期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Optimal Configuration Method for the Installed Capacity of the Solar-Thermal Power Stations
1
作者 Yan Wang Zhicheng Ma +3 位作者 Jinping Zhang Qiang Zhou Ruiping Zhang Haiying Dong 《Energy Engineering》 EI 2023年第4期949-963,共15页
Because of the randomness of wind power and photovoltaic(PV)output of new energy bases,the problem of peak regulation capability and voltage stability of ultra-high voltage direct current(UHVDC)transmission lines,we p... Because of the randomness of wind power and photovoltaic(PV)output of new energy bases,the problem of peak regulation capability and voltage stability of ultra-high voltage direct current(UHVDC)transmission lines,we proposed an optimum allocation method of installed capacity of the solar-thermal power station based on chance constrained programming in this work.Firstly,we established the uncertainty model of wind power and PV based on the chance constrained planning theory.Then we used the K-medoids clusteringmethod to cluster the scenarios considering the actual operation scenarios throughout the year.Secondly,we established the optimal configuration model based on the objective function of the strongest transient voltage stability and the lowest overall cost of operation.Finally,by quantitative analysis of actual wind power and photovoltaic new energy base,this work verified the feasibility of the proposed method.As a result of the simulations,we found that using the optimal configuration method of solar-thermal power stations could ensure an accurate allocation of installed capacity.When the installed capacity of the solar-thermal power station is 1×106 kW,the transient voltage recovery index(TVRI)is 0.359,which has a strong voltage support capacity for the system.Based on the results of this work,the optimal configuration of the installed capacity of the solar-thermal power plant can improve peak shaving performance,transient voltage support capability,and new energy consumption while satisfying the Direct Current(DC)outgoing transmission premise. 展开更多
关键词 Solar-thermal power station optimal configuration of installed capacity new energy base multi-objective optimization chance constrained planning theory
下载PDF
Optimal Configuration of Dispersion Compensation Modules with Installation Limits
2
作者 Malin Premaratne Prashan Premaratne 《光学学报》 EI CAS CSCD 北大核心 2003年第S1期577-578,共2页
Selecting a cost optimum subset of discrete-value dispersion compensation modules (DV-DCMs) subject to maximum module count from an available set of DV-DCMs is a NP-hard problem. We derive a novel dynamic programming ... Selecting a cost optimum subset of discrete-value dispersion compensation modules (DV-DCMs) subject to maximum module count from an available set of DV-DCMs is a NP-hard problem. We derive a novel dynamic programming algorithm with pseudo-polynomial time bound and show that DV-DCM cost re-scaling can improve the running time. 展开更多
关键词 of on in BE for optimal Configuration of Dispersion Compensation Modules with installation Limits that DCM with
原文传递
Optimization of magnetic anomaly detection with single-axis sensor for pig locating in low latitude areas
3
作者 Wei Xu Zhiyong Guo +2 位作者 Zhongxiang Liu Peng Zhang Yanxi Zhou 《Petroleum》 CSCD 2019年第4期417-423,共7页
When a pig mounted with permanent magnets gets stuck in the pipeline,it can be located by detecting the magnetic anomalies on the ground using a single-axis magnetic sensor.In order to collect the magnetic anomaly eff... When a pig mounted with permanent magnets gets stuck in the pipeline,it can be located by detecting the magnetic anomalies on the ground using a single-axis magnetic sensor.In order to collect the magnetic anomaly efficiently through single-axis magnetic sensor,a geometric detection model and calculation method for singleaxis magnetic anomaly detection is established in this paper.The distribution of magnetic inclination and declination of the measuring points is obtained.The results indicate that the magnetic inclination of all measuring points vary within a small range of 2°,and this value is highly dependent on the magnetic sensor which is configured aboveground around the geomagnetic inclination.However,the magnetic declination at different points of detection surface is subject to the geomagnetic components and the Y-axis component of the magnetic field of magnets.The magnetic declinations distribute irregularly and vary in a wide range.Therefore,to achieve a high-efficiency detection with the single-axis sensor,the sensor shall be placed in such a manner that the magnetic inclination thereof coincides with the geomagnetic inclination.The magnetic declination of the sensor can be calculated using s,the superposed Y-axis component induced by the permanent magnets,and the corresponding formula given in this paper.The article demonstrates the feasibility of locating a blocked pig in the pipeline based on the single-axis magnetic anomaly detection.It will have a practical significance in guiding the engineering detection. 展开更多
关键词 Pig blockage Pig locating Single-axis magnetic anomaly Magnetic anomaly detection Optimized installation of sensor
原文传递
Warwick International Hotels installs Optims Revenue Management System
4
《饭店现代化》 2004年第7期45-45,共1页
Optims S.A. (Evry, France), the leading global provider of Revenue Management Systems (RMS) and IT enabling solutions dedicated to the hospitality, tourism and transport industries is pleased to announce the implement... Optims S.A. (Evry, France), the leading global provider of Revenue Management Systems (RMS) and IT enabling solutions dedicated to the hospitality, tourism and transport industries is pleased to announce the implementation of an Optims.Hotel Revenue Management System in the Royal Windsor Hotel, Brussels, a Warwick International Hotel and a member of Leading Hotels of the World. 展开更多
关键词 Warwick International Hotels installs Optims Revenue Management System
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部