With the rapid development of the wind generation,uncertainties of random wind and load bring some inevitable impacts on the security of power system. Once the uncertainty causes line power to exceed its limit, line o...With the rapid development of the wind generation,uncertainties of random wind and load bring some inevitable impacts on the security of power system. Once the uncertainty causes line power to exceed its limit, line overload will occur. The paper presents the risk control of transmission line overload for windintegrated power systems. Firstly, a risk control model of line overload is proposed considering the uncertainties of loads,generator outputs and wind powers. The generation cost and security level of system associated with overload can be optimally controlled. Then path following interior point method is employed to carry out the optimal control. Finally the simulation is made on the modified IEEE-30 bus system. Results show that the risk of line overload is effectively reduced through the optimization of control variables.展开更多
Nonlinear solution of reinforced concrete structures, particularly complete load-deflection response, requires tracing of the equilibrium path and proper treatment of the limit and bifurcation points. In this regard, ...Nonlinear solution of reinforced concrete structures, particularly complete load-deflection response, requires tracing of the equilibrium path and proper treatment of the limit and bifurcation points. In this regard, ordinary solution techniques lead to instability near the limit points and also have problems in case of snap-through and snap-back. Thus they fail to predict the complete load-displacement response. The arc-length method serves the purpose well in principle, received wide acceptance in finite element analysis, and has been used extensively. However modifications to the basic idea are vital to meet the particular needs of the analysis. This paper reviews some of the recent developments of the method in the last two decades, with particular emphasis on nonlinear finite element analysis of reinforced concrete structures.展开更多
基金National Natural Science Foundations of China(Nos.51007052,71201097)Natural Science Foundation of Shanghai,China(No.14ZR1415300)
文摘With the rapid development of the wind generation,uncertainties of random wind and load bring some inevitable impacts on the security of power system. Once the uncertainty causes line power to exceed its limit, line overload will occur. The paper presents the risk control of transmission line overload for windintegrated power systems. Firstly, a risk control model of line overload is proposed considering the uncertainties of loads,generator outputs and wind powers. The generation cost and security level of system associated with overload can be optimally controlled. Then path following interior point method is employed to carry out the optimal control. Finally the simulation is made on the modified IEEE-30 bus system. Results show that the risk of line overload is effectively reduced through the optimization of control variables.
文摘Nonlinear solution of reinforced concrete structures, particularly complete load-deflection response, requires tracing of the equilibrium path and proper treatment of the limit and bifurcation points. In this regard, ordinary solution techniques lead to instability near the limit points and also have problems in case of snap-through and snap-back. Thus they fail to predict the complete load-displacement response. The arc-length method serves the purpose well in principle, received wide acceptance in finite element analysis, and has been used extensively. However modifications to the basic idea are vital to meet the particular needs of the analysis. This paper reviews some of the recent developments of the method in the last two decades, with particular emphasis on nonlinear finite element analysis of reinforced concrete structures.