optics instrumentation:high angular resolution (stars:)planetary systems
下载PDF
Simulation of a ground-layer adaptive optics system for the Kunlun Dark Universe Survey Telescope
20
作者 Peng Jia Sijiong Zhang 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2013年第7期875-884,共10页
Ground Layer Adaptive Optics (GLAO) is a recently developed technique extensively applied to ground-based telescopes, which mainly compensates for the wavefront errors induced by ground-layer turbulence to get an ap... Ground Layer Adaptive Optics (GLAO) is a recently developed technique extensively applied to ground-based telescopes, which mainly compensates for the wavefront errors induced by ground-layer turbulence to get an appropriate point spread function in a wide field of view. The compensation results mainly depend on the turbu-lence distribution. The atmospheric turbulence at Dome A in the Antarctic is mainly distributed below 15 meters, which is an ideal site for applications of GLAO. The GLAO system has been simulated for the Kunlun Dark Universe Survey Telescope, which will be set up at Dome A, and uses a rotating mirror to generate several laser guide stars and a wavefront sensor with a wide field of view to sequentially measure the wavefronts from different laser guide stars. The system is simulated on a computer and parameters of the system are given, which provide detailed information about the design of a practical GLAO system. 展开更多
关键词 instrumentation: adaptive optics - methods: numerical
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部