Accuracy and Repeatability of Computer Aided Cervical Vertebra Landmarking in Cephalogram 被引量:2
1
作者 陈莉莉 蓝智聪 +2 位作者 许向阳 林久祥 胡怀飞 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2012年第1期119-123,共5页
The accuracy and repeatability of computer aided cervical vertebra landmarking (CACVL) were investigated in cephalogram.120 adolescents (60 boys,60 girls) aged from 9.1 to 17.2 years old were randomly selected.Twenty-... The accuracy and repeatability of computer aided cervical vertebra landmarking (CACVL) were investigated in cephalogram.120 adolescents (60 boys,60 girls) aged from 9.1 to 17.2 years old were randomly selected.Twenty-seven landmarks from the second to fifth cervical vertebrae on the lat-eral cephalogram were identified.In this study,the system of CACVL was developed and used to iden-tify and calculate the landmarks by fast marching method and parabolic curve fitting.The accuracy and repeatability in CACVL group were compared with those in two manual landmarking groups [orthodon-tic experts (OE) group and orthodontic novices (ON) group].The results showed that,as for the accu-racy,there was no significant difference between CACVL group and OE group no matter in x-axis or y-axis (P>0.05),but there was significant difference between CACVL group and ON group,as well as OE group and ON group in both axes (P<0.05).As for the repeatability,CACVL group was more reli-able than OE group and ON group in both axes.It is concluded that CACVL has the same or higher ac-curacy,better repeatability and less workload than manual landmarking methods.It’s reliable for cervi-cal parameters identification on the lateral cephalogram and cervical vertebral maturation prediction in orthodontic practice and research. 展开更多
关键词 cervical vertebral maturation fast marching method parabolic curve fitting LANDMARK ac-curacy REPEATABILITY
下载PDF
An improved method of energy calibration for position-sensitive silicon detectors
2
作者 孙明道 黄天衡 +9 位作者 刘忠 丁兵 杨华彬 张志远 王建国 马龙 郁琳 王永生 甘再国 周小红 《Chinese Physics C》 SCIE CAS CSCD 2016年第4期93-97,共5页
Energy calibration of resistive charge division-based position-sensitive silicon detectors is achieved by parabolic fitting in the traditional method, where the systematic variations of vertex and curvature of the par... Energy calibration of resistive charge division-based position-sensitive silicon detectors is achieved by parabolic fitting in the traditional method, where the systematic variations of vertex and curvature of the parabola with energy must be considered. In this paper we extend the traditional method in order to correct the fitting function, simplify the procedure of calibration and improve the experimental data quality. Instead of a parabolic function as used in the traditional method, a new function describing the relation of position and energy is introduced.The energy resolution of the 8.088 Me V α decay of213 Rn is determined to be about 87 ke V(FWHM), which is better than the result of the traditional method, 104 ke V(FWHM). The improved method can be applied to the energy calibration of resistive charge division-based position-sensitive silicon detectors with various performances. 展开更多
关键词 calibration fitting simplify vertex curvature resistive correct parabolic describing implanted