期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
H_α/ D_α Measurements Based on Photo Diode Array in the HT-7 Tokamak 被引量:1
1
作者 刘建坤 吴振伟 +2 位作者 万宝年 张先梅 周倩 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第5期997-1004,共8页
Photo Diode Array (PDA) has been successfully applied in HT-7 tokamak experiments. The PDA system is almost free of electromagnetic interference from the machine. The system is compact and inexpensive, and it is conve... Photo Diode Array (PDA) has been successfully applied in HT-7 tokamak experiments. The PDA system is almost free of electromagnetic interference from the machine. The system is compact and inexpensive, and it is convenient to be arranged in experiment. With the PDA system, the particle confinement time (τp) has been systematically investigated. The relations such as τp on the center-line-averaged electron density (ne), τp on plasma current (Ip), and τp, on the toroidal magnetic field (Bt) have been obtained. The particle confinement under the Ion Berstain Wave (IBW) Heating has also been measured and analyzed. 展开更多
关键词 Measurements Based on photo diode Array in the HT-7 Tokamak HT PDA
下载PDF
Validation of Metformin Hydrochloride in Human Plasma by HPLC-Photo Diode Array (PDA) for Application of Bioequivalence Study
2
作者 Yahdiana Harahap Krisnasari Dianpratami Mahi Wulandari Rina Rahmawati 《Journal of Life Sciences》 2012年第1期20-27,共8页
A sensitive and specific high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of metformin hydrochloride (HCI) in human plasma. The HPLC method consis... A sensitive and specific high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of metformin hydrochloride (HCI) in human plasma. The HPLC method consists of isocratic eluation with a mixture of 60% buffer (10 mM sodium dihyrogenphosphate-10 mM sodium dodecyl sulphate) and 40% acetonitrile with final pH 7.0 with flow rate of 1.0 mL/min on a Kromasil~ Akzo Nobel RP-18 (4.6 mm ID ~ 250 mm, 5 ~tm) column at an ambient temperature. Photo diode array detection was performed in program mode at 234 rim. The analyte and diazepam as internal standard (IS) were extracted from plasma using 10% trichloroacetic acid. The assay was linear over the therapeutic concentration range of 20-2,500 ng/mL for metformin HCI with correlation coefficient of r = 0.9999. Limit of quantitation was 20 ng/mL. The results obtained for intraJinter day accuracy and precision complied very well with the generally accepted criteria for bio-analytical assay. The method was applied to bioequivalence (BE) study of metformin HCI in healthy Indonesian volunteers after treatment with 750 mg XR metformin HCI. This BE study shows that the two formulations are equivalent so that they were therapeutically interchangeable for each other. 展开更多
关键词 Metformin HCl DIAZEPAM HPLC sodium dodecyl sulphate (SDS) photo diode array (PDA) detector bioequivalence(BE) study.
下载PDF
Optical recordings reveal the differential distribution of glutamatergic transmission in the cochlear and vestibular nuclei in the newborn mouse brainstem
3
作者 Doi Tadashi Kaneko Toshihiko +2 位作者 Matsumoto Ayumi Asako Mikiya Yamashita Toshio 《Journal of Otology》 2009年第2期106-114,共9页
Objective Using optical imaging in brainstem slices, we studied evoked responses in the mouse cochlear (CN) and vestibular (VN) nuclei. Methods The use of optical imaging allowed us to visualize the spatiotemporal pat... Objective Using optical imaging in brainstem slices, we studied evoked responses in the mouse cochlear (CN) and vestibular (VN) nuclei. Methods The use of optical imaging allowed us to visualize the spatiotemporal patterns of excitatory propagation in the CN and VN. Optical recordings can differentiate excitatory propagation in the ventral CN(VCN) from that in the dorsal CN(DCN). Furthermore, we assessed the relative distribution of NMDA and non-NMDA receptors in these regions using the glutamate antagonists APV (NMDA receptor antagonist) and CNQX (non-NMDA receptor antagonist) in mouse brainstem slices during postnatal days 1 to 3. Results The average sensitivity to APV was 99.1% in the VCN, 76.0% in the DCN and 64.9% in the VN. The average sensitivity to CNQX was 0.9% in the VCN, 24.0% in the DCN and 35.1% in the VN. These results indicate that the effect of APV dominated in the VCN, while both APV and CNQX were effective antagonists in the DCN and VN. In the VN, the distribution of APV-and CNQX-sensitive cells was almost completely uniform. However, in the DCN the distribution of APV-and CNQX-sensitive cells was highly complex. The area that was more sensitive to CNQX was located in the superficial layer of the DCN while the area with a higher sensitivity to APV was located progressively in the deep layer. Conclusion This optical recording data suggests that there is a differential distribution of NMDA and non-NMDA receptor mediated neurotransmission in the VCN, DCN and VN. 展开更多
关键词 voltage-sensitive dye NMDA non-NMDA photo diode array
下载PDF
Heterodyne Standing-Wave Interferometer with Improved Phase Stability 被引量:1
4
作者 Ingo Ortlepp Jens-Peter Zollner +1 位作者 Ivo W.Rangelow Eberhard Manske 《Nanomanufacturing and Metrology》 2021年第3期190-199,共10页
This paper describes a standing-wave interferometer with two laser sources of different wavelengths,diametrically opposed and emitting towards each other.The resulting standing wave has an intensity profile which is m... This paper describes a standing-wave interferometer with two laser sources of different wavelengths,diametrically opposed and emitting towards each other.The resulting standing wave has an intensity profile which is moving with a constant velocity,and is directly detected inside the laser beam by two thin and transparent photo sensors.The first sensor is at a fixed position,serving as a phase reference for the second one which is moved along the optical axis,resulting in a frequency shift,proportional to the velocity.The phase difference between both sensors is evaluated for the purpose of interferometric length measurements. 展开更多
关键词 Standing wave INTERFEROMETER HETERODYNE Ultrathin photo diode
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部