Two phase extraction methods which are based separately on phase-stepping and shifting curve are mainly used in phase-sensitive imaging in gating interferometry to determine the x-ray phase shift induced by an object ...Two phase extraction methods which are based separately on phase-stepping and shifting curve are mainly used in phase-sensitive imaging in gating interferometry to determine the x-ray phase shift induced by an object in the beam. In this paper, the authors perform a full comparative analysis and present the main virtues and limitations of these two methods according to the theoretical analysis of the grating interferometry.展开更多
In this paper, we propose an instantaneous phase-stepping method for determining phase distribution of interference fringes utilizing a camera that is equipped with a micro-polarizer array on the sensor plane. An opti...In this paper, we propose an instantaneous phase-stepping method for determining phase distribution of interference fringes utilizing a camera that is equipped with a micro-polarizer array on the sensor plane. An optical setup of polarization interferometry using a Mach-Zehnder interferometer with two polarizers is constructed. Light emerging from the interferometer is recorded using a camera that has a micro-polarizer array. This micro-polarizer array has four different optical axes. That is, an image obtained by the camera contains four types of information corresponding to four different optical axes of the polarizer. The four images separated from the image recorded by the camera are reconstructed using gray level interpolation. Subsequently, the distributions of the Stokes parameters that represent the state of polarization are calculated from the four images. The phase distribution of the interference fringe pattern produced by the Mach-Zehnder interferometer is then obtained from these Stokes parameters, The effectiveness of the proposed method is demonstrated by measuring a static carrier pattern and time-variant fringe patterns. It is emphasized that this method is applicable to time-variant phenomena because multiple exposures are unnecessary for sufficient data acquisition in the completion of the phase analysis.展开更多
Grating-based x-ray phase contrast imaging has the potential to be applied in future medical applications as it is compatible with both laboratory and synchrotron source. However, information retrieval methods are imp...Grating-based x-ray phase contrast imaging has the potential to be applied in future medical applications as it is compatible with both laboratory and synchrotron source. However, information retrieval methods are important because acquisition speed, scanning mode, image quality, and radiation dose depend on them. Phase-stepping (PS) is a widely used method to retrieve information, while angular signal radiography (ASR) is a newly established method. In this manuscript, signal-to-noise ratios (SNRs) of ASR are compared with that of PS. Numerical experiments are performed to validate theoretical results. SNRs comparison shows that for refraction and scattering images ASR has higher SNR than PS method, while for absorption image both methods have same SNR. Therefore, our conclusions would have guideline in future preclinical and clinical applications.展开更多
基金Project supported by the Key Program of the National Natural Science Foundation of China(Grant Nos.10490194 and 10734070) the National Natural Science Foundation of China(Grant Nos.10504033,10774144 and 10979055)+2 种基金the Knowledge Innovation Program of the Chinese Academy of Sciences(Grant No.KJCX2-YW-N42)the National Basic Research Program of China (Grant No.2009CB930804)the National Outstanding Youth Fund(Grant No.10125523)
文摘Two phase extraction methods which are based separately on phase-stepping and shifting curve are mainly used in phase-sensitive imaging in gating interferometry to determine the x-ray phase shift induced by an object in the beam. In this paper, the authors perform a full comparative analysis and present the main virtues and limitations of these two methods according to the theoretical analysis of the grating interferometry.
文摘In this paper, we propose an instantaneous phase-stepping method for determining phase distribution of interference fringes utilizing a camera that is equipped with a micro-polarizer array on the sensor plane. An optical setup of polarization interferometry using a Mach-Zehnder interferometer with two polarizers is constructed. Light emerging from the interferometer is recorded using a camera that has a micro-polarizer array. This micro-polarizer array has four different optical axes. That is, an image obtained by the camera contains four types of information corresponding to four different optical axes of the polarizer. The four images separated from the image recorded by the camera are reconstructed using gray level interpolation. Subsequently, the distributions of the Stokes parameters that represent the state of polarization are calculated from the four images. The phase distribution of the interference fringe pattern produced by the Mach-Zehnder interferometer is then obtained from these Stokes parameters, The effectiveness of the proposed method is demonstrated by measuring a static carrier pattern and time-variant fringe patterns. It is emphasized that this method is applicable to time-variant phenomena because multiple exposures are unnecessary for sufficient data acquisition in the completion of the phase analysis.
基金Project supported by the National Research and Development Project for Key Scientific Instruments(Grant No.CZBZDYZ20140002)the National Natural Science Foundation of China(Grant Nos.11535015,11305173,and 11375225)+2 种基金the project supported by Institute of High Energy Physics,Chinese Academy of Sciences(Grant No.Y4545320Y2)the Fundamental Research Funds for the Central Universities(Grant No.WK2310000065)Wali Faiz,acknowledges and wishes to thank the Chinese Academy of Sciences and The World Academy of Sciences(CAS-TWAS)President’s Fellowship Program for generous financial support
文摘Grating-based x-ray phase contrast imaging has the potential to be applied in future medical applications as it is compatible with both laboratory and synchrotron source. However, information retrieval methods are important because acquisition speed, scanning mode, image quality, and radiation dose depend on them. Phase-stepping (PS) is a widely used method to retrieve information, while angular signal radiography (ASR) is a newly established method. In this manuscript, signal-to-noise ratios (SNRs) of ASR are compared with that of PS. Numerical experiments are performed to validate theoretical results. SNRs comparison shows that for refraction and scattering images ASR has higher SNR than PS method, while for absorption image both methods have same SNR. Therefore, our conclusions would have guideline in future preclinical and clinical applications.