Failure Analysis and Design Changes of Oxygen Pump Inducers
1
作者 梁恒力 陈佐一 《Tsinghua Science and Technology》 SCIE EI CAS 2001年第5期492-496,共5页
The failure of an oxygen pump inducer during a test run was found to be the result of flow induced vibration. Oscillating fluid mechanics theory was used to determine the oscillating flow field around the inducer fo... The failure of an oxygen pump inducer during a test run was found to be the result of flow induced vibration. Oscillating fluid mechanics theory was used to determine the oscillating flow field around the inducer for various external oscillating perturbation frequencies. Enormous pressures can occur at some frequencies, which are sufficient to break the inducer. Some design changes were analyzed to improve the flow induced vibration characteristics. 展开更多
关键词 INDUCER flow induced vibration paremetric polynomial method (ppm) numerical calculation