Based on color-locking noisy field correlation in three Markovian stochastic models, phase dispersions of the Raman- and Rayleigh-enhanced four-wave mixing (FWM) have been investigated. The phase dispersions are mod...Based on color-locking noisy field correlation in three Markovian stochastic models, phase dispersions of the Raman- and Rayleigh-enhanced four-wave mixing (FWM) have been investigated. The phase dispersions are modified by both linewidth and time delay for negative time delay, but only by linewidth for positive time delay. Moreover, the results under narrowband condition are close to the nonmodified nonlinear dispersion and absorption of the material. Homodyne and heterodyne detections of the Raman, the Rayleigh and the mixing femtosecond difference-frequency polarization beats have also been investigated, separately.展开更多
[ Objective] The study aimed to determine tebuconazole residue in apples and vegetables using matrix solid phase dispersion-gas chro- matography (MSPD-GC). [ Method] The effects of extraction and determination condi...[ Objective] The study aimed to determine tebuconazole residue in apples and vegetables using matrix solid phase dispersion-gas chro- matography (MSPD-GC). [ Method] The effects of extraction and determination conditions on the detection of tebuconazole left in apples and veg- etables were analyzed, and the optimum extraction conditions were determined. [ Result] The recovery rate of tebucenazole was the highest when the ratio of a sample to florisil dispersant was 1 : 4, and the mixture of hexane and acetone ( 1 : 1 ) with total volume of 8 ml was as the eluant. Under the optimum conditions, the relative standard deviation (RSD) of the method was 4.9% -7.6%, and the detection limit was 0.1 tJg/g, while the re- covery rate of tebuconazole changed from 86.7% to 95. 2% . [ Conclusion] The method was simple, accurate, sensitive and applicable to the de- termination of tebuconazole in aaricultural Droducts.展开更多
A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet de...A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples.展开更多
Background: Rheumatoid arthritis is a form of autoimmune disease characterized by synovitis that can ultimately cause joint deformities and impaired functioning. The cartilage destruction is one of the most important ...Background: Rheumatoid arthritis is a form of autoimmune disease characterized by synovitis that can ultimately cause joint deformities and impaired functioning. The cartilage destruction is one of the most important indicators for diagnosis and treatment of rheumatoid arthritis, and it is radiographically manifested as joint space narrowing. Issue: In the literature, the joint space narrowing progression between a baseline and its follow-up finger joint images can be quantified by using image registration algorithm. We found that the inconsistencies of joint angles may lead to characteristic mismatches and thus severely affect the accuracy of joint space narrowing quantifications. Methods: In this work, we introduce a rotation invariant phase only correlation in joint space narrowing quantification for the joint angle correction. Further, we propose a confidence index to quantify the quantification reliability of phase only correlation based on phase dispersion in phase difference spectrum. Conclusion: In our clinical experiments, the proposed quantification method can effectively overcome and manage the mismatch due to the inconsistency of joint angles. Additionally, the confidence index shows a high consistency with the joint space narrowing progression examinations manually done by a trained radiologist and one radiological technologist.展开更多
This paper presents a weakly nonlinear water wave model using a mild slope equation and a new explicit formulation which takes into account dispersion of wave phase velocity, approximates Hedges’ (1987) nonlinear dis...This paper presents a weakly nonlinear water wave model using a mild slope equation and a new explicit formulation which takes into account dispersion of wave phase velocity, approximates Hedges’ (1987) nonlinear dispersion relationship, and accords well with the original empirical formula. Comparison of the calculating results with those obtained from the experimental data and those obtained from linear wave theory showed that the present water wave model considering the dispersion of phase velocity is rational and in good agreement with experiment data.展开更多
Mass transfer enhancement of gas absorption by adding a dispersed organic phase has been studied in this work. Various dispersed organic phases (heptanol, octanol, isoamyl alcohol, heptane, octane, and isooctane) we...Mass transfer enhancement of gas absorption by adding a dispersed organic phase has been studied in this work. Various dispersed organic phases (heptanol, octanol, isoamyl alcohol, heptane, octane, and isooctane) were tested respectively in the experiment. According to the theoretical model and experimental data, the overall volumetric mass transfer coefficient and enhancement factor were obtained under different dispersed organic phase volume fraction and stirring speed. The experimental results indicate that gas-liquid mass transfer is enhanced at different level by adding a dispersed organic phase. The best performance of enhancement were achieved with the dispersed organic phase volumetric fraction of 5% and under an intermediate stirring speed of 670 r·min^-1. Among the organic phases tested in the experiment, alcohols show better performance, which gave 20% higher enhance-ment of overall volumetric mass transfer coefficient than adding alkanes.展开更多
Using experimental data from a number of pulsed disc and doughnut solvent extraction columns, a unified correla- tion for the prediction of dispersed phase holdup that considers the effects of mass transfer is present...Using experimental data from a number of pulsed disc and doughnut solvent extraction columns, a unified correla- tion for the prediction of dispersed phase holdup that considers the effects of mass transfer is presented. Pulsed disc and doughnut solvent extraction columns (PDDC) have been used for a range of important applications such as ura- nium extraction and nuclear fuel recycling. Although the dispersed phase holdup in a PDDC has been presented by some researchers, there is still the need to develop a robust correlation that can predict the experimental dispersed phase holdup over a range of operating conditions including the effects of mass transfer direction. In this study, dis- persed phase holdup data from different literature sources for a PDDC were used to refit constants for the correlation presented by Kumar and Hartland lind. Eng. Chem. Res.,27 (1988),131-138] which did not consider the effect of col- umn geometry. In order to incorporate the characteristic length of the PDDC (i.e. the plate spacing), the unified cor- relation for holdup proposed by Kumar and Hartland based on data from eight different types of columns [Ind. Eng. Chem. Res.,34 (1995) 3925-3940] was refitted to the PDDC data. New constants have been presented for each hold- up correlation for a PDDC based on regression analysis using published holdup data from PDDCs that cover a range of onerating conditions and nhwical nronerties and consider the direction of mass transfer.展开更多
We have prepared novel coated particles, with a conductor graphite core and a dielectric TiO2 coating, as the dispersed phase of electrorheological fluids. One order of magnitude enhancement in the shear stress is obt...We have prepared novel coated particles, with a conductor graphite core and a dielectric TiO2 coating, as the dispersed phase of electrorheological fluids. One order of magnitude enhancement in the shear stress is obtained by using such composite particles, when it is compared with that of TiO2 particles. The experimental results show a way to get excellent ER system.展开更多
The transport of Tb(III) in dispersion supported liquid membrane(DSLM) with polyvinylidene fluoride membrane(PVDF) as the support and dispersion solution including HCl solution as the stripping solution and di(...The transport of Tb(III) in dispersion supported liquid membrane(DSLM) with polyvinylidene fluoride membrane(PVDF) as the support and dispersion solution including HCl solution as the stripping solution and di(2-ethylhexyl) phosphoric acid(D2EHPA) dissolved in kerosene as the membrane solution, has been studied. The effects of pH value, initial concentration of Tb(III) and different ionic strength in the feed phase, volume ratio of membrane solution to stripping solution, concentration of HCl solution, concentration of carrier, different stripping agents in the dispersion phase on the transport of Tb(III) have also been investigated, respectively. As a result, the optimum transport conditions of Tb(III) were obtained, i.e., the concentration of HCl solution was 4.0 mol/L, the concentration of D2EHPA was 0.16 mol/L, the volume ratio of membrane solution to stripping solution was 30:30 in the dispersion phase and pH value was 4.5 in the feed phase. Ionic strength had no obvious effect on the transport of Tb(III). Under the optimum conditions, the transport percentage of Tb(III) was up to 96.1% in a transport time of 35 min when the initial concentration of Tb(IIl) was 1.0× 10 -4 mol/L. The diffusion coefficient of Tb(III) in the membrane and the thickness of diffusion layer between feed phase and membrane phase were obtained and the values were 1.82×10 -8 m2/s and 5.61 um, respectively. The calculated results were in good agreement with the literature data.展开更多
Residues of tetracycline antibiotics(TCs) in environments may be harmful to human.Due to their high polarities,it is extremely challenging to efficiently enrich TCs with low concentrations in natural waters for analys...Residues of tetracycline antibiotics(TCs) in environments may be harmful to human.Due to their high polarities,it is extremely challenging to efficiently enrich TCs with low concentrations in natural waters for analysis.In this work,a magnetic metal-organic framework Fe_(3)O_(4)@[Cu_(3)(btc)_(2)]was synthesized and applied as a dispersive micro-solid phase extraction adsorbent for TCs enrichment.Effects of dispersive micro-solid phase extraction conditions including extraction time,solution p H,and elution solvent on the extraction efficiencies of TCs were investigated.Results show that TCs could be enriched efficiently by Fe_(3)O_(4)@[Cu_(3)(btc)_(2)],and electrostatic interaction between TCs and Fe_(3)O_(4)@[Cu_(3)(btc)_(2)]dominated this process.Combined with liquid chromatography-tandem mass spectrometry,four TCs residues (oxytetracycline,tetracycline,chlortetracycline,and doxycycline) in natural waters were determined.The detection limits (LOD,S/N=3) of the four antibiotics were 0.01-0.02μg/L,and the limits of quantitation (LOQ,S/N=10)were 0.04-0.07μg/L.The recoveries obtained from river water and aquaculture water spiked with three TCs concentration levels ranged from 70.3%to 96.5%with relative standard deviations of 3.8%-12.8%.Results indicate that the magnetic metal-organic framework based dispersive micro-solid phase extraction is simple,rapid and high-loading for antibiotics enrichment from water,which further expand the practical application of metal-organic frameworks in sample pretreatment for environmental pollutant analysis.展开更多
The mass transfer process in a perforated rotating disk contactor(PRDC) using a toluene-acetone-water system was investigated.The volumetric overall mass transfer coefficients are calculated in a PRDC column.Both mass...The mass transfer process in a perforated rotating disk contactor(PRDC) using a toluene-acetone-water system was investigated.The volumetric overall mass transfer coefficients are calculated in a PRDC column.Both mass transfer directions are considered in experiments.The influences of operating variables containing agitation rate,dispersed and continuous phase flow rates and mass transfer in the extraction column are studied.According to obtained results,mass transfer is significantly dependent on agitation rate,while the dispersed and continuous phase flow rates have a minor effect on mass transfer in the extraction column.Furthermore,a novel empirical correlation is developed for prediction of overall continuous phase Sherwood number based on dispersed phase holdup,Reynolds number and mass transfer direction.There has been great agreement between experimental data and predicted values using a proposed correlation for all operating conditions.展开更多
Fast ionic conductors are one kind of solid state material with ionic conductivity as high as that of melten salts or liquid electrolytes.Ionic conductivity is one of the important parameters for characterizing a fast...Fast ionic conductors are one kind of solid state material with ionic conductivity as high as that of melten salts or liquid electrolytes.Ionic conductivity is one of the important parameters for characterizing a fast ionic conductor.For a long time materialists and chemists have made great efforts in search of new fast ionic conductors with high ionic conductivity.In view of structure,they have synthesised silver and copper fast ionic conductors with so called open structures.But it is not so successful for searching more applicable alkaline fast ionic conductors.Since polymer has flexibility for making thin film,it concentrates attention on the polymer-alkaline salt complex.Fenton et al.have first reported poly(ethylene oxide) (PEO)-alkaline salt complex.Later on Armard et al.have investigated the electrical property of PEO-NaSCN.展开更多
Analysis of pesticide residue levels in juice beverages is important to ensure safe consumption and avoid global trade concerns associated to pesticide contaminations.A simple,inexpensive and effective method was deve...Analysis of pesticide residue levels in juice beverages is important to ensure safe consumption and avoid global trade concerns associated to pesticide contaminations.A simple,inexpensive and effective method was developed for the determination of organochlorine pesticides(OCPs)in bottled juice drinks using GC-MS.Sample pretreatment was performed using dispersive solid-phase microextraction(D-μ-SPE)for matrix desorption and dispersive liquid-liquid microextraction(DLLME)for analyte enrichment.In this study,an affordable and effective sorbent for the adsorption of OCPs from juice samples was synthesized from avocado seeds mixed with magnetic precursors for D-μSPE.The ground avocado seeds combined with a magnetic precursor nanocomposite were characterized using various instruments including scanning electron microscopy(SEM),X-ray diffraction(XRD),Fourier transform infrared spectroscopy(FTIR),and Brunauer-Emmett-Teller(BET)analysis.The solution obtained from D-μ-SPE desorption was used as a dispersant for the subsequent DLLME,which made the combination of D-μ-SPE with DLLME much easier.The effectiveness of the method was enhanced by optimizing the influential parameters in both D-μ-SPE and DLLME.Then after,the optimal values were determined for the real sample analysis.Accordingly,there was good linear dynamic range with a coefficient of determination(r2)≥0.9989.The limit of detection and quantification were 0.02–0.69 and 0.06–2.10 ng/L respectively.The method showed high enrichment factors ranging from 96 to 313 with recoveries of 87–100%.Intraday and interday precisions were≤4%.Compared with other reported methods,this method is a one-step,simple,cheap,fast,and environmentally friendly alternative and straightforward method for adsorbing organochlorine pesticides from sample solutions.These results demonstrates the high potential of the proposed method for the extraction and cleanup of contaminants in selected juices and other related samples.展开更多
On the basis of the finite element analysis, the elastic wave propagation in cellular structures is investigated using the symplectic algorithm. The variation principle is first applied to obtain the dual variables an...On the basis of the finite element analysis, the elastic wave propagation in cellular structures is investigated using the symplectic algorithm. The variation principle is first applied to obtain the dual variables and the wave propagation problem is then transformed into two-dimensional (2D) symplectic eigenvalue problems, where the extended Wittrick-Williams algorithm is used to ensure that no phase propagation eigenvalues are missed during computation. Three typical cellular structures, square, triangle and hexagon, are introduced to illustrate the unique feature of the symplectic algorithm in higher-frequency calculation, which is due to the conserved properties of the structure-preserving symplectic algorithm. On the basis of the dispersion relations and phase constant surface analysis, the band structure is shown to be insensitive to the material type at lower frequencies, however, much more related at higher frequencies. This paper also demonstrates how the boundary conditions adopted in the finite element modeling process and the structures' configurations affect the band structures. The hexagonal cells are demonstrated to be more efficient for sound insulation at higher frequencies, while the triangular cells are preferred at lower frequencies. No complete band gaps are observed for the square cells with fixed-end boundary conditions. The analysis of phase constant surfaces guides the design of 2D cellular structures where waves at certain frequencies do not propagate in specified directions. The findings from the present study will provide invaluable guidelines for the future application of cellular structures in sound insulation.展开更多
Mass transfer characteristics have been investigated in a 113 mm diameter asymmetric rotating disk contactor of the pilot plant scale for two different liquid–liquid systems. The effects of operating parameters inclu...Mass transfer characteristics have been investigated in a 113 mm diameter asymmetric rotating disk contactor of the pilot plant scale for two different liquid–liquid systems. The effects of operating parameters including rotor speed and continuous and dispersed phase velocities on the volumetric overall mass transfer coefficients are investigated. The results show that the mass transfer performance is strongly dependent on agitation rate and interfacial tension, but only slightly dependent on phase flow rates. In this study, effective diffusivity is used instead of molecular diffusivity in the Grober equation for estimation of dispersed phase overall mass transfer coefficient.The enhancement factor is determined experimentally and there from an empirical expression is derived for prediction of the enhancement factor as a function of Reynolds number. The predicted results compared to the experimental data show that the proposed correlation can efficiently predict the overall mass transfer coefficients in asymmetric rotating disk contactors.展开更多
Polypropylene(PP)/ethylene-octene copolymer(POE) blends were prepared with a twin-screw extruder.Their dynamic mechanical behavior were systematically investigated.The results show that PP/POE blends are heterogen...Polypropylene(PP)/ethylene-octene copolymer(POE) blends were prepared with a twin-screw extruder.Their dynamic mechanical behavior were systematically investigated.The results show that PP/POE blends are heterogeneities with a partial compatible two-phase structure,the glass transition temperature of PP phases in the blends tends to shift towards high temperature with increasing the POE content,and the glass transition temperature of POE phases shifts towards the low temperature with increasing the PP content.The Kerner's dispersed phase model and co-continuous phase model can reasonably predict the visco-elasticity of PP/POE blends with different compositions.Additionally,the morphological structure of the blends can be estimated via comparing the predicted DMA behavior with the experimental data.展开更多
The synthesis and characterization of several dispersed molybdena catalysts on silica support (MoO3-SiO2) prepared from a variety of precursors (Mo(VI)-acetylacetonate, oxo-peroxo Mo-species, hydrated ammonium heptamo...The synthesis and characterization of several dispersed molybdena catalysts on silica support (MoO3-SiO2) prepared from a variety of precursors (Mo(VI)-acetylacetonate, oxo-peroxo Mo-species, hydrated ammonium heptamolybdate) and preparation methods (deposition of the Mo-phase on finite SiO2 support by aqueous and methanol impregnations, by adsorption, by oxo-peroxo route-like, and by one-step synthesis of MoO3-SiO2 system with molecular precursors) are presented. The molybdena concentration on silica was comprised in a large interval (1.5 - 14 wt%) depending on the preparation method which governed the Mo-loading on silica. Convenient comparisons among samples at similar Mo-concentration have been made discussing the morphologic-structural (XRD, XPS, UV-vis-DRS, and N2-adsorption) and physicochemical (TG-DTG, TPR, and n-butylamine-TPD) sample properties. Polymeric octahedral polymolybdate aggregates predominated in the samples prepared by aqueous and methanol impregnations, which were at high Mo-concentration. On the contrary, isolated Mo(VI) species in distorted Td symmetry predominated in the sample prepared by adsorption which was at very low Mo-concentration. The sample acidity was composed of a weak acidy site population, associated with the silica support, and a strong acid site population associated with the Mo-dispersed phase. Oxidation tests of formaldehyde, an oxygen-containing VOC (Volatile Organic Compound), were performed to determine the prevalent redox or acidic function of the Mo-species at the surface of the catalysts.展开更多
A rapid,accurate,and sensitive analytical method,ultrasonication-assisted spraying based fine droplet formationeliquid phase microextractionegas chromatographyemass spectrometry(UA-SFDF-LPME-GCMS),was proposed for the...A rapid,accurate,and sensitive analytical method,ultrasonication-assisted spraying based fine droplet formationeliquid phase microextractionegas chromatographyemass spectrometry(UA-SFDF-LPME-GCMS),was proposed for the determination of trace amounts of hydroxychloroquine sulfate in human serum,urine,and saliva samples.To determine the best extraction strategy,several liquid and solid phase extraction methods were investigated for their efficiencies in isolation and preconcentration of hydroxychloroquine sulfate from biological matrices.The UA-SFDF-LPME method was determined to be the best extraction method as it was operationally simple and provided accurate results.Variables such as the extraction solvent,spraying number,sodium hydroxide concentration and volume,sample volume,mixing method,and mixing period were optimized for the proposed method using the onevariable-at-a-time approach.In addition,Tukey’s method based on a post hoc comparison test was employed to evaluate the significant difference between the parameters inspected.After the optimization studies,the limit of detection(LOD)and limit of quantification(LOQ)were determined to be 0.7 and 2.4 mg/kg,respectively.The sensitivity of the GC-MS system based on the LOD was enhanced approximately 440-fold when the UA-SFDF-LPME method was employed.Spiking experiments were also conducted for the human serum,urine,and saliva samples to determine the applicability and accuracy of the proposed method.Recoveries for the human serum,urine,and saliva samples were found to be in the ranges of 93.9%-101.7%,95.2%-105.0%,and 93.1%-102.3%,respectively.These results were satisfactory and indicated that the hydroxychloroquine sulfate level in the above biological samples could be analyzed using the proposed method.展开更多
A novel 1-methylimidazole ionic liquid modified SBA15 mesoporous silica(1-MIIL@SBA15) was synthesized and applied to selective separation of inorganic arsenic(iAs) in rice by dispersive solid phase extraction(DSPE), f...A novel 1-methylimidazole ionic liquid modified SBA15 mesoporous silica(1-MIIL@SBA15) was synthesized and applied to selective separation of inorganic arsenic(iAs) in rice by dispersive solid phase extraction(DSPE), followed by hydride generation-atomic fluorescence spectrometric(HG-AFS) quantification. The prepared sorbent was characterized by FTIR, FESEM, BET and Zeta potential. Key parameters of adsorption and desorption in DSPE were optimized using standard reference material 1568 b rice flour. Under optimal conditions, the limit of detection was 8.776 ng/kg, relative standard deviation was ≤2.0%, and recoveries of iAs were in the 92.3~94.4% range. This method was successfully applied to the determination of iAs in rice. Under acidic condition, the electrostatic interaction between the positively charged 1-MIIL@SBA15 and anionic iAs played an important role in selective iAs separation, rendering this method suitable for iAs analysis.展开更多
基金Project supported by the National Natural Science Foundation of China (Grant No 60678005)the Foundation for the Authorof National Excellent Doctoral Dissertation of China (Grant No 200339)+1 种基金the For Ying-Tong Education Foundation for Young Teachers in the Institutions of Higher Education of China (Grant No 101061)the Specialized Research Fund for the Doctoral Program of Higher Education of China (Grant No 20050398017)
文摘Based on color-locking noisy field correlation in three Markovian stochastic models, phase dispersions of the Raman- and Rayleigh-enhanced four-wave mixing (FWM) have been investigated. The phase dispersions are modified by both linewidth and time delay for negative time delay, but only by linewidth for positive time delay. Moreover, the results under narrowband condition are close to the nonmodified nonlinear dispersion and absorption of the material. Homodyne and heterodyne detections of the Raman, the Rayleigh and the mixing femtosecond difference-frequency polarization beats have also been investigated, separately.
基金Supported by the Practice Innovation Training Program of Undergraduates in Jiangsu Province,China
文摘[ Objective] The study aimed to determine tebuconazole residue in apples and vegetables using matrix solid phase dispersion-gas chro- matography (MSPD-GC). [ Method] The effects of extraction and determination conditions on the detection of tebuconazole left in apples and veg- etables were analyzed, and the optimum extraction conditions were determined. [ Result] The recovery rate of tebucenazole was the highest when the ratio of a sample to florisil dispersant was 1 : 4, and the mixture of hexane and acetone ( 1 : 1 ) with total volume of 8 ml was as the eluant. Under the optimum conditions, the relative standard deviation (RSD) of the method was 4.9% -7.6%, and the detection limit was 0.1 tJg/g, while the re- covery rate of tebuconazole changed from 86.7% to 95. 2% . [ Conclusion] The method was simple, accurate, sensitive and applicable to the de- termination of tebuconazole in aaricultural Droducts.
基金This research was supported by Special Research Fund for Young Doctors of Qiqihar Medical University(QMSI2020B-03,hosted by Wenjing Li).
文摘A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples.
文摘Background: Rheumatoid arthritis is a form of autoimmune disease characterized by synovitis that can ultimately cause joint deformities and impaired functioning. The cartilage destruction is one of the most important indicators for diagnosis and treatment of rheumatoid arthritis, and it is radiographically manifested as joint space narrowing. Issue: In the literature, the joint space narrowing progression between a baseline and its follow-up finger joint images can be quantified by using image registration algorithm. We found that the inconsistencies of joint angles may lead to characteristic mismatches and thus severely affect the accuracy of joint space narrowing quantifications. Methods: In this work, we introduce a rotation invariant phase only correlation in joint space narrowing quantification for the joint angle correction. Further, we propose a confidence index to quantify the quantification reliability of phase only correlation based on phase dispersion in phase difference spectrum. Conclusion: In our clinical experiments, the proposed quantification method can effectively overcome and manage the mismatch due to the inconsistency of joint angles. Additionally, the confidence index shows a high consistency with the joint space narrowing progression examinations manually done by a trained radiologist and one radiological technologist.
文摘This paper presents a weakly nonlinear water wave model using a mild slope equation and a new explicit formulation which takes into account dispersion of wave phase velocity, approximates Hedges’ (1987) nonlinear dispersion relationship, and accords well with the original empirical formula. Comparison of the calculating results with those obtained from the experimental data and those obtained from linear wave theory showed that the present water wave model considering the dispersion of phase velocity is rational and in good agreement with experiment data.
基金Supported by the National Natural Science Foundation of China (20776086)
文摘Mass transfer enhancement of gas absorption by adding a dispersed organic phase has been studied in this work. Various dispersed organic phases (heptanol, octanol, isoamyl alcohol, heptane, octane, and isooctane) were tested respectively in the experiment. According to the theoretical model and experimental data, the overall volumetric mass transfer coefficient and enhancement factor were obtained under different dispersed organic phase volume fraction and stirring speed. The experimental results indicate that gas-liquid mass transfer is enhanced at different level by adding a dispersed organic phase. The best performance of enhancement were achieved with the dispersed organic phase volumetric fraction of 5% and under an intermediate stirring speed of 670 r·min^-1. Among the organic phases tested in the experiment, alcohols show better performance, which gave 20% higher enhance-ment of overall volumetric mass transfer coefficient than adding alkanes.
文摘Using experimental data from a number of pulsed disc and doughnut solvent extraction columns, a unified correla- tion for the prediction of dispersed phase holdup that considers the effects of mass transfer is presented. Pulsed disc and doughnut solvent extraction columns (PDDC) have been used for a range of important applications such as ura- nium extraction and nuclear fuel recycling. Although the dispersed phase holdup in a PDDC has been presented by some researchers, there is still the need to develop a robust correlation that can predict the experimental dispersed phase holdup over a range of operating conditions including the effects of mass transfer direction. In this study, dis- persed phase holdup data from different literature sources for a PDDC were used to refit constants for the correlation presented by Kumar and Hartland lind. Eng. Chem. Res.,27 (1988),131-138] which did not consider the effect of col- umn geometry. In order to incorporate the characteristic length of the PDDC (i.e. the plate spacing), the unified cor- relation for holdup proposed by Kumar and Hartland based on data from eight different types of columns [Ind. Eng. Chem. Res.,34 (1995) 3925-3940] was refitted to the PDDC data. New constants have been presented for each hold- up correlation for a PDDC based on regression analysis using published holdup data from PDDCs that cover a range of onerating conditions and nhwical nronerties and consider the direction of mass transfer.
基金the National Natural Science Foundation of China! (No.19834020).
文摘We have prepared novel coated particles, with a conductor graphite core and a dielectric TiO2 coating, as the dispersed phase of electrorheological fluids. One order of magnitude enhancement in the shear stress is obtained by using such composite particles, when it is compared with that of TiO2 particles. The experimental results show a way to get excellent ER system.
基金Supported by the National Natural Science Foundation of China(No90401009)the Natural Science Foundation of Shaanxi Province, China(NoSJ08B16)+1 种基金the Science Research Program of Education Department of Shaanxi Province, China (No06JK215)the Research Fund for Excellent Doctoral Thesis of Xi'an University of Technology, China (No602-210805)
文摘The transport of Tb(III) in dispersion supported liquid membrane(DSLM) with polyvinylidene fluoride membrane(PVDF) as the support and dispersion solution including HCl solution as the stripping solution and di(2-ethylhexyl) phosphoric acid(D2EHPA) dissolved in kerosene as the membrane solution, has been studied. The effects of pH value, initial concentration of Tb(III) and different ionic strength in the feed phase, volume ratio of membrane solution to stripping solution, concentration of HCl solution, concentration of carrier, different stripping agents in the dispersion phase on the transport of Tb(III) have also been investigated, respectively. As a result, the optimum transport conditions of Tb(III) were obtained, i.e., the concentration of HCl solution was 4.0 mol/L, the concentration of D2EHPA was 0.16 mol/L, the volume ratio of membrane solution to stripping solution was 30:30 in the dispersion phase and pH value was 4.5 in the feed phase. Ionic strength had no obvious effect on the transport of Tb(III). Under the optimum conditions, the transport percentage of Tb(III) was up to 96.1% in a transport time of 35 min when the initial concentration of Tb(IIl) was 1.0× 10 -4 mol/L. The diffusion coefficient of Tb(III) in the membrane and the thickness of diffusion layer between feed phase and membrane phase were obtained and the values were 1.82×10 -8 m2/s and 5.61 um, respectively. The calculated results were in good agreement with the literature data.
基金supported by the National Natural Science Foundation of China(No.21607003).
文摘Residues of tetracycline antibiotics(TCs) in environments may be harmful to human.Due to their high polarities,it is extremely challenging to efficiently enrich TCs with low concentrations in natural waters for analysis.In this work,a magnetic metal-organic framework Fe_(3)O_(4)@[Cu_(3)(btc)_(2)]was synthesized and applied as a dispersive micro-solid phase extraction adsorbent for TCs enrichment.Effects of dispersive micro-solid phase extraction conditions including extraction time,solution p H,and elution solvent on the extraction efficiencies of TCs were investigated.Results show that TCs could be enriched efficiently by Fe_(3)O_(4)@[Cu_(3)(btc)_(2)],and electrostatic interaction between TCs and Fe_(3)O_(4)@[Cu_(3)(btc)_(2)]dominated this process.Combined with liquid chromatography-tandem mass spectrometry,four TCs residues (oxytetracycline,tetracycline,chlortetracycline,and doxycycline) in natural waters were determined.The detection limits (LOD,S/N=3) of the four antibiotics were 0.01-0.02μg/L,and the limits of quantitation (LOQ,S/N=10)were 0.04-0.07μg/L.The recoveries obtained from river water and aquaculture water spiked with three TCs concentration levels ranged from 70.3%to 96.5%with relative standard deviations of 3.8%-12.8%.Results indicate that the magnetic metal-organic framework based dispersive micro-solid phase extraction is simple,rapid and high-loading for antibiotics enrichment from water,which further expand the practical application of metal-organic frameworks in sample pretreatment for environmental pollutant analysis.
文摘The mass transfer process in a perforated rotating disk contactor(PRDC) using a toluene-acetone-water system was investigated.The volumetric overall mass transfer coefficients are calculated in a PRDC column.Both mass transfer directions are considered in experiments.The influences of operating variables containing agitation rate,dispersed and continuous phase flow rates and mass transfer in the extraction column are studied.According to obtained results,mass transfer is significantly dependent on agitation rate,while the dispersed and continuous phase flow rates have a minor effect on mass transfer in the extraction column.Furthermore,a novel empirical correlation is developed for prediction of overall continuous phase Sherwood number based on dispersed phase holdup,Reynolds number and mass transfer direction.There has been great agreement between experimental data and predicted values using a proposed correlation for all operating conditions.
文摘Fast ionic conductors are one kind of solid state material with ionic conductivity as high as that of melten salts or liquid electrolytes.Ionic conductivity is one of the important parameters for characterizing a fast ionic conductor.For a long time materialists and chemists have made great efforts in search of new fast ionic conductors with high ionic conductivity.In view of structure,they have synthesised silver and copper fast ionic conductors with so called open structures.But it is not so successful for searching more applicable alkaline fast ionic conductors.Since polymer has flexibility for making thin film,it concentrates attention on the polymer-alkaline salt complex.Fenton et al.have first reported poly(ethylene oxide) (PEO)-alkaline salt complex.Later on Armard et al.have investigated the electrical property of PEO-NaSCN.
基金This work was financially supported by the College of Natural Sciences,Jimma University through the grand research project(CNS-Chem-11-2020/21-SP1).
文摘Analysis of pesticide residue levels in juice beverages is important to ensure safe consumption and avoid global trade concerns associated to pesticide contaminations.A simple,inexpensive and effective method was developed for the determination of organochlorine pesticides(OCPs)in bottled juice drinks using GC-MS.Sample pretreatment was performed using dispersive solid-phase microextraction(D-μ-SPE)for matrix desorption and dispersive liquid-liquid microextraction(DLLME)for analyte enrichment.In this study,an affordable and effective sorbent for the adsorption of OCPs from juice samples was synthesized from avocado seeds mixed with magnetic precursors for D-μSPE.The ground avocado seeds combined with a magnetic precursor nanocomposite were characterized using various instruments including scanning electron microscopy(SEM),X-ray diffraction(XRD),Fourier transform infrared spectroscopy(FTIR),and Brunauer-Emmett-Teller(BET)analysis.The solution obtained from D-μ-SPE desorption was used as a dispersant for the subsequent DLLME,which made the combination of D-μ-SPE with DLLME much easier.The effectiveness of the method was enhanced by optimizing the influential parameters in both D-μ-SPE and DLLME.Then after,the optimal values were determined for the real sample analysis.Accordingly,there was good linear dynamic range with a coefficient of determination(r2)≥0.9989.The limit of detection and quantification were 0.02–0.69 and 0.06–2.10 ng/L respectively.The method showed high enrichment factors ranging from 96 to 313 with recoveries of 87–100%.Intraday and interday precisions were≤4%.Compared with other reported methods,this method is a one-step,simple,cheap,fast,and environmentally friendly alternative and straightforward method for adsorbing organochlorine pesticides from sample solutions.These results demonstrates the high potential of the proposed method for the extraction and cleanup of contaminants in selected juices and other related samples.
基金supported by the National Natural Science Foundation of China (10972182, 10772147, 10632030)the National Basic Research Program of China (2006CB 601202)+3 种基金the Doctorate Foundation of Northwestern Polytechnical University (CX200908)the Graduate Starting Seed Fund of Northwestern Polytechnical University (Z200930)the NPU Foundation for Fundamental Researchthe Open Foundation of State Key Laboratory of Structural Analysis of Industrial Equipment (GZ0802)
文摘On the basis of the finite element analysis, the elastic wave propagation in cellular structures is investigated using the symplectic algorithm. The variation principle is first applied to obtain the dual variables and the wave propagation problem is then transformed into two-dimensional (2D) symplectic eigenvalue problems, where the extended Wittrick-Williams algorithm is used to ensure that no phase propagation eigenvalues are missed during computation. Three typical cellular structures, square, triangle and hexagon, are introduced to illustrate the unique feature of the symplectic algorithm in higher-frequency calculation, which is due to the conserved properties of the structure-preserving symplectic algorithm. On the basis of the dispersion relations and phase constant surface analysis, the band structure is shown to be insensitive to the material type at lower frequencies, however, much more related at higher frequencies. This paper also demonstrates how the boundary conditions adopted in the finite element modeling process and the structures' configurations affect the band structures. The hexagonal cells are demonstrated to be more efficient for sound insulation at higher frequencies, while the triangular cells are preferred at lower frequencies. No complete band gaps are observed for the square cells with fixed-end boundary conditions. The analysis of phase constant surfaces guides the design of 2D cellular structures where waves at certain frequencies do not propagate in specified directions. The findings from the present study will provide invaluable guidelines for the future application of cellular structures in sound insulation.
文摘Mass transfer characteristics have been investigated in a 113 mm diameter asymmetric rotating disk contactor of the pilot plant scale for two different liquid–liquid systems. The effects of operating parameters including rotor speed and continuous and dispersed phase velocities on the volumetric overall mass transfer coefficients are investigated. The results show that the mass transfer performance is strongly dependent on agitation rate and interfacial tension, but only slightly dependent on phase flow rates. In this study, effective diffusivity is used instead of molecular diffusivity in the Grober equation for estimation of dispersed phase overall mass transfer coefficient.The enhancement factor is determined experimentally and there from an empirical expression is derived for prediction of the enhancement factor as a function of Reynolds number. The predicted results compared to the experimental data show that the proposed correlation can efficiently predict the overall mass transfer coefficients in asymmetric rotating disk contactors.
基金Supported by the National Natural Science Foundation of China(No.20490220)Open Fund of State Key Laboratory of Plastic Forming Simulation and Die & Mould Technology,China(No.05-10)+1 种基金Open Fund of Hubei Key Laboratory of Materials Chemistry and Service FailureProgram for New Century Excellent Talents in Universities of China(No.NCET-05-0640)
文摘Polypropylene(PP)/ethylene-octene copolymer(POE) blends were prepared with a twin-screw extruder.Their dynamic mechanical behavior were systematically investigated.The results show that PP/POE blends are heterogeneities with a partial compatible two-phase structure,the glass transition temperature of PP phases in the blends tends to shift towards high temperature with increasing the POE content,and the glass transition temperature of POE phases shifts towards the low temperature with increasing the PP content.The Kerner's dispersed phase model and co-continuous phase model can reasonably predict the visco-elasticity of PP/POE blends with different compositions.Additionally,the morphological structure of the blends can be estimated via comparing the predicted DMA behavior with the experimental data.
文摘The synthesis and characterization of several dispersed molybdena catalysts on silica support (MoO3-SiO2) prepared from a variety of precursors (Mo(VI)-acetylacetonate, oxo-peroxo Mo-species, hydrated ammonium heptamolybdate) and preparation methods (deposition of the Mo-phase on finite SiO2 support by aqueous and methanol impregnations, by adsorption, by oxo-peroxo route-like, and by one-step synthesis of MoO3-SiO2 system with molecular precursors) are presented. The molybdena concentration on silica was comprised in a large interval (1.5 - 14 wt%) depending on the preparation method which governed the Mo-loading on silica. Convenient comparisons among samples at similar Mo-concentration have been made discussing the morphologic-structural (XRD, XPS, UV-vis-DRS, and N2-adsorption) and physicochemical (TG-DTG, TPR, and n-butylamine-TPD) sample properties. Polymeric octahedral polymolybdate aggregates predominated in the samples prepared by aqueous and methanol impregnations, which were at high Mo-concentration. On the contrary, isolated Mo(VI) species in distorted Td symmetry predominated in the sample prepared by adsorption which was at very low Mo-concentration. The sample acidity was composed of a weak acidy site population, associated with the silica support, and a strong acid site population associated with the Mo-dispersed phase. Oxidation tests of formaldehyde, an oxygen-containing VOC (Volatile Organic Compound), were performed to determine the prevalent redox or acidic function of the Mo-species at the surface of the catalysts.
基金supported by the Health Institutes of Turkey(TüSEB)(Project No.2020CV01-8946)。
文摘A rapid,accurate,and sensitive analytical method,ultrasonication-assisted spraying based fine droplet formationeliquid phase microextractionegas chromatographyemass spectrometry(UA-SFDF-LPME-GCMS),was proposed for the determination of trace amounts of hydroxychloroquine sulfate in human serum,urine,and saliva samples.To determine the best extraction strategy,several liquid and solid phase extraction methods were investigated for their efficiencies in isolation and preconcentration of hydroxychloroquine sulfate from biological matrices.The UA-SFDF-LPME method was determined to be the best extraction method as it was operationally simple and provided accurate results.Variables such as the extraction solvent,spraying number,sodium hydroxide concentration and volume,sample volume,mixing method,and mixing period were optimized for the proposed method using the onevariable-at-a-time approach.In addition,Tukey’s method based on a post hoc comparison test was employed to evaluate the significant difference between the parameters inspected.After the optimization studies,the limit of detection(LOD)and limit of quantification(LOQ)were determined to be 0.7 and 2.4 mg/kg,respectively.The sensitivity of the GC-MS system based on the LOD was enhanced approximately 440-fold when the UA-SFDF-LPME method was employed.Spiking experiments were also conducted for the human serum,urine,and saliva samples to determine the applicability and accuracy of the proposed method.Recoveries for the human serum,urine,and saliva samples were found to be in the ranges of 93.9%-101.7%,95.2%-105.0%,and 93.1%-102.3%,respectively.These results were satisfactory and indicated that the hydroxychloroquine sulfate level in the above biological samples could be analyzed using the proposed method.
基金Financially supported by the National Natural Science Foundation of China(No.31701708)the Outstanding Youth Foundation Project of Fujian Agriculture and Forestry University of China(No.xjq201710)
文摘A novel 1-methylimidazole ionic liquid modified SBA15 mesoporous silica(1-MIIL@SBA15) was synthesized and applied to selective separation of inorganic arsenic(iAs) in rice by dispersive solid phase extraction(DSPE), followed by hydride generation-atomic fluorescence spectrometric(HG-AFS) quantification. The prepared sorbent was characterized by FTIR, FESEM, BET and Zeta potential. Key parameters of adsorption and desorption in DSPE were optimized using standard reference material 1568 b rice flour. Under optimal conditions, the limit of detection was 8.776 ng/kg, relative standard deviation was ≤2.0%, and recoveries of iAs were in the 92.3~94.4% range. This method was successfully applied to the determination of iAs in rice. Under acidic condition, the electrostatic interaction between the positively charged 1-MIIL@SBA15 and anionic iAs played an important role in selective iAs separation, rendering this method suitable for iAs analysis.