The paper proposes a novel H∞ load frequency control(LFC) design method for multi-area power systems based on an integral-based non-fragile distributed fixed-order dynamic output feedback(DOF) tracking-regulator cont...The paper proposes a novel H∞ load frequency control(LFC) design method for multi-area power systems based on an integral-based non-fragile distributed fixed-order dynamic output feedback(DOF) tracking-regulator control scheme. To this end, we consider a nonlinear interconnected model for multiarea power systems which also include uncertainties and timevarying communication delays. The design procedure is formulated using semi-definite programming and linear matrix inequality(LMI) method. The solution of the proposed LMIs returns necessary parameters for the tracking controllers such that the impact of model uncertainty and load disturbances are minimized. The proposed controllers are capable of receiving all or part of subsystems information, whereas the outputs of each controller are local. These controllers are designed such that the resilient stability of the overall closed-loop system is guaranteed. Simulation results are provided to verify the effectiveness of the proposed scheme. Simulation results quantify that the distributed(and decentralized) controlled system behaves well in presence of large parameter perturbations and random disturbances on the power system.展开更多
The full bridge zero voltage zero current switching ( FB-ZVZCS ) , which could adjust the output power by keeping the duty ratio of lagging leg constant and changing the duty ratio of leading leg, was a common circu...The full bridge zero voltage zero current switching ( FB-ZVZCS ) , which could adjust the output power by keeping the duty ratio of lagging leg constant and changing the duty ratio of leading leg, was a common circuit of soft switching arc welding inverter power source. However, when the duty ratio of leading leg was reduced to zero, the output power stayed the constant value instead of becoming zero. The working status and waveforms of some major parameters were studied in this paper while the duty ratio of leading leg was zero. It was concluded that the minimum output power of soft switching inverter was related to the charging voltage of paraUel capacitors, and the output power also could be reduced by reducing the duty ratio of lagging leg. A novel two-stage continuous PWM control method that could switch working-mode between full bridge and half bridge was put forward in this paper. This kind of control method could further reduce the output power of soft switching inverter in order to meet the requirement of low heat input of sheet metal welding.展开更多
In this paper, an optimal control scheme for wind turbine output torque and power regulation under the influence of wind disturbances is presented. The system considered is a dynamic mechanical-based model with pitch ...In this paper, an optimal control scheme for wind turbine output torque and power regulation under the influence of wind disturbances is presented. The system considered is a dynamic mechanical-based model with pitch and generator torque actuators for controlling the pitch and generator torque. The performance of linear matrix inequality (LMI) formalism of linear quadratic regulator (LQR);linear quadratic regulator with integral action (LQRI) and model predictive control (MPC) were compared in response to a step change in wind disturbance. It is shown by Matlab simulation that the LQRI outperformed both LQR and MPC controllers.展开更多
压水堆的安全性会受到控制性能和扰动的影响,为了及时检测控制器的控制性能,避免整个系统的崩溃,基于输出分布控制(output distribution control,ODC)理论,提出了一种在线控制性能评价系统。系统采用基于巴氏性能指标的性能评估方法,提...压水堆的安全性会受到控制性能和扰动的影响,为了及时检测控制器的控制性能,避免整个系统的崩溃,基于输出分布控制(output distribution control,ODC)理论,提出了一种在线控制性能评价系统。系统采用基于巴氏性能指标的性能评估方法,提高了性能评价的准确性和敏感性。并考虑了实时I/O数据和历史I/O数据的概率分布,利用滑动窗进行输出概率分布的更新,增大性能指标统计数据的范围。仿真结果表明,该在线控制性能评价系统对于控制效果的波动有准确的判断,同时也能排除控制过程中的非高斯扰动,避免影响性能评价。展开更多
文摘The paper proposes a novel H∞ load frequency control(LFC) design method for multi-area power systems based on an integral-based non-fragile distributed fixed-order dynamic output feedback(DOF) tracking-regulator control scheme. To this end, we consider a nonlinear interconnected model for multiarea power systems which also include uncertainties and timevarying communication delays. The design procedure is formulated using semi-definite programming and linear matrix inequality(LMI) method. The solution of the proposed LMIs returns necessary parameters for the tracking controllers such that the impact of model uncertainty and load disturbances are minimized. The proposed controllers are capable of receiving all or part of subsystems information, whereas the outputs of each controller are local. These controllers are designed such that the resilient stability of the overall closed-loop system is guaranteed. Simulation results are provided to verify the effectiveness of the proposed scheme. Simulation results quantify that the distributed(and decentralized) controlled system behaves well in presence of large parameter perturbations and random disturbances on the power system.
文摘The full bridge zero voltage zero current switching ( FB-ZVZCS ) , which could adjust the output power by keeping the duty ratio of lagging leg constant and changing the duty ratio of leading leg, was a common circuit of soft switching arc welding inverter power source. However, when the duty ratio of leading leg was reduced to zero, the output power stayed the constant value instead of becoming zero. The working status and waveforms of some major parameters were studied in this paper while the duty ratio of leading leg was zero. It was concluded that the minimum output power of soft switching inverter was related to the charging voltage of paraUel capacitors, and the output power also could be reduced by reducing the duty ratio of lagging leg. A novel two-stage continuous PWM control method that could switch working-mode between full bridge and half bridge was put forward in this paper. This kind of control method could further reduce the output power of soft switching inverter in order to meet the requirement of low heat input of sheet metal welding.
基金Supported by National Natural Science Foundation of China(60774010 10971256) Natural Science Foundation of Jiangsu Province(BK2009083)+1 种基金 Program for Fundamental Research of Natural Sciences in Universities of Jiangsu Province(07KJB510114) Shandong Provincial Natural Science Foundation of China(ZR2009GM008 ZR2009AL014)
基金Supported by National Natural Science Foundation of China (60674036), the Science and Technique Development Plan of Shandong Province of China (2004GG4204014), the Program for New Century Excellent Talents in University of China (NCET-07-0513), the Key Science and Technique Foundation of Ministry of Education of China (108079), and the Excellent Young and Middle-Aged Scientist Award Grant of Shandong Province of China (2007BS01010)
文摘In this paper, an optimal control scheme for wind turbine output torque and power regulation under the influence of wind disturbances is presented. The system considered is a dynamic mechanical-based model with pitch and generator torque actuators for controlling the pitch and generator torque. The performance of linear matrix inequality (LMI) formalism of linear quadratic regulator (LQR);linear quadratic regulator with integral action (LQRI) and model predictive control (MPC) were compared in response to a step change in wind disturbance. It is shown by Matlab simulation that the LQRI outperformed both LQR and MPC controllers.
文摘压水堆的安全性会受到控制性能和扰动的影响,为了及时检测控制器的控制性能,避免整个系统的崩溃,基于输出分布控制(output distribution control,ODC)理论,提出了一种在线控制性能评价系统。系统采用基于巴氏性能指标的性能评估方法,提高了性能评价的准确性和敏感性。并考虑了实时I/O数据和历史I/O数据的概率分布,利用滑动窗进行输出概率分布的更新,增大性能指标统计数据的范围。仿真结果表明,该在线控制性能评价系统对于控制效果的波动有准确的判断,同时也能排除控制过程中的非高斯扰动,避免影响性能评价。