A novel iterative technique, the phase descent search detection was proposed. This technique constrained the solution (PDS) algorithm, for M-ary phase shift keying (M-PSK) symbols to have a unit magnitude and it w...A novel iterative technique, the phase descent search detection was proposed. This technique constrained the solution (PDS) algorithm, for M-ary phase shift keying (M-PSK) symbols to have a unit magnitude and it was based on coordinate descent iterations where coordinates were the unknown symbol phases. The PDS algorithm, together with a descent local search (also implemented as a version of the PDS algorithm), was used multiple times with different initializations in a proposed multiple phase detector; the solution with the minimum cost was then chosen as the final solution. The simulation results show that for highly loaded multiuser scenarios, the proposed technique has a detection performance that is close to the single-user bound. The results also show that the multiple phase detector allows detection in highly overloaded scenarios and it exhibits near-far resistance. In particular, the detector has a performance that is significantly better, and complexity that is significantly lower, than that of the detector based on semi-definite relaxation.展开更多
The technology for phase detection of liquid crystal optical device is a difficult research in current domestic and overseas. However, for the existing liquid crystal optical device, aiming at the poor anti-vibration ...The technology for phase detection of liquid crystal optical device is a difficult research in current domestic and overseas. However, for the existing liquid crystal optical device, aiming at the poor anti-vibration capability and poor versatile of phase detection, the complexity of phase retrieval algorithm, we propose a new phase measurement principle and experimental methods of liquid crystal optical device. It is a phase measurement method based on the combination of phase- shifting interferometer and phase conjugation technology. The deflection characteristics of the liquid crystal device means the device can implement phase modulation to only one direction of polarized light while is completely transparent to orthogonal polarized light. We put forward the phase shift of the orthogonal polarization phase shift interferometer method, using phase shifting interference as well as the combination of phase conjugate means to achieve its phase measurement. So we can retrieves devices modulation phase simply and efficiently combines with phase- shifting interferometer technology.展开更多
Based on chaotic oscillator system, this paper proposes a novel method on high frequency low signal- to-noise ratio BPSK( Binary Phase Shift Keying) signal detection. Chaotic oscillator system is a typical non-lin- ...Based on chaotic oscillator system, this paper proposes a novel method on high frequency low signal- to-noise ratio BPSK( Binary Phase Shift Keying) signal detection. Chaotic oscillator system is a typical non-lin- ear system which is sensitive to periodic signals and immune to noise at the same time. Those properties make it possible to detect low signal-to-noise ratio signals. The BPSK signal is a common signal type which is widely used in modern communication. Starting from the analysis of advantages of chaotic, os~.illator system and signal features of the BPSK signal, we put forward a unique method that can detect low signar-to-noise ratio BPSK sig- nals with high frequency. The simulation results show that the novel method can dclct.t low signal-to-noise ratio BPSK signals with frequency in an order of magnitude of l0s Hz, and the input Signal-to-Noise Ratio threshold can be -20 dB.展开更多
Maximum likelihood(ML) noncoherent block detection techniques are investigated for block-coded MPSK modulation in cooperative decode-and-forward relay systems over slow fading channels.A decision-directed iterative Vi...Maximum likelihood(ML) noncoherent block detection techniques are investigated for block-coded MPSK modulation in cooperative decode-and-forward relay systems over slow fading channels.A decision-directed iterative Viterbi algorithm(IVA) is derived for a suboptimal ML noncoherent detection.Simulation results show that the IVA can approach the error performances of the exhaustive detection method but at a lower complexity.展开更多
This paper introduces a new modulation and direct detection scheme of optical phase shift keying (PSK) which is simple and practical in fiber optical communication. A phase modulator is used to modulate a continuous w...This paper introduces a new modulation and direct detection scheme of optical phase shift keying (PSK) which is simple and practical in fiber optical communication. A phase modulator is used to modulate a continuous wave (CW) laser source and return-to-zero (RZ) signal that is changed from the initial transmitting information is used to control a phase modulator to form a optical PSK signal. In the receiver terminal, just add a signal delayed a half of one bit to itself so that the initial information can be restored.展开更多
According to the time&space conversion relations and different frequency phase detection principle,an ultra-high precision time&frequency measurement method is proposed in this paper.The higher accuracy and st...According to the time&space conversion relations and different frequency phase detection principle,an ultra-high precision time&frequency measurement method is proposed in this paper.The higher accuracy and stability of the speed of light and electromagnetic signals during the transmission in space or a specific medium enable the measurement of short time interval which uses the coincidence detection of signal’s transmission delay in length.The measurement precision better than 10 picoseconds can be easily obtained.The method develops the length vernier utilizing the stability of signal’s transmission delay,minimizes the fuzzy region of phase coincidence between the standard frequency signal and the measured signal,approaches the best phase coincidences and therefore improves the measurement precision which is higher than the precision provided by the traditional methods based on frequency processing.Besides,the method costs less than the traditional methods and can also solve the problem of the measurement of super-high frequency.Experimental results show the method can improve the measurement precision to 10 12/s in the time&frequency domain.展开更多
A portable analog lock-in amplifier capable of accurate phase detection is proposed in this paper. The proposed lock-in amplifier, which uses the dual-channel orthometric signals as the references to build the xy coor...A portable analog lock-in amplifier capable of accurate phase detection is proposed in this paper. The proposed lock-in amplifier, which uses the dual-channel orthometric signals as the references to build the xy coordinate system, can detect the relative phase between the input and x-axis based on trigonometric function. The sensitivity of the phase measurement reaches 0.014degree, and a detection precision of 0.1 degree is achieved. At the same time, the performance of the lock-in amplifier is verified in the high precision optical oxygen concentration detection. Experimental results reveal that the portable analog lock-in amplifier is accurate for phase detection applications. In the oxygen sensing experiments, 0.058% oxygen concentration resulted in 0.1 degree phase shift detected by the lock-in amplifier precisely. In addition, the lock-in amplifier is small and economical compared with the commercial lock-in equipments, so it can be easily integrated in many portable devices for industrial applications.展开更多
FBD检测法是一种有效的电网谐波电流检测方法,但受限于低通滤波器,传统FBD谐波检测法很难兼顾响应速度和检测精度。构建了一种基于自适应原理的新型FBD谐波检测法,利用改进后的最小均方(least mean square,LMS)算法替代原有低通滤波器,...FBD检测法是一种有效的电网谐波电流检测方法,但受限于低通滤波器,传统FBD谐波检测法很难兼顾响应速度和检测精度。构建了一种基于自适应原理的新型FBD谐波检测法,利用改进后的最小均方(least mean square,LMS)算法替代原有低通滤波器,使算法准确快速地检测出基波正序电流。在所提算法的基础上增加移相正反馈环节,增强了算法在负载电流突变时的动态响应特性。Matlab/Simulink环境下的仿真结果和实验室测试结果证明了所提改进算法的可行性和有效性。展开更多
文摘A novel iterative technique, the phase descent search detection was proposed. This technique constrained the solution (PDS) algorithm, for M-ary phase shift keying (M-PSK) symbols to have a unit magnitude and it was based on coordinate descent iterations where coordinates were the unknown symbol phases. The PDS algorithm, together with a descent local search (also implemented as a version of the PDS algorithm), was used multiple times with different initializations in a proposed multiple phase detector; the solution with the minimum cost was then chosen as the final solution. The simulation results show that for highly loaded multiuser scenarios, the proposed technique has a detection performance that is close to the single-user bound. The results also show that the multiple phase detector allows detection in highly overloaded scenarios and it exhibits near-far resistance. In particular, the detector has a performance that is significantly better, and complexity that is significantly lower, than that of the detector based on semi-definite relaxation.
文摘The technology for phase detection of liquid crystal optical device is a difficult research in current domestic and overseas. However, for the existing liquid crystal optical device, aiming at the poor anti-vibration capability and poor versatile of phase detection, the complexity of phase retrieval algorithm, we propose a new phase measurement principle and experimental methods of liquid crystal optical device. It is a phase measurement method based on the combination of phase- shifting interferometer and phase conjugation technology. The deflection characteristics of the liquid crystal device means the device can implement phase modulation to only one direction of polarized light while is completely transparent to orthogonal polarized light. We put forward the phase shift of the orthogonal polarization phase shift interferometer method, using phase shifting interference as well as the combination of phase conjugate means to achieve its phase measurement. So we can retrieves devices modulation phase simply and efficiently combines with phase- shifting interferometer technology.
文摘Based on chaotic oscillator system, this paper proposes a novel method on high frequency low signal- to-noise ratio BPSK( Binary Phase Shift Keying) signal detection. Chaotic oscillator system is a typical non-lin- ear system which is sensitive to periodic signals and immune to noise at the same time. Those properties make it possible to detect low signal-to-noise ratio signals. The BPSK signal is a common signal type which is widely used in modern communication. Starting from the analysis of advantages of chaotic, os~.illator system and signal features of the BPSK signal, we put forward a unique method that can detect low signar-to-noise ratio BPSK sig- nals with high frequency. The simulation results show that the novel method can dclct.t low signal-to-noise ratio BPSK signals with frequency in an order of magnitude of l0s Hz, and the input Signal-to-Noise Ratio threshold can be -20 dB.
基金supported by the National Natural Science Foundation of China(61302095,61401165)the Natural Science Foundation of Fujian Province of China(2014J01243,2014J05076,2015J01262)the Huaqiao University Science Foundation(13Y0384)
文摘Maximum likelihood(ML) noncoherent block detection techniques are investigated for block-coded MPSK modulation in cooperative decode-and-forward relay systems over slow fading channels.A decision-directed iterative Viterbi algorithm(IVA) is derived for a suboptimal ML noncoherent detection.Simulation results show that the IVA can approach the error performances of the exhaustive detection method but at a lower complexity.
文摘This paper introduces a new modulation and direct detection scheme of optical phase shift keying (PSK) which is simple and practical in fiber optical communication. A phase modulator is used to modulate a continuous wave (CW) laser source and return-to-zero (RZ) signal that is changed from the initial transmitting information is used to control a phase modulator to form a optical PSK signal. In the receiver terminal, just add a signal delayed a half of one bit to itself so that the initial information can be restored.
基金supported by the National Natural Science Foundation of China (Grant No. U1304618)the Open Fund of Key Laboratory of Precision Navigation and Timing Technology of Chinese Academy of Sciences(Grant No. 2012PNTT01)+5 种基金the Postdoctoral Grant of China (Grant Nos. 2011M501446, 2012T50798)the Basic and Advanced Technology Research Foundation of Henan Province under Grant (Grant No. 122300410169)The Key Science and Technology Foundation of Henan Province under Grant (Grant No. 132102210180)the Doctor Fund of Zhengzhou University of Light Industry under (Grant No. 2011BSJJ031)the Scientific Research Fund of Zhengzhou University of Light Industry under (Grant No. 2012XJJ009)the Fundamental Research Funds for the Central Universities(Grant No. K5051204003)
文摘According to the time&space conversion relations and different frequency phase detection principle,an ultra-high precision time&frequency measurement method is proposed in this paper.The higher accuracy and stability of the speed of light and electromagnetic signals during the transmission in space or a specific medium enable the measurement of short time interval which uses the coincidence detection of signal’s transmission delay in length.The measurement precision better than 10 picoseconds can be easily obtained.The method develops the length vernier utilizing the stability of signal’s transmission delay,minimizes the fuzzy region of phase coincidence between the standard frequency signal and the measured signal,approaches the best phase coincidences and therefore improves the measurement precision which is higher than the precision provided by the traditional methods based on frequency processing.Besides,the method costs less than the traditional methods and can also solve the problem of the measurement of super-high frequency.Experimental results show the method can improve the measurement precision to 10 12/s in the time&frequency domain.
文摘A portable analog lock-in amplifier capable of accurate phase detection is proposed in this paper. The proposed lock-in amplifier, which uses the dual-channel orthometric signals as the references to build the xy coordinate system, can detect the relative phase between the input and x-axis based on trigonometric function. The sensitivity of the phase measurement reaches 0.014degree, and a detection precision of 0.1 degree is achieved. At the same time, the performance of the lock-in amplifier is verified in the high precision optical oxygen concentration detection. Experimental results reveal that the portable analog lock-in amplifier is accurate for phase detection applications. In the oxygen sensing experiments, 0.058% oxygen concentration resulted in 0.1 degree phase shift detected by the lock-in amplifier precisely. In addition, the lock-in amplifier is small and economical compared with the commercial lock-in equipments, so it can be easily integrated in many portable devices for industrial applications.
文摘FBD检测法是一种有效的电网谐波电流检测方法,但受限于低通滤波器,传统FBD谐波检测法很难兼顾响应速度和检测精度。构建了一种基于自适应原理的新型FBD谐波检测法,利用改进后的最小均方(least mean square,LMS)算法替代原有低通滤波器,使算法准确快速地检测出基波正序电流。在所提算法的基础上增加移相正反馈环节,增强了算法在负载电流突变时的动态响应特性。Matlab/Simulink环境下的仿真结果和实验室测试结果证明了所提改进算法的可行性和有效性。