Previous quasi-static cyclic tests of shear walls,which routinely used an incremental lateral displacement test protocol with a constant axial load,failed to reflect the character of moment-shear force interaction of ...Previous quasi-static cyclic tests of shear walls,which routinely used an incremental lateral displacement test protocol with a constant axial load,failed to reflect the character of moment-shear force interaction of prototype buildings.To study the effect of the moment-shear force interaction on the seismic performance of shear walls,three identical 2-story shear wall specimens with different loading patterns were constructed at 1/2 scale,to represent the lower portion of an 11-story high-rise building,and were tested under reversed cyclic loads.The axial force,shear force and bending moment were simultaneously applied to simulate the effects of gravity loads and earthquake excitations on the prototype.The axial force and bending moment delivered from the upper structure were applied to the top of the specimens by two vertical actuators,and the shear force was applied to the specimens by two horizontal actuators.A mixed force-displacement control test program was adopted to ensure that the bending moment and the lateral shear were increased proportionally.The experimental results show that the moment-shear force interaction had a significant effect on the failure pattern,hysteretic characteristics,ductility and energy dissipation of the specimens.It is recommended that moment-shear force interaction should be considered in the loading condition of RC shear wall substructures cyclic tests.展开更多
In slab column-shear wall structures,both the whole structure′s seismic behavior and failure mode are greatly influenced by the distribution of horizontal seismic forces between slab-column and shear wall.In this pap...In slab column-shear wall structures,both the whole structure′s seismic behavior and failure mode are greatly influenced by the distribution of horizontal seismic forces between slab-column and shear wall.In this paper,a pushover analysis of topical slab column-shear wall structure was carried out,the seismic shear force that the slab-column and shear wall should undertake was worked out,the influences of plastic internal force redistribution and structure stiffness characteristic value on horizontal seismic distribution were studied and the calculation formula was given.The analysis results showed that with the yield of the shear walls,the story shear force was undertaken by slab-columns correspondingly increased while with the decrease of characteristic value of stiffness of a structure,and the horizontal seismic force was undertaken by slab-columns correspondingly decreased.According to the code,the design of horizontal force distribution may be cause insecurity problems,so it is necessary to give the distribution law of horizontal seismic forces in slab-column shear wall structures as the supplement to the corresponding regulation of the Code.展开更多
基金Scientific Research Fund of Institute of Engineering Mechanics,China Earthquake Administration under Grant No.2019B05the Heilongjiang Provincial Natural Science Foundation of China under Grant No.LH2019E098,the National Natural Science Foundation of China under Grant Nos.51878631 and 51678544the National Key Research and Development Program of China under Grant Nos.2017YFC1500605 and 2018YFC1504602-01。
文摘Previous quasi-static cyclic tests of shear walls,which routinely used an incremental lateral displacement test protocol with a constant axial load,failed to reflect the character of moment-shear force interaction of prototype buildings.To study the effect of the moment-shear force interaction on the seismic performance of shear walls,three identical 2-story shear wall specimens with different loading patterns were constructed at 1/2 scale,to represent the lower portion of an 11-story high-rise building,and were tested under reversed cyclic loads.The axial force,shear force and bending moment were simultaneously applied to simulate the effects of gravity loads and earthquake excitations on the prototype.The axial force and bending moment delivered from the upper structure were applied to the top of the specimens by two vertical actuators,and the shear force was applied to the specimens by two horizontal actuators.A mixed force-displacement control test program was adopted to ensure that the bending moment and the lateral shear were increased proportionally.The experimental results show that the moment-shear force interaction had a significant effect on the failure pattern,hysteretic characteristics,ductility and energy dissipation of the specimens.It is recommended that moment-shear force interaction should be considered in the loading condition of RC shear wall substructures cyclic tests.
文摘In slab column-shear wall structures,both the whole structure′s seismic behavior and failure mode are greatly influenced by the distribution of horizontal seismic forces between slab-column and shear wall.In this paper,a pushover analysis of topical slab column-shear wall structure was carried out,the seismic shear force that the slab-column and shear wall should undertake was worked out,the influences of plastic internal force redistribution and structure stiffness characteristic value on horizontal seismic distribution were studied and the calculation formula was given.The analysis results showed that with the yield of the shear walls,the story shear force was undertaken by slab-columns correspondingly increased while with the decrease of characteristic value of stiffness of a structure,and the horizontal seismic force was undertaken by slab-columns correspondingly decreased.According to the code,the design of horizontal force distribution may be cause insecurity problems,so it is necessary to give the distribution law of horizontal seismic forces in slab-column shear wall structures as the supplement to the corresponding regulation of the Code.