Wind power has developed rapidly in recent years,and large-scale wind power facilities connected to power grids will bring many new challenges.Some new operation charac-teristics of power grids with doubly-fed inducti...Wind power has developed rapidly in recent years,and large-scale wind power facilities connected to power grids will bring many new challenges.Some new operation charac-teristics of power grids with doubly-fed induction generator(DFIG)may exhibit,for example voltage phase angle jumps(VPAJ).VPAJ can negatively impact the fault ride through(FRT)performance of DFIG.This paper firstly investigates the physical mechanism and the operation characteristics of DFIG with VPAJ.It is noted that the current control strategies designed for voltage amplitude changes are not suitable for VPAJ.Secondly,the paper develops an FRT optimization control strategy under VPAJ which optimizes the DFIG operation characteristics.Finally,simulations of a 250 MW wind farm are presented which validate the proposed FRT strategy.展开更多
In the condition of connecting large scale doubly-fed induction generators (DFIGs) into weak grid,the closely coupled interactions between wind generators and power grid becomes more severe.Some new fault characterist...In the condition of connecting large scale doubly-fed induction generators (DFIGs) into weak grid,the closely coupled interactions between wind generators and power grid becomes more severe.Some new fault characteristics including voltage phase angle jump will emerge,which will influence the power quality of power system.However,there are very few studies focusing on the mechanism of voltage phase angle jump under grid fault in a weak grid with wind turbine integration.This paper focuses on the scientific issues and carries out mechanism studies from different aspects,including mathematical deduction,field data analysis and time domain simulation.Based on the analysis of transientcharacteristics of DFIGs during the grid fault,this paper points out that the change of terminal voltage phase angle in DFIGs is an electromagnetism transition process,which is different from conventional synchronous generator.Moreover,the impact on transient characteristics of voltage phase angle are revealed in terms of fault ride through(FRT) control strategies,control parameters of current inner-loop of rotor-side converter and grid strength.展开更多
Wind power in China has experienced fast development in recent years. However, areas rich in wind power resources are often far away from loads centers,which leads to weak connection between wind turbines and power gr...Wind power in China has experienced fast development in recent years. However, areas rich in wind power resources are often far away from loads centers,which leads to weak connection between wind turbines and power grid. When a grid fault occurs, new transient characteristics in weak grid integrated with doubly-fed induction generators(DFIGs) may present, such as voltage phase angle jump. Current control strategies for wind turbine with strong grid connection are hard to be adapted under weak gird connection. This paper explores the transient characteristics of DFIGs under voltage phase angle jump through analyzing the operation and control characteristics of DFIGs connected into weak grid when the voltage phase angle jumps. Fault ride through(FRT) control strategy of DFIGs based on adaptive phase-locked loop is proposed to adapt weak grid condition. The reference frame of the proposed strategy will be changed in real-time to track the operation condition of DFIGs according to the terminal voltage, and different phase tracking method is adopted during the grid fault. Field data analysis and time domain simulation are carried out. The results show that voltage phase angle jumps when a grid fault occurs, which weakens the FRT capability of DFIGs, and the proposed FRT control strategy can optimize transient characteristics of DFIGs, and improve the FRT capability of DFIGs.展开更多
基金This work was supported by The National Natural Science Foundation of China(No.51577174).
文摘Wind power has developed rapidly in recent years,and large-scale wind power facilities connected to power grids will bring many new challenges.Some new operation charac-teristics of power grids with doubly-fed induction generator(DFIG)may exhibit,for example voltage phase angle jumps(VPAJ).VPAJ can negatively impact the fault ride through(FRT)performance of DFIG.This paper firstly investigates the physical mechanism and the operation characteristics of DFIG with VPAJ.It is noted that the current control strategies designed for voltage amplitude changes are not suitable for VPAJ.Secondly,the paper develops an FRT optimization control strategy under VPAJ which optimizes the DFIG operation characteristics.Finally,simulations of a 250 MW wind farm are presented which validate the proposed FRT strategy.
基金supported by National Basic Research Program of China(973 Program)(No.2012CB215105)
文摘In the condition of connecting large scale doubly-fed induction generators (DFIGs) into weak grid,the closely coupled interactions between wind generators and power grid becomes more severe.Some new fault characteristics including voltage phase angle jump will emerge,which will influence the power quality of power system.However,there are very few studies focusing on the mechanism of voltage phase angle jump under grid fault in a weak grid with wind turbine integration.This paper focuses on the scientific issues and carries out mechanism studies from different aspects,including mathematical deduction,field data analysis and time domain simulation.Based on the analysis of transientcharacteristics of DFIGs during the grid fault,this paper points out that the change of terminal voltage phase angle in DFIGs is an electromagnetism transition process,which is different from conventional synchronous generator.Moreover,the impact on transient characteristics of voltage phase angle are revealed in terms of fault ride through(FRT) control strategies,control parameters of current inner-loop of rotor-side converter and grid strength.
基金supported by the National Basic Research Program of China(973 Program)(No.2012CB215105)National Natural Science Foundation of China(No.51577174)
文摘Wind power in China has experienced fast development in recent years. However, areas rich in wind power resources are often far away from loads centers,which leads to weak connection between wind turbines and power grid. When a grid fault occurs, new transient characteristics in weak grid integrated with doubly-fed induction generators(DFIGs) may present, such as voltage phase angle jump. Current control strategies for wind turbine with strong grid connection are hard to be adapted under weak gird connection. This paper explores the transient characteristics of DFIGs under voltage phase angle jump through analyzing the operation and control characteristics of DFIGs connected into weak grid when the voltage phase angle jumps. Fault ride through(FRT) control strategy of DFIGs based on adaptive phase-locked loop is proposed to adapt weak grid condition. The reference frame of the proposed strategy will be changed in real-time to track the operation condition of DFIGs according to the terminal voltage, and different phase tracking method is adopted during the grid fault. Field data analysis and time domain simulation are carried out. The results show that voltage phase angle jumps when a grid fault occurs, which weakens the FRT capability of DFIGs, and the proposed FRT control strategy can optimize transient characteristics of DFIGs, and improve the FRT capability of DFIGs.