Quantitative oxygen detection,especially at low concentrations,holds significant importance in the realms of biology,complex environments,and chemical process engineering.Due to the high sensitivity and rapid response...Quantitative oxygen detection,especially at low concentrations,holds significant importance in the realms of biology,complex environments,and chemical process engineering.Due to the high sensitivity and rapid response of the triplet excitons of phosphorescence to oxygen,pure organic room-temperature phosphorescence(RTP)materials have garnered widespread attention in recent years for oxygen detection.However,simultaneously achieving ultralong phosphorescence at room temperature and quantitative oxygen detection from pure organic host-guest doped materials poses challenges.The d ensely packed materials may decrease non-radiative decay to increase the phosphorescence,but are unsuitable for oxygen diffusion in oxygen detection.Herein,the oxygen sensitivity of host-guest doped RTP materials using 4-bromo-N,N-bis(4-(tertbutyl)phenyl)aniline(TPABuBr)as the host and 6-bromo-2-butyl-1H-benzo[de]isoquinoline-1,3(2H)-dione(NIBr)as the guest was developed.The doped material exhibits fluorescence-phosphorescence dual-emission behavior at room temperature.The tert-butyl groups in TPABuBr facilitate appropriate intermolecular spacing in the crystal state,enhancing oxygen permeability.Therefore,oxygen penetration can quench the phosphorescence emission.The observed linear relationship between the phosphorescence intensity of the doped material and the oxygen volume fraction conforms to the Stern-Volmer equation,suggesting its potential for quantitative analysis of oxygen concentration.The calculated limit of detection is 0.015%(φ),enabling the analysis of oxygen with a volume fraction of less than 2.5%(φ).Moreover,the doped materials demonstrate rapid response and excellent photostability,indicating their potential utility as oxygen sensors.This study elucidates the design and characteristics of NIBr/TPABuBr doped materials,highlighting their potential application in oxygen concentration detection and offering insights for the design of oxygen sensors.展开更多
A portable analog lock-in amplifier capable of accurate phase detection is proposed in this paper. The proposed lock-in amplifier, which uses the dual-channel orthometric signals as the references to build the xy coor...A portable analog lock-in amplifier capable of accurate phase detection is proposed in this paper. The proposed lock-in amplifier, which uses the dual-channel orthometric signals as the references to build the xy coordinate system, can detect the relative phase between the input and x-axis based on trigonometric function. The sensitivity of the phase measurement reaches 0.014degree, and a detection precision of 0.1 degree is achieved. At the same time, the performance of the lock-in amplifier is verified in the high precision optical oxygen concentration detection. Experimental results reveal that the portable analog lock-in amplifier is accurate for phase detection applications. In the oxygen sensing experiments, 0.058% oxygen concentration resulted in 0.1 degree phase shift detected by the lock-in amplifier precisely. In addition, the lock-in amplifier is small and economical compared with the commercial lock-in equipments, so it can be easily integrated in many portable devices for industrial applications.展开更多
文摘Quantitative oxygen detection,especially at low concentrations,holds significant importance in the realms of biology,complex environments,and chemical process engineering.Due to the high sensitivity and rapid response of the triplet excitons of phosphorescence to oxygen,pure organic room-temperature phosphorescence(RTP)materials have garnered widespread attention in recent years for oxygen detection.However,simultaneously achieving ultralong phosphorescence at room temperature and quantitative oxygen detection from pure organic host-guest doped materials poses challenges.The d ensely packed materials may decrease non-radiative decay to increase the phosphorescence,but are unsuitable for oxygen diffusion in oxygen detection.Herein,the oxygen sensitivity of host-guest doped RTP materials using 4-bromo-N,N-bis(4-(tertbutyl)phenyl)aniline(TPABuBr)as the host and 6-bromo-2-butyl-1H-benzo[de]isoquinoline-1,3(2H)-dione(NIBr)as the guest was developed.The doped material exhibits fluorescence-phosphorescence dual-emission behavior at room temperature.The tert-butyl groups in TPABuBr facilitate appropriate intermolecular spacing in the crystal state,enhancing oxygen permeability.Therefore,oxygen penetration can quench the phosphorescence emission.The observed linear relationship between the phosphorescence intensity of the doped material and the oxygen volume fraction conforms to the Stern-Volmer equation,suggesting its potential for quantitative analysis of oxygen concentration.The calculated limit of detection is 0.015%(φ),enabling the analysis of oxygen with a volume fraction of less than 2.5%(φ).Moreover,the doped materials demonstrate rapid response and excellent photostability,indicating their potential utility as oxygen sensors.This study elucidates the design and characteristics of NIBr/TPABuBr doped materials,highlighting their potential application in oxygen concentration detection and offering insights for the design of oxygen sensors.
文摘A portable analog lock-in amplifier capable of accurate phase detection is proposed in this paper. The proposed lock-in amplifier, which uses the dual-channel orthometric signals as the references to build the xy coordinate system, can detect the relative phase between the input and x-axis based on trigonometric function. The sensitivity of the phase measurement reaches 0.014degree, and a detection precision of 0.1 degree is achieved. At the same time, the performance of the lock-in amplifier is verified in the high precision optical oxygen concentration detection. Experimental results reveal that the portable analog lock-in amplifier is accurate for phase detection applications. In the oxygen sensing experiments, 0.058% oxygen concentration resulted in 0.1 degree phase shift detected by the lock-in amplifier precisely. In addition, the lock-in amplifier is small and economical compared with the commercial lock-in equipments, so it can be easily integrated in many portable devices for industrial applications.