The performances of four optical particles counters, Aerosol Spectrometer (Grimm 1.108), Enviro Check (Grimm 1.107), DustMonit and ParticleScan, were evaluated in laboratory tests employing monodisperse aerosol partic...The performances of four optical particles counters, Aerosol Spectrometer (Grimm 1.108), Enviro Check (Grimm 1.107), DustMonit and ParticleScan, were evaluated in laboratory tests employing monodisperse aerosol particles. The study focused on how commercial instruments perform during routine measurements respect to OPC scientific understanding, because it is important for users of such instruments to be aware of their limitations. Measurements were performed using aerosol generated by a Monodisperse Aerosol Generator (MAGE), which produced carnauba wax particles of diameter (1.00 ± 0.08) μm and (1.40 ± 0.15) μm, and monodisperse Polystyrene Latex (PSL) aerosol with nominal diameter of 1.0mm. The results show comparable total particle number concentrations for all the counters, when the count of the first size channel (0.3 - 0.4 μm) for the 1.108 Grimm counter was left out. In the said channel the Grimm counter 1.108 always showed much higher particle counts than those inferred from the tested aerosols. The overcount was proved by the fact that the aerosol sampled in each test on a Nuclepore filter showed no particles in the 0.3 - 0.4 μm range when examined under Scanning Electronic Microscope (SEM). The presence of an artefact produced by the counter was assumed as a likely explanation. For all the counters, the Count Median Diameters (CMDs) of aerosol size distributions, were far below the expected value for the aerosol used. The nearest CMD values to the expected ones were shown by the Grimm 1.107 counter.展开更多
The Taklamakan Desert in China is one of the major source regions for Asian dust particles.All balloon-borne measurements in this report were carried out in Dunhuang,in the Taklamakan Desert,during calm weather condit...The Taklamakan Desert in China is one of the major source regions for Asian dust particles.All balloon-borne measurements in this report were carried out in Dunhuang,in the Taklamakan Desert,during calm weather conditions.The aerosol number concentration,size distribution,mass concentration,and horizontal mass flux due to westerly wind were investigated.The measurements were performed on 17 August 2001,17 October 2001,11 January 2002,and 30 April 2002.Five channels(0.3,0.5,0.8,1.2,and 3.6μm in diameter)were used in the Optical Particle Counter for particle measurements.The aerosol number concentration in the winter season(11 January 2002)at 3–5 km was very high.Variation of free-tropospheric aerosols on 30 April 2002 was noticeable.A super-micron range was noticeable in the size distribution of all the measurements.Many variations in temperature and aerosol concentration were found at these inversion points.High values of estimated mass concentration of aerosols were frequently observed in the atmosphere near the ground(i.e.,1–2 km);and interestingly,relatively high concentrations were frequently detected above 2 km from the surface.Wind patterns observed using ERA-Interim data at 500 and 850 hPa showed that westerly winds dominated in the Taklamakan Desert during the observation period.The average horizontal mass flux of background Asian dust due to westerly wind was observed to fall within the range of 58.5–1219 tons km?2 d?1.Vertical profiles of aerosol number concentrations showed that significant transport of aerosols dominated in the westerly region(i.e.,4–7 km).展开更多
A model for measuring aerosol mass concentration by an optical particle counter is presented using the conception of the average mass. In this model, to understand the meaning of the pulse height distribution of parti...A model for measuring aerosol mass concentration by an optical particle counter is presented using the conception of the average mass. In this model, to understand the meaning of the pulse height distribution of particles which is used to inverse mass concentration, the relationship among intensity distribution in the optical sensing volume, particle shape, and the pulse height distribution is discussed. To solve the instability of the equivalent factor, a novel two-step calibration method is proposed. The experimental results demonstrate that mass concentrations calculated by the model are in good agreement with those measured by a norm-referenced instrument. For samples of soot and air, the slopes of fitting lines of data points are 0.9582 and 0.9220, and the correlation coefficients are 0.9991 and 0.9965, respectively.展开更多
This study presents the development of a medium flow, multiple slit based PM2.5 (particle aerodynamic diameter 〈2.5 μm) inertial impactor. Its performance was compared with that of a light scattering based optical...This study presents the development of a medium flow, multiple slit based PM2.5 (particle aerodynamic diameter 〈2.5 μm) inertial impactor. Its performance was compared with that of a light scattering based optical particle sizer in a field study and in controlled lab based experiments using polydisperse dolomite powder as test aerosol. The impactor's optimum nozzle configuration had a cutoff size of 2.51 μm (aero- dynamic diameter) at an operating flow rate of 215 L/rain with a pressure drop of 0.35 kPa across the impactor stage. Because the apparent particle density of an ambient aerosol depends on the physical properties and the chemical composition of the particles, the PM2.5 mass concentration was measured with an optical particle sizer and an inertial impactor over a weekday and a weekend day in a field study during which the effective particle shape factor and density were in tandem modified in order to com- pare the results from the two sampling techniques. The correlation of the two instrument results tended towards 1:1 with increasing values of shape factor (irregular shaped) and effective particle density. This observation was supported through chemical investigations of the collected mass, which showed a higher percentage contribution from elements which are mostly of crustal nature (namely, Ca, Fe, and Mg).展开更多
文摘The performances of four optical particles counters, Aerosol Spectrometer (Grimm 1.108), Enviro Check (Grimm 1.107), DustMonit and ParticleScan, were evaluated in laboratory tests employing monodisperse aerosol particles. The study focused on how commercial instruments perform during routine measurements respect to OPC scientific understanding, because it is important for users of such instruments to be aware of their limitations. Measurements were performed using aerosol generated by a Monodisperse Aerosol Generator (MAGE), which produced carnauba wax particles of diameter (1.00 ± 0.08) μm and (1.40 ± 0.15) μm, and monodisperse Polystyrene Latex (PSL) aerosol with nominal diameter of 1.0mm. The results show comparable total particle number concentrations for all the counters, when the count of the first size channel (0.3 - 0.4 μm) for the 1.108 Grimm counter was left out. In the said channel the Grimm counter 1.108 always showed much higher particle counts than those inferred from the tested aerosols. The overcount was proved by the fact that the aerosol sampled in each test on a Nuclepore filter showed no particles in the 0.3 - 0.4 μm range when examined under Scanning Electronic Microscope (SEM). The presence of an artefact produced by the counter was assumed as a likely explanation. For all the counters, the Count Median Diameters (CMDs) of aerosol size distributions, were far below the expected value for the aerosol used. The nearest CMD values to the expected ones were shown by the Grimm 1.107 counter.
基金supported by the National Natural Science Foundations of China [grant numbers 41590871 and 41475136]the International Science&Technology Cooperation Program of China [grant number 2013DFG22820]
文摘The Taklamakan Desert in China is one of the major source regions for Asian dust particles.All balloon-borne measurements in this report were carried out in Dunhuang,in the Taklamakan Desert,during calm weather conditions.The aerosol number concentration,size distribution,mass concentration,and horizontal mass flux due to westerly wind were investigated.The measurements were performed on 17 August 2001,17 October 2001,11 January 2002,and 30 April 2002.Five channels(0.3,0.5,0.8,1.2,and 3.6μm in diameter)were used in the Optical Particle Counter for particle measurements.The aerosol number concentration in the winter season(11 January 2002)at 3–5 km was very high.Variation of free-tropospheric aerosols on 30 April 2002 was noticeable.A super-micron range was noticeable in the size distribution of all the measurements.Many variations in temperature and aerosol concentration were found at these inversion points.High values of estimated mass concentration of aerosols were frequently observed in the atmosphere near the ground(i.e.,1–2 km);and interestingly,relatively high concentrations were frequently detected above 2 km from the surface.Wind patterns observed using ERA-Interim data at 500 and 850 hPa showed that westerly winds dominated in the Taklamakan Desert during the observation period.The average horizontal mass flux of background Asian dust due to westerly wind was observed to fall within the range of 58.5–1219 tons km?2 d?1.Vertical profiles of aerosol number concentrations showed that significant transport of aerosols dominated in the westerly region(i.e.,4–7 km).
基金the Doctor Creation Foundation of Nanjing University of Science and Technology
文摘A model for measuring aerosol mass concentration by an optical particle counter is presented using the conception of the average mass. In this model, to understand the meaning of the pulse height distribution of particles which is used to inverse mass concentration, the relationship among intensity distribution in the optical sensing volume, particle shape, and the pulse height distribution is discussed. To solve the instability of the equivalent factor, a novel two-step calibration method is proposed. The experimental results demonstrate that mass concentrations calculated by the model are in good agreement with those measured by a norm-referenced instrument. For samples of soot and air, the slopes of fitting lines of data points are 0.9582 and 0.9220, and the correlation coefficients are 0.9991 and 0.9965, respectively.
文摘This study presents the development of a medium flow, multiple slit based PM2.5 (particle aerodynamic diameter 〈2.5 μm) inertial impactor. Its performance was compared with that of a light scattering based optical particle sizer in a field study and in controlled lab based experiments using polydisperse dolomite powder as test aerosol. The impactor's optimum nozzle configuration had a cutoff size of 2.51 μm (aero- dynamic diameter) at an operating flow rate of 215 L/rain with a pressure drop of 0.35 kPa across the impactor stage. Because the apparent particle density of an ambient aerosol depends on the physical properties and the chemical composition of the particles, the PM2.5 mass concentration was measured with an optical particle sizer and an inertial impactor over a weekday and a weekend day in a field study during which the effective particle shape factor and density were in tandem modified in order to com- pare the results from the two sampling techniques. The correlation of the two instrument results tended towards 1:1 with increasing values of shape factor (irregular shaped) and effective particle density. This observation was supported through chemical investigations of the collected mass, which showed a higher percentage contribution from elements which are mostly of crustal nature (namely, Ca, Fe, and Mg).