The synthetic making test has been widely used in evaluating the break ability of high-voltage circuit breaker. However, the test research and application are still inadequate, especially in the condition of rated vol...The synthetic making test has been widely used in evaluating the break ability of high-voltage circuit breaker. However, the test research and application are still inadequate, especially in the condition of rated voltage. According to the realistic conditions of test stations in China, a control device based on pre-arcing current detection and phase control is proposed in this paper. A sample of the control device made up of DSP TMS320LF2407A is fabricated, in which the CPLD MAX7064 is used to transmit signals for EMC design. It can be applied in full voltage synthetic making test at a level of 126kV/63kA. The test results show that, it is accurate to control the making phase of the applied voltage, whether the closing is demanded at voltage peak or zero.展开更多
It is well accepted that lower hybrid current drive (LHCD) is the most efficient method for non-inductive current drive in fusion devices and the effect of the current drive is dependent on not only microwave power ...It is well accepted that lower hybrid current drive (LHCD) is the most efficient method for non-inductive current drive in fusion devices and the effect of the current drive is dependent on not only microwave power but also its grill phase shift. This paper presents a new kind of feedback control system for antenna phase difference in LHCD experiments. In this highspeed control system, a lot of new technologies and methods are incorporated. The results of the experiments show a very good agreement with the system design.展开更多
In this paper, on the basis of the phase shifted controlled zero voltage switch (ZVS) full bridge converter with pulse width modulation (PWM), a novel zero voltage and zero current switch (ZVZCS) PWM converter u...In this paper, on the basis of the phase shifted controlled zero voltage switch (ZVS) full bridge converter with pulse width modulation (PWM), a novel zero voltage and zero current switch (ZVZCS) PWM converter using a simple auxiliary circuit was designed. The ZVZCS soft switch is achieved by the resonance among the resisting electromagnetic deflection capacitor, the capacitor of the simple auxiliary network and the leakage inductor of transformer. There are no dissipation devices of the saturation inductor and the auxiliary switch in the converter, meantime the capacitor of the auxiliary circuit is also used to clamp the voltage of the rectifier, and there is no additional clamped circuit. There is no big circulating current in the converter, all the active and passive devices work on the condition of the low current and voltage stress, and the proposed converter has wide load range and small duty loss.展开更多
有源电力滤波器(active power filter,APF)的谐波电流控制直接影响着APF的滤波效果。针对指数趋近率容易产生抖振的问题,提出了一种变指数趋近率,并在dq坐标系下推导出了基于该变指数趋近率的APF滑模控制律。为提高APF对高次谐波的追踪...有源电力滤波器(active power filter,APF)的谐波电流控制直接影响着APF的滤波效果。针对指数趋近率容易产生抖振的问题,提出了一种变指数趋近率,并在dq坐标系下推导出了基于该变指数趋近率的APF滑模控制律。为提高APF对高次谐波的追踪能力,将重复控制和基于变指数趋近率的滑模控制并联,提出了一种APF的重复滑模控方法。仿真结果表明,相对于基于指数趋近率的滑模控制方法,提出的重复滑模控制方法具有更高的稳态精度,电网电流的谐波畸变率更低。展开更多
文摘The synthetic making test has been widely used in evaluating the break ability of high-voltage circuit breaker. However, the test research and application are still inadequate, especially in the condition of rated voltage. According to the realistic conditions of test stations in China, a control device based on pre-arcing current detection and phase control is proposed in this paper. A sample of the control device made up of DSP TMS320LF2407A is fabricated, in which the CPLD MAX7064 is used to transmit signals for EMC design. It can be applied in full voltage synthetic making test at a level of 126kV/63kA. The test results show that, it is accurate to control the making phase of the applied voltage, whether the closing is demanded at voltage peak or zero.
基金Meg-science Engineering Project of the Chinese Academy of Sciences
文摘It is well accepted that lower hybrid current drive (LHCD) is the most efficient method for non-inductive current drive in fusion devices and the effect of the current drive is dependent on not only microwave power but also its grill phase shift. This paper presents a new kind of feedback control system for antenna phase difference in LHCD experiments. In this highspeed control system, a lot of new technologies and methods are incorporated. The results of the experiments show a very good agreement with the system design.
文摘In this paper, on the basis of the phase shifted controlled zero voltage switch (ZVS) full bridge converter with pulse width modulation (PWM), a novel zero voltage and zero current switch (ZVZCS) PWM converter using a simple auxiliary circuit was designed. The ZVZCS soft switch is achieved by the resonance among the resisting electromagnetic deflection capacitor, the capacitor of the simple auxiliary network and the leakage inductor of transformer. There are no dissipation devices of the saturation inductor and the auxiliary switch in the converter, meantime the capacitor of the auxiliary circuit is also used to clamp the voltage of the rectifier, and there is no additional clamped circuit. There is no big circulating current in the converter, all the active and passive devices work on the condition of the low current and voltage stress, and the proposed converter has wide load range and small duty loss.
文摘有源电力滤波器(active power filter,APF)的谐波电流控制直接影响着APF的滤波效果。针对指数趋近率容易产生抖振的问题,提出了一种变指数趋近率,并在dq坐标系下推导出了基于该变指数趋近率的APF滑模控制律。为提高APF对高次谐波的追踪能力,将重复控制和基于变指数趋近率的滑模控制并联,提出了一种APF的重复滑模控方法。仿真结果表明,相对于基于指数趋近率的滑模控制方法,提出的重复滑模控制方法具有更高的稳态精度,电网电流的谐波畸变率更低。