期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Experimental study of the mass transfer behavior of carbon dioxide absorption into ternary phase change solution in a packed tower 被引量:2
1
作者 Yihan Yin Aoqian Qiu +2 位作者 Hongxia Gao Yanqing Na Zhiwu Liang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2022年第3期135-142,共8页
Phase change absorbents for CO_(2)are of great interest because they are expected to greatly reduce the heat energy consumption during the regeneration process.Compared with other phase change absorbents,monoethanolam... Phase change absorbents for CO_(2)are of great interest because they are expected to greatly reduce the heat energy consumption during the regeneration process.Compared with other phase change absorbents,monoethanolamine(MEA)-sulfolane-water is inexpensive and has a fast absorption rate.It is one of the most promising solvents for large-scale industrial applications.Therefore,this study investigates the mass transfer performance of this phase change system in the process of CO_(2)absorption in a packed tower.By comparing the phase change absorbent and the ordinary absorbent,it is concluded that the use of MEA/sulfolane phase change absorbent has significantly improved mass transfer efficiency compared to a single MEA absorbent at the same concentration.In the 4 mol·L^(-1)MEA/5 mol·L^(-1)sulfolane system,the CO_(2)loading of the upper liquid phase after phase separation is almost zero,while the volume of the lower liquid phase sent to the desorption operation is about half of the total volume of the absorbent,which greatly reduces the energy consumption.This study also investigates the influence of operating parameters such as lean CO_(2)loading,gas and liquid flow rates,CO_(2)partial pressure,and temperature on the volumetric mass transfer coefficient(K_(G)α_(V)).The research shows that K_(G)α_(V) increases with increasing liquid flow rate and decreases with the increase of lean CO_(2)loading and CO_(2)partial pressure,while the inert gas flow rate and temperature have little effect on K_(G)α_(V).In addition,based on the principle of phase change absorption,a predictive equation for the K_(G)α_(V) of MEA-sulfolane in the packed tower was established.The K_(G)α_(V) obtained from the experiment is consistent with the model prediction,and the absolute average deviation(AAD)is 7.8%. 展开更多
关键词 Monoethanolamine-sulfolane-water Phase change solution Mass transfer packed tower
下载PDF
Numerical Simulation of Air-cooling Tower 被引量:1
2
作者 Lijuan Hao Huanzhi Li Zhaohu Sun Lige TongThermal Energy Department, Beijing University of Science and Technology, Beijing 100083, China 《Journal of Thermal Science》 SCIE EI CAS CSCD 2003年第3期264-269,共6页
A mathematic model for packed air-cooling tower thermodynamic calculation is set up in this paper on the basis of fundamental heat and mass transfer equations. Based on the Double Film theory, direct equation-solving ... A mathematic model for packed air-cooling tower thermodynamic calculation is set up in this paper on the basis of fundamental heat and mass transfer equations. Based on the Double Film theory, direct equation-solving method is used to simulate air-cooling tower, and variation of parameters is taken to analyze the data and results of the program. 展开更多
关键词 packing air-cooling tower computer simulation mathematic model
原文传递
Experimental study of the flow and heat transfer of a gas–water mixture through a packed channel 被引量:1
3
作者 Xiaolei Zhu Xiaofeng Sui +2 位作者 Yan Zhao Ji'an Meng Zhixin Li 《Science Bulletin》 SCIE EI CAS CSCD 2016年第5期406-415,共10页
Waste heat recovery from the flue gas of gasfired boilers was studied experimentally by measuring the flow and heat transfer of air and water through six kinds of packing with saturated humid air as the simulated flue... Waste heat recovery from the flue gas of gasfired boilers was studied experimentally by measuring the flow and heat transfer of air and water through six kinds of packing with saturated humid air as the simulated flue gas.The experiments measured the effects of inlet air temperature, inlet air velocity and circulating water flow rate on the flow and heat transfer. The results show that higher inlet air temperatures and lower inlet air velocities lower the flow resistance and increase the heat transfer coefficient. The stainless steel packing had better surface wettability and larger thermal conductivity than the plastic packing, which enhanced the heat transfer between the water and the saturated moist air. When both the flow resistance reduction and the heat transfer enhancement were considered, the experimental results gave an optimal packing-specific surface area. A packed heat exchanger tower was designed for waste heat recovery from the flue gas of gas-fired boilers based on the experimental results which had better flow and heat transfer characteristics with lower pump and fan power consumption, more stable system operation and less thermal fluctuations compared with a non-packed heat transfer system with atomized water. 展开更多
关键词 Flue gas waste heat recovery Flow and heat transfer Moist air packed heat exchanger tower
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部