期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Single-Shot Measurement of Transient Phase Shift Induced by Laser Wake
1
作者 董军 卢宗贵 +8 位作者 张波 彭志涛 孙志红 夏彦文 元浩宇 唐军 朱德燕 刘华 吕嘉坤 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第5期60-62,共3页
Based on the frequency-to-time mapping relation of the linearly chirped pulse, the temporal phase shift induced by a laser-excited wake in a helium gas jet is measured using a chirped-pulse spectral interferometry wi... Based on the frequency-to-time mapping relation of the linearly chirped pulse, the temporal phase shift induced by a laser-excited wake in a helium gas jet is measured using a chirped-pulse spectral interferometry with ~ 140 fs resolution over a temporal region of I ps in a single shot. In this measurement, the image of the wake is obtained with one-dimensional spatial resolution and temporal resolution limited only by the bandwidth and chirp of the pulse. The 'bubbles' feature of the wake structure, along with multiple wakes excited by the main lobe and the side lobe of a laser focal-spot, is captured simultaneously. 展开更多
关键词 Single-Shot measurement of Transient phase shift Induced by Laser Wake
下载PDF
A NEW ALGORITHM FOR ELIMINATING PHASE-SHIFT ERROR IN PHASE SHIFTING INTERFEROMETRY
2
作者 Liu Chong Liang Xichang Peng Donglin State Key Laboratory of Mechanical Transmission,Chongqing University 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 1999年第2期51-55,共5页
The effect of phaseshift error in phase shifting interferometry is investigated. A new algorithm with two sets of 4 samples for eliminating phase shift error is presented. The computer simulation and experiment resul... The effect of phaseshift error in phase shifting interferometry is investigated. A new algorithm with two sets of 4 samples for eliminating phase shift error is presented. The computer simulation and experiment result show that the phase shift offset should be π when the algorithm is used, and this algorithm has gotten better result than the original 4 sample algorithm. 展开更多
关键词 phase shifting interferometry Error compensation Profile measurement
全文增补中
A Portable Analog Lock-In Amplifier for Accurate Phase Measurement and Application in High-Precision Optical Oxygen Concentration Detection 被引量:2
3
作者 Xi CHEN Jun CHANG +4 位作者 Fupeng WANG Zongliang WANG Wei WEI Yuanyuan LIU Zengguang QIN 《Photonic Sensors》 SCIE EI CAS CSCD 2017年第1期27-36,共10页
A portable analog lock-in amplifier capable of accurate phase detection is proposed in this paper. The proposed lock-in amplifier, which uses the dual-channel orthometric signals as the references to build the xy coor... A portable analog lock-in amplifier capable of accurate phase detection is proposed in this paper. The proposed lock-in amplifier, which uses the dual-channel orthometric signals as the references to build the xy coordinate system, can detect the relative phase between the input and x-axis based on trigonometric function. The sensitivity of the phase measurement reaches 0.014degree, and a detection precision of 0.1 degree is achieved. At the same time, the performance of the lock-in amplifier is verified in the high precision optical oxygen concentration detection. Experimental results reveal that the portable analog lock-in amplifier is accurate for phase detection applications. In the oxygen sensing experiments, 0.058% oxygen concentration resulted in 0.1 degree phase shift detected by the lock-in amplifier precisely. In addition, the lock-in amplifier is small and economical compared with the commercial lock-in equipments, so it can be easily integrated in many portable devices for industrial applications. 展开更多
关键词 Portable analog lock-in amplifier phase shift measurement high accuracy optical oxygen detection
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部