The present study was carried out in order to track the maximum power point in a variable speed turbine by minimizing electromechanical torque changes using a sliding mode control strategy. In this strategy, first, th...The present study was carried out in order to track the maximum power point in a variable speed turbine by minimizing electromechanical torque changes using a sliding mode control strategy. In this strategy, first, the rotor speed is set at an optimal point for different wind speeds. As a result of which, the tip speed ratio reaches an optimal point, mechanical power coefficient is maximized, and wind turbine produces its maximum power and mechanical torque. Then, the maximum mechanical torque is tracked using electromechanical torque. In this technique, tracking error integral of maximum mechanical torque, the error, and the derivative of error are used as state variables. During changes in wind speed, sliding mode control is designed to absorb the maximum energy from the wind and minimize the response time of maximum power point tracking(MPPT). In this method, the actual control input signal is formed from a second order integral operation of the original sliding mode control input signal. The result of the second order integral in this model includes control signal integrity, full chattering attenuation, and prevention from large fluctuations in the power generator output. The simulation results, calculated by using MATLAB/m-file software, have shown the effectiveness of the proposed control strategy for wind energy systems based on the permanent magnet synchronous generator(PMSG).展开更多
This paper studied the direct-drive permanent magnet synchronous machine (permanent magnet synchronous generator, PMSG) Chopper optimal topology and resistance value. Compared the different Chopper circuit low voltage...This paper studied the direct-drive permanent magnet synchronous machine (permanent magnet synchronous generator, PMSG) Chopper optimal topology and resistance value. Compared the different Chopper circuit low voltage ride-through capability in the same grid fault conditions in simulation. This paper computes the dump resistance ceiling according to the power electronic devices and over-current capability. Obtaining the dump resistance low limit according to the temperature resistance allows, and calculating the optimal value by drop voltage in the DC-Bus during the fault. The feasibility of the proposed algorithm is verified by simulation results.展开更多
The high-speed simulation of large-scale offshore wind farms(OWFs) preserving the internal machine information has become a huge challenge due to the large wind turbine(WT) count and microsecond-range time step. Hence...The high-speed simulation of large-scale offshore wind farms(OWFs) preserving the internal machine information has become a huge challenge due to the large wind turbine(WT) count and microsecond-range time step. Hence, it is undoable to investigate the internal node information of the OWF in the electro-magnetic transient(EMT) programs. To fill this gap,this paper presents an equivalent modeling method for largescale OWF, whose accuracy and efficiency are guaranteed by integrating the individual devices of permanent magnet synchronous generator(PMSG) based WT. The node-elimination algorithm is used while the internal machine information is recursively updated. Unlike the existing aggregation methods, the developed EMT model can reflect the characteristics of each WT under different wind speeds and WT parameters without modifying the codes. The access to each WT controller is preserved so that the time-varying dynamics of all the WTs could be simulated. Comparisons of the proposed model with the detailed model in PSCAD/EMTDC have shown very high precision and high efficiency. The proposed modeling procedures can be used as reference for other types of WTs once the structures and parameters are given.展开更多
A wind energy conversion system(WECS)based on a permanent magnet synchronous generator(PMSG)is an effective solution for renewable energy generation in modern power systems.The main advantages of PMSG include high per...A wind energy conversion system(WECS)based on a permanent magnet synchronous generator(PMSG)is an effective solution for renewable energy generation in modern power systems.The main advantages of PMSG include high performance at high and low speeds,minimal control effort owing to lower rotor inertia,self-excitation,high reliability,and simplicity of structure compared with induction generators.However,the intermittent nature of wind energy implies that maximum efficiency is not obtained from this system.Accordingly,maximum power point tracking(MPPT)in wind turbine systems has been proposed to address this problem.Traditional MPPT strategies suffer from severe output power fluctuations,low efficiency,and significant ripples in turbine rotation speed.This paper presents a novel MPPT control strategy based on fuzzy logic control(FLC)and model predictive control(MPC)to extract the maximum power from a PMSG-WECS and control the machine-side and grid-side converters.The simulation results obtained from Matlab/Simulink confirm the superiority of the control model in eliminating the output power fluctuations of the wind generators and accurately tracking the maximum power point.A comparative study between conventional MPPT and control methods is also conducted.展开更多
In a permanent magnet synchronous generator(PMSG)system,conversion systems are major points of failure that create expensive and time-consuming problems.Fault detection is usually used to achieve a steady system.This ...In a permanent magnet synchronous generator(PMSG)system,conversion systems are major points of failure that create expensive and time-consuming problems.Fault detection is usually used to achieve a steady system.This paper presents a full analysis of a PMSG system for wind turbines(WT)and proposes a fault detection method using correlation features.The proposed method is motivated by the balance among the three-phase currents both before and after an opencircuit fault occurs in a converter of the PMSG system.It is unnecessary to analyze the output waveforms of a converter during fault detection.In this study,two correlation features of stator currents,the mean and covariation,are extracted to train an artificial neural network(ANN),thereby enhancing the performance of the proposed method under different wind speed conditions.Moreover,additional sensors and the collection of a massive amount of data are not required.Model simulations of an ideal inverter and a PMSG system are conducted using PSCAD software.The simulation results show that the proposed method can detect the locations of faulty switches with a diagnostic rate greater than 99.4%for the ideal inverter,and the PMSG drives settings at different wind speeds.展开更多
This paper investigates a variable speed wind turbine based on permanent magnet synchronous generator and a full-scale power converter in a stand-alone system.An energy storage system(ESS)including battery and fuel ce...This paper investigates a variable speed wind turbine based on permanent magnet synchronous generator and a full-scale power converter in a stand-alone system.An energy storage system(ESS)including battery and fuel cell-electrolyzer combination is connected to the DC link of the full-scale power converter through the power electronics interface.Wind is the primary power source of the system,the battery and FC-electrolyzer combination is used as a backup and a long-term storage system to provide or absorb power in the stand-alone system,respectively.In this paper,a control strategy is proposed for the operation of this variable speed wind turbine in a stand-alone system,where the generator-side converter and the ESS operate together to meet the demand of the loads.This control strategy is competent for supporting the variation of the loads or wind speed and limiting the DC-link voltage of the full-scale power converter in a small range.A simulation model of a variable speed wind turbine in a stand-alone system is developed using the simulation tool of PSCAD/EMTDC.The dynamic performance of the stand-alone wind turbine system and the proposed control strategy is assessed and emphasized with the simulation results.展开更多
随着高压直流输电工程的不断投产,以及风电项目的增多,越来越多的风电场出现在电网换相换流器高压直流输电(line-commutated-converter based high voltage direct current,LCC-HVDC)受端换流站近区,两者构成的系统存在振荡风险。为此,...随着高压直流输电工程的不断投产,以及风电项目的增多,越来越多的风电场出现在电网换相换流器高压直流输电(line-commutated-converter based high voltage direct current,LCC-HVDC)受端换流站近区,两者构成的系统存在振荡风险。为此,该文针对直流受端馈入站与近区风电场系统的振荡特性展开研究。首先,建立并验证系统的状态空间模型,基于该模型计算出系统特征值,确定LCC-HVDC与风电场共同参与的振荡主导模式并进行参与因子分析。进一步地,通过对比是否接入LCC-HVDC的主导模式,得到LCC-HVDC的接入会削弱系统阻尼的结论。最后,从系统额定容量、交流系统短路比、风电场并网线路长度等方面探究系统稳定性的影响因素,并分析系统的不同短路比、潮流比对风机网侧换流器(grid-side converter,GSC)外环控制和换流站定电流控制器性能的影响。展开更多
文中提出将新型的三相Z源逆变器应用于永磁同步发电机PMSG(permanent magnet synchronous generator)风力并网发电系统中,分析了此系统下的风能最大功率点跟踪MPPT(maximum power point tracking)原理。阐明了三相Z源逆变器直通占空比...文中提出将新型的三相Z源逆变器应用于永磁同步发电机PMSG(permanent magnet synchronous generator)风力并网发电系统中,分析了此系统下的风能最大功率点跟踪MPPT(maximum power point tracking)原理。阐明了三相Z源逆变器直通占空比和发电机输出转速之间的关系,并设计了基于最大功率曲线的MPPT算法。该算法可省去风速和转速的测量,降低了系统的成本。利用计算机仿真绘图说明了系统做MPPT的工作点调节过程。最后的实验证实了理论分析和算法的正确法。展开更多
当直驱风机(direct-drive permanent magnet synchronous generator,D-PMSG)位于电网换相换流器高压直流输电(line-commutated-converter based high voltage direct current,LCC-HVDC)整流站近区时,系统的次同步振荡(subsynchronous os...当直驱风机(direct-drive permanent magnet synchronous generator,D-PMSG)位于电网换相换流器高压直流输电(line-commutated-converter based high voltage direct current,LCC-HVDC)整流站近区时,系统的次同步振荡(subsynchronous oscillation,SSO)特性尚不清晰,相关研究有待开展。针对上述问题,基于D-PMSG经LCC-HVDC送出系统,利用模块化分块建模法建立小信号模型,用特征值与参与因子研究了系统SSO模式中D-PMSG与LCC-HVDC的参与情况,并用特征值分析了系统参数对SSO阻尼的影响。研究结果表明:存在D-PMSG与LCC-HVDC共同参与的SSO模式,且LCC-HVDC接入为系统SSO提供负阻尼;当D-PMSG输电线路阻抗、GSC控制器外环积分系数增大时,SSO模式阻尼减小;当GSC控制器外环比例系数、D-PMSG直流侧电容、D-PMSG的风速、LCC-HVDC定电流控制器的比例系数增大时,SSO模式阻尼增大。基于PSCAD/EMTDC时域仿真结果,验证理论分析的正确性。展开更多
文摘The present study was carried out in order to track the maximum power point in a variable speed turbine by minimizing electromechanical torque changes using a sliding mode control strategy. In this strategy, first, the rotor speed is set at an optimal point for different wind speeds. As a result of which, the tip speed ratio reaches an optimal point, mechanical power coefficient is maximized, and wind turbine produces its maximum power and mechanical torque. Then, the maximum mechanical torque is tracked using electromechanical torque. In this technique, tracking error integral of maximum mechanical torque, the error, and the derivative of error are used as state variables. During changes in wind speed, sliding mode control is designed to absorb the maximum energy from the wind and minimize the response time of maximum power point tracking(MPPT). In this method, the actual control input signal is formed from a second order integral operation of the original sliding mode control input signal. The result of the second order integral in this model includes control signal integrity, full chattering attenuation, and prevention from large fluctuations in the power generator output. The simulation results, calculated by using MATLAB/m-file software, have shown the effectiveness of the proposed control strategy for wind energy systems based on the permanent magnet synchronous generator(PMSG).
文摘This paper studied the direct-drive permanent magnet synchronous machine (permanent magnet synchronous generator, PMSG) Chopper optimal topology and resistance value. Compared the different Chopper circuit low voltage ride-through capability in the same grid fault conditions in simulation. This paper computes the dump resistance ceiling according to the power electronic devices and over-current capability. Obtaining the dump resistance low limit according to the temperature resistance allows, and calculating the optimal value by drop voltage in the DC-Bus during the fault. The feasibility of the proposed algorithm is verified by simulation results.
基金supported by the National Natural Science Foundation of China (No. 52277094)Science and Technology Project of China Huaneng Group Co.,Ltd.(No. HNKJ20-H88)。
文摘The high-speed simulation of large-scale offshore wind farms(OWFs) preserving the internal machine information has become a huge challenge due to the large wind turbine(WT) count and microsecond-range time step. Hence, it is undoable to investigate the internal node information of the OWF in the electro-magnetic transient(EMT) programs. To fill this gap,this paper presents an equivalent modeling method for largescale OWF, whose accuracy and efficiency are guaranteed by integrating the individual devices of permanent magnet synchronous generator(PMSG) based WT. The node-elimination algorithm is used while the internal machine information is recursively updated. Unlike the existing aggregation methods, the developed EMT model can reflect the characteristics of each WT under different wind speeds and WT parameters without modifying the codes. The access to each WT controller is preserved so that the time-varying dynamics of all the WTs could be simulated. Comparisons of the proposed model with the detailed model in PSCAD/EMTDC have shown very high precision and high efficiency. The proposed modeling procedures can be used as reference for other types of WTs once the structures and parameters are given.
文摘A wind energy conversion system(WECS)based on a permanent magnet synchronous generator(PMSG)is an effective solution for renewable energy generation in modern power systems.The main advantages of PMSG include high performance at high and low speeds,minimal control effort owing to lower rotor inertia,self-excitation,high reliability,and simplicity of structure compared with induction generators.However,the intermittent nature of wind energy implies that maximum efficiency is not obtained from this system.Accordingly,maximum power point tracking(MPPT)in wind turbine systems has been proposed to address this problem.Traditional MPPT strategies suffer from severe output power fluctuations,low efficiency,and significant ripples in turbine rotation speed.This paper presents a novel MPPT control strategy based on fuzzy logic control(FLC)and model predictive control(MPC)to extract the maximum power from a PMSG-WECS and control the machine-side and grid-side converters.The simulation results obtained from Matlab/Simulink confirm the superiority of the control model in eliminating the output power fluctuations of the wind generators and accurately tracking the maximum power point.A comparative study between conventional MPPT and control methods is also conducted.
文摘In a permanent magnet synchronous generator(PMSG)system,conversion systems are major points of failure that create expensive and time-consuming problems.Fault detection is usually used to achieve a steady system.This paper presents a full analysis of a PMSG system for wind turbines(WT)and proposes a fault detection method using correlation features.The proposed method is motivated by the balance among the three-phase currents both before and after an opencircuit fault occurs in a converter of the PMSG system.It is unnecessary to analyze the output waveforms of a converter during fault detection.In this study,two correlation features of stator currents,the mean and covariation,are extracted to train an artificial neural network(ANN),thereby enhancing the performance of the proposed method under different wind speed conditions.Moreover,additional sensors and the collection of a massive amount of data are not required.Model simulations of an ideal inverter and a PMSG system are conducted using PSCAD software.The simulation results show that the proposed method can detect the locations of faulty switches with a diagnostic rate greater than 99.4%for the ideal inverter,and the PMSG drives settings at different wind speeds.
文摘This paper investigates a variable speed wind turbine based on permanent magnet synchronous generator and a full-scale power converter in a stand-alone system.An energy storage system(ESS)including battery and fuel cell-electrolyzer combination is connected to the DC link of the full-scale power converter through the power electronics interface.Wind is the primary power source of the system,the battery and FC-electrolyzer combination is used as a backup and a long-term storage system to provide or absorb power in the stand-alone system,respectively.In this paper,a control strategy is proposed for the operation of this variable speed wind turbine in a stand-alone system,where the generator-side converter and the ESS operate together to meet the demand of the loads.This control strategy is competent for supporting the variation of the loads or wind speed and limiting the DC-link voltage of the full-scale power converter in a small range.A simulation model of a variable speed wind turbine in a stand-alone system is developed using the simulation tool of PSCAD/EMTDC.The dynamic performance of the stand-alone wind turbine system and the proposed control strategy is assessed and emphasized with the simulation results.
文摘随着高压直流输电工程的不断投产,以及风电项目的增多,越来越多的风电场出现在电网换相换流器高压直流输电(line-commutated-converter based high voltage direct current,LCC-HVDC)受端换流站近区,两者构成的系统存在振荡风险。为此,该文针对直流受端馈入站与近区风电场系统的振荡特性展开研究。首先,建立并验证系统的状态空间模型,基于该模型计算出系统特征值,确定LCC-HVDC与风电场共同参与的振荡主导模式并进行参与因子分析。进一步地,通过对比是否接入LCC-HVDC的主导模式,得到LCC-HVDC的接入会削弱系统阻尼的结论。最后,从系统额定容量、交流系统短路比、风电场并网线路长度等方面探究系统稳定性的影响因素,并分析系统的不同短路比、潮流比对风机网侧换流器(grid-side converter,GSC)外环控制和换流站定电流控制器性能的影响。
文摘文中提出将新型的三相Z源逆变器应用于永磁同步发电机PMSG(permanent magnet synchronous generator)风力并网发电系统中,分析了此系统下的风能最大功率点跟踪MPPT(maximum power point tracking)原理。阐明了三相Z源逆变器直通占空比和发电机输出转速之间的关系,并设计了基于最大功率曲线的MPPT算法。该算法可省去风速和转速的测量,降低了系统的成本。利用计算机仿真绘图说明了系统做MPPT的工作点调节过程。最后的实验证实了理论分析和算法的正确法。
文摘当直驱风机(direct-drive permanent magnet synchronous generator,D-PMSG)位于电网换相换流器高压直流输电(line-commutated-converter based high voltage direct current,LCC-HVDC)整流站近区时,系统的次同步振荡(subsynchronous oscillation,SSO)特性尚不清晰,相关研究有待开展。针对上述问题,基于D-PMSG经LCC-HVDC送出系统,利用模块化分块建模法建立小信号模型,用特征值与参与因子研究了系统SSO模式中D-PMSG与LCC-HVDC的参与情况,并用特征值分析了系统参数对SSO阻尼的影响。研究结果表明:存在D-PMSG与LCC-HVDC共同参与的SSO模式,且LCC-HVDC接入为系统SSO提供负阻尼;当D-PMSG输电线路阻抗、GSC控制器外环积分系数增大时,SSO模式阻尼减小;当GSC控制器外环比例系数、D-PMSG直流侧电容、D-PMSG的风速、LCC-HVDC定电流控制器的比例系数增大时,SSO模式阻尼增大。基于PSCAD/EMTDC时域仿真结果,验证理论分析的正确性。