期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Overlapped peaks resolution for linear sweep polarography using Gaussian-like distribution 被引量:2
1
作者 朱红求 王国伟 +2 位作者 阳春华 曹宇 桂卫华 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2013年第7期2181-2186,共6页
A resolution method based on Gaussian-like distribution for overlapped linear sweep polarographic peaks was proposed to simultaneously detect the polymetallic components, such as Zn(Ⅱ) and Co(Ⅱ), coexisting in t... A resolution method based on Gaussian-like distribution for overlapped linear sweep polarographic peaks was proposed to simultaneously detect the polymetallic components, such as Zn(Ⅱ) and Co(Ⅱ), coexisting in the leaching solution of zinc hydrometallurgy. A Gaussian-like distribution was constructed as the sub-model of overlapped peaks by analyzing the characteristics of linear sweep polarographic curve. Then, the abscissas of each peak and trough were pinpointed through multi-resolution wavelet decomposition, the curve and its derivative curves were fitted by using nonlinear weighted least squares (NWLS). Finally, overlapped peaks were resolved into independent sub-peaks based on fitted reconstruction parameters. The experimental results show that the relative error of half-wave potential pinpointed by multi-resolution wavelet decomposition is less than 1% and the accuracy of Ip fitted by NWLS is higher than 96%. The proposed resolution method is effective for overlapped linear sweep polarographic peaks of Zn(Ⅱ) and Co(Ⅱ). 展开更多
关键词 zinc hydrometallurgy Gaussian-like distribution overlapped peaks resolution multi-resolution wavelet decomposition nonlinear weighted least squares fitting
下载PDF
A New Method to Resolve Overlapped Voltammetric Peaks
2
作者 Yong Qing ZHANG Dong Nin LIAO +1 位作者 Jin Yuan MO Pei Xiang CAI 《Chinese Chemical Letters》 SCIE CAS CSCD 2002年第1期73-74,共2页
A new method called spline convolution (SC) for resolving overlapped peaks was proposed in this paper. The differential pulse voltammetric overlapped peaks of mixtures of Pb(II) and Tl(I) were investigated by this me... A new method called spline convolution (SC) for resolving overlapped peaks was proposed in this paper. The differential pulse voltammetric overlapped peaks of mixtures of Pb(II) and Tl(I) were investigated by this method, and satisfactory results were obtained. The results show excellent correlation between peak areas of the processed signals and the concentrations. 展开更多
关键词 Spline convolution (SC) peak resolving function overlapped voltammetric peaks
下载PDF
A chemometric method to identify selective ion for resolution of overlapping gas chromatography-mass spectrometry signal
3
作者 MEI Zhen DU GuoRong +1 位作者 CAI WenSheng SHAO XueGuang 《Science China Chemistry》 SCIE EI CAS 2013年第5期656-663,共8页
A chemometric method to determine selective ion by using non-negative immune algorithm (NNIA) was proposed. In the method, the mutual projections of the chromatographic profiles at different m/z channel are calculat... A chemometric method to determine selective ion by using non-negative immune algorithm (NNIA) was proposed. In the method, the mutual projections of the chromatographic profiles at different m/z channel are calculated using NNIA. Suppose a GC-MS data with m retention time points and n mass channels, the projections of the GC-MS data onto a chromatographic profile at a mass channel will form a mass spectrum of ln vector. If the chromatographic profile at a selective mass channel is used, the extracted mass spectrum will be a correct one. Therefore, by comparing the extracted mass spectrum with a reference spectrum, the selective ion can be identified, and the corresponding chromatographic profile can be obtained at the same time. GC-MS data of 40-pesticide mixture was investigated by the method. The results show that both the mass spectral and the chromatographic information of the interested components can be extracted from the overlapping signals, except for the special cases of isomeric components with very similar mass spectra. 展开更多
关键词 gas chromatography-mass spectrometry selective ion detection immune algorithm CHEMOMETRICS resolution of overlapping peak
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部