Firstly, physical and chemical properties of dust removed from BOF gas are analyzed, and then the cold banding technology of dust removed from BOF gas and its application are introduced. Tests have proved that using c...Firstly, physical and chemical properties of dust removed from BOF gas are analyzed, and then the cold banding technology of dust removed from BOF gas and its application are introduced. Tests have proved that using cooled agglomerated pellets made of the dust removed from BOF gas and small amounts of modified starch as a coolant and slagging agent in steel production can bring about considerable economic, social and environmental benefits.展开更多
Objective:To explore the implementation of gastrointestinal endoscopy technology and endoscopic narrow-band imaging(NBI)in the early screening of gastric cancer and to observe and study their application effects.Metho...Objective:To explore the implementation of gastrointestinal endoscopy technology and endoscopic narrow-band imaging(NBI)in the early screening of gastric cancer and to observe and study their application effects.Methods:During the period from March 2023 to August 2023,312 patients who received gastroscopy in the Kunming Guandu District People’s Hospital were selected,and they underwent both conventional gastroscopy and endoscopic NBI,with clinicopathological tissue biopsy serving as the gold standard.The application value for early screening of gastric cancer was observed and analyzed.Results:The scoring data showed that the clarity of gastric mucosal glandular tube structure,microvascular structure clarity,and lesion contour scoring data of conventional gastroscopy were lower than those of the NBI technology(P<0.05).The screening rate of pathological biopsy in 312 patients was 18.59%(58 cases).Conventional gastroscopy showed a screening rate of 11.53%(36 cases),while NBI technology examined a screening rate of 17.63%(55 cases),and the two-by-two comparison of the screening rate data of the three groups was not statistically significant(P>0.05).The sensitivity,specificity,accuracy,positive predictive value,and negative predictive value of conventional gastroscopy appeared to be lower than those of NBI technology(P<0.05).Conclusion:In the early screening of gastric cancer,endoscopic NBI technology can be applied to patients.Compared with conventional gastroscopy,it provides a clearer visualization of the structure of the gastric mucosal glandular structure and microvascular structure,with a certain screening rate.Additionally,its sensitivity,specificity,accuracy,positive predictive value,and negative predictive value are higher,demonstrating outstanding effectiveness.展开更多
A specially designed experiment is performed for investigating gate-induced drain leakage (GIDL) current in 90nm CMOS technology using lightly-doped drain (LDD) NMOSFET. This paper shows that the drain bias VD has...A specially designed experiment is performed for investigating gate-induced drain leakage (GIDL) current in 90nm CMOS technology using lightly-doped drain (LDD) NMOSFET. This paper shows that the drain bias VD has a strong effect on GIDL current as compared with the gate bias VG at the same drain-gate voltage VDG. It is found that the difference between ID in the off-state ID - VG characteristics and the corresponding one in the off-state ID - VD characteristics, which is defined as IDIFF, versus VDG shows a peak. The difference between the influences of VD and VG on GIDL current is shown quantitatively by IDIFF, especially in 90nm scale. The difference is due to different hole tunnellings, Furthermore, the maximum IDIFF(IDIFF,MAX) varies linearly with VDG in logarithmic coordiuates and also VDG at IDIFF,MAX with VF which is the characteristic voltage of IDIFF, The relations are studied and some related expressions are given.展开更多
This research analyzes and implements an innovative and tiny ultrawideband(UWB)antenna with band-notched features for body-centric communication.The shape of the designed antenna looks like a‘swan’with a slotted pat...This research analyzes and implements an innovative and tiny ultrawideband(UWB)antenna with band-notched features for body-centric communication.The shape of the designed antenna looks like a‘swan’with a slotted patch.Computer Simulation Technology(CST)is used to assess and investigate the performance of this antenna.With a band notch,this antenna can prevent interference from Wireless Local Area Network(WLAN)(5.15–5.825 GHz)and Worldwide Interoperability for Microwave Access(WiMAX)(5.25–5.85 GHz)systems.At first,the performance parameters like return loss response,gain,radiation patterns,and radiation efficiency of this UWB antenna are evaluated.After that,the human body effects on the antenna performance of the antenna are also examined to place the antenna at various distances away from 3-layers of phantom body model at different frequencies.All the on-body performance parameter results are compared and analyzed with free space performance parameter results.Lastly,by changing patch slot length and ground plane length,parametric studies were done for performance comparison.According to this research,it is noticed that the antenna is tiny and new.It shows good performance in body case as well.Hence,the antenna is very suitable for healthcare applications.展开更多
文摘Firstly, physical and chemical properties of dust removed from BOF gas are analyzed, and then the cold banding technology of dust removed from BOF gas and its application are introduced. Tests have proved that using cooled agglomerated pellets made of the dust removed from BOF gas and small amounts of modified starch as a coolant and slagging agent in steel production can bring about considerable economic, social and environmental benefits.
文摘Objective:To explore the implementation of gastrointestinal endoscopy technology and endoscopic narrow-band imaging(NBI)in the early screening of gastric cancer and to observe and study their application effects.Methods:During the period from March 2023 to August 2023,312 patients who received gastroscopy in the Kunming Guandu District People’s Hospital were selected,and they underwent both conventional gastroscopy and endoscopic NBI,with clinicopathological tissue biopsy serving as the gold standard.The application value for early screening of gastric cancer was observed and analyzed.Results:The scoring data showed that the clarity of gastric mucosal glandular tube structure,microvascular structure clarity,and lesion contour scoring data of conventional gastroscopy were lower than those of the NBI technology(P<0.05).The screening rate of pathological biopsy in 312 patients was 18.59%(58 cases).Conventional gastroscopy showed a screening rate of 11.53%(36 cases),while NBI technology examined a screening rate of 17.63%(55 cases),and the two-by-two comparison of the screening rate data of the three groups was not statistically significant(P>0.05).The sensitivity,specificity,accuracy,positive predictive value,and negative predictive value of conventional gastroscopy appeared to be lower than those of NBI technology(P<0.05).Conclusion:In the early screening of gastric cancer,endoscopic NBI technology can be applied to patients.Compared with conventional gastroscopy,it provides a clearer visualization of the structure of the gastric mucosal glandular structure and microvascular structure,with a certain screening rate.Additionally,its sensitivity,specificity,accuracy,positive predictive value,and negative predictive value are higher,demonstrating outstanding effectiveness.
基金Project supported by the National High Technology Research and Development Program of China (Grant No 2003AA1Z1630) and the National Natural Science Foundation of China (Grant No 60376024).
文摘A specially designed experiment is performed for investigating gate-induced drain leakage (GIDL) current in 90nm CMOS technology using lightly-doped drain (LDD) NMOSFET. This paper shows that the drain bias VD has a strong effect on GIDL current as compared with the gate bias VG at the same drain-gate voltage VDG. It is found that the difference between ID in the off-state ID - VG characteristics and the corresponding one in the off-state ID - VD characteristics, which is defined as IDIFF, versus VDG shows a peak. The difference between the influences of VD and VG on GIDL current is shown quantitatively by IDIFF, especially in 90nm scale. The difference is due to different hole tunnellings, Furthermore, the maximum IDIFF(IDIFF,MAX) varies linearly with VDG in logarithmic coordiuates and also VDG at IDIFF,MAX with VF which is the characteristic voltage of IDIFF, The relations are studied and some related expressions are given.
基金Taif University Researchers are supporting project number(TURSP-2020/216),Taif University,Taif,Saudi Arabia.
文摘This research analyzes and implements an innovative and tiny ultrawideband(UWB)antenna with band-notched features for body-centric communication.The shape of the designed antenna looks like a‘swan’with a slotted patch.Computer Simulation Technology(CST)is used to assess and investigate the performance of this antenna.With a band notch,this antenna can prevent interference from Wireless Local Area Network(WLAN)(5.15–5.825 GHz)and Worldwide Interoperability for Microwave Access(WiMAX)(5.25–5.85 GHz)systems.At first,the performance parameters like return loss response,gain,radiation patterns,and radiation efficiency of this UWB antenna are evaluated.After that,the human body effects on the antenna performance of the antenna are also examined to place the antenna at various distances away from 3-layers of phantom body model at different frequencies.All the on-body performance parameter results are compared and analyzed with free space performance parameter results.Lastly,by changing patch slot length and ground plane length,parametric studies were done for performance comparison.According to this research,it is noticed that the antenna is tiny and new.It shows good performance in body case as well.Hence,the antenna is very suitable for healthcare applications.