Development of Laser-Based Handheld Aerosol Particle Counter
1
作者 陈畅 李辉 《Journal of Electronic Science and Technology of China》 2005年第4期357-359,共3页
The JC-CA300 handheld Aerosol particle counter is designed and developed based on light scattering principle. The JC-CA300 counter is composed of optical sensor, DSP component and microprocessor unit. The hardware arc... The JC-CA300 handheld Aerosol particle counter is designed and developed based on light scattering principle. The JC-CA300 counter is composed of optical sensor, DSP component and microprocessor unit. The hardware architecture is designed in compact style by SMT IC chips. The whole counter weight is less than 2 pounds. With 32K RAM space, the JC-CA300 can store 500 sampling records and support standard printer and communicate with a computer through RS232 interface. Based on experimental results, the main performance of JC-CA300 is better than that of the ARTI'S HHPC-6 instrument. 展开更多
关键词 particle counter light scattering digital signal processing
下载PDF
A model for aerosol mass concentration using an optical particle counter 被引量:11
2
作者 顾芳 杨娟 +1 位作者 保民 贺安之 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第3期214-217,共4页
A model for measuring aerosol mass concentration by an optical particle counter is presented using the conception of the average mass. In this model, to understand the meaning of the pulse height distribution of parti... A model for measuring aerosol mass concentration by an optical particle counter is presented using the conception of the average mass. In this model, to understand the meaning of the pulse height distribution of particles which is used to inverse mass concentration, the relationship among intensity distribution in the optical sensing volume, particle shape, and the pulse height distribution is discussed. To solve the instability of the equivalent factor, a novel two-step calibration method is proposed. The experimental results demonstrate that mass concentrations calculated by the model are in good agreement with those measured by a norm-referenced instrument. For samples of soot and air, the slopes of fitting lines of data points are 0.9582 and 0.9220, and the correlation coefficients are 0.9991 and 0.9965, respectively. 展开更多
关键词 A model for aerosol mass concentration using an optical particle counter OPC
原文传递
Impact of dynamic distribution of floc particles on flocculation effect 被引量:4
3
作者 NAN Jun, HE Weipeng, SONG Xinin, LI Guibai State Key Laboratory of Urban Water Resource and Environment, School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090, China. 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2009年第8期1059-1065,共7页
Polyaluminum chloride (PAC) was used as coagulant and suspended particles in kaolin water. Online instruments including turbidimeter and particle counter were used to monitor the flocculation process. An evaluation ... Polyaluminum chloride (PAC) was used as coagulant and suspended particles in kaolin water. Online instruments including turbidimeter and particle counter were used to monitor the flocculation process. An evaluation model for demonstrating the impact on the flocculation effect was established based on the multiple linear regression analysis method. The parameter of the index weight of channels quantitatively described how the variation of floc particle population in different size ranges cause the decrement of turbidity. The study showed that the floc particles in different size ranges contributed differently to the decrease of turbidity and that the index weight of channel could excellently indicate the impact degree of floc particles dynamic distribution on flocculation effect. Therefore, the parameter may significantly benefit the development of coagulation and sedimentation techniques as well as the optimal coagulant selection. 展开更多
关键词 particle size distribution particle counter index weight flocculation process
下载PDF
Light scattering:A review of particle characterization applications 被引量:15
4
作者 Renliang Xu 《Particuology》 SCIE EI CAS CSCD 2015年第1期11-21,共11页
This review covers the progress of light scattering applications in the field of particle characterization in the past decade. The review addresses static light scattering (the measurement of scattering intensities d... This review covers the progress of light scattering applications in the field of particle characterization in the past decade. The review addresses static light scattering (the measurement of scattering intensities due to light-particle interaction at various spatial locations), dynamic light scattering (the measurement of scattering due to light-particle interaction as a function of time), and scattering tracking analysis (the tracking of particle movement through scattering measurement). 展开更多
关键词 Dynamic light scattering particle tracking analysis Electrophoretic light scattering Laser diffraction particle counter Self-mixing laser spectroscopy
原文传递
Fractal Characteristics of Particle Size Distribution in Dynamic Flocculation Process 被引量:4
5
作者 NAN Jun, HE Weipeng, ZHANG Zhijun, LI Guibai State Key Laboratory of Urban Water Resource and Environment/School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090, Heilongjiang, China 《Wuhan University Journal of Natural Sciences》 CAS 2009年第6期511-517,共7页
This study selected polyaluminum chloride(PAC) coagulant to remove suspended particles in Kaolin suspension solution and used a turbidimeter and particle counter to monitor the flocculation process online and collec... This study selected polyaluminum chloride(PAC) coagulant to remove suspended particles in Kaolin suspension solution and used a turbidimeter and particle counter to monitor the flocculation process online and collected the experiment data. The experiments were conducted to study the dynamic distribution characteristics of suspended particles under different hydrodynamic conditions. The results show the self-similarity and scale invariance of particle size distribution. The study further proposed the concept of fractal dimension of particle size distribution and found out that fractal dimension changed in a similar way as residual turbidity did and could excellently indicate the variation of coagulation effect. Therefore, fractal dimension could be adopted to optimize the addition of coagulants and the quality of outflow could be further improved to reduce production costs. 展开更多
关键词 FLOCCULATION particle size distribution fractal dimension particle counter
原文传递
Determining the relationship between chemical composition and size, shape and effective density of airborne fine particles through concurrent use of inertial and optical based measurements 被引量:1
6
作者 Anand Kumar Tarun Gupta 《Particuology》 SCIE EI CAS CSCD 2016年第5期93-101,共9页
This study presents the development of a medium flow, multiple slit based PM2.5 (particle aerodynamic diameter 〈2.5 μm) inertial impactor. Its performance was compared with that of a light scattering based optical... This study presents the development of a medium flow, multiple slit based PM2.5 (particle aerodynamic diameter 〈2.5 μm) inertial impactor. Its performance was compared with that of a light scattering based optical particle sizer in a field study and in controlled lab based experiments using polydisperse dolomite powder as test aerosol. The impactor's optimum nozzle configuration had a cutoff size of 2.51 μm (aero- dynamic diameter) at an operating flow rate of 215 L/rain with a pressure drop of 0.35 kPa across the impactor stage. Because the apparent particle density of an ambient aerosol depends on the physical properties and the chemical composition of the particles, the PM2.5 mass concentration was measured with an optical particle sizer and an inertial impactor over a weekday and a weekend day in a field study during which the effective particle shape factor and density were in tandem modified in order to com- pare the results from the two sampling techniques. The correlation of the two instrument results tended towards 1:1 with increasing values of shape factor (irregular shaped) and effective particle density. This observation was supported through chemical investigations of the collected mass, which showed a higher percentage contribution from elements which are mostly of crustal nature (namely, Ca, Fe, and Mg). 展开更多
关键词 lmpactor PM2.5 Optical particle counter Effective particle density Shape factor
原文传递
ANALYSIS OF PARTICULATE MASS CONCENTRATION,AEROSOL NUMBER CONCENTRATION AND VISIBILITY IN BEIJING 被引量:7
7
作者 FengqiYan HuanlingHu TongYu 《China Particuology》 SCIE EI CAS CSCD 2004年第1期25-30,共6页
Particulate mass concentration (PM10, PM2.5), aerosol number concentration (NOPC), aerosol size distribu-tion and atmospheric visibility were simultaneously measured in Beijing in the summer and winter of 2001. From t... Particulate mass concentration (PM10, PM2.5), aerosol number concentration (NOPC), aerosol size distribu-tion and atmospheric visibility were simultaneously measured in Beijing in the summer and winter of 2001. From the profuse data collected, the following conclusions can be drown: (1) there are two peaks for the average diurnal variations of PM10 and NOPC in the summer, an obvious valley can be seen between 12:30 and 15:00 for their average diurnal variation in the winter; (2) there is one single peak for the average diurnal variation of atmospheric visibility in the summer, while there are two peaks in the winter; (3) PM10 and NOPC are usually smaller in the summer than those in the winter; (4) the average visibility is much lower during 00:00~09:00 in the summer than that in the winter, because of the very high relative humidity and higher concentration of the large particles (r>1.25 mm) in the summer during the period; (5) aerosol size distributions usually depend closely on season and relative humidity at the same place. 展开更多
关键词 optical particle counter atmospheric aerosol atmospheric visibility number concentration DISTRIBUTION
原文传递