The accuracy and repeatability of computer aided cervical vertebra landmarking (CACVL) were investigated in cephalogram.120 adolescents (60 boys,60 girls) aged from 9.1 to 17.2 years old were randomly selected.Twenty-...The accuracy and repeatability of computer aided cervical vertebra landmarking (CACVL) were investigated in cephalogram.120 adolescents (60 boys,60 girls) aged from 9.1 to 17.2 years old were randomly selected.Twenty-seven landmarks from the second to fifth cervical vertebrae on the lat-eral cephalogram were identified.In this study,the system of CACVL was developed and used to iden-tify and calculate the landmarks by fast marching method and parabolic curve fitting.The accuracy and repeatability in CACVL group were compared with those in two manual landmarking groups [orthodon-tic experts (OE) group and orthodontic novices (ON) group].The results showed that,as for the accu-racy,there was no significant difference between CACVL group and OE group no matter in x-axis or y-axis (P>0.05),but there was significant difference between CACVL group and ON group,as well as OE group and ON group in both axes (P<0.05).As for the repeatability,CACVL group was more reli-able than OE group and ON group in both axes.It is concluded that CACVL has the same or higher ac-curacy,better repeatability and less workload than manual landmarking methods.It’s reliable for cervi-cal parameters identification on the lateral cephalogram and cervical vertebral maturation prediction in orthodontic practice and research.展开更多
Energy calibration of resistive charge division-based position-sensitive silicon detectors is achieved by parabolic fitting in the traditional method, where the systematic variations of vertex and curvature of the par...Energy calibration of resistive charge division-based position-sensitive silicon detectors is achieved by parabolic fitting in the traditional method, where the systematic variations of vertex and curvature of the parabola with energy must be considered. In this paper we extend the traditional method in order to correct the fitting function, simplify the procedure of calibration and improve the experimental data quality. Instead of a parabolic function as used in the traditional method, a new function describing the relation of position and energy is introduced.The energy resolution of the 8.088 Me V α decay of213 Rn is determined to be about 87 ke V(FWHM), which is better than the result of the traditional method, 104 ke V(FWHM). The improved method can be applied to the energy calibration of resistive charge division-based position-sensitive silicon detectors with various performances.展开更多
基金supported by grants from National Natural Sciences Foundation of China (No. 30801314)China Hubei Provincial Science and Technology Department (No.2008CBD088)
文摘The accuracy and repeatability of computer aided cervical vertebra landmarking (CACVL) were investigated in cephalogram.120 adolescents (60 boys,60 girls) aged from 9.1 to 17.2 years old were randomly selected.Twenty-seven landmarks from the second to fifth cervical vertebrae on the lat-eral cephalogram were identified.In this study,the system of CACVL was developed and used to iden-tify and calculate the landmarks by fast marching method and parabolic curve fitting.The accuracy and repeatability in CACVL group were compared with those in two manual landmarking groups [orthodon-tic experts (OE) group and orthodontic novices (ON) group].The results showed that,as for the accu-racy,there was no significant difference between CACVL group and OE group no matter in x-axis or y-axis (P>0.05),but there was significant difference between CACVL group and ON group,as well as OE group and ON group in both axes (P<0.05).As for the repeatability,CACVL group was more reli-able than OE group and ON group in both axes.It is concluded that CACVL has the same or higher ac-curacy,better repeatability and less workload than manual landmarking methods.It’s reliable for cervi-cal parameters identification on the lateral cephalogram and cervical vertebral maturation prediction in orthodontic practice and research.
基金Supported by ‘100 Person Project’ of the Chinese Academy of Sciencesthe National Natural Science Foundation of China(11405224 and 11435014)
文摘Energy calibration of resistive charge division-based position-sensitive silicon detectors is achieved by parabolic fitting in the traditional method, where the systematic variations of vertex and curvature of the parabola with energy must be considered. In this paper we extend the traditional method in order to correct the fitting function, simplify the procedure of calibration and improve the experimental data quality. Instead of a parabolic function as used in the traditional method, a new function describing the relation of position and energy is introduced.The energy resolution of the 8.088 Me V α decay of213 Rn is determined to be about 87 ke V(FWHM), which is better than the result of the traditional method, 104 ke V(FWHM). The improved method can be applied to the energy calibration of resistive charge division-based position-sensitive silicon detectors with various performances.