Experimental investigations were performed on the overall cooling effectiveness η of a flat effusion wall over a wide range of blowing ratio(M=0.47~5.27).The effusion wall had a staggered multi-hole pattern typical ...Experimental investigations were performed on the overall cooling effectiveness η of a flat effusion wall over a wide range of blowing ratio(M=0.47~5.27).The effusion wall had a staggered multi-hole pattern typical of gas turbine combustor application,with a ratio of hole pitch to row spacing P/S=1∶2,a porosity PS/d2=72,and an inclination angle α=30°.The current paper documented distribution of the overall cooling effectiveness on the wall surface,based on infrared imaging of the 2-D surface temperature field.Experimental results indicate:(1) The overall η increases along with the streamwise distance for the wide range of M due to the superposition effect of the multi-row film cooling.(2) The overall η substantially benefits from the multi-hole inside convective cooling.The hole convective cooling not only complements the weakest film protection at initial rows but also helps mitigate the temperature gradient.(3) The overall η increases asymptotically with increasing M,unlike adiabatic η mostly published in the past,which decreased after M reached a specific level.The current work showcased the end cooling outcome jointly driven by the filming cooling mechanism and the hole inside convective cooling mechanism.展开更多
Based on the variable characteristics of the actual operating conditions of the turbine shroud and the purpose of improving the cooling effect of the turbine shroud,this paper builds a test system of the impingement-f...Based on the variable characteristics of the actual operating conditions of the turbine shroud and the purpose of improving the cooling effect of the turbine shroud,this paper builds a test system of the impingement-film cooling shroud with two gas inlet angles(90°,167°).The effects of film cooling hole arrangement,gas inlet angle,blowing ratio(0.7,1.0,1.5,2.0,2.5,3.0)and temperature ratio(1.2,1.3,1.4,1.5,1.6)on the cooling characteristics of the impingement-film cooling shroud were experimentally studied by infrared temperature measurement technology,especially the effects of gas inlet angle and temperature ratio.The results showed that the film covering effect of the film cooling hole vertical or the same direction of the high-temperature gas incoming flow is better than the film covering effect of the reverse direction with the incoming flow,and the optimal arrangement of film cooling holes can improve the cooling effectiveness of the shroud.Compared with 90°intake gas,the film coverage area on the shroud surface of the 167°intake gas is expanded,and the surface average overall cooling effectiveness is increased by 1.03%to 12.6%.The overall cooling effectiveness of turbine shroud increases with the increase of blowing ratio,which increases the flow rate and pressure of cooling gas,and the corresponding increase rate is between 1.04%and 9.96%.However,the increase in the temperature ratio increases the mainstream heating capacity,resulting in a decrease in the cooling effectiveness of the shroud,with a maximum reduction rate of 11.04%.展开更多
Film cooling combined with internal impingement cooling is one of the most effective technologies to protect the gas turbine vanes and blades from the hot gas. In this study, conjugate heat transfer CFD study was unde...Film cooling combined with internal impingement cooling is one of the most effective technologies to protect the gas turbine vanes and blades from the hot gas. In this study, conjugate heat transfer CFD study was undertaken for a flat plate with combined film cooling and impingement cooling. An experiment on conjugate heat transfer of a flat plate with combined film and impingement cooling was performed to validate the code. Then the effects of several parameters including Biot number, blowing ratio, film hole shape and impingement hole diameter on the overall cooling effectiveness were numerically studied. The results show that for a specific combined cooling scheme and a given blowing ratio, the coolant potential can be reasonably allocated to the internal and the external cooling to achieve the overall cooling effectiveness. As the blowing ratio increases, the overall cooling effectiveness trends to reach a maximum value. For different film hole geometrical, the maximum values of the overall cooling effectiveness at high blowing ratio approximate to the same value. At a given mass flow rate of coolant, the increase of the impingement hole diameter leads to the reduction of the overall cooling effectiveness.展开更多
文摘Experimental investigations were performed on the overall cooling effectiveness η of a flat effusion wall over a wide range of blowing ratio(M=0.47~5.27).The effusion wall had a staggered multi-hole pattern typical of gas turbine combustor application,with a ratio of hole pitch to row spacing P/S=1∶2,a porosity PS/d2=72,and an inclination angle α=30°.The current paper documented distribution of the overall cooling effectiveness on the wall surface,based on infrared imaging of the 2-D surface temperature field.Experimental results indicate:(1) The overall η increases along with the streamwise distance for the wide range of M due to the superposition effect of the multi-row film cooling.(2) The overall η substantially benefits from the multi-hole inside convective cooling.The hole convective cooling not only complements the weakest film protection at initial rows but also helps mitigate the temperature gradient.(3) The overall η increases asymptotically with increasing M,unlike adiabatic η mostly published in the past,which decreased after M reached a specific level.The current work showcased the end cooling outcome jointly driven by the filming cooling mechanism and the hole inside convective cooling mechanism.
基金The authors are grateful for the supported by China Postdoctoral Science Foundation(NO.2020TQ0147)Natural Science Foundation of Jiangsu Province(NO.BK20200454)the Fundamental Research Funds for the Central Universities(NO.NJ2020014).
文摘Based on the variable characteristics of the actual operating conditions of the turbine shroud and the purpose of improving the cooling effect of the turbine shroud,this paper builds a test system of the impingement-film cooling shroud with two gas inlet angles(90°,167°).The effects of film cooling hole arrangement,gas inlet angle,blowing ratio(0.7,1.0,1.5,2.0,2.5,3.0)and temperature ratio(1.2,1.3,1.4,1.5,1.6)on the cooling characteristics of the impingement-film cooling shroud were experimentally studied by infrared temperature measurement technology,especially the effects of gas inlet angle and temperature ratio.The results showed that the film covering effect of the film cooling hole vertical or the same direction of the high-temperature gas incoming flow is better than the film covering effect of the reverse direction with the incoming flow,and the optimal arrangement of film cooling holes can improve the cooling effectiveness of the shroud.Compared with 90°intake gas,the film coverage area on the shroud surface of the 167°intake gas is expanded,and the surface average overall cooling effectiveness is increased by 1.03%to 12.6%.The overall cooling effectiveness of turbine shroud increases with the increase of blowing ratio,which increases the flow rate and pressure of cooling gas,and the corresponding increase rate is between 1.04%and 9.96%.However,the increase in the temperature ratio increases the mainstream heating capacity,resulting in a decrease in the cooling effectiveness of the shroud,with a maximum reduction rate of 11.04%.
基金financial support from the National Natural Science Foundation of China under Grant No.51776201the National Science Foundation of Tianjin under Grant No.18JCQNJC07200。
文摘Film cooling combined with internal impingement cooling is one of the most effective technologies to protect the gas turbine vanes and blades from the hot gas. In this study, conjugate heat transfer CFD study was undertaken for a flat plate with combined film cooling and impingement cooling. An experiment on conjugate heat transfer of a flat plate with combined film and impingement cooling was performed to validate the code. Then the effects of several parameters including Biot number, blowing ratio, film hole shape and impingement hole diameter on the overall cooling effectiveness were numerically studied. The results show that for a specific combined cooling scheme and a given blowing ratio, the coolant potential can be reasonably allocated to the internal and the external cooling to achieve the overall cooling effectiveness. As the blowing ratio increases, the overall cooling effectiveness trends to reach a maximum value. For different film hole geometrical, the maximum values of the overall cooling effectiveness at high blowing ratio approximate to the same value. At a given mass flow rate of coolant, the increase of the impingement hole diameter leads to the reduction of the overall cooling effectiveness.