期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
A new radical way to N,N-dimethylaniline hydroperoxide (DMAHP) and its application in organic synthesis
1
作者 Yi Xu Shi Lei Zhang Wen Hu Duan 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第7期807-810,共4页
N,N-Dimethylaniline hydroperoxide was obtained when treating N,N-dimethylaniline with NHPI/Co(OAc)2/O2 via a radical reaction mechanism. This intermediate has potential application in the synthesis of some important... N,N-Dimethylaniline hydroperoxide was obtained when treating N,N-dimethylaniline with NHPI/Co(OAc)2/O2 via a radical reaction mechanism. This intermediate has potential application in the synthesis of some important chemical scaffolds. 展开更多
关键词 Aerobic oxidation NHPI N n-dimethylaniline
下载PDF
Direct rapid determination of traces of sulfide in environment samples 被引量:1
2
作者 郭方遒 黄兰芳 梁逸曾 《Journal of Central South University of Technology》 2002年第4期250-254,共5页
An improved ethylene blue method for determination of sulfide is developed. It has been adapted to a direct determination of sulfide by both common spectrophotometric method and total differential spectrophotometric m... An improved ethylene blue method for determination of sulfide is developed. It has been adapted to a direct determination of sulfide by both common spectrophotometric method and total differential spectrophotometric method. In common spectrophotometric method, the calibration curve is A=1.69ρ + 0.006 and the correlation coefficient is 0.9994.The apparent molar absorptivity is 5.42×10 4 L·mol -1 ·cm -1 and calibration curve is liner when ρ is in the range of 0 0.9 mg·L -1 . In total differential spectrophotometric method, the calibration curve is A=9.25ρ +0.004 and the correlation coefficient is 0.9996. The apparent molar absorptivity is 2.96×10 5 L·mol -1 ·cm -1 and calibration curve is liner when ρ is in the range of 0 0.10 mg·L -1 . The sensitivity of this method is increased significantly compared with the former ethylene blue method. The speed of reaction is also faster than the former one. The limit of detection is found to be 1.0 ng·mL -1 by both common spectrophotometric method and total differential spectrophotometric method. Ten replicate analyses of a sample solution containing 100 ng·mL -1 sulfide give a relative standard deviation of 1.8%. The effects of various cations and anions on the determination of sulfide are studied and procedures for removal of interference is described. The method is used for the determination of sulfide in environment samples with satisfactory results. 展开更多
关键词 total differential SPECTROPHOTOMETRIC method p-amino-n N-diethylaniline K2Cr2O7 SULFIDE ENVIRONMENT SAMPLES
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部