This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on...This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on the reliability index and the reli- ability level, the reliability examination plan was analyzed and a test device for the overload protection of moulded case cir- cuit-breaker was developed. In the reliability test of overload protection, two power sources were used, which reduced the time of conversion and regulation between two different test currents in the overload protection test, which made the characteristic test more accurate. The test device was designed on the base of a Windows system, which made its operation simple and friendly.展开更多
System control and safety reliability are important links of the marine DC (Direct Current) power system. The simulationmodel is built by Matlab/Simulink, the battery and super-capacitor are supplied to the system thr...System control and safety reliability are important links of the marine DC (Direct Current) power system. The simulationmodel is built by Matlab/Simulink, the battery and super-capacitor are supplied to the system through a three-phase interleaved DC/DCconverter, the fuse and disconnector switch combination are used as the protection device, and the short-circuit point is set betweeneach branch and the DC distribution board, performing short-circuit simulation. This paper also proposes a short-circuit calculationmethod for super-capacitors based on the simplified model of series RC (Resistors & Capacitors), and verifies its correctness throughsimulation data. The results show that the introduction of a three-phase interleaved DC/DC converter reduces the current ripple andmakes the system control more convenient;short-circuit calculation and simulation have determined the short-circuit withstandcapability of the DC distribution board, and verified the feasibility of the fuse selection method and the short-circuit calculation methodof the super-capacitor. This provides reliable verification for the application and calculation of the actual project.展开更多
Thermal overload relays are economic electromechanical protection devices which offers reliable protection for electric motors in the event of overload or phase failure. Presently there are two types of overload relay...Thermal overload relays are economic electromechanical protection devices which offers reliable protection for electric motors in the event of overload or phase failure. Presently there are two types of overload relays which depend on the temperature characteristics of metals to provide protection by tripping the circuit. These relays lack accuracy as they do not activate the trip circuit at any exact specified temperature. In this paper we introduce a new form of thermal over-load relay actuated by ferrofluid. The ferrofluid has a very accurate transition temperature known as curie temperature. It acts as a ferromagnetic material below the curie temperature and loses the property of ferromagnetism above this temperature. By using this property of the fluid we propose an alternative method for more accurate op-eration under overload condition. This relay finds application in the protection system of electrical machines. Thus, in this paper we present a novel and simple technique for protection against thermal overloading using ferrofluid.展开更多
基金Project (No. E2005000039) supported by the Natural Science Foun-dation of Hebei Province, China
文摘This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on the reliability index and the reli- ability level, the reliability examination plan was analyzed and a test device for the overload protection of moulded case cir- cuit-breaker was developed. In the reliability test of overload protection, two power sources were used, which reduced the time of conversion and regulation between two different test currents in the overload protection test, which made the characteristic test more accurate. The test device was designed on the base of a Windows system, which made its operation simple and friendly.
文摘System control and safety reliability are important links of the marine DC (Direct Current) power system. The simulationmodel is built by Matlab/Simulink, the battery and super-capacitor are supplied to the system through a three-phase interleaved DC/DCconverter, the fuse and disconnector switch combination are used as the protection device, and the short-circuit point is set betweeneach branch and the DC distribution board, performing short-circuit simulation. This paper also proposes a short-circuit calculationmethod for super-capacitors based on the simplified model of series RC (Resistors & Capacitors), and verifies its correctness throughsimulation data. The results show that the introduction of a three-phase interleaved DC/DC converter reduces the current ripple andmakes the system control more convenient;short-circuit calculation and simulation have determined the short-circuit withstandcapability of the DC distribution board, and verified the feasibility of the fuse selection method and the short-circuit calculation methodof the super-capacitor. This provides reliable verification for the application and calculation of the actual project.
文摘Thermal overload relays are economic electromechanical protection devices which offers reliable protection for electric motors in the event of overload or phase failure. Presently there are two types of overload relays which depend on the temperature characteristics of metals to provide protection by tripping the circuit. These relays lack accuracy as they do not activate the trip circuit at any exact specified temperature. In this paper we introduce a new form of thermal over-load relay actuated by ferrofluid. The ferrofluid has a very accurate transition temperature known as curie temperature. It acts as a ferromagnetic material below the curie temperature and loses the property of ferromagnetism above this temperature. By using this property of the fluid we propose an alternative method for more accurate op-eration under overload condition. This relay finds application in the protection system of electrical machines. Thus, in this paper we present a novel and simple technique for protection against thermal overloading using ferrofluid.