In this paper, a design method for ocean wave permanent magnet synchronous generator(PMSG)is proposed with new performance criteria to obtain better output performance at the cost of less permanent magnet material. Be...In this paper, a design method for ocean wave permanent magnet synchronous generator(PMSG)is proposed with new performance criteria to obtain better output performance at the cost of less permanent magnet material. Besides, a simple equivalent analytical geometry method is put forward to calculate the sizes of permanent magnets. Based on geometric and electromagnetic models, four types of rotor structures are compared, i.e., embedded, tangential, tile surface mount and convex surface mount structures. The designs and comparisons of machine are performed with the same permanent magnet volume. Moreover, the influences of mechanical pole-arc coefficient of tile surface mount PMSG on electrical efficiency, output power, material corrosion, core loss, and torque ripple are investigated. Finite-element analysis method is applied to verify the results using Ansoft/Maxwell.展开更多
We present a sensorless efficiency test system with energy recovery for a high-speed permanent magnet synchronous motor(PMSM). In the system, two identical high-speed PMSMs are used as the motor under test(MUT)and the...We present a sensorless efficiency test system with energy recovery for a high-speed permanent magnet synchronous motor(PMSM). In the system, two identical high-speed PMSMs are used as the motor under test(MUT)and the load machine(LM),respectively.A new sensorless vector control(VC) method based on a hypothetical reference frame is presented to control both the MUT and the LM.Also,a regenerating unit is used to implement energy circulation to save energy.Experiments were carried out on a prototype, with a digital controller based on the TMS320 F28335, to verify the adequacy of the sensorless VC method.As a result,the efficiency test system achieves the load test at the speed of 21000 r/min without any reduction equipment. During the test, the energy regenerated by the LM could be fed back to the MUT by the regenerating unit, and 81.31% electrical power was saved.In addition, with the proposed sensorless VC method,both the MUT and the LM can work at i_d = 0 without a position sensor.展开更多
Making full use of wind power is one of the main purposes of the wind turbine generator control. Conventional hill climbing search (HCS) method can realize the maximum power point tracking (MPPT). However, the ste...Making full use of wind power is one of the main purposes of the wind turbine generator control. Conventional hill climbing search (HCS) method can realize the maximum power point tracking (MPPT). However, the step size of HCS method is constant so that it cannot consider both steady-state response and dynamic response. A fuzzy logical control (FLC) algorithm is proposed to solve this problem in this paper, which can track the maximum power point (MPP) quickly and smoothly. To evaluate MPPT algorithms, four performance indices are also proposed in this paper. They are the energy captured by wind turbine, the maximum power-point tracking time when wind speed changes slowly, the fluctuation magnitude of real power during steady state, and the energy captured by wind turbine when wind speed changes fast. Three cases are designed and simulated in MATLAB/Simulink respectively. The comparison of the three MPPT strategies concludes that the proposed fuzzy logical control algorithm is more superior to the conventional HCS algorithms.展开更多
This paper proposes a residue theorem based soft sliding mode control strategy for a permanent magnet synchronous generator(PMSG)based wind power generation system(WPGS),to achieve the maximum energy conversion and im...This paper proposes a residue theorem based soft sliding mode control strategy for a permanent magnet synchronous generator(PMSG)based wind power generation system(WPGS),to achieve the maximum energy conversion and improved in the system dynamic performance.The main idea is to set a soft dynamic boundary for the controlled variables around a reference point.Thus the controlled variables would lie on a point inside the boundary.The convergence of the operating point is ensured by following the Forward Euler method.The proposed control has been verified via simulation and experiments,compared with conventional sliding mode control(SMC)and proportional integral(PI)control.展开更多
基金Supported by the National Natural Science Foundation of China(No.51577124)Tianjin Research Program of Application Foundation and Advanced Technology(No.15JCZDJC32100)
文摘In this paper, a design method for ocean wave permanent magnet synchronous generator(PMSG)is proposed with new performance criteria to obtain better output performance at the cost of less permanent magnet material. Besides, a simple equivalent analytical geometry method is put forward to calculate the sizes of permanent magnets. Based on geometric and electromagnetic models, four types of rotor structures are compared, i.e., embedded, tangential, tile surface mount and convex surface mount structures. The designs and comparisons of machine are performed with the same permanent magnet volume. Moreover, the influences of mechanical pole-arc coefficient of tile surface mount PMSG on electrical efficiency, output power, material corrosion, core loss, and torque ripple are investigated. Finite-element analysis method is applied to verify the results using Ansoft/Maxwell.
基金supported by the Science and Technology Project of State Grid Corporation, ‘‘Research on Key Technologies of Flexible Control Strategy for Variable Speed Pumped Storage Units’’the Fundamental Research Funds for the Central Universities (No. B18020574)
文摘We present a sensorless efficiency test system with energy recovery for a high-speed permanent magnet synchronous motor(PMSM). In the system, two identical high-speed PMSMs are used as the motor under test(MUT)and the load machine(LM),respectively.A new sensorless vector control(VC) method based on a hypothetical reference frame is presented to control both the MUT and the LM.Also,a regenerating unit is used to implement energy circulation to save energy.Experiments were carried out on a prototype, with a digital controller based on the TMS320 F28335, to verify the adequacy of the sensorless VC method.As a result,the efficiency test system achieves the load test at the speed of 21000 r/min without any reduction equipment. During the test, the energy regenerated by the LM could be fed back to the MUT by the regenerating unit, and 81.31% electrical power was saved.In addition, with the proposed sensorless VC method,both the MUT and the LM can work at i_d = 0 without a position sensor.
基金supported by the National High Technology Research and Development Program of China under Grant No.2011AA05S113Major State Basic Research Development Program under Grant No.2012CB215106+1 种基金Science and Technology Plan Program in Zhejiang Province under Grant No.2009C34013National Science and Technology Supporting Plan Project under Grant No.2009BAG12A09
文摘Making full use of wind power is one of the main purposes of the wind turbine generator control. Conventional hill climbing search (HCS) method can realize the maximum power point tracking (MPPT). However, the step size of HCS method is constant so that it cannot consider both steady-state response and dynamic response. A fuzzy logical control (FLC) algorithm is proposed to solve this problem in this paper, which can track the maximum power point (MPP) quickly and smoothly. To evaluate MPPT algorithms, four performance indices are also proposed in this paper. They are the energy captured by wind turbine, the maximum power-point tracking time when wind speed changes slowly, the fluctuation magnitude of real power during steady state, and the energy captured by wind turbine when wind speed changes fast. Three cases are designed and simulated in MATLAB/Simulink respectively. The comparison of the three MPPT strategies concludes that the proposed fuzzy logical control algorithm is more superior to the conventional HCS algorithms.
基金This study has been funded by the Royal Commission for Jubail and Yanbu,Saudi Arabia and the University of Liverpool,UK.
文摘This paper proposes a residue theorem based soft sliding mode control strategy for a permanent magnet synchronous generator(PMSG)based wind power generation system(WPGS),to achieve the maximum energy conversion and improved in the system dynamic performance.The main idea is to set a soft dynamic boundary for the controlled variables around a reference point.Thus the controlled variables would lie on a point inside the boundary.The convergence of the operating point is ensured by following the Forward Euler method.The proposed control has been verified via simulation and experiments,compared with conventional sliding mode control(SMC)and proportional integral(PI)control.