CHARACTERISTICS ANALYSIS OF THE INDUCED OVERCURRENT GENERATED BY CLOSE TRIGGERED LIGHTNING ON THE OVERHEAD TRANSMISSION POWER LINE 被引量:8
1
作者 杨少杰 陈绍东 +5 位作者 张义军 董万胜 王建国 周蜜 王孝波 余晖 《Journal of Tropical Meteorology》 SCIE 2010年第1期59-65,共7页
Techniques of artificially-triggered lightning have provided a significantly useful means to directly measure various physical parameters of lightning discharge and to conduct research on protection methods of lightni... Techniques of artificially-triggered lightning have provided a significantly useful means to directly measure various physical parameters of lightning discharge and to conduct research on protection methods of lightning electromagnetic pulses.In this study,using capacitive and resistive dividers,current probes and optical fiber transmission devices,we measured and analyzed the induced overvoltage on the overhead transmission line and the overcurrent through Surge Protective Devices(SPD) when a lightning discharge was artificially triggered nearby on August 12,2008 at Conghua Field Lightning Experiment Site.The triggered lightning discharge contained an initial current stage and eight return strokes whose peak currents ranged from 6.6kA to 26.4kA.We found that overcurrents through SPD were induced on the power line both during the initial continuous current stage and the return stroke processes.During the return strokes,the residual voltage and the current through the SPD lasted up to the ms(millisecond) range,and the overcurrents exhibited a mean waveform up to 22/69μs with a peak value of less than 2kA.Based on the observed data,simple calculations show that the corresponding single discharge energy was much greater than the values of the high voltage pulse generators commonly used in the experiments regulated for SPD.The SPD discharge current peak was not synchronous to that of the residual voltage with the former obviously lagging behind the latter.The SPD discharge current peak was well correlated with the triggered lightning current peak and the wave-front current gradient.The long duration of the SPD current is one of the major reasons why the SPD was damaged even with a big nominal discharge current. 展开更多
关键词 triggered lightning overhead transmission line SPD induced overcurrent
下载PDF
A New Proposal of Inverse-Time Characteristics for Overcurrent Relay Based on Microcomputer 被引量:1
2
作者 黄彦全 肖建 +1 位作者 蔡勇 唐磊 《Journal of Southwest Jiaotong University(English Edition)》 2004年第1期25-28,共4页
The conventional time function of electromechanical relays is hard to coordinate with other relays. In order to promote the application of inverse-time overcurrent relays, a new time function for microprocessor-type r... The conventional time function of electromechanical relays is hard to coordinate with other relays. In order to promote the application of inverse-time overcurrent relays, a new time function for microprocessor-type relay is proposed. The setting of the trip time for this relay is performed by determining the shortest trip time and the longest trip time, respectively. The results of analysis show that with the new time function, the inverse-time overcurrent relay is easy to coordinate with other relays and has a comparatively shorter trip time, and that the fault happens in the protective zone. 展开更多
关键词 Dial setting Inverse-time characteristics overcurrent relays Coordination
下载PDF
IGBT Overcurrent Protection of Welding Inverter Power Source
3
作者 殷树言 耿正 +1 位作者 邵宏 郭大勇 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1996年第1期83-89,共7页
IGBTOvercurrentProtectionofWeldingInverterPowerSourceYINShuyan;GENGZheng;SHAOHong;GUODayong(殷树言);(耿正);(邵宏);(... IGBTOvercurrentProtectionofWeldingInverterPowerSourceYINShuyan;GENGZheng;SHAOHong;GUODayong(殷树言);(耿正);(邵宏);(郭大勇)(Dept.ofMater... 展开更多
关键词 ss: IGBT overcurrent PROTECTION INVERTER
下载PDF
Simulation Analysis of Suppression of Resonant Overcurrent by Nonlinear Components
4
作者 Qiyang Xia Haiming Li Yong Wang 《Journal of Computer and Communications》 2018年第11期264-275,共12页
For the development of distributed power supply active distribution network system, the instability of the power supply side causes the system frequency to be disturbed, and harmonics, voltage fluctuations, or ferroma... For the development of distributed power supply active distribution network system, the instability of the power supply side causes the system frequency to be disturbed, and harmonics, voltage fluctuations, or ferromagnetic saturation causes resonance and other series of power quality problems;what resulting in the over-voltage and over-current can easily damage components and threaten the system's safe and stable operation. In order to solve these problems, this paper compares some harmonic detection and filtering methods, devices and methods for suppressing resonance in recent years, and combines the principle of resonance to design a nonlinear inductive circuit that can suppress resonant overcurrent according to the characteristics of nonlinear inductors. Compared with the Resistance (R) series Induct Capacitance (LC) parallel circuit composed of common inductors, the circuit described in this paper is not affected by overcurrent, and the influence of overvoltage is relatively greatly reduced. The simulate-on proves that this circuit suppresses the effects of resonant overvoltage and overcurrent. 展开更多
关键词 Power Quality RESONANCE NONLINEAR INDUCTANCE SUPPRESSION of overcurrent
下载PDF
Summary of Useful Concepts About the Coordination of Directional Overcurrent Protections 被引量:1
5
作者 Elmer Sorrentino Naren Gupta 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2019年第3期382-390,共9页
This paper summarizes some useful concepts about the coordination of directional overcurrent protections.The following key topics are described:the analysis of systems in a ring configuration and only one source of sh... This paper summarizes some useful concepts about the coordination of directional overcurrent protections.The following key topics are described:the analysis of systems in a ring configuration and only one source of short-circuit currents;the impossibility of obtaining selectivity for all the possible system configurations with multiple sources;the need for inverse functions in order to obtain selectivity in systems with multiple sources;the coordination with protections for radial loads;the coordination between instantaneous and delayed functions;the considerations to select the pickup values;the influence of contributions from motors to short circuit currents;the transient configurations due to sequential trips at both line ends;the influence of dynamic behavior of overcurrent functions;the influence of stability constraints;other specific considerations for ground functions;some specific considerations for systems with distributed generation.A summary of these points and their effect on the coordination of directional overcurrent protections is not available in the current literature.This novel description should facilitate the inclusion of these key points in research and coordination studies related to these protective functions. 展开更多
关键词 Coordination of protective relays directional overcurrent protection directional overcurrent relays directional overcurrent functions power system protection
原文传递
Optimum coordination of directional overcurrent relays for combined overhead/cable distribution system with linear programming technique 被引量:6
6
作者 Sarang V.Khond Gunwant A.Dhomane 《Protection and Control of Modern Power Systems》 2019年第1期116-122,共7页
Heavy fault currents flow in the event of fault at the loads connected in distribution system. To protect these loads, circuit breakers and relays are required at appropriate places with proper coordination between th... Heavy fault currents flow in the event of fault at the loads connected in distribution system. To protect these loads, circuit breakers and relays are required at appropriate places with proper coordination between them. This research paper focuses on finding optimum relay setting required for minimum time to interrupt power supply to avoid miscoordination in operation of relays and also investigates effect on time multiplier settings (TMS) of directional overcurrent relays in a system with combined overhead lines-underground cables. Linear programming problem (LPP) approach is used for optimization. It is interesting to know the quantitative variations in TMS as the underground cables have different characteristics than overhead lines. 展开更多
关键词 Dual simplex method Linear programming Optimization overcurrent relay coordination Power distribution system
原文传递
Coordination of dual setting overcurrent relays in microgrid with optimally determined relay characteristics for dual operating modes 被引量:1
7
作者 Raghvendra Tiwari Ravindra Kumar Singh Niraj Kumar Choudhary 《Protection and Control of Modern Power Systems》 2022年第1期64-81,共18页
Fault current magnitude in a microgrid depends upon its mode of operation,namely,grid-connected mode or islanded mode.Depending on the type of fault in a given mode,separate protection schemes are generally employed.W... Fault current magnitude in a microgrid depends upon its mode of operation,namely,grid-connected mode or islanded mode.Depending on the type of fault in a given mode,separate protection schemes are generally employed.With the change in microgrid operating mode,the protection scheme needs to be modified which is uneconomical and time inefficient.In this paper,a novel optimal protection coordination scheme is proposed,one which enables a common optimal relay setting which is valid in both operating modes of the microgrid.In this con-text,a common optimal protection scheme is introduced for dual setting directional overcurrent relays(DOCRs)using a combination of various standard relay characteristics.Along with the two variables,i.e.,time multiplier setting(TMS)and plug setting(PS)for conventional directional overcurrent relay,dual setting DOCRs are augmented with a third variable of relay characteristics identifier(RCI),which is responsible for selecting optimal relay characteristics from the standard relay characteristics according to the IEC-60255 standard.The relay coordination problem is formulated as a mixed-integer nonlinear programming(MINLP)problem,and the settings of relays are optimally determined using the genetic algorithm(GA)and the grey wolf optimization(GWO)algorithm.To validate the superiority of the pro-posed protection scheme,the distribution parts of the IEEE-14 and IEEE-30 bus benchmark systems are considered. 展开更多
关键词 Plug setting Time multiplier setting Protection coordination overcurrent relay Coordination time interval
原文传递
Optimal Coordination of Directional Overcurrent Relays in Meshed Active Distribution Network Using Imperialistic Competition Algorithm
8
作者 Pegah Alaee Turaj Amraee 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第2期416-422,共7页
The optimal setting of directional overcurrent relays(DOCRs)ensures the fault detection and clearing in the minimum possible operation time.Directional protective relaying is carried out to coordinate relay settings i... The optimal setting of directional overcurrent relays(DOCRs)ensures the fault detection and clearing in the minimum possible operation time.Directional protective relaying is carried out to coordinate relay settings in a meshed network in the presence of distributed generation.The main goal of DOCR coordination is to find the optimal time dial setting(TDS)and pickup multiplier setting(PMS)to reach the minimum total operation time of all primary relays in the presence of coordination constraints.Due to the complexity of mixed integer non-linear programming(MINLP)problem,imperialistic competition algorithm(ICA)as a powerful evolutionary algorithm is used to solve the coordination problem of DOCRs.The proposed DOCR coordination formulation is implemented in three different test cases.The results are compared with the standard branch-and-bound algorithm and other meta-heuristic optimization algorithms,which demonstrates the effectiveness of the proposed algorithm. 展开更多
关键词 Directional overcurrent relay(DOCR) COORDINATION imperialistic competition algorithm(ICA) standard branch-and-bound algorithm
原文传递
Preparation and Properties of PTC Material with Low Resistivity
9
作者 黄仲臧 《High Technology Letters》 EI CAS 1996年第1期77-80,共4页
The demand for PTC material for overcurrent protection application in automobile mo-tors has been remarkably increasing.To meet the safety and reliability requirements in auto-mobile system and communication equipment... The demand for PTC material for overcurrent protection application in automobile mo-tors has been remarkably increasing.To meet the safety and reliability requirements in auto-mobile system and communication equipment,it is necessary to prepare PTC material withlow resistivity and high performance.In this paper,the preparation and the properties ofPTC material with a resistivity of~12Ω.cm,especially its overcurrent protection are de-scribed. 展开更多
关键词 PTC MATERIAL LOW RESISTIVITY overcurrent PROTECTION
下载PDF
Simulation of Power Flow and Protection of a Limited Bus Grid System with Injected Solar Power
10
作者 Nader Barsoum Chai Zen Lee 《Energy and Power Engineering》 2013年第1期59-69,共11页
In recent years, injection of renewable energy such as solar power into the power grid is increasing. However, inclusion of large-scale intermittent-type renewable energy requires better management in proper understan... In recent years, injection of renewable energy such as solar power into the power grid is increasing. However, inclusion of large-scale intermittent-type renewable energy requires better management in proper understanding of grid’s variable characteristics and its protection systems. In this paper, the investigation on overvoltage issue is illustrated. Overvoltage in distribution feeder occurs when large amount of solar power is injected at low power demand. Another investigation is on false operation of overcurrent relays due to reverse power to the 33 kV loads. The potential solutions to the two issues are illustrated in the small-sized power grid system using bi-directional inverters on AC buses in charging battery banks and adjusting the relay current settings. The benefits of solar power injection are illustrated whereby output power from generators is decreased and transmission losses are reduced. Electrical Transient Analysis Program (ETAP) was used for investigations. 展开更多
关键词 Grid Systems Solar Power OVERVOLTAGE overcurrent RELAY Bi-Directional INVERTER RELAY Current SETTING
下载PDF
Mitigation of Distributed Generation Impact on Protective Devices in a Distribution Network by Superconducting Fault Current Limiter
11
作者 Yu Zhao Yong Li +1 位作者 Tapan Kumar Saha Olav Krause 《Energy and Power Engineering》 2013年第4期258-263,共6页
Protection of radial distribution networks is widely based on coordinated inverse time overcurrent relays (OCRs) ensuring both effectiveness and selectivity. However, the integration of distributed generation (DG) int... Protection of radial distribution networks is widely based on coordinated inverse time overcurrent relays (OCRs) ensuring both effectiveness and selectivity. However, the integration of distributed generation (DG) into an existing distribution network not only inevitably increases fault current levels to levels that may exceed the OCR ratings, but it may also disturb the original overcurrent relay coordination adversely effecting protection selectivity. To analyze the potentially adverse impact of DG on distribution system protective devices with respect to circuit breaker ratings and OCR coordination fault current studies are carried out for common reference test system under the influence of additional DG. The possible advantages of Superconducting Fault Current Limiter (SFCL) as a means to limit the adverse effect of DG on distribution system protection and their effectiveness will be demonstrated. Furthermore, minimum SFCL impedances required to avoid miss-operation of the primary and back-up OCRs are determined. The theoretical analysis will be validated using the IEEE 13-bus distribution test system is used. Both theoretical and simulation results indicate that the proposed application of SFCL is a viable option to effectively mitigate the DG impact on protective devices, thus enhancing the reliability of distribution network interfaced with DG. 展开更多
关键词 overcurrent Relay (OCR) Distribution Protection Coordination Distributed Generation (DG) FAULT CURRENT Superconducting FAULT CURRENT LIMITER (SFCL)
下载PDF
ACS800变频器过流故障的分析和处理
12
作者 王国强 《湖南造纸》 2015年第3期39-40,共2页
本文将简单分析ABB公司的ACS800变频器过流故障(2310)的产生,结合本人的实际工作经历,列举一种较为少见的过流故障,即由于控制信号被干扰而产生的过流保护及相应的处理方法,并简单介绍ACS800的自定义编程功能应用。
关键词 变频器 overcurrent
下载PDF
IEC61850 standard-based harmonic blocking scheme for power transformers 被引量:9
13
作者 Senthil Krishnamurthy Bwandakassy Elenga Baningobera 《Protection and Control of Modern Power Systems》 2019年第1期123-137,共15页
Transformer Differential and overcurrent schemes are traditionally used as main and backup protection respectively. The differential protection relay (SEL487E) has dedicated harmonic restraint function which blocks th... Transformer Differential and overcurrent schemes are traditionally used as main and backup protection respectively. The differential protection relay (SEL487E) has dedicated harmonic restraint function which blocks the relay tripping during the transformer magnetizing inrush conditions. However, the backup overcurrent relay (SEL751A) applied to the transformer protection does not have harmonic restraint element and trip the overcurrent relay during the inrush conditions. Therefore, major contribution of this research work is the developed harmonic blocking scheme for transformer which uses element (87HB) of the transformer differential relay (SEL487E) to send an IEC61850 GOOSE-based harmonic blocking signal to the backup overcurrent relay (SEL751A) to inhibit from tripping during the transformer magnetizing inrush current conditions. The simulation results proved that IEC61850 standard-based protection scheme is faster than the hardwired signals. Therefore, the speed and reliability of the transformer scheme are improved using the IEC61850 standard-based GOOSE applications. 展开更多
关键词 Transformer protection overcurrent protection Digital protection scheme Current differential protection Transformer magnetizing inrush current Harmonic blocking IEC 61850 GOOSE message
原文传递
Transient stability enhancement of DC-connected DFIG and its converter system using fault protective device 被引量:2
14
作者 Shaomin YAN Aimin ZHANG +2 位作者 Hang ZHANG Jianhua WANG Bin CAI 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第6期887-896,共10页
Transient stability of doubly-fed induction generators(DFIGs)is a major concern in both AC and DC grids,and DFIGs must stay connected for a time during grid faults according to the power grid requirements.For this pur... Transient stability of doubly-fed induction generators(DFIGs)is a major concern in both AC and DC grids,and DFIGs must stay connected for a time during grid faults according to the power grid requirements.For this purpose,this work proposes an overcurrent and overvoltage protective device(OCV-PD)to ensure that DCbased DFIG system can stay connected and operate well during the faults.Compared with a series dynamic braking resistor(SDBR),two aspects are improved.First,a twolevel control strategy and DC inductor circuit are used to ensure that the OCV-PD can limit the current impulse to protect DFIG system during an overcurrent fault.Second,the OCV-PD can protect system from overvoltage fault which a SDBR cannot do.Simulation results verify itsvalidity and feasibility,finding that for overcurrent protection the OCV-PD outperforms a SDBR with an average decreased index of 3.29%,and for overvoltage protection it achieves an average index of 1.02%. 展开更多
关键词 Transient stability Doubly-fed induction generator(DFIG) overcurrent and overvoltage protective device(OCV-PD) DC grid Series dynamic braking resistor(SDBR)
原文传递
Fast Protection Scheme for Active Distribution Networks: Breaking Chains by Utilizing Auxiliary Relays 被引量:1
15
作者 Amin Yazdaninejadi Daryoush Nazarpour Vahid Talavat 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2020年第3期540-548,共9页
Due to the swift expansion and the deployment of distributed generation, protection systems of active distribution networks are more expected to be fast. In loop-based active distribution networks, directional overcur... Due to the swift expansion and the deployment of distributed generation, protection systems of active distribution networks are more expected to be fast. In loop-based active distribution networks, directional overcurrent relays(DOCRs) are caught in different chains. These chains stand as the severe obstacle to follow fast-response protection, which remains a significant challenge. In this paper, to overcome this challenge, a fast protection scheme is proposed to break the chains in the corresponding loops by deploying auxiliary DOCRs. The most effective constraint associated with each chain is relaxed during the coordination process. Then, the auxiliary relays are employed to play the backup roles instead of conventional backup relays in the relaxed constraints. To avoid the misoperation of relays in the proposed scheme, low bandwidth communication links are suitably employed. Furthermore, the auxiliary relays are optimally placed and adjusted. The proposed approach demonstrates a mixed-integer nonlinear programming model which is tackled by particle swarm optimization(PSO) algorithm. Detailed simulation studies are carried out to verify the performance of the proposed approach. 展开更多
关键词 Fast protection scheme directional overcurrent relays active distribution network backup relay auxiliary relay
原文传递
A single lithium-ion battery protection circuit with high reliability and low power consumption
16
作者 江金光 李森 《Journal of Semiconductors》 EI CAS CSCD 2014年第11期154-160,共7页
A single lithium-ion battery protection circuit with high reliability and low power consumption is proposed. The protection circuit has high reliability because the voltage and current of the battery are controlled in... A single lithium-ion battery protection circuit with high reliability and low power consumption is proposed. The protection circuit has high reliability because the voltage and current of the battery are controlled in a safe range. The protection circuit can immediately activate a protective function when the voltage and current of the battery are beyond the safe range. In order to reduce the circuit's power consumption, a sleep state control circuit is developed. Additionally, the output frequency of the ring oscillation can be adjusted continuously and precisely by the charging capacitors and the constant-current source. The proposed protection circuit is fabricated in a 0.5 μm mixed-signal CMOS process. The measured reference voltage is 1.19 V, the overvoltage is 4.2 V and the undervoltage is 2.2 V. The total power is about 9 μW. 展开更多
关键词 lithium-ion battery: OV UV reference voltage: overcurrent (OCk short circuit (SC)