期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
GOCE kinematic orbit adjustment for EGM validation and accelerometer calibration
1
作者 徐天河 孙张振 +2 位作者 江楠 陈康康 李敏 《Journal of Central South University》 SCIE EI CAS 2014年第6期2397-2403,共7页
The main principle and mathematical model of GOCE kinematic orbit adjustment for Earth gravity field model (EGM) validation and accelerometer calibration are presented. Based on 60 days GOCE kinematic orbits with 1-... The main principle and mathematical model of GOCE kinematic orbit adjustment for Earth gravity field model (EGM) validation and accelerometer calibration are presented. Based on 60 days GOCE kinematic orbits with 1-2 cm accuracy and accelerometer data from 2009-11-02 to 2009-12-31, the RMS-of-fit (ROF) of them using EGM2008, EIGEN-SC, ITG- GRACE2010S and GOCO01S up to 120, 150 and 180 degree and order (d/o) are evaluated and compared. The scale factors and biases of GOCE accelerometer data are calibrated and the energy balance method (EBM) is performed to test the accuracy of accelerometer calibration. The results show that GOCE orbits are also sensitive to EGM from 120 to 150 d/o. The ROFs of EGMs with 150 and 180 d/o are obviously better than those of EGMs with 120 d/o. The ROFs of GOCO01S and ITG-GRACE2010S are almost the same up to 120 and 150 d/o, which are about 3.3 cm and 1.8 cm, respectively. They are far better than those of EGM2008 and EIGEN-SC with the same d/o. The ROF of GOCO01S with 180 d/o is about 1.6 em, which is the best one among those EGMs. The accelerometer calibration accuracies (ACAs) of ITG-GRACE2010S and GOCO01S are obviously higher that those of EGM2008 and EIGEN-SC. The ACA of GOCO01S with 180 d/o is far higher than that of EGMs with 120 d/o, and a little higher than that of ITG-GRACE2010S with 150 d/o. I t is suggested that the newest released EGM such as GOCO01S or GOCO02S till at least 150 d/o should be chosen in GOCE precise orbit determination (POD) and accelerometer calibration. 展开更多
关键词 GOCE orbit adjustment Earth gravity field model kinematic orbit accelerometer calibration
下载PDF
Efficiency enhancement for the orbital angular momentum photon quantum interface via single photon frequency upconversion
2
作者 吴文杰 马建辉 +4 位作者 潘海峰 武愕 陈怀熹 K.Choge Dismas 梁万国 《Optoelectronics Letters》 EI 2017年第2期156-160,共5页
As the application of orbital angular momentum(OAM) of photon quantum in quantum communication, the OAM photon quantum interface for the transmission wavelength from the telecom communication quantum information stora... As the application of orbital angular momentum(OAM) of photon quantum in quantum communication, the OAM photon quantum interface for the transmission wavelength from the telecom communication quantum information storage in visible regime is required. Here we demonstrate the efficiency enhancement for the OAM photon quantum interface based on the frequency upconversion from telecom wavelength to visible regime by sum-frequency generation. The infrared photons at 1 558 nm carrying different OAM values could be converted to the visible regime at 622.2 nm with the optimal efficiency via adjusting the pump beam waist radius and intensity. 展开更多
关键词 momentum telecom photon orbital angular visible carrying radius adjusting converted
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部