A method is presented to improve the laser frequency stabilization for the optical pumping cesium clock. By comparing the laser frequency stabilization of different schemes, we verify that the light angle is an import...A method is presented to improve the laser frequency stabilization for the optical pumping cesium clock. By comparing the laser frequency stabilization of different schemes, we verify that the light angle is an important factor that limits the long-term frequency stability. We minimize the drift of the light angle by using a fiber- coupled output, and lock the frequency of a distributed-feedback diode laser to the fluorescence spectrum of the atomic beam. The measured frequency stability is about 3.5 ×10^-11 at i s and reaches 1.5 × 10^-12 at 2000s. The Allan variance keeps going down for up to thousands of seconds, indicating that the medium- and long-term stability of the laser frequency is significantly improved and perfectly fulfills the requirement for the optical pumping cesium clock.展开更多
Optical stability of chiral 2-methylbutyric acid in gas phase has been detected with Quadrupole-Quistor-Quadrupole tandem mass spectrometer in combination with deuteration. The results show that these compounds are op...Optical stability of chiral 2-methylbutyric acid in gas phase has been detected with Quadrupole-Quistor-Quadrupole tandem mass spectrometer in combination with deuteration. The results show that these compounds are optically unstable in the process of self chemical ionization.展开更多
The laser frequency could be linked to an radio frequency through an external cavity by the combination of Pound-Drever-Hall and Devoe-Brewer locking techniques.A stable and tunable optical frequency at wavelength of ...The laser frequency could be linked to an radio frequency through an external cavity by the combination of Pound-Drever-Hall and Devoe-Brewer locking techniques.A stable and tunable optical frequency at wavelength of 1.5μm obtained by a cavity with high finesse of 96000 and a fiber laser has been demonstrated,calibrated by a commercial optical frequency comb.The locking performances have been analyzed by in-loop and out-loop noises,indicating that the absolute frequency instability could be down to 50 kHz over 1 s and keep to less than 110 kHz over 2.5 h.Then,the application of this stabilized laser to the direct absorption spectroscopy has been performed.With the help of balanced detection,the detection sensitivity,in terms of optical density,can reach to 9.4×10^(-6).展开更多
Fluorinated amorphous carbon films were deposited using microwave electron cyclotron resonance chemical vapor deposition (ECR-CVD) reactor with CF4 and C8H6 as source gas and were annealed in nitrogen ambience for the...Fluorinated amorphous carbon films were deposited using microwave electron cyclotron resonance chemical vapor deposition (ECR-CVD) reactor with CF4 and C8H6 as source gas and were annealed in nitrogen ambience for the investigating of their thermal stability .The relative concentration of C=C bond and optical bandgap were obtained by Fourier Transform Infrared (FTIR) spectroscopy and Ultraviolet-Visible (UV-VIS ) spectrum, respectively. It has been demonstrated that there is a close relationship between relative concentration of C=C bond and optical bandgap, and the films deposited at a higher microwave power have a lower optical bandgap and a better thermal stability.展开更多
A new fi ber optic sensor based on the oxidation of 2,4-dichlorophenol(DCP) catalyzed by iron(II) phthalocyanine(Fe(II)Pc) was developed for the determination of DCP. The optical oxygen sensing fi lm containin...A new fi ber optic sensor based on the oxidation of 2,4-dichlorophenol(DCP) catalyzed by iron(II) phthalocyanine(Fe(II)Pc) was developed for the determination of DCP. The optical oxygen sensing fi lm containing fl uorescence indicator Ru(bpy)3Cl2 was used to detect the consumption of oxygen in solution. Moreover, a lock-in amplifier was used to determine the lifetime of the sensor head by detecting its phase delay change. The results reveal that the sensor has a linear detection range of 1.0×10^-6- 9.0×10^-5 mol/L and a response time of 5 min. The sensor also has high selectivity, good repeatability and stability. It can be used effectively to determine DCP concentration in real samples.展开更多
Axonal projections are specialized neuronal compartments and the longest parts of neurons.Axonal degeneration is a common pathological feature in many neurodegenerative disorders,such as Parkinson’s disease,amyotroph...Axonal projections are specialized neuronal compartments and the longest parts of neurons.Axonal degeneration is a common pathological feature in many neurodegenerative disorders,such as Parkinson’s disease,amyotrophic lateral sclerosis,glaucoma,as well as in traumatic lesions of the central nervous system(CNS),such as spinal cord injury.展开更多
A new silica antireflective coating with improved hydrophobicity and optical stability in a vacuum is obtained by a two-step route. Firstly, silica sols are prepared with a sol-gel process, in which tetraethyl orthosi...A new silica antireflective coating with improved hydrophobicity and optical stability in a vacuum is obtained by a two-step route. Firstly, silica sols are prepared with a sol-gel process, in which tetraethyl orthosilicate is utilized as a precursor. And by introduction of fluorine containing glycol into the sols, the porosity of silica particles and surface polarity of the coatings are decreased. Afterward, coatings are constructed with low surface roughness by modification of PMBA-PMMA. The coatings retain transmission of up to 99.6%, and laser damage threshold of about 50 J/cm^2 at a wavelenth of 532 nm (1-on-1. 10 ns)展开更多
The stabilizing process of glass particle in water by optical trap using the pulsed counter-propagating Gaussian beams is investigated. The influence of the optical power and the particle dimension on the rate and tim...The stabilizing process of glass particle in water by optical trap using the pulsed counter-propagating Gaussian beams is investigated. The influence of the optical power and the particle dimension on the rate and time of the stabilizing process is simulated and discussed.展开更多
基金Supported by the National Fundamental Research Program of China under Grant No 2011CB921501the National Natural Science Foundation of China under Grant Nos 91336103,10934010 and 61078026
文摘A method is presented to improve the laser frequency stabilization for the optical pumping cesium clock. By comparing the laser frequency stabilization of different schemes, we verify that the light angle is an important factor that limits the long-term frequency stability. We minimize the drift of the light angle by using a fiber- coupled output, and lock the frequency of a distributed-feedback diode laser to the fluorescence spectrum of the atomic beam. The measured frequency stability is about 3.5 ×10^-11 at i s and reaches 1.5 × 10^-12 at 2000s. The Allan variance keeps going down for up to thousands of seconds, indicating that the medium- and long-term stability of the laser frequency is significantly improved and perfectly fulfills the requirement for the optical pumping cesium clock.
文摘Optical stability of chiral 2-methylbutyric acid in gas phase has been detected with Quadrupole-Quistor-Quadrupole tandem mass spectrometer in combination with deuteration. The results show that these compounds are optically unstable in the process of self chemical ionization.
基金supported by the National Key R&D Program of China(Grant No.2017YFA0304203)the National Natural Science Foundation of China(Grant Nos.61875107,61905136,61905134,62175139)+1 种基金Scientific and Technological Innovation Programs of Higher Education Institutions in Shanxi,China(Grant No.2019L0062)Opening Foundation of Key Laboratory of Laser&Infrared System(Shandong University)。
文摘The laser frequency could be linked to an radio frequency through an external cavity by the combination of Pound-Drever-Hall and Devoe-Brewer locking techniques.A stable and tunable optical frequency at wavelength of 1.5μm obtained by a cavity with high finesse of 96000 and a fiber laser has been demonstrated,calibrated by a commercial optical frequency comb.The locking performances have been analyzed by in-loop and out-loop noises,indicating that the absolute frequency instability could be down to 50 kHz over 1 s and keep to less than 110 kHz over 2.5 h.Then,the application of this stabilized laser to the direct absorption spectroscopy has been performed.With the help of balanced detection,the detection sensitivity,in terms of optical density,can reach to 9.4×10^(-6).
文摘Fluorinated amorphous carbon films were deposited using microwave electron cyclotron resonance chemical vapor deposition (ECR-CVD) reactor with CF4 and C8H6 as source gas and were annealed in nitrogen ambience for the investigating of their thermal stability .The relative concentration of C=C bond and optical bandgap were obtained by Fourier Transform Infrared (FTIR) spectroscopy and Ultraviolet-Visible (UV-VIS ) spectrum, respectively. It has been demonstrated that there is a close relationship between relative concentration of C=C bond and optical bandgap, and the films deposited at a higher microwave power have a lower optical bandgap and a better thermal stability.
基金Funded by the National Natural Science Foundation of China(Nos.61377092 and 51303115)
文摘A new fi ber optic sensor based on the oxidation of 2,4-dichlorophenol(DCP) catalyzed by iron(II) phthalocyanine(Fe(II)Pc) was developed for the determination of DCP. The optical oxygen sensing fi lm containing fl uorescence indicator Ru(bpy)3Cl2 was used to detect the consumption of oxygen in solution. Moreover, a lock-in amplifier was used to determine the lifetime of the sensor head by detecting its phase delay change. The results reveal that the sensor has a linear detection range of 1.0×10^-6- 9.0×10^-5 mol/L and a response time of 5 min. The sensor also has high selectivity, good repeatability and stability. It can be used effectively to determine DCP concentration in real samples.
基金funded by a fellow of the Coordination for the Improvement of Higher Education Personnel(CAPES),Brazil to VTRa funding from the DFG-Center for Nanoscale Microscopy and Molecular Physiology of the Brain(CNMPB) to PL
文摘Axonal projections are specialized neuronal compartments and the longest parts of neurons.Axonal degeneration is a common pathological feature in many neurodegenerative disorders,such as Parkinson’s disease,amyotrophic lateral sclerosis,glaucoma,as well as in traumatic lesions of the central nervous system(CNS),such as spinal cord injury.
基金supported by the National Major Project of Science and Technology under Grant No.2013ZX04006011-101
文摘A new silica antireflective coating with improved hydrophobicity and optical stability in a vacuum is obtained by a two-step route. Firstly, silica sols are prepared with a sol-gel process, in which tetraethyl orthosilicate is utilized as a precursor. And by introduction of fluorine containing glycol into the sols, the porosity of silica particles and surface polarity of the coatings are decreased. Afterward, coatings are constructed with low surface roughness by modification of PMBA-PMMA. The coatings retain transmission of up to 99.6%, and laser damage threshold of about 50 J/cm^2 at a wavelenth of 532 nm (1-on-1. 10 ns)
文摘The stabilizing process of glass particle in water by optical trap using the pulsed counter-propagating Gaussian beams is investigated. The influence of the optical power and the particle dimension on the rate and time of the stabilizing process is simulated and discussed.