期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Direct Analytical Method to Calculate Photopeak Efficiency and Photopeak Attenuation Coefficient of NaI(Tl) Well-Type Detector
1
作者 K. S. Al-Mugren Mahmoud I. Abbas +1 位作者 Eman M. El-Bayoumi N. S. Aly 《World Journal of Nuclear Science and Technology》 2016年第2期115-124,共10页
In this paper full-energy peak (photopeak) efficiency and photopeak attenuation coefficient of 3'' × 3'' NaI(Tl) well-type scintillation detector were calculated using gamma-rayisotropic radiating... In this paper full-energy peak (photopeak) efficiency and photopeak attenuation coefficient of 3'' × 3'' NaI(Tl) well-type scintillation detector were calculated using gamma-rayisotropic radiating point sources (with photon energy: 0.245, 0.344, 0.662, 0.779, 0.964, 1.1732, 1.333 and 1.408 MeV) placed outside the detector well. These energies were obtained from <sup>152</sup>Eu, <sup>137</sup>Cs and <sup>60</sup>Co. The relations between the full energy peak efficiency and photopeak attenuation coefficients, were plotted vs. photon energy at different sources to detector distance, and it found that the full energy peak efficiency decreased by increasing the distance between the source and the detector. 展开更多
关键词 NaI(Tl) Well-Type Scintillation Detector Full-Energy peak efficiency Photopeak Attenuation Coefficient Gamma-Ray Point Sources
下载PDF
Verification of modified sum-peak method in Monte Carlo simulation of full energy peak and sum-peak efficiencies of a HPGe detector 被引量:1
2
作者 Tsukasa Aso Yoshimune Ogata Hidesuke Itadzu 《辐射防护》 CAS CSCD 北大核心 2020年第6期527-532,共6页
The modified sum-peak method estimates radioactivity by using only the peak and the sum-peak count rates.To verify the modified sum-peak method,the dependence of the full energy peak efficiency on the source-to-detect... The modified sum-peak method estimates radioactivity by using only the peak and the sum-peak count rates.To verify the modified sum-peak method,the dependence of the full energy peak efficiency on the source-to-detector distance in a high-purity germanium detector system was studied using a Geant4 Monte Carlo simulation.The effect of the deadlayer in the germanium crystal was estimated by reference to experiments on 241 Am and the relative efficiency of the detector.The peak efficiency dependence on the source-to-detector distance was compared between the simulation and measurements.The modified sum-peak method is discussed with respect to these peak efficiencies. 展开更多
关键词 Geant4 Monte Carlo simulation sum-peak method peak efficiency HPGE 60Co
下载PDF
Gamma Spectrometry of Inhomogeneous Samples Using Peak-Ratio Method
3
作者 Thomas M. Semkow Liang T. Chu Adam G. Burn 《Journal of Applied Mathematics and Physics》 2021年第11期2641-2659,共19页
In gamma spectrometry of voluminous samples, inhomogeneous distribution of radioactivity caused by the presence of hot particles can create significant Bias in the results of activity determinations. We developed a no... In gamma spectrometry of voluminous samples, inhomogeneous distribution of radioactivity caused by the presence of hot particles can create significant Bias in the results of activity determinations. We developed a novel method to reduce this Bias using the gamma-peak ratio. We show that the peak area ratio of two gamma peaks of different energies, emitted by the same radionuclide, is a sensitive measure of emitting source location and thus the inhomogeneity. A new calibration formula was then derived for true gamma efficiency <em>p<sub>i</sub></em> as a function of efficiency ratio <em>p<sub>i</sub></em>/<em>p<sub>j</sub></em> of two peaks. This approach was verified by Monte Carlo simulations for a sample of 1-L volume containing from 1 up to 2048 of hot particles randomly distributed in a soil matrix. A <sup>152</sup>Eu radionuclide was selected for calculations and we used various combinations of two gamma spectral peaks selected from three gamma energies of 121.8, 344.3, and 1408.0 keV. This new method is shown to reduce the Bias range and Bias standard deviation by several times when compared with the traditional homogeneous calibration applied to measuring hot particles. The method is independent of the number, location, and distribution of hot particles in the samples, and can be applied to a mixture of radionuclides. It complements our previous calibration model based on the peak-to-total ratio. 展开更多
关键词 Monte Carlo Simulation Gamma Attenuation Hot Particle Effective peak efficiency Signal Detection Theory
下载PDF
Monte Carlo Simulation Study of Hot-Particle Detection in Voluminous Samples by Gamma Spectrometry 被引量:1
4
作者 Liang T. Chu Adam G. Burn +1 位作者 Clayton J. Bradt Thomas M. Semkow 《Journal of Applied Mathematics and Physics》 2021年第7期1522-1540,共19页
In this work, we addressed the inhomogeneity problem in gamma spectrometry caused by hot particles, which are dispersed into environment from large nuclear reactor accidents such as at Chernobyl and Fukushima. Using M... In this work, we addressed the inhomogeneity problem in gamma spectrometry caused by hot particles, which are dispersed into environment from large nuclear reactor accidents such as at Chernobyl and Fukushima. Using Monte Carlo simulation, we have determined the response of a gamma spectrometer to individual and grouped hot particles randomly distributed in a soil matrix of 1-L and 0.6-L sample containers. By exploring the fact that the peak-to-total ratio of efficiencies in gamma spectrometry is an empirical parameter, we derived and verified a power-law relationship between the peak efficiency and peak-to-total ratio. This enabled creation of a novel calibration model which was demonstrated to reduce the bias range and bias standard deviation, caused by measuring hot particles, by several times, as compared with the homogeneous calibration. The new model is independent of the number, location, and distribution of hot particles in the samples. In this work, we demonstrated successful performance of the model for a single-peak <sup>137</sup>Cs radionuclide. An extension to multi-peak radionuclide was also derived. 展开更多
关键词 CHERNOBYL FUKUSHIMA peak efficiency Total efficiency Signal Detection Theory
下载PDF
Stability management of high speed axial flow compressor stage through axial extensions of bend skewed casing treatment 被引量:3
5
作者 Dilipkumar Bhanudasji Alone S.Satish Kumar +4 位作者 Shobhavathy M.Thimmaiah Janaki Rami Reddy Mudipalli A.M.Pradeep Srinivasan Ramamurthy Venkat S.Iyengara 《Propulsion and Power Research》 SCIE 2016年第3期236-249,共14页
This paper presents the experimental results to understand the performance of moderately loaded high speed single stage transonic axial flow compressor subjected to various configurations of axial extensions of bend s... This paper presents the experimental results to understand the performance of moderately loaded high speed single stage transonic axial flow compressor subjected to various configurations of axial extensions of bend skewed casing treatment with moderate porosity.The bend skewed casing treatment of 33%porosity was coupled with rectangular plenum chamber of depth equal to the slots depth.The five axial extensions of 20%,40%,60%,80%and 100%were used for the experimental evaluations of compressor performance.The main objective was to identify the optimum extension of the casing treatment with reference to rotor leading edge which results in maximum stall margin improvements with minimum loss in the stage efficiency.At each axial extension the compressor performance is distinctive.The improvement in the stall margin was very significant at some axial extensions with 4%–5%penalty in the stage efficiency.The compressors stage shows recovery in terms of efficiency at lower axial extensions of 20%and 40%with increase in the peak stage efficiency.Measurements of flow parameters showed the typical behaviors at near stall flow conditions.Hot wire sensor was placed at the rotor upstream in the tip region to capture the oscillations in the inlet axial and tangential velocities at stall conditions.In the absence of casing treatment the compressor exhibit abrupt stall with very high oscillations in the inlet axial and tangential velocity of the flow.The extents of oscillations reduce with bend skewed casing treatment.Few measurements were also performed in the plenum chamber and salient results are presented in this paper. 展开更多
关键词 High speed compressor Bend skewed casing treatments Axial extensions Stall margin improvements peak stage efficiency Hot wire probe STALL ABRUPT
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部