An Analysis and Simulation of Failure in Dower Connectors 被引量:1
1
作者 LUO Guo ping directed by ZHANG Ji gao 《The Journal of China Universities of Posts and Telecommunications》 EI CSCD 2002年第3期79-80,共2页
Power connector, as one kind of fittings, is used to connect power equipmentto conductor, conductor to wire or wire to wire in power lines. Owing to its simple structure, easyinstallation and low cost, bolt-type power... Power connector, as one kind of fittings, is used to connect power equipmentto conductor, conductor to wire or wire to wire in power lines. Owing to its simple structure, easyinstallation and low cost, bolt-type power connector-parallel groove clamp is widely used inoverhead power transmission and distribution line. However, owing to high current load and harshenvironment in China, there are still some problems in application of this kind of connector. So,some failure connectors replaced from domestic overhead power lines are collected. The main reasonsthe failure are given out through investigation into residual contact force, connection resistance,substrate quality, makeup, condition of contact interface and installation, manufacture techniqueetc. Then, the current test on parallel groove clamps is carried out and finite element method isused to simulate its failure process. 展开更多
关键词 power connector analysis of failure parallel groove clump finite element simulation