A Novel Method for Wet Gas Flow Measurements Based on an Over-Reading Principle
1
作者 Jinjing Zhang Jia Li 《Fluid Dynamics & Materials Processing》 EI 2023年第2期303-313,共11页
A novel method to measure the flow rate in a wet gas is presented.Due to the presence of liquid,there is a deviation in the measurement of the gas volume flow rate obtained with standard vortex flow-meters.The propose... A novel method to measure the flow rate in a wet gas is presented.Due to the presence of liquid,there is a deviation in the measurement of the gas volume flow rate obtained with standard vortex flow-meters.The proposed method is based on a correction factor determined through the application of an over-reading approach to a bluff body in mist flow.The correction factor is obtained from the slip velocity ratio,i.e.,the ratio of droplet velocity to gas velocity,based on the analysis of the fluid velocity distribution in the pipeline section.It also takes into account relevant theoretical arguments.It is shown that the predicted results fit the experimental results well. 展开更多
关键词 over-reading flow measurement correction algorithm
下载PDF
Performance of a Horizontally Mounted Venturi in Low-pressure Wet Gas Flow 被引量:9
2
作者 方立德 张涛 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2008年第2期320-324,共5页
The performance of a Venturi tube used in wet gas flow have been explored mainly under higher-pressure condition, but very often, low-pressure test exists in some oil and gas fields in Tianjin Dagang Oil and Gas Field... The performance of a Venturi tube used in wet gas flow have been explored mainly under higher-pressure condition, but very often, low-pressure test exists in some oil and gas fields in Tianjin Dagang Oil and Gas Field in China. In this study, the performance of horizontally mounted Venturi meters in low-pressure wet gas flow is discussed. Three 50 mm Venturi meters were tested systematically, with fl values of 0.4048, 0.55 and 0.70, the opera- tion pressure of 0.15 MPa, 0.20 MPa, 0.25 MPa, the gas densiometric Froude number from 0.6 to 2.0, the modified Lockhart-Maretinelli parameter from 0.0022 to 0.06, and the ratio of the gas liquid mass flow rate from 0.5 to 0.99. The effects of modified Lockhart-Maretinelli parameter, pressure, gas densiometric Froude number, diameter ratio, and gas-liquid mass flow rate ratio to the Venturi tube are analyzed with new independent data. Furthermore, low-pressure performance was compared with that under high pressure. 展开更多
关键词 gas-liquid two phase flow wet gas metering Venturi meter over-reading